Merge pull request #254 from MikaylaFischler/devel

2023.06.07 Release
This commit is contained in:
Mikayla 2023-06-07 17:46:50 -04:00 committed by GitHub
commit 193aeed6df
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
90 changed files with 2221 additions and 838 deletions

95
.github/workflows/manifest.yml vendored Normal file
View File

@ -0,0 +1,95 @@
# Simple workflow for deploying static content to GitHub Pages
name: Deploy Installation Manifests and Versions
on:
workflow_dispatch:
push:
branches:
- main
- latest
- devel
# Sets permissions of the GITHUB_TOKEN to allow deployment to GitHub Pages
permissions:
contents: read
pages: write
id-token: write
# Allow only one concurrent deployment, skipping runs queued between the run in-progress and latest queued.
# However, do NOT cancel in-progress runs as we want to allow these production deployments to complete.
concurrency:
group: "pages"
cancel-in-progress: false
jobs:
# Single deploy job since we're just deploying
deploy:
environment:
name: github-pages
url: ${{ steps.deployment.outputs.page_url }}
runs-on: ubuntu-latest
steps:
- name: Setup Pages
uses: actions/configure-pages@v3
- name: Setup Python
uses: actions/setup-python@v3.1.3
# Generate manifest + shields files for main branch
- name: Checkout main
id: checkout-main
uses: actions/checkout@v3
with:
ref: 'main'
clean: false
- name: Create outputs folders
if: success() || failure()
shell: bash
run: mkdir deploy; mkdir deploy/manifests; mkdir deploy/manifests/main deploy/manifests/latest deploy/manifests/devel
- name: Generate manifest and shields for main branch
id: manifest-main
if: ${{ (success() || failure()) && steps.checkout-main.outcome == 'success' }}
run: python imgen.py shields
- name: Save main's manifest
if: ${{ (success() || failure()) && steps.manifest-main.outcome == 'success' }}
run: mv install_manifest.json deploy/manifests/main
# Generate manifest for latest branch
- name: Checkout latest
id: checkout-latest
if: success() || failure()
uses: actions/checkout@v3
with:
ref: 'latest'
clean: false
- name: Generate manifest for latest
id: manifest-latest
if: ${{ (success() || failure()) && steps.checkout-latest.outcome == 'success' }}
run: python imgen.py
- name: Save latest's manifest
if: ${{ (success() || failure()) && steps.manifest-latest.outcome == 'success' }}
run: mv install_manifest.json deploy/manifests/latest
# Generate manifest for devel branch
- name: Checkout devel
id: checkout-devel
if: success() || failure()
uses: actions/checkout@v3
with:
ref: 'devel'
clean: false
- name: Generate manifest for devel
id: manifest-devel
if: ${{ (success() || failure()) && steps.checkout-devel.outcome == 'success' }}
run: python imgen.py
- name: Save devel's manifest
if: ${{ (success() || failure()) && steps.manifest-devel.outcome == 'success' }}
run: mv install_manifest.json deploy/manifests/devel
# All artifacts ready now, upload deploy directory
- name: Upload artifacts
id: upload-artifacts
if: ${{ (success() || failure()) && (steps.manifest-main.outcome == 'success' || steps.manifest-latest.outcome == 'success' || steps.manifest-devel.outcome == 'success') }}
uses: actions/upload-pages-artifact@v1
with:
# Upload manifest JSON
path: 'deploy/'
- name: Deploy to GitHub Pages
if: ${{ (success() || failure()) && steps.upload-artifacts.outcome == 'success' }}
id: deployment
uses: actions/deploy-pages@v2

View File

@ -1,47 +0,0 @@
# Simple workflow for deploying static content to GitHub Pages
name: Deploy Component Versions
on:
# Runs on pushes targeting the default branch
push:
branches: ["main"]
# Allows you to run this workflow manually from the Actions tab
workflow_dispatch:
# Sets permissions of the GITHUB_TOKEN to allow deployment to GitHub Pages
permissions:
contents: read
pages: write
id-token: write
# Allow only one concurrent deployment, skipping runs queued between the run in-progress and latest queued.
# However, do NOT cancel in-progress runs as we want to allow these production deployments to complete.
concurrency:
group: "pages"
cancel-in-progress: false
jobs:
# Single deploy job since we're just deploying
deploy:
environment:
name: github-pages
url: ${{ steps.deployment.outputs.page_url }}
runs-on: ubuntu-latest
steps:
- name: Checkout
uses: actions/checkout@v3
- name: Setup Pages
uses: actions/configure-pages@v3
- name: Setup Python
uses: actions/setup-python@v3.1.3
- run: mkdir shields
- run: python imgen.py shields
- name: Upload artifact
uses: actions/upload-pages-artifact@v1
with:
# Upload shields JSON
path: 'shields/'
- name: Deploy to GitHub Pages
id: deployment
uses: actions/deploy-pages@v2

View File

@ -20,9 +20,10 @@ SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
local function println(message) print(tostring(message)) end
local function print(message) term.write(tostring(message)) end
local CCMSI_VERSION = "v1.0"
local CCMSI_VERSION = "v1.2"
local install_dir = "/.install-cache"
local manifest_path = "https://mikaylafischler.github.io/cc-mek-scada/manifests/"
local repo_path = "http://raw.githubusercontent.com/MikaylaFischler/cc-mek-scada/"
local opts = { ... }
@ -122,8 +123,8 @@ if mode == "check" then
-- GET REMOTE MANIFEST --
-------------------------
if opts[2] then repo_path = repo_path .. opts[2] .. "/" else repo_path = repo_path .. "main/" end
local install_manifest = repo_path .. "install_manifest.json"
if opts[2] then manifest_path = manifest_path .. opts[2] .. "/" else manifest_path = manifest_path .. "main/" end
local install_manifest = manifest_path .. "install_manifest.json"
local response, error = http.get(install_manifest)
@ -203,7 +204,8 @@ elseif mode == "install" or mode == "update" then
-------------------------
if opts[3] then repo_path = repo_path .. opts[3] .. "/" else repo_path = repo_path .. "main/" end
local install_manifest = repo_path .. "install_manifest.json"
if opts[3] then manifest_path = manifest_path .. opts[3] .. "/" else manifest_path = manifest_path .. "main/" end
local install_manifest = manifest_path .. "install_manifest.json"
local response, error = http.get(install_manifest)

View File

@ -1,11 +1,11 @@
local config = {}
-- port of the SCADA supervisor
config.SCADA_SV_PORT = 16100
-- port to listen to incoming packets from supervisor
config.SCADA_SV_CTL_LISTEN = 16101
-- listen port for SCADA coordinator API access
config.SCADA_API_LISTEN = 16200
-- supervisor comms channel
config.SVR_CHANNEL = 16240
-- coordinator comms channel
config.CRD_CHANNEL = 16243
-- pocket comms channel
config.PKT_CHANNEL = 16244
-- max trusted modem message distance (0 to disable check)
config.TRUSTED_RANGE = 0
-- time in seconds (>= 2) before assuming a remote device is no longer active

View File

@ -213,14 +213,15 @@ end
---@nodiscard
---@param version string coordinator version
---@param modem table modem device
---@param sv_port integer port of configured supervisor
---@param sv_listen integer listening port for supervisor replys
---@param api_listen integer listening port for pocket API
---@param crd_channel integer port of configured supervisor
---@param svr_channel integer listening port for supervisor replys
---@param pkt_channel integer listening port for pocket API
---@param range integer trusted device connection range
---@param sv_watchdog watchdog
function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range, sv_watchdog)
function coordinator.comms(version, modem, crd_channel, svr_channel, pkt_channel, range, sv_watchdog)
local self = {
sv_linked = false,
sv_addr = comms.BROADCAST,
sv_seq_num = 0,
sv_r_seq_num = nil,
sv_config_err = false,
@ -236,8 +237,7 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
-- configure modem channels
local function _conf_channels()
modem.closeAll()
modem.open(sv_listen)
modem.open(api_listen)
modem.open(crd_channel)
end
_conf_channels()
@ -261,23 +261,24 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
end
pkt.make(msg_type, msg)
s_pkt.make(self.sv_seq_num, protocol, pkt.raw_sendable())
s_pkt.make(self.sv_addr, self.sv_seq_num, protocol, pkt.raw_sendable())
modem.transmit(sv_port, sv_listen, s_pkt.raw_sendable())
modem.transmit(svr_channel, crd_channel, s_pkt.raw_sendable())
self.sv_seq_num = self.sv_seq_num + 1
end
-- send an API establish request response
---@param dest integer
---@param msg table
local function _send_api_establish_ack(seq_id, dest, msg)
---@param packet scada_packet
---@param ack ESTABLISH_ACK
local function _send_api_establish_ack(packet, ack)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(SCADA_MGMT_TYPE.ESTABLISH, msg)
s_pkt.make(seq_id, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
m_pkt.make(SCADA_MGMT_TYPE.ESTABLISH, { ack })
s_pkt.make(packet.src_addr(), packet.seq_num() + 1, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
modem.transmit(dest, api_listen, s_pkt.raw_sendable())
modem.transmit(pkt_channel, crd_channel, s_pkt.raw_sendable())
self.last_api_est_acks[packet.src_addr()] = ack
end
-- attempt connection establishment
@ -307,7 +308,9 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
-- close the connection to the server
function public.close()
sv_watchdog.cancel()
self.sv_addr = comms.BROADCAST
self.sv_linked = false
self.sv_r_seq_num = nil
_send_sv(PROTOCOL.SCADA_MGMT, SCADA_MGMT_TYPE.CLOSE, {})
end
@ -335,12 +338,13 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
tick_dmesg_waiting(math.max(0, timeout_s - (util.time_s() - start)))
_send_establish()
clock.start()
elseif event == "timer" then
-- keep checking watchdog timers
apisessions.check_all_watchdogs(p1)
elseif event == "modem_message" then
-- handle message
local packet = public.parse_packet(p1, p2, p3, p4, p5)
if packet ~= nil and packet.type == SCADA_MGMT_TYPE.ESTABLISH then
public.handle_packet(packet)
end
public.handle_packet(packet)
elseif event == "terminate" then
terminated = true
break
@ -435,15 +439,18 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
---@param packet mgmt_frame|crdn_frame|capi_frame|nil
function public.handle_packet(packet)
if packet ~= nil then
local l_port = packet.scada_frame.local_port()
local r_port = packet.scada_frame.remote_port()
local l_chan = packet.scada_frame.local_channel()
local r_chan = packet.scada_frame.remote_channel()
local src_addr = packet.scada_frame.src_addr()
local protocol = packet.scada_frame.protocol()
if l_port == api_listen then
if l_chan ~= crd_channel then
log.debug("received packet on unconfigured channel " .. l_chan, true)
elseif r_chan == pkt_channel then
if protocol == PROTOCOL.COORD_API then
---@cast packet capi_frame
-- look for an associated session
local session = apisessions.find_session(r_port)
local session = apisessions.find_session(src_addr)
-- API packet
if session ~= nil then
@ -456,7 +463,7 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
elseif protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- look for an associated session
local session = apisessions.find_session(r_port)
local session = apisessions.find_session(src_addr)
-- SCADA management packet
if session ~= nil then
@ -464,8 +471,6 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
session.in_queue.push_packet(packet)
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- establish a new session
local next_seq_id = packet.scada_frame.seq_num() + 1
-- validate packet and continue
if packet.length == 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
local comms_v = packet.data[1]
@ -473,42 +478,43 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
local dev_type = packet.data[3]
if comms_v ~= comms.version then
if self.last_api_est_acks[r_port] ~= ESTABLISH_ACK.BAD_VERSION then
if self.last_api_est_acks[src_addr] ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping API establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
self.last_api_est_acks[r_port] = ESTABLISH_ACK.BAD_VERSION
end
_send_api_establish_ack(next_seq_id, r_port, { ESTABLISH_ACK.BAD_VERSION })
_send_api_establish_ack(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
elseif dev_type == DEVICE_TYPE.PKT then
-- pocket linking request
local id = apisessions.establish_session(l_port, r_port, firmware_v)
println(util.c("API: pocket (", firmware_v, ") [:", r_port, "] connected with session ID ", id))
coordinator.log_comms(util.c("API: pocket (", firmware_v, ") [:", r_port, "] connected with session ID ", id))
local id = apisessions.establish_session(src_addr, firmware_v)
println(util.c("[API] pocket (", firmware_v, ") [@", src_addr, "] \xbb connected"))
coordinator.log_comms(util.c("API_ESTABLISH: pocket (", firmware_v, ") [@", src_addr, "] connected with session ID ", id))
_send_api_establish_ack(next_seq_id, r_port, { ESTABLISH_ACK.ALLOW })
self.last_api_est_acks[r_port] = ESTABLISH_ACK.ALLOW
_send_api_establish_ack(packet.scada_frame, ESTABLISH_ACK.ALLOW)
else
log.debug(util.c("illegal establish packet for device ", dev_type, " on API listening channel"))
_send_api_establish_ack(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
log.debug(util.c("API_ESTABLISH: illegal establish packet for device ", dev_type, " on pocket channel"))
_send_api_establish_ack(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug("invalid establish packet (on API listening channel)")
_send_api_establish_ack(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
_send_api_establish_ack(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
-- any other packet should be session related, discard it
log.debug(util.c(r_port, "->", l_port, ": discarding SCADA_MGMT packet without a known session"))
log.debug(util.c("discarding pocket SCADA_MGMT packet without a known session from computer ", src_addr))
end
else
log.debug("illegal packet type " .. protocol .. " on api listening channel", true)
log.debug("illegal packet type " .. protocol .. " on pocket channel", true)
end
elseif l_port == sv_listen then
elseif r_chan == svr_channel then
-- check sequence number
if self.sv_r_seq_num == nil then
self.sv_r_seq_num = packet.scada_frame.seq_num()
elseif self.connected and ((self.sv_r_seq_num + 1) ~= packet.scada_frame.seq_num()) then
log.warning("sequence out-of-order: last = " .. self.sv_r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
return
elseif self.sv_linked and src_addr ~= self.sv_addr then
log.debug("received packet from unknown computer " .. src_addr .. " while linked; channel in use by another system?")
return
else
self.sv_r_seq_num = packet.scada_frame.seq_num()
end
@ -659,6 +665,7 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
-- init io controller
iocontrol.init(conf, public)
self.sv_addr = src_addr
self.sv_linked = true
self.sv_config_err = false
else
@ -704,10 +711,10 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
local trip_time = util.time() - timestamp
if trip_time > 750 then
log.warning("coord KEEP_ALIVE trip time > 750ms (" .. trip_time .. "ms)")
log.warning("coordinator KEEP_ALIVE trip time > 750ms (" .. trip_time .. "ms)")
end
-- log.debug("coord RTT = " .. trip_time .. "ms")
-- log.debug("coordinator RTT = " .. trip_time .. "ms")
iocontrol.get_db().facility.ps.publish("sv_ping", trip_time)
@ -718,7 +725,9 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
elseif packet.type == SCADA_MGMT_TYPE.CLOSE then
-- handle session close
sv_watchdog.cancel()
self.sv_addr = comms.BROADCAST
self.sv_linked = false
self.sv_r_seq_num = nil
println_ts("server connection closed by remote host")
log.info("server connection closed by remote host")
else
@ -731,7 +740,7 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
log.debug("illegal packet type " .. protocol .. " on supervisor listening channel", true)
end
else
log.debug("received packet on unconfigured channel " .. l_port, true)
log.debug("received packet for unknown channel " .. r_chan, true)
end
end
end

