@ -524,7 +524,7 @@ function facility.new(num_reactors, cooling_conf)
ready = false
elseif (self.mode_set == PROCESS.GEN_RATE) and (self.gen_rate_target <= 0) then
ready = false
elseif (self.mode_set == PROCESS.BURN_RATE) and (self.burn_target <= 0.1) then
elseif (self.mode_set == PROCESS.BURN_RATE) and (self.burn_target < 0.1) then
ready = false
end

View File

@ -731,7 +731,6 @@ function plc.new_session(id, for_reactor, in_queue, out_queue)
if self.auto_cmd_token > 0 then
if self.auto_lock then
_send(RPLC_TYPES.AUTO_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate, self.auto_cmd_token })
log.debug("retried auto burn rate?")
else
-- would have been an auto command, but disengaged, so stop retrying
self.acks.burn_rate = true

View File

@ -26,6 +26,7 @@ local IO = rsio.IO
local FLOW_STABILITY_DELAY_MS = 15000
local DT_KEYS = {
ReactorBurnR = "RBR",
ReactorTemp = "RTP",
ReactorFuel = "RFL",
ReactorWaste = "RWS",
@ -86,7 +87,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
status_text = { "UNKNOWN", "awaiting connection..." },
-- logic for alarms
had_reactor = false,
start_ms = 0,
last_rate_change_ms = 0,
plc_cache = {
active = false,
ok = false,
@ -245,6 +246,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
local last_update_s = plc_db.last_status_update / 1000.0
_compute_dt(DT_KEYS.ReactorBurnR, plc_db.mek_status.act_burn_rate, last_update_s)
_compute_dt(DT_KEYS.ReactorTemp, plc_db.mek_status.temp, last_update_s)
_compute_dt(DT_KEYS.ReactorFuel, plc_db.mek_status.fuel, last_update_s)
_compute_dt(DT_KEYS.ReactorWaste, plc_db.mek_status.waste, last_update_s)
@ -409,7 +411,7 @@ function unit.new(for_reactor, num_boilers, num_turbines)
---@return boolean complete
function public.a_ramp_complete()
if self.plc_i ~= nil then
return self.plc_i.is_ramp_complete()
return self.plc_i.is_ramp_complete() or (self.plc_i.get_status().act_burn_rate == 0 and self.db.control.br10 == 0)
else return true end
end

View File

@ -54,11 +54,9 @@ function logic.update_annunciator(self)
self.db.control.lim_br10 = math.floor(plc_db.mek_struct.max_burn * 10)
end
-- record reactor start time (some alarms are delayed during reactor heatup)
if self.start_ms == 0 and plc_db.mek_status.status then
self.start_ms = util.time_ms()
elseif not plc_db.mek_status.status then
self.start_ms = 0
-- some alarms wait until the burn rate has stabilized, so keep track of that
if math.abs(_get_dt(DT_KEYS.ReactorBurnR)) > 0 then
self.last_rate_change_ms = util.time_ms()
end
-- record reactor stats
@ -237,8 +235,8 @@ function logic.update_annunciator(self)
self.db.annunciator.TurbineOnline[session.get_device_idx()] = true
end
-- check for boil rate mismatch (either between reactor and turbine or boiler and turbine)
self.db.annunciator.BoilRateMismatch = math.abs(total_boil_rate - total_input_rate) > 4
-- check for boil rate mismatch (> 4% error) either between reactor and turbine or boiler and turbine
self.db.annunciator.BoilRateMismatch = math.abs(total_boil_rate - total_input_rate) > (0.04 * total_boil_rate)
-- check for steam feed mismatch and max return rate
local sfmismatch = math.abs(total_flow_rate - total_input_rate) > 10
@ -436,7 +434,7 @@ function logic.update_alarms(self)
-- annunciator indicators for these states may not indicate a real issue when:
-- > flow is ramping up right after reactor start
-- > flow is ramping down after reactor shutdown
if (util.time_ms() - self.start_ms > self.defs.FLOW_STABILITY_DELAY_MS) and plc_cache.active then
if ((util.time_ms() - self.last_rate_change_ms) > self.defs.FLOW_STABILITY_DELAY_MS) and plc_cache.active then
rcs_trans = rcs_trans or annunc.BoilRateMismatch or annunc.CoolantFeedMismatch or annunc.SteamFeedMismatch
end
@ -517,7 +515,7 @@ function logic.update_status_text(self)
self.status_text[2] = "insufficient fuel input rate"
elseif self.db.annunciator.WasteLineOcclusion then
self.status_text[2] = "insufficient waste output rate"
elseif (util.time_ms() - self.start_ms) <= self.defs.FLOW_STABILITY_DELAY_MS then
elseif (util.time_ms() - self.last_rate_change_ms) <= self.defs.FLOW_STABILITY_DELAY_MS then
if self.num_turbines > 1 then
self.status_text[2] = "turbines spinning up"
else

View File

@ -14,7 +14,7 @@ local svsessions = require("supervisor.session.svsessions")
local config = require("supervisor.config")
local supervisor = require("supervisor.supervisor")
local SUPERVISOR_VERSION = "beta-v0.9.12"
local SUPERVISOR_VERSION = "beta-v0.9.13"
local print = util.print
local println = util.println