-- Indicator Light Flasher
--
local tcd = require("scada-common.tcd")
2022-10-12 20:37:11 +00:00
local flasher = {}
-- note: no additional call needs to be made in a main loop as this class automatically uses the TCD to operate
---@alias PERIOD integer
local PERIOD = {
BLINK_250_MS = 1,
BLINK_500_MS = 2,
BLINK_1000_MS = 3
}
flasher.PERIOD = PERIOD
local active = false
local registry = { {}, {}, {} } -- one registry table per period
local callback_counter = 0
2023-02-25 00:50:01 +00:00
-- blink registered indicators<br>
2022-10-20 16:23:00 +00:00
-- this assumes it is called every 250ms, it does no checking of time on its own
local function callback_250ms()
if active then
2022-11-02 16:02:52 +00:00
for _, f in ipairs(registry[PERIOD.BLINK_250_MS]) do f() end
2022-10-20 16:23:00 +00:00
if callback_counter % 2 == 0 then
2022-11-02 16:02:52 +00:00
for _, f in ipairs(registry[PERIOD.BLINK_500_MS]) do f() end
2022-10-20 16:23:00 +00:00
end
if callback_counter % 4 == 0 then
2022-11-02 16:02:52 +00:00
for _, f in ipairs(registry[PERIOD.BLINK_1000_MS]) do f() end
2022-10-20 16:23:00 +00:00
end
callback_counter = callback_counter + 1
2022-10-21 19:15:56 +00:00
tcd.dispatch_unique(0.25, callback_250ms)
2022-10-20 16:23:00 +00:00
end
end
-- start/resume the flasher periodic
function flasher.run()
2022-10-12 20:37:11 +00:00
active = true
2022-10-20 16:23:00 +00:00
callback_250ms()
2022-10-12 20:37:11 +00:00
end
2022-10-20 16:23:00 +00:00
-- clear all blinking indicators and stop the flasher periodic
2022-10-12 20:37:11 +00:00
function flasher.clear()
active = false
callback_counter = 0
2022-10-12 20:37:11 +00:00
registry = { {}, {}, {} }
end
2023-02-25 00:50:01 +00:00
-- register a function to be called on the selected blink period<br>
2022-10-12 20:37:11 +00:00
-- times are not strictly enforced, but all with a given period will be set at the same time
---@param f function function to call each period
---@param period PERIOD time period option (1, 2, or 3)
function flasher.start(f, period)
if type(registry[period]) == "table" then
table.insert(registry[period], f)
end
end
-- stop a function from being called at the blink period
---@param f function function callback registered
function flasher.stop(f)
for i = 1, #registry do
2022-11-02 16:02:52 +00:00
for key, val in ipairs(registry[i]) do
if val == f then
table.remove(registry[i], key)
return
2022-10-12 20:37:11 +00:00
end
end
end
end
return flasher