View File

@ -5,7 +5,7 @@ local util = require("scada-common.util")
local config = require("coordinator.config")
local api = require("coordinator.session.api")
local pocket = require("coordinator.session.pocket")
local apisessions = {}
@ -18,7 +18,7 @@ local self = {
-- PRIVATE FUNCTIONS --
-- handle a session output queue
---@param session api_session_struct
---@param session pkt_session_struct
local function _api_handle_outq(session)
-- record handler start time
local handle_start = util.time()
@ -31,7 +31,7 @@ local function _api_handle_outq(session)
if msg ~= nil then
if msg.qtype == mqueue.TYPE.PACKET then
-- handle a packet to be sent
self.modem.transmit(session.r_port, session.l_port, msg.message.raw_sendable())
self.modem.transmit(config.PKT_CHANNEL, config.CRD_CHANNEL, msg.message.raw_sendable())
elseif msg.qtype == mqueue.TYPE.COMMAND then
-- handle instruction/notification
elseif msg.qtype == mqueue.TYPE.DATA then
@ -41,15 +41,15 @@ local function _api_handle_outq(session)
-- max 100ms spent processing queue
if util.time() - handle_start > 100 then
log.warning("API out queue handler exceeded 100ms queue process limit")
log.warning(util.c("offending session: port ", session.r_port))
log.warning("[API] out queue handler exceeded 100ms queue process limit")
log.warning(util.c("[API] offending session: ", session))
break
end
end
end
-- cleanly close a session
---@param session api_session_struct
---@param session pkt_session_struct
local function _shutdown(session)
session.open = false
session.instance.close()
@ -58,11 +58,11 @@ local function _shutdown(session)
while session.out_queue.ready() do
local msg = session.out_queue.pop()
if msg ~= nil and msg.qtype == mqueue.TYPE.PACKET then
self.modem.transmit(session.r_port, session.l_port, msg.message.raw_sendable())
self.modem.transmit(config.PKT_CHANNEL, config.CRD_CHANNEL, msg.message.raw_sendable())
end
end
log.debug(util.c("closed API session ", session.instance.get_id(), " on remote port ", session.r_port))
log.debug(util.c("[API] closed session ", session))
end
-- PUBLIC FUNCTIONS --
@ -81,54 +81,60 @@ end
-- find a session by remote port
---@nodiscard
---@param port integer
---@return api_session_struct|nil
function apisessions.find_session(port)
---@param source_addr integer
---@return pkt_session_struct|nil
function apisessions.find_session(source_addr)
for i = 1, #self.sessions do
if self.sessions[i].r_port == port then return self.sessions[i] end
if self.sessions[i].s_addr == source_addr then return self.sessions[i] end
end
return nil
end
-- establish a new API session
---@nodiscard
---@param local_port integer
---@param remote_port integer
---@param source_addr integer
---@param version string
---@return integer session_id
function apisessions.establish_session(local_port, remote_port, version)
---@class api_session_struct
local api_s = {
function apisessions.establish_session(source_addr, version)
---@class pkt_session_struct
local pkt_s = {
open = true,
version = version,
l_port = local_port,
r_port = remote_port,
s_addr = source_addr,
in_queue = mqueue.new(),
out_queue = mqueue.new(),
instance = nil ---@type api_session
instance = nil ---@type pkt_session
}
api_s.instance = api.new_session(self.next_id, api_s.in_queue, api_s.out_queue, config.API_TIMEOUT)
table.insert(self.sessions, api_s)
local id = self.next_id
log.debug(util.c("established new API session to ", remote_port, " with ID ", self.next_id))
pkt_s.instance = pocket.new_session(id, source_addr, pkt_s.in_queue, pkt_s.out_queue, config.API_TIMEOUT)
table.insert(self.sessions, pkt_s)
self.next_id = self.next_id + 1
local mt = {
---@param s pkt_session_struct
__tostring = function (s) return util.c("PKT [", id, "] (@", s.s_addr, ")") end
}
setmetatable(pkt_s, mt)
log.debug(util.c("[API] established new session: ", pkt_s))
self.next_id = id + 1
-- success
return api_s.instance.get_id()
return pkt_s.instance.get_id()
end
-- attempt to identify which session's watchdog timer fired
---@param timer_event number
function apisessions.check_all_watchdogs(timer_event)
for i = 1, #self.sessions do
local session = self.sessions[i] ---@type api_session_struct
local session = self.sessions[i] ---@type pkt_session_struct
if session.open then
local triggered = session.instance.check_wd(timer_event)
if triggered then
log.debug(util.c("watchdog closing API session ", session.instance.get_id(),
" on remote port ", session.r_port, "..."))
log.debug(util.c("[API] watchdog closing session ", session, "..."))
_shutdown(session)
end
end
@ -138,7 +144,7 @@ end
-- iterate all the API sessions
function apisessions.iterate_all()
for i = 1, #self.sessions do
local session = self.sessions[i] ---@type api_session_struct
local session = self.sessions[i] ---@type pkt_session_struct
if session.open and session.instance.iterate() then
_api_handle_outq(session)
@ -152,10 +158,9 @@ end
function apisessions.free_all_closed()
local f = function (session) return session.open end
---@param session api_session_struct
---@param session pkt_session_struct
local on_delete = function (session)
log.debug(util.c("free'ing closed API session ", session.instance.get_id(),
" on remote port ", session.r_port))
log.debug(util.c("[API] free'ing closed session ", session))
end
util.filter_table(self.sessions, f, on_delete)
@ -164,7 +169,7 @@ end
-- close all open connections
function apisessions.close_all()
for i = 1, #self.sessions do
local session = self.sessions[i] ---@type api_session_struct
local session = self.sessions[i] ---@type pkt_session_struct
if session.open then _shutdown(session) end
end

View File

@ -3,7 +3,7 @@ local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local util = require("scada-common.util")
local api = {}
local pocket = {}
local PROTOCOL = comms.PROTOCOL
-- local CAPI_TYPE = comms.CAPI_TYPE
@ -21,8 +21,8 @@ local API_S_CMDS = {
local API_S_DATA = {
}
api.API_S_CMDS = API_S_CMDS
api.API_S_DATA = API_S_DATA
pocket.API_S_CMDS = API_S_CMDS
pocket.API_S_DATA = API_S_DATA
local PERIODICS = {
KEEP_ALIVE = 2000
@ -31,11 +31,12 @@ local PERIODICS = {
-- pocket API session
---@nodiscard
---@param id integer session ID
---@param s_addr integer device source address
---@param in_queue mqueue in message queue
---@param out_queue mqueue out message queue
---@param timeout number communications timeout
function api.new_session(id, in_queue, out_queue, timeout)
local log_header = "api_session(" .. id .. "): "
function pocket.new_session(id, s_addr, in_queue, out_queue, timeout)
local log_header = "pkt_session(" .. id .. "): "
local self = {
-- connection properties
@ -61,10 +62,10 @@ function api.new_session(id, in_queue, out_queue, timeout)
}
}
---@class api_session
---@class pkt_session
local public = {}
-- mark this API session as closed, stop watchdog
-- mark this pocket session as closed, stop watchdog
local function _close()
self.conn_watchdog.cancel()
self.connected = false
@ -92,7 +93,7 @@ function api.new_session(id, in_queue, out_queue, timeout)
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(s_addr, self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -117,8 +118,6 @@ function api.new_session(id, in_queue, out_queue, timeout)
-- process packet
if pkt.scada_frame.protocol() == PROTOCOL.COORD_API then
---@cast pkt capi_frame
-- feed watchdog
self.conn_watchdog.feed()
-- handle packet by type
if pkt.type == nil then
@ -136,11 +135,11 @@ function api.new_session(id, in_queue, out_queue, timeout)
self.last_rtt = srv_now - srv_start
if self.last_rtt > 750 then
log.warning(log_header .. "API KEEP_ALIVE round trip time > 750ms (" .. self.last_rtt .. "ms)")
log.warning(log_header .. "PKT KEEP_ALIVE round trip time > 750ms (" .. self.last_rtt .. "ms)")
end
-- log.debug(log_header .. "API RTT = " .. self.last_rtt .. "ms")
-- log.debug(log_header .. "API TT = " .. (srv_now - api_send) .. "ms")
-- log.debug(log_header .. "PKT RTT = " .. self.last_rtt .. "ms")
-- log.debug(log_header .. "PKT TT = " .. (srv_now - api_send) .. "ms")
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end
@ -173,7 +172,7 @@ function api.new_session(id, in_queue, out_queue, timeout)
function public.close()
_close()
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
println("connection to API session " .. id .. " closed by server")
println("connection to pocket session " .. id .. " closed by server")
log.info(log_header .. "session closed by server")
end
@ -212,7 +211,7 @@ function api.new_session(id, in_queue, out_queue, timeout)
-- exit if connection was closed
if not self.connected then
println("connection to API session " .. id .. " closed by remote host")
println("connection to pocket session " .. id .. " closed by remote host")
log.info(log_header .. "session closed by remote host")
return self.connected
end
@ -248,4 +247,4 @@ function api.new_session(id, in_queue, out_queue, timeout)
return public
end
return api
return pocket

View File

@ -4,23 +4,23 @@
require("/initenv").init_env()
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local ppm = require("scada-common.ppm")
local tcallbackdsp = require("scada-common.tcallbackdsp")
local util = require("scada-common.util")
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local core = require("graphics.core")
local core = require("graphics.core")
local config = require("coordinator.config")
local coordinator = require("coordinator.coordinator")
local iocontrol = require("coordinator.iocontrol")
local renderer = require("coordinator.renderer")
local sounder = require("coordinator.sounder")
local config = require("coordinator.config")
local coordinator = require("coordinator.coordinator")
local iocontrol = require("coordinator.iocontrol")
local renderer = require("coordinator.renderer")
local sounder = require("coordinator.sounder")
local apisessions = require("coordinator.session.apisessions")
local apisessions = require("coordinator.session.apisessions")
local COORDINATOR_VERSION = "v0.15.2"
local COORDINATOR_VERSION = "v0.16.0"
local println = util.println
local println_ts = util.println_ts
@ -37,9 +37,9 @@ local log_comms_connecting = coordinator.log_comms_connecting
local cfv = util.new_validator()
cfv.assert_port(config.SCADA_SV_PORT)
cfv.assert_port(config.SCADA_SV_CTL_LISTEN)
cfv.assert_port(config.SCADA_API_LISTEN)
cfv.assert_channel(config.SVR_CHANNEL)
cfv.assert_channel(config.CRD_CHANNEL)
cfv.assert_channel(config.PKT_CHANNEL)
cfv.assert_type_int(config.TRUSTED_RANGE)
cfv.assert_type_num(config.SV_TIMEOUT)
cfv.assert_min(config.SV_TIMEOUT, 2)
@ -148,8 +148,8 @@ local function main()
log.debug("startup> conn watchdog created")
-- start comms, open all channels
local coord_comms = coordinator.comms(COORDINATOR_VERSION, modem, config.SCADA_SV_PORT, config.SCADA_SV_CTL_LISTEN,
config.SCADA_API_LISTEN, config.TRUSTED_RANGE, conn_watchdog)
local coord_comms = coordinator.comms(COORDINATOR_VERSION, modem, config.CRD_CHANNEL, config.SVR_CHANNEL,
config.PKT_CHANNEL, config.TRUSTED_RANGE, conn_watchdog)
log.debug("startup> comms init")
log_comms("comms initialized")
@ -163,7 +163,7 @@ local function main()
-- attempt to connect to the supervisor or exit
local function init_connect_sv()
local tick_waiting, task_done = log_comms_connecting("attempting to connect to configured supervisor on channel " .. config.SCADA_SV_PORT)
local tick_waiting, task_done = log_comms_connecting("attempting to connect to configured supervisor on channel " .. config.SVR_CHANNEL)
-- attempt to establish a connection with the supervisory computer
if not coord_comms.sv_connect(60, tick_waiting, task_done) then
@ -334,7 +334,7 @@ local function main()
apisessions.check_all_watchdogs(param1)
-- notify timer callback dispatcher
tcallbackdsp.handle(param1)
tcd.handle(param1)
end
elseif event == "modem_message" then
-- got a packet

View File

@ -1,4 +1,4 @@
local tcd = require("scada-common.tcallbackdsp")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local iocontrol = require("coordinator.iocontrol")
@ -33,7 +33,7 @@ local period = core.flasher.PERIOD
---@param x integer top left x
---@param y integer top left y
local function new_view(root, x, y)
assert(root.height() >= (y + 24), "main display not of sufficient vertical resolution (add an additional row of monitors)")
assert(root.get_height() >= (y + 24), "main display not of sufficient vertical resolution (add an additional row of monitors)")
local facility = iocontrol.get_db().facility
local units = iocontrol.get_db().units

View File

@ -38,7 +38,7 @@ local function make(parent, x, y, unit)
height = 17
end
assert(parent.height() >= (y + height), "main display not of sufficient vertical resolution (add an additional row of monitors)")
assert(parent.get_height() >= (y + height), "main display not of sufficient vertical resolution (add an additional row of monitors)")
-- bounding box div
local root = Div{parent=parent,x=x,y=y,width=80,height=height}

View File

@ -32,7 +32,7 @@ local function init(main)
local header = TextBox{parent=main,y=1,text="Nuclear Generation Facility SCADA Coordinator",alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=style.header}
local ping = DataIndicator{parent=main,x=1,y=1,label="SVTT",format="%d",value=0,unit="ms",lu_colors=cpair(colors.lightGray, colors.white),width=12,fg_bg=style.header}
-- max length example: "01:23:45 AM - Wednesday, September 28 2022"
local datetime = TextBox{parent=main,x=(header.width()-42),y=1,text="",alignment=TEXT_ALIGN.RIGHT,width=42,height=1,fg_bg=style.header}
local datetime = TextBox{parent=main,x=(header.get_width()-42),y=1,text="",alignment=TEXT_ALIGN.RIGHT,width=42,height=1,fg_bg=style.header}
ping.register(facility.ps, "sv_ping", ping.update)
datetime.register(facility.ps, "date_time", datetime.set_value)
@ -45,12 +45,12 @@ local function init(main)
-- unit overviews
if facility.num_units >= 1 then
uo_1 = unit_overview(main, 2, 3, units[1])
row_1_height = uo_1.height()
row_1_height = uo_1.get_height()
end
if facility.num_units >= 2 then
uo_2 = unit_overview(main, 84, 3, units[2])
row_1_height = math.max(row_1_height, uo_2.height())
row_1_height = math.max(row_1_height, uo_2.get_height())
end
cnc_y_start = cnc_y_start + row_1_height + 1
@ -60,11 +60,11 @@ local function init(main)
local row_2_offset = cnc_y_start
uo_3 = unit_overview(main, 2, row_2_offset, units[3])
cnc_y_start = row_2_offset + uo_3.height() + 1
cnc_y_start = row_2_offset + uo_3.get_height() + 1
if facility.num_units == 4 then
uo_4 = unit_overview(main, 84, row_2_offset, units[4])
cnc_y_start = math.max(cnc_y_start, row_2_offset + uo_4.height() + 1)
cnc_y_start = math.max(cnc_y_start, row_2_offset + uo_4.get_height() + 1)
end
end
@ -73,11 +73,11 @@ local function init(main)
cnc_y_start = cnc_y_start
-- induction matrix and process control interfaces are 24 tall + space needed for divider
local cnc_bottom_align_start = main.height() - 26
local cnc_bottom_align_start = main.get_height() - 26
assert(cnc_bottom_align_start >= cnc_y_start, "main display not of sufficient vertical resolution (add an additional row of monitors)")
TextBox{parent=main,y=cnc_bottom_align_start,text=util.strrep("\x8c", header.width()),alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=cpair(colors.lightGray,colors.gray)}
TextBox{parent=main,y=cnc_bottom_align_start,text=util.strrep("\x8c", header.get_width()),alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=cpair(colors.lightGray,colors.gray)}
cnc_bottom_align_start = cnc_bottom_align_start + 2

View File

@ -12,12 +12,11 @@ local element = {}
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer next line if omitted
---@field offset_x? integer 0 if omitted
---@field offset_y? integer 0 if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
---@alias graphics_args graphics_args_generic
---|waiting_args
@ -46,6 +45,7 @@ local element = {}
---|colormap_args
---|displaybox_args
---|div_args
---|listbox_args
---|multipane_args
---|pipenet_args
---|rectangle_args
@ -62,26 +62,26 @@ local element = {}
---@param args graphics_args arguments
function element.new(args)
local self = {
id = -1,
id = nil, ---@type element_id|nil
elem_type = debug.getinfo(2).name,
define_completed = false,
p_window = nil, ---@type table
position = { x = 1, y = 1 }, ---@type coordinate_2d
child_offset = { x = 0, y = 0 },
bounds = { x1 = 1, y1 = 1, x2 = 1, y2 = 1 }, ---@class element_bounds
next_y = 1,
children = {},
subscriptions = {},
mt = {}
}
---@class graphics_template
---@class graphics_base
local protected = {
enabled = true,
value = nil, ---@type any
window = nil, ---@type table
value = nil, ---@type any
window = nil, ---@type table
content_window = nil, ---@type table|nil
fg_bg = core.cpair(colors.white, colors.black),
frame = core.gframe(1, 1, 1, 1)
frame = core.gframe(1, 1, 1, 1),
children = {}
}
local name_brief = "graphics.element{" .. self.elem_type .. "}: "
@ -101,10 +101,8 @@ function element.new(args)
-------------------------
-- prepare the template
---@param offset_x integer x offset
---@param offset_y integer y offset
---@param next_y integer next line if no y was provided
function protected.prepare_template(offset_x, offset_y, next_y)
function protected.prepare_template(next_y)
-- get frame coordinates/size
if args.gframe ~= nil then
protected.frame.x = args.gframe.x
@ -114,36 +112,18 @@ function element.new(args)
else
local w, h = self.p_window.getSize()
protected.frame.x = args.x or 1
if args.parent ~= nil then
protected.frame.y = args.y or (next_y - offset_y)
else
protected.frame.y = args.y or next_y
end
protected.frame.y = args.y or next_y
protected.frame.w = args.width or w
protected.frame.h = args.height or h
end
-- inner offsets
if args.offset_x ~= nil then self.child_offset.x = args.offset_x end
if args.offset_y ~= nil then self.child_offset.y = args.offset_y end
-- adjust window frame if applicable
local f = protected.frame
local x = f.x
local y = f.y
-- apply offsets
if args.parent ~= nil then
-- constrain to parent inner width/height
local w, h = self.p_window.getSize()
f.w = math.min(f.w, w - ((2 * offset_x) + (f.x - 1)))
f.h = math.min(f.h, h - ((2 * offset_y) + (f.y - 1)))
-- offset x/y
f.x = x + offset_x
f.y = y + offset_y
f.w = math.min(f.w, w - (f.x - 1))
f.h = math.min(f.h, h - (f.y - 1))
end
-- check frame
@ -153,7 +133,7 @@ function element.new(args)
assert(f.h >= 1, name_brief .. "frame height not >= 1")
-- create window
protected.window = window.create(self.p_window, f.x, f.y, f.w, f.h, true)
protected.window = window.create(self.p_window, f.x, f.y, f.w, f.h, args.hidden ~= true)
-- init colors
if args.fg_bg ~= nil then
@ -198,15 +178,15 @@ function element.new(args)
-- luacheck: push ignore
---@diagnostic disable: unused-local, unused-vararg
-- dynamically insert a child element
---@param id string|integer element identifier
---@param elem graphics_element element
function protected.insert(id, elem)
-- handle a child element having been added
---@param id element_id element identifier
---@param child graphics_element child element
function protected.on_added(id, child)
end
-- dynamically remove a child element
---@param id string|integer element identifier
function protected.remove(id)
-- handle a child element having been removed
---@param id element_id element identifier
function protected.on_removed(id)
end
-- handle a mouse event
@ -279,6 +259,14 @@ function element.new(args)
---@return graphics_element element, element_id id
function protected.get() return public, self.id end
-- report completion of element instantiation and get the public interface
---@nodiscard
---@return graphics_element element, element_id id
function protected.complete()
if args.parent ~= nil then args.parent.__child_ready(self.id, public) end
return public, self.id
end
-----------
-- SETUP --
-----------
@ -294,7 +282,8 @@ function element.new(args)
-- prepare the template
if args.parent == nil then
protected.prepare_template(0, 0, 1)
self.id = args.id or "__ROOT__"
protected.prepare_template(1)
else
self.id = args.parent.__add_child(args.id, protected)
end
@ -305,11 +294,21 @@ function element.new(args)
-- get the window object
---@nodiscard
function public.window() return protected.window end
function public.window() return protected.content_window or protected.window end
-- delete this element (hide and unsubscribe from PSIL)
function public.delete()
-- hide + stop animations
local fg_bg = protected.fg_bg
if args.parent ~= nil then
-- grab parent fg/bg so we can clear cleanly as a child element
fg_bg = args.parent.get_fg_bg()
end
-- clear, hide, and stop animations
protected.window.setBackgroundColor(fg_bg.bkg)
protected.window.setTextColor(fg_bg.fgd)
protected.window.clear()
public.hide()
-- unsubscribe from PSIL
@ -319,9 +318,14 @@ function element.new(args)
end
-- delete all children
for k, v in pairs(self.children) do
for k, v in pairs(protected.children) do
v.delete()
self.children[k] = nil
protected.children[k] = nil
end
if args.parent ~= nil then
-- remove self from parent
args.parent.__remove_child(self.id)
end
end
@ -330,41 +334,53 @@ function element.new(args)
-- add a child element
---@nodiscard
---@param key string|nil id
---@param child graphics_template
---@param child graphics_base
---@return integer|string key
function public.__add_child(key, child)
-- offset first automatic placement
if self.next_y <= self.child_offset.y then
self.next_y = self.child_offset.y + 1
end
child.prepare_template(self.child_offset.x, self.child_offset.y, self.next_y)
child.prepare_template(self.next_y)
self.next_y = child.frame.y + child.frame.h
local child_element = child.get()
if key == nil then
table.insert(self.children, child_element)
return #self.children
table.insert(protected.children, child_element)
return #protected.children
else
self.children[key] = child_element
protected.children[key] = child_element
return key
end
end
-- remove a child element
---@param key element_id id
function public.__remove_child(key)
if protected.children[key] ~= nil then
protected.on_removed(key)
protected.children[key] = nil
end
end
-- actions to take upon a child element becoming ready (initial draw/construction completed)
---@param key element_id id
---@param child graphics_element
function public.__child_ready(key, child)
protected.on_added(key, child)
end
-- get a child element
---@nodiscard
---@param id element_id
---@return graphics_element
function public.get_child(id) return self.children[id] end
function public.get_child(id) return protected.children[id] end
-- remove a child element
---@param id element_id
function public.remove(id)
if self.children[id] ~= nil then
self.children[id].delete()
self.children[id] = nil
if protected.children[id] ~= nil then
protected.children[id].delete()
protected.on_removed(id)
protected.children[id] = nil
end
end
@ -373,37 +389,18 @@ function element.new(args)
---@param id element_id
---@return graphics_element|nil element
function public.get_element_by_id(id)
if self.children[id] == nil then
for _, child in pairs(self.children) do
if protected.children[id] == nil then
for _, child in pairs(protected.children) do
local elem = child.get_element_by_id(id)
if elem ~= nil then return elem end
end
else
return self.children[id]
return protected.children[id]
end
return nil
end
-- DYNAMIC CHILD ELEMENTS --
-- insert an element as a contained child<br>
-- this is intended to be used dynamically, and depends on the target element type.<br>
-- not all elements support dynamic children.
---@param id string|integer element identifier
---@param elem graphics_element element
function public.insert_element(id, elem)
protected.insert(id, elem)
end
-- remove an element from contained children<br>
-- this is intended to be used dynamically, and depends on the target element type.<br>
-- not all elements support dynamic children.
---@param id string|integer element identifier
function public.remove_element(id)
protected.remove(id)
end
-- AUTO-PLACEMENT --
-- skip a line for automatically placed elements
@ -437,14 +434,14 @@ function element.new(args)
-- get element width
---@nodiscard
---@return integer width
function public.width()
function public.get_width()
return protected.frame.w
end
-- get element height
---@nodiscard
---@return integer height
function public.height()
function public.get_height()
return protected.frame.h
end
@ -519,7 +516,7 @@ function element.new(args)
-- handle the mouse event then pass to children
protected.handle_mouse(event_T)
for _, child in pairs(self.children) do child.handle_mouse(event_T) end
for _, child in pairs(protected.children) do child.handle_mouse(event_T) end
end
end
@ -545,27 +542,61 @@ function element.new(args)
ps.subscribe(key, func)
end
-- VISIBILITY --
-- VISIBILITY & ANIMATIONS --
-- show the element
function public.show()
-- show the element and enables animations by default
---@param animate? boolean true (default) to automatically resume animations
function public.show(animate)
protected.window.setVisible(true)
protected.start_anim()
for _, child in pairs(self.children) do child.show() end
if animate ~= false then public.animate_all() end
end
-- hide the element
-- hide the element and disables animations<br>
-- this alone does not cause an element to be fully hidden, it only prevents updates from being shown<br>
---@see graphics_element.content_redraw
function public.hide()
protected.stop_anim()
for _, child in pairs(self.children) do child.hide() end
public.freeze_all() -- stop animations for efficiency/performance
protected.window.setVisible(false)
end
-- start/resume animation(s)
function public.animate()
protected.start_anim()
end
-- start/resume animation(s) for this element and all its children<br>
-- only animates if a window is visible
function public.animate_all()
if protected.window.isVisible() then
public.animate()
for _, child in pairs(protected.children) do child.animate_all() end
end
end
-- freeze animation(s)
function public.freeze()
protected.stop_anim()
end
-- freeze animation(s) for this element and all its children
function public.freeze_all()
public.freeze()
for _, child in pairs(protected.children) do child.freeze_all() end
end
-- re-draw the element
function public.redraw()
protected.window.redraw()
end
-- if a content window is set, clears it then re-draws all children
function public.content_redraw()
if protected.content_window ~= nil then
protected.content_window.clear()
for _, child in pairs(protected.children) do child.redraw() end
end
end
return protected
end

View File

@ -1,6 +1,6 @@
-- Loading/Waiting Animation Graphics Element
local tcd = require("scada-common.tcallbackdsp")
local tcd = require("scada-common.tcd")
local element = require("graphics.element")
@ -10,6 +10,7 @@ local element = require("graphics.element")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new waiting animation element
---@param args waiting_args
@ -102,7 +103,7 @@ local function waiting(args)
e.start_anim()
return e.get()
return e.complete()
end
return waiting

View File

@ -9,6 +9,7 @@ local element = require("graphics.element")
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field hidden? boolean true to hide on initial draw
-- new color map
---@param args colormap_args
@ -27,7 +28,7 @@ local function colormap(args)
e.window.setCursorPos(1, 1)
e.window.blit(spaces, bkg, bkg)
return e.get()
return e.complete()
end
return colormap

View File

@ -1,6 +1,6 @@
-- Hazard-bordered Button Graphics Element
local tcd = require("scada-common.tcallbackdsp")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local core = require("graphics.core")
@ -16,6 +16,7 @@ local element = require("graphics.element")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new hazard button
---@param args hazard_button_args
@ -198,7 +199,7 @@ local function hazard_button(args)
-- initial draw of border
draw_border(args.accent)
return e.get()
return e.complete()
end
return hazard_button

View File

@ -23,6 +23,7 @@ local element = require("graphics.element")
---@field y? integer 1 if omitted
---@field height? integer parent height if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new multi button (latch selection, exclusively one button at a time)
---@param args multi_button_args
@ -130,7 +131,7 @@ local function multi_button(args)
-- initial draw
draw()
return e.get()
return e.complete()
end
return multi_button

View File

@ -1,6 +1,6 @@
-- Button Graphics Element
local tcd = require("scada-common.tcallbackdsp")
local tcd = require("scada-common.tcd")
local core = require("graphics.core")
local element = require("graphics.element")
@ -19,6 +19,7 @@ local CLICK_TYPE = core.events.CLICK_TYPE
---@field y? integer 1 if omitted
---@field height? integer parent height if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new push button
---@param args push_button_args
@ -120,7 +121,7 @@ local function push_button(args)
-- initial draw
draw()
return e.get()
return e.complete()
end
return push_button

View File

@ -15,6 +15,7 @@ local element = require("graphics.element")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new radio button list (latch selection, exclusively one button at a time)
---@param args radio_button_args
@ -103,7 +104,7 @@ local function radio_button(args)
-- initial draw
draw()
return e.get()
return e.complete()
end
return radio_button

View File

@ -1,6 +1,6 @@
-- Sidebar Graphics Element
local tcd = require("scada-common.tcallbackdsp")
local tcd = require("scada-common.tcd")
local core = require("graphics.core")
local element = require("graphics.element")
@ -20,6 +20,7 @@ local CLICK_TYPE = core.events.CLICK_TYPE
---@field y? integer 1 if omitted
---@field height? integer parent height if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new sidebar tab selector
---@param args sidebar_args
@ -115,7 +116,7 @@ local function sidebar(args)
-- initial draw
draw(false)
return e.get()
return e.complete()
end
return sidebar

View File

@ -18,6 +18,7 @@ local element = require("graphics.element")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new spinbox control (minimum value is 0)
---@param args spinbox_args
@ -188,7 +189,7 @@ local function spinbox(args)
e.value = 0
set_digits()
return e.get()
return e.complete()
end
return spinbox

View File

@ -15,6 +15,7 @@ local element = require("graphics.element")
---@field y? integer 1 if omitted
---@field height? integer parent height if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new switch button (latch high/low)
---@param args switch_button_args
@ -86,7 +87,7 @@ local function switch_button(args)
draw_state()
end
return e.get()
return e.complete()
end
return switch_button

View File

@ -21,6 +21,7 @@ local element = require("graphics.element")
---@field y? integer 1 if omitted
---@field width? integer parent width if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new tab selector
---@param args tabbar_args
@ -124,7 +125,7 @@ local function tabbar(args)
-- initial draw
draw()
return e.get()
return e.complete()
end
return tabbar

View File

@ -4,19 +4,22 @@ local element = require("graphics.element")
---@class displaybox_args
---@field window table
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new root display box
---@nodiscard
---@param args displaybox_args
---@return graphics_element element, element_id id
local function displaybox(args)
-- create new graphics element base object
return element.new(args).get()
return element.new(args).complete()
end
return displaybox

View File

@ -11,6 +11,7 @@ local element = require("graphics.element")
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new div element
---@nodiscard
@ -18,7 +19,7 @@ local element = require("graphics.element")
---@return graphics_element element, element_id id
local function div(args)
-- create new graphics element base object
return element.new(args).get()
return element.new(args).complete()
end
return div

View File

@ -18,6 +18,7 @@ local flasher = require("graphics.flasher")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new alarm indicator light
---@nodiscard
@ -108,7 +109,7 @@ local function alarm_indicator_light(args)
e.on_update(1)
e.window.write(args.label)
return e.get()
return e.complete()
end
return alarm_indicator_light

View File

@ -163,7 +163,7 @@ local function core_map(args)
-- initial draw
e.on_update(0)
return e.get()
return e.complete()
end
return core_map

View File

@ -17,6 +17,7 @@ local element = require("graphics.element")
---@field y? integer 1 if omitted
---@field width integer length
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new data indicator
---@nodiscard
@ -43,8 +44,9 @@ local function data(args)
e.window.setCursorPos(1, 1)
e.window.write(args.label)
local label_len = string.len(args.label)
local data_start = 1
local value_color = e.fg_bg.fgd
local label_len = string.len(args.label)
local data_start = 1
local clear_width = args.width
if label_len > 0 then
@ -64,7 +66,7 @@ local function data(args)
-- write data
local data_str = util.sprintf(args.format, value)
e.window.setCursorPos(data_start, 1)
e.window.setTextColor(e.fg_bg.fgd)
e.window.setTextColor(value_color)
if args.commas then
e.window.write(util.comma_format(data_str))
else
@ -84,10 +86,17 @@ local function data(args)
---@param val any new value
function e.set_value(val) e.on_update(val) end
-- change the foreground color of the value, or all text if no label/unit colors provided
---@param c color
function e.recolor(c)
value_color = c
e.on_update(e.value)
end
-- initial value draw
e.on_update(args.value)
return e.get()
return e.complete()
end
return data

View File

@ -15,6 +15,7 @@ local element = require("graphics.element")
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new horizontal bar
---@nodiscard
@ -119,7 +120,7 @@ local function hbar(args)
-- initialize to 0
e.on_update(0)
return e.get()
return e.complete()
end
return hbar

View File

@ -18,6 +18,7 @@ local element = require("graphics.element")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new icon indicator
---@nodiscard
@ -68,7 +69,7 @@ local function icon(args)
-- initial icon draw
e.on_update(args.value or 1)
return e.get()
return e.complete()
end
return icon

View File

@ -16,6 +16,7 @@ local flasher = require("graphics.flasher")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new indicator LED
---@nodiscard
@ -94,7 +95,7 @@ local function indicator_led(args)
e.window.write(args.label)
end
return e.get()
return e.complete()
end
return indicator_led

View File

@ -18,6 +18,7 @@ local flasher = require("graphics.flasher")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new dual LED indicator light
---@nodiscard
@ -108,7 +109,7 @@ local function indicator_led_pair(args)
e.window.write(args.label)
end
return e.get()
return e.complete()
end
return indicator_led_pair

View File

@ -11,6 +11,7 @@ local element = require("graphics.element")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new RGB LED indicator light
---@nodiscard
@ -53,7 +54,7 @@ local function indicator_led_rgb(args)
e.window.write(args.label)
end
return e.get()
return e.complete()
end
return indicator_led_rgb

View File

@ -16,6 +16,7 @@ local flasher = require("graphics.flasher")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new indicator light
---@nodiscard
@ -92,7 +93,7 @@ local function indicator_light(args)
e.window.setCursorPos(3, 1)
e.window.write(args.label)
return e.get()
return e.complete()
end
return indicator_light

View File

@ -16,6 +16,7 @@ local element = require("graphics.element")
---@field y? integer 1 if omitted
---@field width integer length
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new power indicator
---@nodiscard
@ -79,7 +80,7 @@ local function power(args)
-- initial value draw
e.on_update(args.value)
return e.get()
return e.complete()
end
return power

View File

@ -17,6 +17,7 @@ local element = require("graphics.element")
---@field y? integer 1 if omitted
---@field width integer length
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new radiation indicator
---@nodiscard
@ -84,7 +85,7 @@ local function rad(args)
-- initial value draw
e.on_update(types.new_zero_radiation_reading())
return e.get()
return e.complete()
end
return rad

View File

@ -18,6 +18,7 @@ local element = require("graphics.element")
---@field y? integer 1 if omitted
---@field height? integer 1 if omitted, must be an odd number
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new state indicator
---@nodiscard
@ -74,7 +75,7 @@ local function state_indicator(args)
-- initial draw
e.on_update(args.value or 1)
return e.get()
return e.complete()
end
return state_indicator

View File

@ -18,6 +18,7 @@ local flasher = require("graphics.flasher")
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new tri-state indicator light
---@nodiscard
@ -105,7 +106,7 @@ local function tristate_indicator_light(args)
e.on_update(1)
e.window.write(args.label)
return e.get()
return e.complete()
end
return tristate_indicator_light

View File

@ -13,6 +13,7 @@ local element = require("graphics.element")
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new vertical bar
---@nodiscard
@ -99,7 +100,7 @@ local function vbar(args)
---@param val number 0.0 to 1.0
function e.set_value(val) e.on_update(val) end
return e.get()
return e.complete()
end
return vbar

View File

@ -0,0 +1,283 @@
-- Scroll-able List Box Display Graphics Element
local tcd = require("scada-common.tcd")
local core = require("graphics.core")
local element = require("graphics.element")
local CLICK_TYPE = core.events.CLICK_TYPE
---@class listbox_args
---@field scroll_height integer height of internal scrolling container (must fit all elements vertically tiled)
---@field item_pad? integer spacing (lines) between items in the list (default 0)
---@field nav_fg_bg? cpair foreground/background colors for scroll arrows and bar area
---@field nav_active? cpair active colors for bar held down or arrow held down
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field width? integer parent width if omitted
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
---@class listbox_item
---@field id string|integer element ID
---@field e graphics_element element
---@field y integer y position
---@field h integer element height
-- new listbox element
---@nodiscard
---@param args listbox_args
---@return graphics_element element, element_id id
local function listbox(args)
-- create new graphics element base object
local e = element.new(args)
-- create content window for child elements
local scroll_frame = window.create(e.window, 1, 1, e.frame.w - 1, args.scroll_height, false)
e.content_window = scroll_frame
-- item list and scroll management
local list = {}
local item_pad = args.item_pad or 0
local scroll_offset = 0
local content_height = 0
local max_down_scroll = 0
-- bar control/tracking variables
local max_bar_height = e.frame.h - 2
local bar_height = 0 -- full height of bar
local bar_bounds = { 0, 0 } -- top and bottom of bar
local bar_is_scaled = false -- if the scrollbar doesn't have a 1:1 ratio with lines
local holding_bar = false -- bar is being held by mouse
local bar_grip_pos = 0 -- where the bar was gripped by mouse down
local mouse_last_y = 0 -- last reported y coordinate of drag
-- draw scroll bar arrows, optionally showing one of them as pressed
---@param pressed_arrow? 1|0|-1 arrow to show as pressed (1 = scroll up, 0 = neither, -1 = scroll down)
local function draw_arrows(pressed_arrow)
local nav_fg_bg = args.nav_fg_bg or e.fg_bg
local active_fg_bg = args.nav_active or nav_fg_bg
-- draw up/down arrows
if pressed_arrow == 1 then
e.window.setTextColor(active_fg_bg.fgd)
e.window.setBackgroundColor(active_fg_bg.bkg)
e.window.setCursorPos(e.frame.w, 1)
e.window.write("\x1e")
e.window.setTextColor(nav_fg_bg.fgd)
e.window.setBackgroundColor(nav_fg_bg.bkg)
e.window.setCursorPos(e.frame.w, e.frame.h)
e.window.write("\x1f")
elseif pressed_arrow == -1 then
e.window.setTextColor(nav_fg_bg.fgd)
e.window.setBackgroundColor(nav_fg_bg.bkg)
e.window.setCursorPos(e.frame.w, 1)
e.window.write("\x1e")
e.window.setTextColor(active_fg_bg.fgd)
e.window.setBackgroundColor(active_fg_bg.bkg)
e.window.setCursorPos(e.frame.w, e.frame.h)
e.window.write("\x1f")
else
e.window.setTextColor(nav_fg_bg.fgd)
e.window.setBackgroundColor(nav_fg_bg.bkg)
e.window.setCursorPos(e.frame.w, 1)
e.window.write("\x1e")
e.window.setCursorPos(e.frame.w, e.frame.h)
e.window.write("\x1f")
end
e.window.setTextColor(e.fg_bg.fgd)
e.window.setBackgroundColor(e.fg_bg.bkg)
end
-- render the scroll bar and re-cacluate height & bounds
local function draw_bar()
local offset = 2 + math.abs(scroll_offset)
bar_height = math.min(max_bar_height + max_down_scroll, max_bar_height)
if bar_height < 1 then
bar_is_scaled = true
-- can't do a 1:1 ratio
-- use minimum size bar with scaled offset
local scroll_progress = scroll_offset / max_down_scroll
offset = 2 + math.floor(scroll_progress * (max_bar_height - 1))
bar_height = 1
else
bar_is_scaled = false
end
bar_bounds = { offset, (bar_height + offset) - 1 }
for i = 2, e.frame.h - 1 do
if (i >= offset and i < (bar_height + offset)) and (bar_height ~= max_bar_height) then
if args.nav_fg_bg ~= nil then
e.window.setBackgroundColor(args.nav_fg_bg.fgd)
else
e.window.setBackgroundColor(e.fg_bg.fgd)
end
else
if args.nav_fg_bg ~= nil then
e.window.setBackgroundColor(args.nav_fg_bg.bkg)
else
e.window.setBackgroundColor(e.fg_bg.bkg)
end
end
e.window.setCursorPos(e.frame.w, i)
e.window.write(" ")
end
e.window.setBackgroundColor(e.fg_bg.bkg)
end
-- update item y positions and move elements
local function update_positions()
local next_y = 1
scroll_frame.setVisible(false)
scroll_frame.setBackgroundColor(e.fg_bg.bkg)
scroll_frame.setTextColor(e.fg_bg.fgd)
scroll_frame.clear()
for i = 1, #list do
local item = list[i] ---@type listbox_item
item.y = next_y
next_y = next_y + item.h + item_pad
item.e.reposition(1, item.y)
item.e.show()
end
content_height = next_y
max_down_scroll = math.min(-1 * (content_height - (e.frame.h + 1 + item_pad)), 0)
if scroll_offset < max_down_scroll then scroll_offset = max_down_scroll end
scroll_frame.reposition(1, 1 + scroll_offset)
scroll_frame.setVisible(true)
draw_bar()
end
-- determine where to scroll to based on a scrollbar being dragged without a 1:1 relationship
---@param direction -1|1 negative 1 to scroll up by one, positive 1 to scroll down by one
local function scaled_bar_scroll(direction)
local scroll_progress = scroll_offset / max_down_scroll
local bar_position = math.floor(scroll_progress * (max_bar_height - 1))
-- check what moving the scroll bar up or down would mean for the scroll progress
scroll_progress = (bar_position + direction) / (max_bar_height - 1)
return math.max(math.floor(scroll_progress * max_down_scroll), max_down_scroll)
end
-- scroll down the list
local function scroll_down(scaled)
if scroll_offset > max_down_scroll then
if scaled then
scroll_offset = scaled_bar_scroll(1)
else
scroll_offset = scroll_offset - 1
end
update_positions()
end
end
-- scroll up the list
local function scroll_up(scaled)
if scroll_offset < 0 then
if scaled then
scroll_offset = scaled_bar_scroll(-1)
else
scroll_offset = scroll_offset + 1
end
update_positions()
end
end
-- handle a child element having been added to the list
---@param id element_id element identifier
---@param child graphics_element child element
function e.on_added(id, child)
table.insert(list, { id = id, e = child, y = 0, h = child.get_height() })
update_positions()
end
-- handle a child element having been removed from the list
---@param id element_id element identifier
function e.on_removed(id)
for idx, elem in ipairs(list) do
if elem.id == id then
table.remove(list, idx)
update_positions()
return
end
end
end
-- handle mouse interaction
---@param event mouse_interaction mouse event
function e.handle_mouse(event)
if e.enabled then
if event.type == CLICK_TYPE.TAP then
if event.current.x == e.frame.w then
if event.current.y == 1 or event.current.y < bar_bounds[1] then
draw_arrows(1)
scroll_up()
if args.nav_active ~= nil then tcd.dispatch(0.25, function () draw_arrows(0) end) end
elseif event.current.y == e.frame.h or event.current.y > bar_bounds[2] then
draw_arrows(-1)
scroll_down()
if args.nav_active ~= nil then tcd.dispatch(0.25, function () draw_arrows(0) end) end
end
end
elseif event.type == CLICK_TYPE.DOWN then
if event.current.x == e.frame.w then
if event.current.y == 1 or event.current.y < bar_bounds[1] then
draw_arrows(1)
scroll_up()
elseif event.current.y == e.frame.h or event.current.y > bar_bounds[2] then
draw_arrows(-1)
scroll_down()
else
-- clicked on bar
holding_bar = true
bar_grip_pos = event.current.y - bar_bounds[1]
mouse_last_y = event.current.y
end
end
elseif event.type == CLICK_TYPE.UP then
holding_bar = false
draw_arrows(0)
elseif event.type == CLICK_TYPE.DRAG then
if holding_bar then
-- if mouse is within vertical frame, including the grip point
if event.current.y > (1 + bar_grip_pos) and event.current.y <= ((e.frame.h - bar_height) + bar_grip_pos) then
if event.current.y < mouse_last_y then
scroll_up(bar_is_scaled)
elseif event.current.y > mouse_last_y then
scroll_down(bar_is_scaled)
end
mouse_last_y = event.current.y
end
end
elseif event.type == CLICK_TYPE.SCROLL_DOWN then
scroll_down()
elseif event.type == CLICK_TYPE.SCROLL_UP then
scroll_up()
end
end
end
draw_arrows(0)
draw_bar()
return e.complete()
end
return listbox

View File

@ -12,6 +12,7 @@ local element = require("graphics.element")
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new multipane element
---@nodiscard
@ -36,7 +37,7 @@ local function multipane(args)
e.set_value(1)
return e.get()
return e.complete()
end
return multipane

View File

@ -12,6 +12,7 @@ local element = require("graphics.element")
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer 1 if omitted
---@field hidden? boolean true to hide on initial draw
-- new pipe network
---@param args pipenet_args
@ -141,7 +142,7 @@ local function pipenet(args)
end
return e.get()
return e.complete()
end
return pipenet

View File

@ -16,6 +16,7 @@ local element = require("graphics.element")
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new rectangle
---@param args rectangle_args
@ -30,27 +31,35 @@ local function rectangle(args)
end
-- offset children
local offset_x = 0
local offset_y = 0
if args.border ~= nil then
args.offset_x = args.border.width
args.offset_y = args.border.width
offset_x = args.border.width
offset_y = args.border.width
-- slightly different y offset if the border is set to even
if args.border.even then
local width_x2 = (2 * args.border.width)
args.offset_y = math.floor(width_x2 / 3) + util.trinary(width_x2 % 3 > 0, 1, 0)
offset_y = math.floor(width_x2 / 3) + util.trinary(width_x2 % 3 > 0, 1, 0)
end
end
-- create new graphics element base object
local e = element.new(args)
-- create content window for child elements
e.content_window = window.create(e.window, 1 + offset_x, 1 + offset_y, e.frame.w - (2 * offset_x), e.frame.h - (2 * offset_y))
e.content_window.setBackgroundColor(e.fg_bg.bkg)
e.content_window.setTextColor(e.fg_bg.fgd)
e.content_window.clear()
-- draw bordered box if requested
-- element constructor will have drawn basic colored rectangle regardless
if args.border ~= nil then
e.window.setCursorPos(1, 1)
local border_width = args.offset_x
local border_height = args.offset_y
local border_width = offset_x
local border_height = offset_y
local border_blit = colors.toBlit(args.border.color)
local width_x2 = border_width * 2
local inner_width = e.frame.w - width_x2
@ -177,7 +186,7 @@ local function rectangle(args)
end
end
return e.get()
return e.complete()
end
return rectangle

View File

@ -18,6 +18,7 @@ local TEXT_ALIGN = core.TEXT_ALIGN
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new text box
---@param args textbox_args
@ -64,7 +65,7 @@ local function textbox(args)
display_text(val)
end
return e.get()
return e.complete()
end
return textbox

View File

@ -16,6 +16,7 @@ local element = require("graphics.element")
---@field height? integer parent height if omitted
---@field gframe? graphics_frame frame instead of x/y/width/height
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new tiling box
---@param args tiling_args
@ -81,7 +82,7 @@ local function tiling(args)
if inner_width % 2 == 0 then alternator = not alternator end
end
return e.get()
return e.complete()
end
return tiling

View File

@ -2,7 +2,7 @@
-- Indicator Light Flasher
--
local tcd = require("scada-common.tcallbackdsp")
local tcd = require("scada-common.tcd")
local flasher = {}

View File

@ -111,7 +111,7 @@ f.close()
if len(sys.argv) > 1 and sys.argv[1] == "shields":
# write all the JSON files for shields.io
for key, version in final_manifest["versions"].items():
f = open("./shields/" + key + ".json", "w")
f = open("./deploy/" + key + ".json", "w")
if version.find("alpha") >= 0:
color = "yellow"

File diff suppressed because one or more lines are too long

View File

@ -1,11 +1,11 @@
local config = {}
-- port of the SCADA supervisor
config.SCADA_SV_PORT = 16100
-- port for SCADA coordinator API access
config.SCADA_API_PORT = 16200
-- port to listen to incoming packets FROM servers
config.LISTEN_PORT = 16201
-- supervisor comms channel
config.SVR_CHANNEL = 16240
-- coordinator comms channel
config.CRD_CHANNEL = 16243
-- pocket comms channel
config.PKT_CHANNEL = 16244
-- max trusted modem message distance (0 to disable check)
config.TRUSTED_RANGE = 0
-- time in seconds (>= 2) before assuming a remote device is no longer active

View File

@ -18,22 +18,24 @@ local pocket = {}
---@nodiscard
---@param version string pocket version
---@param modem table modem device
---@param local_port integer local pocket port
---@param sv_port integer port of supervisor
---@param api_port integer port of coordinator API
---@param pkt_channel integer pocket comms channel
---@param svr_channel integer supervisor access channel
---@param crd_channel integer coordinator access channel
---@param range integer trusted device connection range
---@param sv_watchdog watchdog
---@param api_watchdog watchdog
function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_watchdog, api_watchdog)
function pocket.comms(version, modem, pkt_channel, svr_channel, crd_channel, range, sv_watchdog, api_watchdog)
local self = {
sv = {
linked = false,
addr = comms.BROADCAST,
seq_num = 0,
r_seq_num = nil, ---@type nil|integer
last_est_ack = ESTABLISH_ACK.ALLOW
},
api = {
linked = false,
addr = comms.BROADCAST,
seq_num = 0,
r_seq_num = nil, ---@type nil|integer
last_est_ack = ESTABLISH_ACK.ALLOW
@ -48,7 +50,7 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
-- configure modem channels
local function _conf_channels()
modem.closeAll()
modem.open(local_port)
modem.open(pkt_channel)
end
_conf_channels()
@ -61,9 +63,9 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
local pkt = comms.mgmt_packet()
pkt.make(msg_type, msg)
s_pkt.make(self.sv.seq_num, PROTOCOL.SCADA_MGMT, pkt.raw_sendable())
s_pkt.make(self.sv.addr, self.sv.seq_num, PROTOCOL.SCADA_MGMT, pkt.raw_sendable())
modem.transmit(sv_port, local_port, s_pkt.raw_sendable())
modem.transmit(svr_channel, pkt_channel, s_pkt.raw_sendable())
self.sv.seq_num = self.sv.seq_num + 1
end
@ -75,9 +77,9 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
local pkt = comms.mgmt_packet()
pkt.make(msg_type, msg)
s_pkt.make(self.api.seq_num, PROTOCOL.SCADA_MGMT, pkt.raw_sendable())
s_pkt.make(self.api.addr, self.api.seq_num, PROTOCOL.SCADA_MGMT, pkt.raw_sendable())
modem.transmit(api_port, local_port, s_pkt.raw_sendable())
modem.transmit(crd_channel, pkt_channel, s_pkt.raw_sendable())
self.api.seq_num = self.api.seq_num + 1
end
@ -89,9 +91,9 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
-- local pkt = comms.capi_packet()
-- pkt.make(msg_type, msg)
-- s_pkt.make(self.api.seq_num, PROTOCOL.COORD_API, pkt.raw_sendable())
-- s_pkt.make(self.api.addr, self.api.seq_num, PROTOCOL.COORD_API, pkt.raw_sendable())
-- modem.transmit(api_port, local_port, s_pkt.raw_sendable())
-- modem.transmit(crd_channel, pkt_channel, s_pkt.raw_sendable())
-- self.api.seq_num = self.api.seq_num + 1
-- end
@ -133,6 +135,8 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
function public.close_sv()
sv_watchdog.cancel()
self.sv.linked = false
self.sv.r_seq_num = nil
self.sv.addr = comms.BROADCAST
_send_sv(SCADA_MGMT_TYPE.CLOSE, {})
end
@ -140,6 +144,8 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
function public.close_api()
api_watchdog.cancel()
self.api.linked = false
self.api.r_seq_num = nil
self.api.addr = comms.BROADCAST
_send_crd(SCADA_MGMT_TYPE.CLOSE, {})
end
@ -214,18 +220,23 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
---@param packet mgmt_frame|capi_frame|nil
function public.handle_packet(packet)
if packet ~= nil then
local l_port = packet.scada_frame.local_port()
local r_port = packet.scada_frame.remote_port()
local l_chan = packet.scada_frame.local_channel()
local r_chan = packet.scada_frame.remote_channel()
local protocol = packet.scada_frame.protocol()
local src_addr = packet.scada_frame.src_addr()
if l_port ~= local_port then
log.debug("received packet on unconfigured channel " .. l_port, true)
elseif r_port == api_port then
if l_chan ~= pkt_channel then
log.debug("received packet on unconfigured channel " .. l_chan, true)
elseif r_chan == crd_channel then
-- check sequence number
if self.api.r_seq_num == nil then
self.api.r_seq_num = packet.scada_frame.seq_num()
elseif self.connected and ((self.api.r_seq_num + 1) ~= packet.scada_frame.seq_num()) then
log.warning("sequence out-of-order: last = " .. self.api.r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
log.warning("sequence out-of-order (API): last = " .. self.api.r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
return
elseif self.api.linked and (src_addr ~= self.api.addr) then
log.debug("received packet from unknown computer " .. src_addr .. " while linked (API expected " .. self.api.addr ..
"); channel in use by another system?")
return
else
self.api.r_seq_num = packet.scada_frame.seq_num()
@ -247,6 +258,7 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
log.info("coordinator connection established")
self.establish_delay_counter = 0
self.api.linked = true
self.api.addr = src_addr
if self.sv.linked then
coreio.report_link_state(LINK_STATE.LINKED)
@ -294,6 +306,8 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
-- handle session close
api_watchdog.cancel()
self.api.linked = false
self.api.r_seq_num = nil
self.api.addr = comms.BROADCAST
log.info("coordinator server connection closed by remote host")
else
log.debug("received unknown SCADA_MGMT packet type " .. packet.type .. " from coordinator")
@ -304,12 +318,16 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
else
log.debug("illegal packet type " .. protocol .. " from coordinator", true)
end
elseif r_port == sv_port then
elseif r_chan == svr_channel then
-- check sequence number
if self.sv.r_seq_num == nil then
self.sv.r_seq_num = packet.scada_frame.seq_num()
elseif self.connected and ((self.sv.r_seq_num + 1) ~= packet.scada_frame.seq_num()) then
log.warning("sequence out-of-order: last = " .. self.sv.r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
log.warning("sequence out-of-order (SVR): last = " .. self.sv.r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
return
elseif self.sv.linked and (src_addr ~= self.sv.addr) then
log.debug("received packet from unknown computer " .. src_addr .. " while linked (SVR expected " .. self.sv.addr ..
"); channel in use by another system?")
return
else
self.sv.r_seq_num = packet.scada_frame.seq_num()
@ -330,6 +348,7 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
log.info("supervisor connection established")
self.establish_delay_counter = 0
self.sv.linked = true
self.sv.addr = src_addr
if self.api.linked then
coreio.report_link_state(LINK_STATE.LINKED)
@ -377,6 +396,8 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
-- handle session close
sv_watchdog.cancel()
self.sv.linked = false
self.sv.r_seq_num = nil
self.sv.addr = comms.BROADCAST
log.info("supervisor server connection closed by remote host")
else
log.debug("received unknown SCADA_MGMT packet type " .. packet.type .. " from supervisor")
@ -388,7 +409,7 @@ function pocket.comms(version, modem, local_port, sv_port, api_port, range, sv_w
log.debug("illegal packet type " .. protocol .. " from supervisor", true)
end
else
log.debug("received packet from unconfigured channel " .. r_port, true)
log.debug("received packet from unconfigured channel " .. r_chan, true)
end
end
end

View File

@ -4,20 +4,20 @@
require("/initenv").init_env()
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local ppm = require("scada-common.ppm")
local tcallbackdsp = require("scada-common.tcallbackdsp")
local util = require("scada-common.util")
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local core = require("graphics.core")
local core = require("graphics.core")
local config = require("pocket.config")
local coreio = require("pocket.coreio")
local pocket = require("pocket.pocket")
local renderer = require("pocket.renderer")
local config = require("pocket.config")
local coreio = require("pocket.coreio")
local pocket = require("pocket.pocket")
local renderer = require("pocket.renderer")
local POCKET_VERSION = "alpha-v0.3.2"
local POCKET_VERSION = "alpha-v0.4.4"
local println = util.println
local println_ts = util.println_ts
@ -28,9 +28,9 @@ local println_ts = util.println_ts
local cfv = util.new_validator()
cfv.assert_port(config.SCADA_SV_PORT)
cfv.assert_port(config.SCADA_API_PORT)
cfv.assert_port(config.LISTEN_PORT)
cfv.assert_channel(config.SVR_CHANNEL)
cfv.assert_channel(config.CRD_CHANNEL)
cfv.assert_channel(config.PKT_CHANNEL)
cfv.assert_type_int(config.TRUSTED_RANGE)
cfv.assert_type_num(config.COMMS_TIMEOUT)
cfv.assert_min(config.COMMS_TIMEOUT, 2)
@ -89,8 +89,8 @@ local function main()
log.debug("startup> conn watchdogs created")
-- start comms, open all channels
local pocket_comms = pocket.comms(POCKET_VERSION, modem, config.LISTEN_PORT, config.SCADA_SV_PORT,
config.SCADA_API_PORT, config.TRUSTED_RANGE, conn_wd.sv, conn_wd.api)
local pocket_comms = pocket.comms(POCKET_VERSION, modem, config.PKT_CHANNEL, config.SVR_CHANNEL,
config.CRD_CHANNEL, config.TRUSTED_RANGE, conn_wd.sv, conn_wd.api)
log.debug("startup> comms init")
-- base loop clock (2Hz, 10 ticks)
@ -120,54 +120,54 @@ local function main()
conn_wd.sv.feed()
conn_wd.api.feed()
log.debug("startup> conn watchdog started")
end
-- main event loop
while ui_ok do
local event, param1, param2, param3, param4, param5 = util.pull_event()
-- main event loop
while true do
local event, param1, param2, param3, param4, param5 = util.pull_event()
-- handle event
if event == "timer" then
if loop_clock.is_clock(param1) then
-- main loop tick
-- handle event
if event == "timer" then
if loop_clock.is_clock(param1) then
-- main loop tick
-- relink if necessary
pocket_comms.link_update()
-- relink if necessary
pocket_comms.link_update()
loop_clock.start()
elseif conn_wd.sv.is_timer(param1) then
-- supervisor watchdog timeout
log.info("supervisor server timeout")
pocket_comms.close_sv()
elseif conn_wd.api.is_timer(param1) then
-- coordinator watchdog timeout
log.info("coordinator api server timeout")
pocket_comms.close_api()
else
-- a non-clock/main watchdog timer event
-- notify timer callback dispatcher
tcallbackdsp.handle(param1)
loop_clock.start()
elseif conn_wd.sv.is_timer(param1) then
-- supervisor watchdog timeout
log.info("supervisor server timeout")
pocket_comms.close_sv()
elseif conn_wd.api.is_timer(param1) then
-- coordinator watchdog timeout
log.info("coordinator api server timeout")
pocket_comms.close_api()
else
-- a non-clock/main watchdog timer event
-- notify timer callback dispatcher
tcd.handle(param1)
end
elseif event == "modem_message" then
-- got a packet
local packet = pocket_comms.parse_packet(param1, param2, param3, param4, param5)
pocket_comms.handle_packet(packet)
elseif event == "mouse_click" or event == "mouse_up" or event == "mouse_drag" or event == "mouse_scroll" then
-- handle a monitor touch event
renderer.handle_mouse(core.events.new_mouse_event(event, param1, param2, param3))
end
-- check for termination request
if event == "terminate" or ppm.should_terminate() then
log.info("terminate requested, closing server connections...")
pocket_comms.close()
log.info("connections closed")
break
end
elseif event == "modem_message" then
-- got a packet
local packet = pocket_comms.parse_packet(param1, param2, param3, param4, param5)
pocket_comms.handle_packet(packet)
elseif event == "mouse_click" or event == "mouse_up" or event == "mouse_drag" or event == "mouse_scroll" then
-- handle a monitor touch event
renderer.handle_mouse(core.events.new_mouse_event(event, param1, param2, param3))
end
-- check for termination request
if event == "terminate" or ppm.should_terminate() then
log.info("terminate requested, closing server connections...")
pocket_comms.close()
log.info("connections closed")
break
end
renderer.close_ui()
end
renderer.close_ui()
println_ts("exited")
log.info("exited")
end

View File

@ -25,7 +25,7 @@ local function init(parent, y, is_api)
-- bounding box div
local box = Div{parent=root,x=1,y=y,height=5}
local waiting_x = math.floor(parent.width() / 2) - 1
local waiting_x = math.floor(parent.get_width() / 2) - 1
if is_api then
WaitingAnim{parent=box,x=waiting_x,y=1,fg_bg=cpair(colors.blue,style.root.bkg)}

View File

@ -8,11 +8,11 @@ local style = require("pocket.ui.style")
local conn_waiting = require("pocket.ui.components.conn_waiting")
local home_page = require("pocket.ui.components.home_page")
local unit_page = require("pocket.ui.components.unit_page")
local reactor_page = require("pocket.ui.components.reactor_page")
local boiler_page = require("pocket.ui.components.boiler_page")
local turbine_page = require("pocket.ui.components.turbine_page")
local home_page = require("pocket.ui.pages.home_page")
local unit_page = require("pocket.ui.pages.unit_page")
local reactor_page = require("pocket.ui.pages.reactor_page")
local boiler_page = require("pocket.ui.pages.boiler_page")
local turbine_page = require("pocket.ui.pages.turbine_page")
local core = require("graphics.core")

View File

@ -9,10 +9,10 @@ config.REACTOR_ID = 1
-- when emergency coolant is needed due to low coolant
-- config.EMERGENCY_COOL = { side = "right", color = nil }
-- port to send packets TO server
config.SERVER_PORT = 16000
-- port to listen to incoming packets FROM server
config.LISTEN_PORT = 14001
-- supervisor comms channel
config.SVR_CHANNEL = 16240
-- PLC comms channel
config.PLC_CHANNEL = 16241
-- max trusted modem message distance (0 to disable check)
config.TRUSTED_RANGE = 0
-- time in seconds (>= 2) before assuming a remote device is no longer active

View File

@ -2,6 +2,7 @@
-- Main SCADA Coordinator GUI
--
local types = require("scada-common.types")
local util = require("scada-common.util")
local config = require("reactor-plc.config")
@ -49,7 +50,7 @@ local function init(panel)
local reactor = LEDPair{parent=system,label="REACTOR",off=colors.red,c1=colors.yellow,c2=colors.green}
local modem = LED{parent=system,label="MODEM",colors=cpair(colors.green,colors.green_off)}
local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.orange,colors.yellow,colors.gray}}
network.update(5)
network.update(types.PANEL_LINK_STATE.DISCONNECTED)
system.line_break()
reactor.register(databus.ps, "reactor_dev_state", reactor.update)
@ -69,6 +70,10 @@ local function init(panel)
rt_cmrx.register(databus.ps, "routine__comms_rx", rt_cmrx.update)
rt_sctl.register(databus.ps, "routine__spctl", rt_sctl.update)
---@diagnostic disable-next-line: undefined-field
local comp_id = util.sprintf("(%d)", os.getComputerID())
TextBox{parent=system,x=9,y=5,width=6,height=1,text=comp_id,fg_bg=cpair(colors.lightGray,colors.ivory)}
--
-- status & controls
--

View File

@ -446,14 +446,15 @@ end
---@param id integer reactor ID
---@param version string PLC version
---@param modem table modem device
---@param local_port integer local listening port
---@param server_port integer remote server port
---@param plc_channel integer PLC comms channel
---@param svr_channel integer supervisor server channel
---@param range integer trusted device connection range
---@param reactor table reactor device
---@param rps rps RPS reference
---@param conn_watchdog watchdog watchdog reference
function plc.comms(id, version, modem, local_port, server_port, range, reactor, rps, conn_watchdog)
function plc.comms(id, version, modem, plc_channel, svr_channel, range, reactor, rps, conn_watchdog)
local self = {
sv_addr = comms.BROADCAST,
seq_num = 0,
r_seq_num = nil,
scrammed = false,
@ -472,7 +473,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
-- configure modem channels
local function _conf_channels()
modem.closeAll()
modem.open(local_port)
modem.open(plc_channel)
end
_conf_channels()
@ -485,9 +486,9 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
local r_pkt = comms.rplc_packet()
r_pkt.make(id, msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.RPLC, r_pkt.raw_sendable())
s_pkt.make(self.sv_addr, self.seq_num, PROTOCOL.RPLC, r_pkt.raw_sendable())
modem.transmit(server_port, local_port, s_pkt.raw_sendable())
modem.transmit(svr_channel, plc_channel, s_pkt.raw_sendable())
self.seq_num = self.seq_num + 1
end
@ -499,9 +500,9 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(self.sv_addr, self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
modem.transmit(server_port, local_port, s_pkt.raw_sendable())
modem.transmit(svr_channel, plc_channel, s_pkt.raw_sendable())
self.seq_num = self.seq_num + 1
end
@ -667,9 +668,11 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
-- unlink from the server
function public.unlink()
self.sv_addr = comms.BROADCAST
self.linked = false
self.r_seq_num = nil
self.status_cache = nil
databus.tx_link_state(types.PANEL_LINK_STATE.DISCONNECTED)
end
-- close the connection to the server
@ -731,7 +734,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
end
end
-- parse an RPLC packet
-- parse a packet
---@nodiscard
---@param side string
---@param sender integer
@ -760,14 +763,14 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
pkt = mgmt_pkt.get()
end
else
log.debug("illegal packet type " .. s_pkt.protocol(), true)
log.debug("unsupported packet type " .. s_pkt.protocol(), true)
end
end
return pkt
end
-- handle an RPLC packet
-- handle RPLC and MGMT packets
---@param packet rplc_frame|mgmt_frame packet frame
---@param plc_state plc_state PLC state
---@param setpoints setpoints setpoint control table
@ -775,16 +778,22 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
-- print a log message to the terminal as long as the UI isn't running
local function println_ts(message) if not plc_state.fp_ok then util.println_ts(message) end end
local l_port = packet.scada_frame.local_port()
local protocol = packet.scada_frame.protocol()
local l_chan = packet.scada_frame.local_channel()
local src_addr = packet.scada_frame.src_addr()
-- handle packets now that we have prints setup
if l_port == local_port then
if l_chan == plc_channel then
-- check sequence number
if self.r_seq_num == nil then
self.r_seq_num = packet.scada_frame.seq_num()
elseif self.linked and ((self.r_seq_num + 1) ~= packet.scada_frame.seq_num()) then
log.warning("sequence out-of-order: last = " .. self.r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
return
elseif self.linked and (src_addr ~= self.sv_addr) then
log.debug("received packet from unknown computer " .. src_addr .. " while linked (expected " .. self.sv_addr ..
"); channel in use by another system?")
return
else
self.r_seq_num = packet.scada_frame.seq_num()
end
@ -792,11 +801,10 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
-- feed the watchdog first so it doesn't uhh...eat our packets :)
conn_watchdog.feed()
local protocol = packet.scada_frame.protocol()
-- handle packet
if protocol == PROTOCOL.RPLC then
---@cast packet rplc_frame
-- if linked, only accept packets from configured supervisor
if self.linked then
if packet.type == RPLC_TYPE.STATUS then
-- request of full status, clear cache first
@ -933,6 +941,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
end
elseif protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- if linked, only accept packets from configured supervisor
if self.linked then
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- link request confirmation
@ -945,22 +954,26 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
self.status_cache = nil
_send_struct()
public.send_status(plc_state.no_reactor, plc_state.reactor_formed)
log.debug("re-sent initial status data")
elseif est_ack == ESTABLISH_ACK.DENY then
println_ts("received unsolicited link denial, unlinking")
log.warning("unsolicited establish request denied")
elseif est_ack == ESTABLISH_ACK.COLLISION then
println_ts("received unsolicited link collision, unlinking")
log.warning("unsolicited establish request collision")
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
println_ts("received unsolicited link version mismatch, unlinking")
log.warning("unsolicited establish request version mismatch")
log.debug("re-sent initial status data due to re-establish")
else
println_ts("invalid unsolicited link response")
log.debug("unsolicited unknown establish request response")
end
if est_ack == ESTABLISH_ACK.DENY then
println_ts("received unsolicited link denial, unlinking")
log.warning("unsolicited establish request denied")
elseif est_ack == ESTABLISH_ACK.COLLISION then
println_ts("received unsolicited link collision, unlinking")
log.warning("unsolicited establish request collision")
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
println_ts("received unsolicited link version mismatch, unlinking")
log.warning("unsolicited establish request version mismatch")
else
println_ts("invalid unsolicited link response")
log.debug("unsolicited unknown establish request response")
end
self.linked = est_ack == ESTABLISH_ACK.ALLOW
-- unlink
self.sv_addr = comms.BROADCAST
self.linked = false
end
-- clear this since this is for something that was unsolicited
self.last_est_ack = ESTABLISH_ACK.ALLOW
@ -980,7 +993,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
log.warning("PLC KEEP_ALIVE trip time > 750ms (" .. trip_time .. "ms)")
end
-- log.debug("RPLC RTT = " .. trip_time .. "ms")
-- log.debug("PLC RTT = " .. trip_time .. "ms")
_send_keep_alive_ack(timestamp)
else
@ -1002,9 +1015,11 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
if est_ack == ESTABLISH_ACK.ALLOW then
println_ts("linked!")
log.info("supervisor establish request approved, PLC is linked")
log.info("supervisor establish request approved, linked to SV (CID#" .. src_addr .. ")")
-- reset remote sequence number and cache
-- link + reset remote sequence number and cache
self.sv_addr = src_addr
self.linked = true
self.r_seq_num = nil
self.status_cache = nil
@ -1012,23 +1027,28 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
public.send_status(plc_state.no_reactor, plc_state.reactor_formed)
log.debug("sent initial status data")
elseif self.last_est_ack ~= est_ack then
if est_ack == ESTABLISH_ACK.DENY then
println_ts("link request denied, retrying...")
log.info("supervisor establish request denied, retrying")
elseif est_ack == ESTABLISH_ACK.COLLISION then
println_ts("reactor PLC ID collision (check config), retrying...")
log.warning("establish request collision, retrying")
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
println_ts("supervisor version mismatch (try updating), retrying...")
log.warning("establish request version mismatch, retrying")
else
println_ts("invalid link response, bad channel? retrying...")
log.error("unknown establish request response, retrying")
else
if self.last_est_ack ~= est_ack then
if est_ack == ESTABLISH_ACK.DENY then
println_ts("link request denied, retrying...")
log.info("supervisor establish request denied, retrying")
elseif est_ack == ESTABLISH_ACK.COLLISION then
println_ts("reactor PLC ID collision (check config), retrying...")
log.warning("establish request collision, retrying")
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
println_ts("supervisor version mismatch (try updating), retrying...")
log.warning("establish request version mismatch, retrying")
else
println_ts("invalid link response, bad channel? retrying...")
log.error("unknown establish request response, retrying")
end
end
-- unlink
self.sv_addr = comms.BROADCAST
self.linked = false
end
self.linked = est_ack == ESTABLISH_ACK.ALLOW
self.last_est_ack = est_ack
-- report link state
@ -1044,7 +1064,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
log.error("illegal packet type " .. protocol, true)
end
else
log.debug("received packet on unconfigured channel " .. l_port, true)
log.debug("received packet on unconfigured channel " .. l_chan, true)
end
end

View File

@ -18,7 +18,7 @@ local plc = require("reactor-plc.plc")
local renderer = require("reactor-plc.renderer")
local threads = require("reactor-plc.threads")
local R_PLC_VERSION = "v1.3.2"
local R_PLC_VERSION = "v1.4.5"
local println = util.println
local println_ts = util.println_ts
@ -31,8 +31,8 @@ local cfv = util.new_validator()
cfv.assert_type_bool(config.NETWORKED)
cfv.assert_type_int(config.REACTOR_ID)
cfv.assert_port(config.SERVER_PORT)
cfv.assert_port(config.LISTEN_PORT)
cfv.assert_channel(config.SVR_CHANNEL)
cfv.assert_channel(config.PLC_CHANNEL)
cfv.assert_type_int(config.TRUSTED_RANGE)
cfv.assert_type_num(config.COMMS_TIMEOUT)
cfv.assert_min(config.COMMS_TIMEOUT, 2)
@ -197,7 +197,7 @@ local function main()
log.debug("init> conn watchdog started")
-- start comms
smem_sys.plc_comms = plc.comms(config.REACTOR_ID, R_PLC_VERSION, smem_dev.modem, config.LISTEN_PORT, config.SERVER_PORT,
smem_sys.plc_comms = plc.comms(config.REACTOR_ID, R_PLC_VERSION, smem_dev.modem, config.PLC_CHANNEL, config.SVR_CHANNEL,
config.TRUSTED_RANGE, smem_dev.reactor, smem_sys.rps, smem_sys.conn_watchdog)
log.debug("init> comms init")
else

View File

@ -1,13 +1,13 @@
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local ppm = require("scada-common.ppm")
local tcallbackdsp = require("scada-common.tcallbackdsp")
local util = require("scada-common.util")
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local databus = require("reactor-plc.databus")
local renderer = require("reactor-plc.renderer")
local databus = require("reactor-plc.databus")
local renderer = require("reactor-plc.renderer")
local core = require("graphics.core")
local core = require("graphics.core")
local threads = {}
@ -157,7 +157,7 @@ function threads.thread__main(smem, init)
smem.q.mq_rps.push_command(MQ__RPS_CMD.TRIP_TIMEOUT)
elseif event == "timer" then
-- notify timer callback dispatcher if no other timer case claimed this event
tcallbackdsp.handle(param1)
tcd.handle(param1)
elseif event == "peripheral_detach" then
-- peripheral disconnect
local type, device = ppm.handle_unmount(param1)

View File

@ -2,11 +2,11 @@ local rsio = require("scada-common.rsio")
local config = {}
-- port to send packets TO server
config.SERVER_PORT = 16000
-- port to listen to incoming packets FROM server
config.LISTEN_PORT = 15001
-- max trusted modem message distance (< 1 to disable check)
-- supervisor comms channel
config.SVR_CHANNEL = 16240
-- RTU/MODBUS comms channel
config.RTU_CHANNEL = 16242
-- max trusted modem message distance (0 to disable check)
config.TRUSTED_RANGE = 0
-- time in seconds (>= 2) before assuming a remote device is no longer active
config.COMMS_TIMEOUT = 5

View File

@ -2,6 +2,7 @@
-- Main SCADA Coordinator GUI
--
local types = require("scada-common.types")
local util = require("scada-common.util")
local databus = require("rtu.databus")
@ -44,7 +45,7 @@ local function init(panel, units)
local system = Div{parent=panel,width=14,height=18,x=2,y=3}
local on = LED{parent=system,label="POWER",colors=cpair(colors.green,colors.red)}
local on = LED{parent=system,label="STATUS",colors=cpair(colors.green,colors.red)}
local heartbeat = LED{parent=system,label="HEARTBEAT",colors=cpair(colors.green,colors.green_off)}
on.update(true)
system.line_break()
@ -53,7 +54,7 @@ local function init(panel, units)
local modem = LED{parent=system,label="MODEM",colors=cpair(colors.green,colors.green_off)}
local network = RGBLED{parent=system,label="NETWORK",colors={colors.green,colors.red,colors.orange,colors.yellow,colors.gray}}
network.update(5)
network.update(types.PANEL_LINK_STATE.DISCONNECTED)
system.line_break()
modem.register(databus.ps, "has_modem", modem.update)
@ -66,6 +67,10 @@ local function init(panel, units)
rt_main.register(databus.ps, "routine__main", rt_main.update)
rt_comm.register(databus.ps, "routine__comms", rt_comm.update)
---@diagnostic disable-next-line: undefined-field
local comp_id = util.sprintf("(%d)", os.getComputerID())
TextBox{parent=system,x=9,y=4,width=6,height=1,text=comp_id,fg_bg=cpair(colors.lightGray,colors.ivory)}
--
-- about label
--

View File

@ -159,12 +159,13 @@ end
---@nodiscard
---@param version string RTU version
---@param modem table modem device
---@param local_port integer local listening port
---@param server_port integer remote server port
---@param rtu_channel integer PLC comms channel
---@param svr_channel integer supervisor server channel
---@param range integer trusted device connection range
---@param conn_watchdog watchdog watchdog reference
function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog)
function rtu.comms(version, modem, rtu_channel, svr_channel, range, conn_watchdog)
local self = {
sv_addr = comms.BROADCAST,
seq_num = 0,
r_seq_num = nil,
txn_id = 0,
@ -180,7 +181,7 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
-- configure modem channels
local function _conf_channels()
modem.closeAll()
modem.open(local_port)
modem.open(rtu_channel)
end
_conf_channels()
@ -193,9 +194,9 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(self.sv_addr, self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
modem.transmit(server_port, local_port, s_pkt.raw_sendable())
modem.transmit(svr_channel, rtu_channel, s_pkt.raw_sendable())
self.seq_num = self.seq_num + 1
end
@ -238,8 +239,8 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
---@param m_pkt modbus_packet
function public.send_modbus(m_pkt)
local s_pkt = comms.scada_packet()
s_pkt.make(self.seq_num, PROTOCOL.MODBUS_TCP, m_pkt.raw_sendable())
modem.transmit(server_port, local_port, s_pkt.raw_sendable())
s_pkt.make(self.sv_addr, self.seq_num, PROTOCOL.MODBUS_TCP, m_pkt.raw_sendable())
modem.transmit(svr_channel, rtu_channel, s_pkt.raw_sendable())
self.seq_num = self.seq_num + 1
end
@ -254,7 +255,9 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
---@param rtu_state rtu_state
function public.unlink(rtu_state)
rtu_state.linked = false
self.sv_addr = comms.BROADCAST
self.r_seq_num = nil
databus.tx_link_state(types.PANEL_LINK_STATE.DISCONNECTED)
end
-- close the connection to the server
@ -327,13 +330,21 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
-- print a log message to the terminal as long as the UI isn't running
local function println_ts(message) if not rtu_state.fp_ok then util.println_ts(message) end end
if packet.scada_frame.local_port() == local_port then
local protocol = packet.scada_frame.protocol()
local l_chan = packet.scada_frame.local_channel()
local src_addr = packet.scada_frame.src_addr()
if l_chan == rtu_channel then
-- check sequence number
if self.r_seq_num == nil then
self.r_seq_num = packet.scada_frame.seq_num()
elseif rtu_state.linked and ((self.r_seq_num + 1) ~= packet.scada_frame.seq_num()) then
log.warning("sequence out-of-order: last = " .. self.r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
return
elseif rtu_state.linked and (src_addr ~= self.sv_addr) then
log.debug("received packet from unknown computer " .. src_addr .. " while linked (expected " .. self.sv_addr ..
"); channel in use by another system?")
return
else
self.r_seq_num = packet.scada_frame.seq_num()
end
@ -341,8 +352,7 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
-- feed watchdog on valid sequence number
conn_watchdog.feed()
local protocol = packet.scada_frame.protocol()
-- handle packet
if protocol == PROTOCOL.MODBUS_TCP then
---@cast packet modbus_frame
if rtu_state.linked then
@ -398,6 +408,7 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
if est_ack == ESTABLISH_ACK.ALLOW then
-- establish allowed
rtu_state.linked = true
self.sv_addr = packet.scada_frame.src_addr()
self.r_seq_num = nil
println_ts("supervisor connection established")
log.info("supervisor connection established")
@ -461,6 +472,8 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
-- should be unreachable assuming packet is from parse_packet()
log.error("illegal packet type " .. protocol, true)
end
else
log.debug("received packet on unconfigured channel " .. l_chan, true)
end
end

View File

@ -28,7 +28,7 @@ local sna_rtu = require("rtu.dev.sna_rtu")
local sps_rtu = require("rtu.dev.sps_rtu")
local turbinev_rtu = require("rtu.dev.turbinev_rtu")
local RTU_VERSION = "v1.2.2"
local RTU_VERSION = "v1.3.5"
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local RTU_UNIT_HW_STATE = databus.RTU_UNIT_HW_STATE
@ -42,8 +42,8 @@ local println_ts = util.println_ts
local cfv = util.new_validator()
cfv.assert_port(config.SERVER_PORT)
cfv.assert_port(config.LISTEN_PORT)
cfv.assert_channel(config.SVR_CHANNEL)
cfv.assert_channel(config.RTU_CHANNEL)
cfv.assert_type_int(config.TRUSTED_RANGE)
cfv.assert_type_num(config.COMMS_TIMEOUT)
cfv.assert_min(config.COMMS_TIMEOUT, 2)
@ -457,9 +457,9 @@ local function main()
if not rtu_state.fp_ok then
renderer.close_ui()
println_ts(util.c("UI error: ", message))
println("init> running without front panel")
println("startup> running without front panel")
log.error(util.c("GUI crashed with error ", message))
log.info("init> running in headless mode without front panel")
log.info("startup> running in headless mode without front panel")
end
-- start connection watchdog
@ -467,7 +467,7 @@ local function main()
log.debug("startup> conn watchdog started")
-- setup comms
smem_sys.rtu_comms = rtu.comms(RTU_VERSION, smem_dev.modem, config.LISTEN_PORT, config.SERVER_PORT,
smem_sys.rtu_comms = rtu.comms(RTU_VERSION, smem_dev.modem, config.RTU_CHANNEL, config.SVR_CHANNEL,
config.TRUSTED_RANGE, smem_sys.conn_watchdog)
log.debug("startup> comms init")

View File

@ -1,6 +1,7 @@
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local types = require("scada-common.types")
local util = require("scada-common.util")
@ -82,6 +83,9 @@ function threads.thread__main(smem)
elseif event == "timer" and conn_watchdog.is_timer(param1) then
-- haven't heard from server recently? unlink
rtu_comms.unlink(rtu_state)
elseif event == "timer" then
-- notify timer callback dispatcher if no other timer case claimed this event
tcd.handle(param1)
elseif event == "peripheral_detach" then
-- handle loss of a device
local type, device = ppm.handle_unmount(param1)

View File

@ -4,14 +4,17 @@
local log = require("scada-common.log")
local insert = table.insert
---@diagnostic disable-next-line: undefined-field
local C_ID = os.getComputerID() ---@type integer computer ID
local max_distance = nil ---@type number|nil maximum acceptable transmission distance
---@class comms
local comms = {}
local insert = table.insert
local max_distance = nil
comms.version = "1.4.1"
comms.version = "2.0.0"
---@enum PROTOCOL
local PROTOCOL = {
@ -122,27 +125,28 @@ comms.PLC_AUTO_ACK = PLC_AUTO_ACK
comms.UNIT_COMMAND = UNIT_COMMAND
comms.FAC_COMMAND = FAC_COMMAND
-- destination broadcast address (to all devices)
comms.BROADCAST = -1
---@alias packet scada_packet|modbus_packet|rplc_packet|mgmt_packet|crdn_packet|capi_packet
---@alias frame modbus_frame|rplc_frame|mgmt_frame|crdn_frame|capi_frame
-- configure the maximum allowable message receive distance<br>
-- packets received with distances greater than this will be silently discarded
---@param distance integer max modem message distance (less than 1 disables the limit)
---@param distance integer max modem message distance (0 disables the limit)
function comms.set_trusted_range(distance)
if distance < 1 then
max_distance = nil
else
max_distance = distance
end
if distance == 0 then max_distance = nil else max_distance = distance end
end
-- generic SCADA packet object
---@nodiscard
function comms.scada_packet()
local self = {
modem_msg_in = nil,
modem_msg_in = nil, ---@type modem_message|nil
valid = false,
raw = { -1, PROTOCOL.SCADA_MGMT, {} },
raw = {},
src_addr = comms.BROADCAST,
dest_addr = comms.BROADCAST,
seq_num = -1,
protocol = PROTOCOL.SCADA_MGMT,
length = 0,
@ -153,34 +157,40 @@ function comms.scada_packet()
local public = {}
-- make a SCADA packet
---@param seq_num integer
---@param dest_addr integer destination computer address (ID)
---@param seq_num integer sequence number
---@param protocol PROTOCOL
---@param payload table
function public.make(seq_num, protocol, payload)
function public.make(dest_addr, seq_num, protocol, payload)
self.valid = true
---@diagnostic disable-next-line: undefined-field
self.src_addr = C_ID
self.dest_addr = dest_addr
self.seq_num = seq_num
self.protocol = protocol
self.length = #payload
self.payload = payload
self.raw = { self.seq_num, self.protocol, self.payload }
self.raw = { self.src_addr, self.dest_addr, self.seq_num, self.protocol, self.payload }
end
-- parse in a modem message as a SCADA packet
---@param side string modem side
---@param sender integer sender port
---@param reply_to integer reply port
---@param sender integer sender channel
---@param reply_to integer reply channel
---@param message any message body
---@param distance integer transmission distance
---@return boolean valid valid message received
function public.receive(side, sender, reply_to, message, distance)
---@class modem_message
self.modem_msg_in = {
iface = side,
s_port = sender,
r_port = reply_to,
s_channel = sender,
r_channel = reply_to,
msg = message,
dist = distance
}
self.valid = false
self.raw = self.modem_msg_in.msg
if (type(max_distance) == "number") and (distance > max_distance) then
@ -188,20 +198,31 @@ function comms.scada_packet()
-- log.debug("comms.scada_packet.receive(): discarding packet with distance " .. distance .. " outside of trusted range")
else
if type(self.raw) == "table" then
if #self.raw >= 3 then
self.seq_num = self.raw[1]
self.protocol = self.raw[2]
if #self.raw == 5 then
self.src_addr = self.raw[1]
self.dest_addr = self.raw[2]
self.seq_num = self.raw[3]
self.protocol = self.raw[4]
-- element 3 must be a table
if type(self.raw[3]) == "table" then
self.length = #self.raw[3]
self.payload = self.raw[3]
-- element 5 must be a table
if type(self.raw[5]) == "table" then
self.length = #self.raw[5]
self.payload = self.raw[5]
end
else
self.src_addr = nil
self.dest_addr = nil
self.seq_num = nil
self.protocol = nil
self.length = 0
self.payload = {}
end
self.valid = type(self.seq_num) == "number" and
type(self.protocol) == "number" and
type(self.payload) == "table"
-- check if this packet is destined for this device
local is_destination = (self.dest_addr == comms.BROADCAST) or (self.dest_addr == C_ID)
self.valid = is_destination and type(self.src_addr) == "number" and type(self.dest_addr) == "number" and
type(self.seq_num) == "number" and type(self.protocol) == "number" and type(self.payload) == "table"
end
end
@ -216,13 +237,17 @@ function comms.scada_packet()
function public.raw_sendable() return self.raw end
---@nodiscard
function public.local_port() return self.modem_msg_in.s_port end
function public.local_channel() return self.modem_msg_in.s_channel end
---@nodiscard
function public.remote_port() return self.modem_msg_in.r_port end
function public.remote_channel() return self.modem_msg_in.r_channel end
---@nodiscard
function public.is_valid() return self.valid end
---@nodiscard
function public.src_addr() return self.src_addr end
---@nodiscard
function public.dest_addr() return self.dest_addr end
---@nodiscard
function public.seq_num() return self.seq_num end
---@nodiscard

View File

@ -5,14 +5,14 @@
local log = require("scada-common.log")
local util = require("scada-common.util")
local tcallbackdsp = {}
local tcd = {}
local registry = {}
-- request a function to be called after the specified time
---@param time number seconds
---@param f function callback function
function tcallbackdsp.dispatch(time, f)
function tcd.dispatch(time, f)
local timer = util.start_timer(time)
registry[timer] = {
callback = f,
@ -24,7 +24,7 @@ end
-- request a function to be called after the specified time, aborting any registered instances of that function reference
---@param time number seconds
---@param f function callback function
function tcallbackdsp.dispatch_unique(time, f)
function tcd.dispatch_unique(time, f)
-- cancel if already registered
for timer, entry in pairs(registry) do
if entry.callback == f then
@ -47,7 +47,7 @@ end
-- abort a requested callback
---@param f function callback function
function tcallbackdsp.abort(f)
function tcd.abort(f)
for timer, entry in pairs(registry) do
if entry.callback == f then
-- cancel event and remove from registry (even if it fires it won't call)
@ -59,7 +59,7 @@ end
-- lookup a timer event and execute the callback if found
---@param event integer timer event timer ID
function tcallbackdsp.handle(event)
function tcd.handle(event)
if registry[event] ~= nil then
local callback = registry[event].callback
-- clear first so that dispatch_unique call from inside callback won't throw a debug message
@ -70,7 +70,7 @@ end
-- identify any overdo callbacks<br>
-- prints to log debug output
function tcallbackdsp.diagnostics()
function tcd.diagnostics()
for timer, entry in pairs(registry) do
if entry.expiry < util.time_s() then
local overtime = util.time_s() - entry.expiry
@ -82,4 +82,4 @@ function tcallbackdsp.diagnostics()
end
end
return tcallbackdsp
return tcd

View File

@ -74,6 +74,15 @@ function types.new_zero_coordinate() return { x = 0, y = 0, z = 0 } end
-- ENUMERATION TYPES --
--#region
---@enum PANEL_LINK_STATE
types.PANEL_LINK_STATE = {
LINKED = 1,
DENIED = 2,
COLLISION = 3,
BAD_VERSION = 4,
DISCONNECTED = 5
}
---@enum RTU_UNIT_TYPE
types.RTU_UNIT_TYPE = {
VIRTUAL = 0, -- virtual device

View File

@ -65,7 +65,8 @@ end
---@return string
function util.strval(val)
local t = type(val)
if t == "table" or t == "function" then
-- this depends on Lua short-circuiting the or check for metatables (note: metatables won't have metatables)
if (t == "table" and (getmetatable(val) == nil or getmetatable(val).__tostring == nil)) or t == "function" then
return "[" .. tostring(val) .. "]"
else
return tostring(val)
@ -539,7 +540,7 @@ function util.new_validator()
function public.assert_range(check, min, max) valid = valid and check >= min and check <= max end
function public.assert_range_ex(check, min, max) valid = valid and check > min and check < max end
function public.assert_port(port) valid = valid and type(port) == "number" and port >= 0 and port <= 65535 end
function public.assert_channel(channel) valid = valid and type(channel) == "number" and channel >= 0 and channel <= 65535 end
-- check if all assertions passed successfully
---@nodiscard

View File

@ -1,9 +1,15 @@
local config = {}
-- scada network listen for PLC's and RTU's
config.SCADA_DEV_LISTEN = 16000
-- listen port for SCADA supervisor access
config.SCADA_SV_CTL_LISTEN = 16100
-- supervisor comms channel
config.SVR_CHANNEL = 16240
-- PLC comms channel
config.PLC_CHANNEL = 16241
-- RTU/MODBUS comms channel
config.RTU_CHANNEL = 16242
-- coordinator comms channel
config.CRD_CHANNEL = 16243
-- pocket comms channel
config.PKT_CHANNEL = 16244
-- max trusted modem message distance (0 to disable check)
config.TRUSTED_RANGE = 0
-- time in seconds (>= 2) before assuming a remote device is no longer active

179
supervisor/databus.lua Normal file
View File

@ -0,0 +1,179 @@
--
-- Data Bus - Central Communication Linking for Supervisor Front Panel
--
local psil = require("scada-common.psil")
local util = require("scada-common.util")
local pgi = require("supervisor.panel.pgi")
-- nominal RTT is ping (0ms to 10ms usually) + 150ms for SV main loop tick
local WARN_RTT = 300 -- 2x as long as expected w/ 0 ping
local HIGH_RTT = 500 -- 3.33x as long as expected w/ 0 ping
local databus = {}
-- databus PSIL
databus.ps = psil.create()
-- call to toggle heartbeat signal
function databus.heartbeat() databus.ps.toggle("heartbeat") end
-- transmit firmware versions across the bus
---@param sv_v string supervisor version
---@param comms_v string comms version
function databus.tx_versions(sv_v, comms_v)
databus.ps.publish("version", sv_v)
databus.ps.publish("comms_version", comms_v)
end
-- transmit hardware status for modem connection state
---@param has_modem boolean
function databus.tx_hw_modem(has_modem)
databus.ps.publish("has_modem", has_modem)
end
-- transmit PLC firmware version and session connection state
---@param reactor_id integer reactor unit ID
---@param fw string firmware version
---@param s_addr integer PLC computer ID
function databus.tx_plc_connected(reactor_id, fw, s_addr)
databus.ps.publish("plc_" .. reactor_id .. "_fw", fw)
databus.ps.publish("plc_" .. reactor_id .. "_conn", true)
databus.ps.publish("plc_" .. reactor_id .. "_addr", util.sprintf("@% 4d", s_addr))
end
-- transmit PLC disconnected
---@param reactor_id integer reactor unit ID
function databus.tx_plc_disconnected(reactor_id)
databus.ps.publish("plc_" .. reactor_id .. "_fw", " ------- ")
databus.ps.publish("plc_" .. reactor_id .. "_conn", false)
databus.ps.publish("plc_" .. reactor_id .. "_addr", " --- ")
databus.ps.publish("plc_" .. reactor_id .. "_rtt", 0)
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.lightGray)
end
-- transmit PLC session RTT
---@param reactor_id integer reactor unit ID
---@param rtt integer round trip time
function databus.tx_plc_rtt(reactor_id, rtt)
databus.ps.publish("plc_" .. reactor_id .. "_rtt", rtt)
if rtt > HIGH_RTT then
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.red)
elseif rtt > WARN_RTT then
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.yellow_hc)
else
databus.ps.publish("plc_" .. reactor_id .. "_rtt_color", colors.green)
end
end
-- transmit RTU firmware version and session connection state
---@param session_id integer RTU session
---@param fw string firmware version
---@param s_addr integer RTU computer ID
function databus.tx_rtu_connected(session_id, fw, s_addr)
databus.ps.publish("rtu_" .. session_id .. "_fw", fw)
databus.ps.publish("rtu_" .. session_id .. "_addr", util.sprintf("@ C% 3d", s_addr))
pgi.create_rtu_entry(session_id)
end
-- transmit RTU disconnected
---@param session_id integer RTU session
function databus.tx_rtu_disconnected(session_id)
pgi.delete_rtu_entry(session_id)
end
-- transmit RTU session RTT
---@param session_id integer RTU session
---@param rtt integer round trip time
function databus.tx_rtu_rtt(session_id, rtt)
databus.ps.publish("rtu_" .. session_id .. "_rtt", rtt)
if rtt > HIGH_RTT then
databus.ps.publish("rtu_" .. session_id .. "_rtt_color", colors.red)
elseif rtt > WARN_RTT then
databus.ps.publish("rtu_" .. session_id .. "_rtt_color", colors.yellow_hc)
else
databus.ps.publish("rtu_" .. session_id .. "_rtt_color", colors.green)
end
end
-- transmit RTU session unit count
---@param session_id integer RTU session
---@param units integer unit count
function databus.tx_rtu_units(session_id, units)
databus.ps.publish("rtu_" .. session_id .. "_units", units)
end
-- transmit coordinator firmware version and session connection state
---@param fw string firmware version
---@param s_addr integer coordinator computer ID
function databus.tx_crd_connected(fw, s_addr)
databus.ps.publish("crd_fw", fw)
databus.ps.publish("crd_conn", true)
databus.ps.publish("crd_addr", tostring(s_addr))
end
-- transmit coordinator disconnected
function databus.tx_crd_disconnected()
databus.ps.publish("crd_fw", " ------- ")
databus.ps.publish("crd_conn", false)
databus.ps.publish("crd_addr", "---")
databus.ps.publish("crd_rtt", 0)
databus.ps.publish("crd_rtt_color", colors.lightGray)
end
-- transmit coordinator session RTT
---@param rtt integer round trip time
function databus.tx_crd_rtt(rtt)
databus.ps.publish("crd_rtt", rtt)
if rtt > HIGH_RTT then
databus.ps.publish("crd_rtt_color", colors.red)
elseif rtt > WARN_RTT then
databus.ps.publish("crd_rtt_color", colors.yellow_hc)
else
databus.ps.publish("crd_rtt_color", colors.green)
end
end
-- transmit PKT firmware version and PDG session connection state
---@param session_id integer PDG session
---@param fw string firmware version
---@param s_addr integer PDG computer ID
function databus.tx_pdg_connected(session_id, fw, s_addr)
databus.ps.publish("pdg_" .. session_id .. "_fw", fw)
databus.ps.publish("pdg_" .. session_id .. "_addr", util.sprintf("@ C% 3d", s_addr))
pgi.create_pdg_entry(session_id)
end
-- transmit PDG session disconnected
---@param session_id integer PDG session
function databus.tx_pdg_disconnected(session_id)
pgi.delete_pdg_entry(session_id)
end
-- transmit PDG session RTT
---@param session_id integer PDG session
---@param rtt integer round trip time
function databus.tx_pdg_rtt(session_id, rtt)
databus.ps.publish("pdg_" .. session_id .. "_rtt", rtt)
if rtt > HIGH_RTT then
databus.ps.publish("pdg_" .. session_id .. "_rtt_color", colors.red)
elseif rtt > WARN_RTT then
databus.ps.publish("pdg_" .. session_id .. "_rtt_color", colors.yellow_hc)
else
databus.ps.publish("pdg_" .. session_id .. "_rtt_color", colors.green)
end
end
-- link a function to receive data from the bus
---@param field string field name
---@param func function function to link
function databus.rx_field(field, func)
databus.ps.subscribe(field, func)
end
return databus

View File

@ -128,7 +128,7 @@ function facility.new(num_reactors, cooling_conf)
for i = 1, #self.prio_defs do
local units = self.prio_defs[i]
for u = 1, #units do
all_ramped = all_ramped and units[u].a_ramp_complete()
all_ramped = all_ramped and units[u].auto_ramp_complete()
end
end
@ -159,7 +159,7 @@ function facility.new(num_reactors, cooling_conf)
local u = units[id] ---@type reactor_unit
local ctl = u.get_control_inf()
local lim_br100 = u.a_get_effective_limit()
local lim_br100 = u.auto_get_effective_limit()
if abort_on_fault and (lim_br100 ~= ctl.lim_br100) then
-- effective limit differs from set limit, unit is degraded
@ -183,7 +183,7 @@ function facility.new(num_reactors, cooling_conf)
unallocated = math.max(0, unallocated - ctl.br100)
if last ~= ctl.br100 then u.a_commit_br100(ramp) end
if last ~= ctl.br100 then u.auto_commit_br100(ramp) end
end
end
end
@ -320,7 +320,7 @@ function facility.new(num_reactors, cooling_conf)
self.start_fail = START_STATUS.BLADE_MISMATCH
end
if self.start_fail == START_STATUS.OK then u.a_engage() end
if self.start_fail == START_STATUS.OK then u.auto_engage() end
self.max_burn_combined = self.max_burn_combined + (u.get_control_inf().lim_br100 / 100.0)
end
@ -340,7 +340,7 @@ function facility.new(num_reactors, cooling_conf)
-- use manual SCRAM since inactive was requested, and automatic SCRAM trips an alarm
for _, u in pairs(self.prio_defs[i]) do
u.scram()
u.a_disengage()
u.auto_disengage()
end
end
@ -601,7 +601,7 @@ function facility.new(num_reactors, cooling_conf)
-- SCRAM all units
for i = 1, #self.prio_defs do
for _, u in pairs(self.prio_defs[i]) do
u.a_scram()
u.auto_scram()
end
end
@ -653,7 +653,7 @@ function facility.new(num_reactors, cooling_conf)
-- reset PLC RPS trips if we should
for i = 1, #self.units do
local u = self.units[i] ---@type reactor_unit
u.a_cond_rps_reset()
u.auto_cond_rps_reset()
end
end
end

View File

@ -0,0 +1,46 @@
--
-- Pocket Diagnostics Connection Entry
--
local databus = require("supervisor.databus")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local TextBox = require("graphics.elements.textbox")
local DataIndicator = require("graphics.elements.indicators.data")
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
-- create a pocket diagnostics list entry
---@param parent graphics_element parent
---@param id integer PDG session ID
local function init(parent, id)
-- root div
local root = Div{parent=parent,x=2,y=2,height=4,width=parent.get_width()-2,hidden=true}
local entry = Div{parent=root,x=2,y=1,height=3,fg_bg=cpair(colors.black,colors.white)}
local ps_prefix = "pdg_" .. id .. "_"
TextBox{parent=entry,x=1,y=1,text="",width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray)}
local pdg_addr = TextBox{parent=entry,x=1,y=2,text="@ C ??",alignment=TEXT_ALIGN.CENTER,width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray),nav_active=cpair(colors.gray,colors.black)}
TextBox{parent=entry,x=1,y=3,text="",width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray)}
pdg_addr.register(databus.ps, ps_prefix .. "addr", pdg_addr.set_value)
TextBox{parent=entry,x=10,y=2,text="FW:",width=3,height=1}
local pdg_fw_v = TextBox{parent=entry,x=14,y=2,text=" ------- ",width=20,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
pdg_fw_v.register(databus.ps, ps_prefix .. "fw", pdg_fw_v.set_value)
TextBox{parent=entry,x=35,y=2,text="RTT:",width=4,height=1}
local pdg_rtt = DataIndicator{parent=entry,x=40,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=cpair(colors.lightGray,colors.white)}
TextBox{parent=entry,x=46,y=2,text="ms",width=4,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
pdg_rtt.register(databus.ps, ps_prefix .. "rtt", pdg_rtt.update)
pdg_rtt.register(databus.ps, ps_prefix .. "rtt_color", pdg_rtt.recolor)
return root
end
return init

View File

@ -0,0 +1,50 @@
--
-- RTU Connection Entry
--
local databus = require("supervisor.databus")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local TextBox = require("graphics.elements.textbox")
local DataIndicator = require("graphics.elements.indicators.data")
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
-- create an RTU list entry
---@param parent graphics_element parent
---@param id integer RTU session ID
local function init(parent, id)
-- root div
local root = Div{parent=parent,x=2,y=2,height=4,width=parent.get_width()-2,hidden=true}
local entry = Div{parent=root,x=2,y=1,height=3,fg_bg=cpair(colors.black,colors.white)}
local ps_prefix = "rtu_" .. id .. "_"
TextBox{parent=entry,x=1,y=1,text="",width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray)}
local rtu_addr = TextBox{parent=entry,x=1,y=2,text="@ C ??",alignment=TEXT_ALIGN.CENTER,width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray),nav_active=cpair(colors.gray,colors.black)}
TextBox{parent=entry,x=1,y=3,text="",width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray)}
rtu_addr.register(databus.ps, ps_prefix .. "addr", rtu_addr.set_value)
TextBox{parent=entry,x=10,y=2,text="UNITS:",width=7,height=1}
local unit_count = DataIndicator{parent=entry,x=17,y=2,label="",unit="",format="%2d",value=0,width=2,fg_bg=cpair(colors.gray,colors.white)}
unit_count.register(databus.ps, ps_prefix .. "units", unit_count.set_value)
TextBox{parent=entry,x=21,y=2,text="FW:",width=3,height=1}
local rtu_fw_v = TextBox{parent=entry,x=25,y=2,text=" ------- ",width=9,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
rtu_fw_v.register(databus.ps, ps_prefix .. "fw", rtu_fw_v.set_value)
TextBox{parent=entry,x=36,y=2,text="RTT:",width=4,height=1}
local rtu_rtt = DataIndicator{parent=entry,x=40,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=cpair(colors.lightGray,colors.white)}
TextBox{parent=entry,x=46,y=2,text="ms",width=4,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
rtu_rtt.register(databus.ps, ps_prefix .. "rtt", rtu_rtt.update)
rtu_rtt.register(databus.ps, ps_prefix .. "rtt_color", rtu_rtt.recolor)
return root
end
return init

View File

@ -0,0 +1,164 @@
--
-- Main SCADA Coordinator GUI
--
local util = require("scada-common.util")
local config = require("supervisor.config")
local databus = require("supervisor.databus")
local pgi = require("supervisor.panel.pgi")
local style = require("supervisor.panel.style")
local pdg_entry = require("supervisor.panel.components.pdg_entry")
local rtu_entry = require("supervisor.panel.components.rtu_entry")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local ListBox = require("graphics.elements.listbox")
local MultiPane = require("graphics.elements.multipane")
local TextBox = require("graphics.elements.textbox")
local TabBar = require("graphics.elements.controls.tabbar")
local LED = require("graphics.elements.indicators.led")
local DataIndicator = require("graphics.elements.indicators.data")
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
-- create new main view
---@param panel graphics_element main displaybox
local function init(panel)
TextBox{parent=panel,y=1,text="SCADA SUPERVISOR",alignment=TEXT_ALIGN.CENTER,height=1,fg_bg=style.header}
local page_div = Div{parent=panel,x=1,y=3}
--
-- system indicators
--
local main_page = Div{parent=page_div,x=1,y=1}
local system = Div{parent=main_page,width=14,height=17,x=2,y=2}
local on = LED{parent=system,label="STATUS",colors=cpair(colors.green,colors.red)}
local heartbeat = LED{parent=system,label="HEARTBEAT",colors=cpair(colors.green,colors.green_off)}
on.update(true)
system.line_break()
heartbeat.register(databus.ps, "heartbeat", heartbeat.update)
local modem = LED{parent=system,label="MODEM",colors=cpair(colors.green,colors.green_off)}
system.line_break()
modem.register(databus.ps, "has_modem", modem.update)
---@diagnostic disable-next-line: undefined-field
local comp_id = util.sprintf("(%d)", os.getComputerID())
TextBox{parent=system,x=9,y=4,width=6,height=1,text=comp_id,fg_bg=cpair(colors.lightGray,colors.ivory)}
--
-- about footer
--
local about = Div{parent=main_page,width=15,height=3,x=1,y=16,fg_bg=cpair(colors.lightGray,colors.ivory)}
local fw_v = TextBox{parent=about,x=1,y=1,text="FW: v00.00.00",alignment=TEXT_ALIGN.LEFT,height=1}
local comms_v = TextBox{parent=about,x=1,y=2,text="NT: v00.00.00",alignment=TEXT_ALIGN.LEFT,height=1}
fw_v.register(databus.ps, "version", function (version) fw_v.set_value(util.c("FW: ", version)) end)
comms_v.register(databus.ps, "comms_version", function (version) comms_v.set_value(util.c("NT: v", version)) end)
--
-- page handling
--
-- plc page
local plc_page = Div{parent=page_div,x=1,y=1,hidden=true}
local plc_list = Div{parent=plc_page,x=2,y=2,width=49}
for i = 1, config.NUM_REACTORS do
local ps_prefix = "plc_" .. i .. "_"
local plc_entry = Div{parent=plc_list,height=3,fg_bg=cpair(colors.black,colors.white)}
TextBox{parent=plc_entry,x=1,y=1,text="",width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray)}
TextBox{parent=plc_entry,x=1,y=2,text="UNIT "..i,alignment=TEXT_ALIGN.CENTER,width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray)}
TextBox{parent=plc_entry,x=1,y=3,text="",width=8,height=1,fg_bg=cpair(colors.black,colors.lightGray)}
local conn = LED{parent=plc_entry,x=10,y=2,label="LINK",colors=cpair(colors.green,colors.green_off)}
conn.register(databus.ps, ps_prefix .. "conn", conn.update)
local plc_addr = TextBox{parent=plc_entry,x=17,y=2,text=" --- ",width=5,height=1,fg_bg=cpair(colors.gray,colors.white)}
plc_addr.register(databus.ps, ps_prefix .. "addr", plc_addr.set_value)
TextBox{parent=plc_entry,x=23,y=2,text="FW:",width=3,height=1}
local plc_fw_v = TextBox{parent=plc_entry,x=27,y=2,text=" ------- ",width=9,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
plc_fw_v.register(databus.ps, ps_prefix .. "fw", plc_fw_v.set_value)
TextBox{parent=plc_entry,x=37,y=2,text="RTT:",width=4,height=1}
local plc_rtt = DataIndicator{parent=plc_entry,x=42,y=2,label="",unit="",format="%4d",value=0,width=4,fg_bg=cpair(colors.lightGray,colors.white)}
TextBox{parent=plc_entry,x=47,y=2,text="ms",width=4,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
plc_rtt.register(databus.ps, ps_prefix .. "rtt", plc_rtt.update)
plc_rtt.register(databus.ps, ps_prefix .. "rtt_color", plc_rtt.recolor)
plc_list.line_break()
end
-- rtu page
local rtu_page = Div{parent=page_div,x=1,y=1,hidden=true}
local rtu_list = ListBox{parent=rtu_page,x=1,y=1,height=17,width=51,scroll_height=1000,fg_bg=cpair(colors.black,colors.ivory),nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)}
local _ = Div{parent=rtu_list,height=1,hidden=true} -- padding
-- coordinator page
local crd_page = Div{parent=page_div,x=1,y=1,hidden=true}
local crd_box = Div{parent=crd_page,x=2,y=2,width=49,height=4,fg_bg=cpair(colors.black,colors.white)}
local crd_conn = LED{parent=crd_box,x=2,y=2,label="CONNECTION",colors=cpair(colors.green,colors.green_off)}
crd_conn.register(databus.ps, "crd_conn", crd_conn.update)
TextBox{parent=crd_box,x=4,y=3,text="COMPUTER",width=8,height=1,fg_bg=cpair(colors.gray,colors.white)}
local crd_addr = TextBox{parent=crd_box,x=13,y=3,text="---",width=5,height=1,fg_bg=cpair(colors.gray,colors.white)}
crd_addr.register(databus.ps, "crd_addr", crd_addr.set_value)
TextBox{parent=crd_box,x=22,y=2,text="FW:",width=3,height=1}
local crd_fw_v = TextBox{parent=crd_box,x=26,y=2,text=" ------- ",width=9,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
crd_fw_v.register(databus.ps, "crd_fw", crd_fw_v.set_value)
TextBox{parent=crd_box,x=36,y=2,text="RTT:",width=4,height=1}
local crd_rtt = DataIndicator{parent=crd_box,x=41,y=2,label="",unit="",format="%5d",value=0,width=5,fg_bg=cpair(colors.lightGray,colors.white)}
TextBox{parent=crd_box,x=47,y=2,text="ms",width=4,height=1,fg_bg=cpair(colors.lightGray,colors.white)}
crd_rtt.register(databus.ps, "crd_rtt", crd_rtt.update)
crd_rtt.register(databus.ps, "crd_rtt_color", crd_rtt.recolor)
-- pocket diagnostics page
local pkt_page = Div{parent=page_div,x=1,y=1,hidden=true}
local pdg_list = ListBox{parent=pkt_page,x=1,y=1,height=17,width=51,scroll_height=1000,fg_bg=cpair(colors.black,colors.ivory),nav_fg_bg=cpair(colors.gray,colors.lightGray),nav_active=cpair(colors.black,colors.gray)}
local _ = Div{parent=pdg_list,height=1,hidden=true} -- padding
-- assemble page panes
local panes = { main_page, plc_page, rtu_page, crd_page, pkt_page }
local page_pane = MultiPane{parent=page_div,x=1,y=1,panes=panes}
local tabs = {
{ name = "SVR", color = cpair(colors.black, colors.ivory) },
{ name = "PLC", color = cpair(colors.black, colors.ivory) },
{ name = "RTU", color = cpair(colors.black, colors.ivory) },
{ name = "CRD", color = cpair(colors.black, colors.ivory) },
{ name = "PKT", color = cpair(colors.black, colors.ivory) },
}
TabBar{parent=panel,y=2,tabs=tabs,min_width=9,callback=page_pane.set_value,fg_bg=cpair(colors.black,colors.white)}
-- link RTU/PDG list management to PGI
pgi.link_elements(rtu_list, rtu_entry, pdg_list, pdg_entry)
end
return init

93
supervisor/panel/pgi.lua Normal file
View File

@ -0,0 +1,93 @@
--
-- Protected Graphics Interface
--
local log = require("scada-common.log")
local util = require("scada-common.util")
local pgi = {}
local data = {
rtu_list = nil, ---@type nil|graphics_element
pdg_list = nil, ---@type nil|graphics_element
rtu_entry = nil, ---@type function
pdg_entry = nil, ---@type function
-- session entries
s_entries = { rtu = {}, pdg = {} }
}
-- link list boxes
---@param rtu_list graphics_element RTU list element
---@param rtu_entry function RTU entry constructor
---@param pdg_list graphics_element pocket diagnostics list element
---@param pdg_entry function pocket diagnostics entry constructor
function pgi.link_elements(rtu_list, rtu_entry, pdg_list, pdg_entry)
data.rtu_list = rtu_list
data.pdg_list = pdg_list
data.rtu_entry = rtu_entry
data.pdg_entry = pdg_entry
end
-- unlink all fields, disabling the PGI
function pgi.unlink()
data.rtu_list = nil
data.pdg_list = nil
data.rtu_entry = nil
data.pdg_entry = nil
end
-- add an RTU entry to the RTU list
---@param session_id integer RTU session
function pgi.create_rtu_entry(session_id)
if data.rtu_list ~= nil and data.rtu_entry ~= nil then
local success, result = pcall(data.rtu_entry, data.rtu_list, session_id)
if success then
data.s_entries.rtu[session_id] = result
else
log.error(util.c("PGI: failed to create RTU entry (", result, ")"), true)
end
end
end
-- delete an RTU entry from the RTU list
---@param session_id integer RTU session
function pgi.delete_rtu_entry(session_id)
if data.s_entries.rtu[session_id] ~= nil then
local success, result = pcall(data.s_entries.rtu[session_id].delete)
data.s_entries.rtu[session_id] = nil
if not success then
log.error(util.c("PGI: failed to delete RTU entry (", result, ")"), true)
end
end
end
-- add a PDG entry to the PDG list
---@param session_id integer pocket diagnostics session
function pgi.create_pdg_entry(session_id)
if data.pdg_list ~= nil and data.pdg_entry ~= nil then
local success, result = pcall(data.pdg_entry, data.pdg_list, session_id)
if success then
data.s_entries.pdg[session_id] = result
else
log.error(util.c("PGI: failed to create PDG entry (", result, ")"), true)
end
end
end
-- delete a PDG entry from the PDG list
---@param session_id integer pocket diagnostics session
function pgi.delete_pdg_entry(session_id)
if data.s_entries.pdg[session_id] ~= nil then
local success, result = pcall(data.s_entries.pdg[session_id].delete)
data.s_entries.pdg[session_id] = nil
if not success then
log.error(util.c("PGI: failed to delete PDG entry (", result, ")"), true)
end
end
end
return pgi

View File

@ -0,0 +1,42 @@
--
-- Graphics Style Options
--
local core = require("graphics.core")
local style = {}
local cpair = core.cpair
-- GLOBAL --
-- remap global colors
colors.ivory = colors.pink
colors.yellow_hc = colors.purple
colors.red_off = colors.brown
colors.yellow_off = colors.magenta
colors.green_off = colors.lime
style.root = cpair(colors.black, colors.ivory)
style.header = cpair(colors.black, colors.lightGray)
style.colors = {
{ c = colors.red, hex = 0xdf4949 }, -- RED ON
{ c = colors.orange, hex = 0xffb659 },
{ c = colors.yellow, hex = 0xf9fb53 }, -- YELLOW ON
{ c = colors.lime, hex = 0x16665a }, -- GREEN OFF
{ c = colors.green, hex = 0x6be551 }, -- GREEN ON
{ c = colors.cyan, hex = 0x34bac8 },
{ c = colors.lightBlue, hex = 0x6cc0f2 },
{ c = colors.blue, hex = 0x0008fe }, -- LCD BLUE
{ c = colors.purple, hex = 0xe3bc2a }, -- YELLOW HIGH CONTRAST
{ c = colors.pink, hex = 0xdcd9ca }, -- IVORY
{ c = colors.magenta, hex = 0x85862c }, -- YELLOW OFF
-- { c = colors.white, hex = 0xdcd9ca },
{ c = colors.lightGray, hex = 0xb1b8b3 },
{ c = colors.gray, hex = 0x575757 },
-- { c = colors.black, hex = 0x191919 },
{ c = colors.brown, hex = 0x672223 } -- RED OFF
}
return style

84
supervisor/renderer.lua Normal file
View File

@ -0,0 +1,84 @@
--
-- Graphics Rendering Control
--
local panel_view = require("supervisor.panel.front_panel")
local pgi = require("supervisor.panel.pgi")
local style = require("supervisor.panel.style")
local flasher = require("graphics.flasher")
local DisplayBox = require("graphics.elements.displaybox")
local renderer = {}
local ui = {
display = nil
}
-- start the UI
function renderer.start_ui()
if ui.display == nil then
-- reset terminal
term.setTextColor(colors.white)
term.setBackgroundColor(colors.black)
term.clear()
term.setCursorPos(1, 1)
-- set overridden colors
for i = 1, #style.colors do
term.setPaletteColor(style.colors[i].c, style.colors[i].hex)
end
-- init front panel view
ui.display = DisplayBox{window=term.current(),fg_bg=style.root}
panel_view(ui.display)
-- start flasher callback task
flasher.run()
end
end
-- close out the UI
function renderer.close_ui()
if ui.display ~= nil then
-- stop blinking indicators
flasher.clear()
-- disable PGI
pgi.unlink()
-- hide to stop animation callbacks
ui.display.hide()
-- clear root UI elements
ui.display = nil
-- restore colors
for i = 1, #style.colors do
local r, g, b = term.nativePaletteColor(style.colors[i].c)
term.setPaletteColor(style.colors[i].c, r, g, b)
end
-- reset terminal
term.setTextColor(colors.white)
term.setBackgroundColor(colors.black)
term.clear()
term.setCursorPos(1, 1)
end
end
-- is the UI ready?
---@nodiscard
---@return boolean ready
function renderer.ui_ready() return ui.display ~= nil end
-- handle a mouse event
---@param event mouse_interaction|nil
function renderer.handle_mouse(event)
if ui.display ~= nil and event ~= nil then
ui.display.handle_mouse(event)
end
end
return renderer

View File

@ -4,6 +4,8 @@ local mqueue = require("scada-common.mqueue")
local types = require("scada-common.types")
local util = require("scada-common.util")
local databus = require("supervisor.databus")
local svqtypes = require("supervisor.session.svqtypes")
local coordinator = {}
@ -18,8 +20,6 @@ local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local SV_Q_DATA = svqtypes.SV_Q_DATA
local println = util.println
-- retry time constants in ms
-- local INITIAL_WAIT = 1500
local RETRY_PERIOD = 1000
@ -45,11 +45,16 @@ local PERIODICS = {
-- coordinator supervisor session
---@nodiscard
---@param id integer session ID
---@param s_addr integer device source address
---@param in_queue mqueue in message queue
---@param out_queue mqueue out message queue
---@param timeout number communications timeout
---@param facility facility facility data table
function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
---@param fp_ok boolean if the front panel UI is running
function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facility, fp_ok)
-- print a log message to the terminal as long as the UI isn't running
local function println(message) if not fp_ok then util.println_ts(message) end end
local log_header = "crdn_session(" .. id .. "): "
local self = {
@ -84,6 +89,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
local function _close()
self.conn_watchdog.cancel()
self.connected = false
databus.tx_crd_disconnected()
end
-- send a CRDN packet
@ -94,7 +100,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
local c_pkt = comms.crdn_packet()
c_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.SCADA_CRDN, c_pkt.raw_sendable())
s_pkt.make(s_addr, self.seq_num, PROTOCOL.SCADA_CRDN, c_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -108,7 +114,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(s_addr, self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -205,6 +211,8 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
-- log.debug(log_header .. "COORD RTT = " .. self.last_rtt .. "ms")
-- log.debug(log_header .. "COORD TT = " .. (srv_now - coord_send) .. "ms")
databus.tx_crd_rtt(self.last_rtt)
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end
@ -327,7 +335,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
end
end
---@class coord_session
---@class crd_session
local public = {}
-- get the session ID

View File

@ -4,6 +4,8 @@ local mqueue = require("scada-common.mqueue")
local types = require("scada-common.types")
local util = require("scada-common.util")
local databus = require("supervisor.databus")
local svqtypes = require("supervisor.session.svqtypes")
local plc = {}
@ -14,8 +16,6 @@ local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local PLC_AUTO_ACK = comms.PLC_AUTO_ACK
local UNIT_COMMAND = comms.UNIT_COMMAND
local println = util.println
-- retry time constants in ms
local INITIAL_WAIT = 1500
local INITIAL_AUTO_WAIT = 1000
@ -45,11 +45,16 @@ local PERIODICS = {
-- PLC supervisor session
---@nodiscard
---@param id integer session ID
---@param s_addr integer device source address
---@param reactor_id integer reactor ID
---@param in_queue mqueue in message queue
---@param out_queue mqueue out message queue
---@param timeout number communications timeout
function plc.new_session(id, reactor_id, in_queue, out_queue, timeout)
---@param fp_ok boolean if the front panel UI is running
function plc.new_session(id, s_addr, reactor_id, in_queue, out_queue, timeout, fp_ok)
-- print a log message to the terminal as long as the UI isn't running
local function println(message) if not fp_ok then util.println_ts(message) end end
local log_header = "plc_session(" .. id .. "): "
local self = {
@ -235,6 +240,7 @@ function plc.new_session(id, reactor_id, in_queue, out_queue, timeout)
local function _close()
self.conn_watchdog.cancel()
self.connected = false
databus.tx_plc_disconnected(reactor_id)
end
-- send an RPLC packet
@ -245,7 +251,7 @@ function plc.new_session(id, reactor_id, in_queue, out_queue, timeout)
local r_pkt = comms.rplc_packet()
r_pkt.make(reactor_id, msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.RPLC, r_pkt.raw_sendable())
s_pkt.make(s_addr, self.seq_num, PROTOCOL.RPLC, r_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -259,7 +265,7 @@ function plc.new_session(id, reactor_id, in_queue, out_queue, timeout)
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(s_addr, self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -485,6 +491,8 @@ function plc.new_session(id, reactor_id, in_queue, out_queue, timeout)
-- log.debug(log_header .. "PLC RTT = " .. self.last_rtt .. "ms")
-- log.debug(log_header .. "PLC TT = " .. (srv_now - plc_send) .. "ms")
databus.tx_plc_rtt(reactor_id, self.last_rtt)
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end

View File

@ -1,15 +1,14 @@
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local util = require("scada-common.util")
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local util = require("scada-common.util")
local databus = require("supervisor.databus")
local pocket = {}
local PROTOCOL = comms.PROTOCOL
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local println = util.println
-- retry time constants in ms
-- local INITIAL_WAIT = 1500
-- local RETRY_PERIOD = 1000
@ -30,11 +29,16 @@ local PERIODICS = {
-- pocket diagnostics session
---@nodiscard
---@param id integer session ID
---@param s_addr integer device source address
---@param in_queue mqueue in message queue
---@param out_queue mqueue out message queue
---@param timeout number communications timeout
function pocket.new_session(id, in_queue, out_queue, timeout)
local log_header = "diag_session(" .. id .. "): "
---@param fp_ok boolean if the front panel UI is running
function pocket.new_session(id, s_addr, in_queue, out_queue, timeout, fp_ok)
-- print a log message to the terminal as long as the UI isn't running
local function println(message) if not fp_ok then util.println_ts(message) end end
local log_header = "pdg_session(" .. id .. "): "
local self = {
-- connection properties
@ -55,18 +59,19 @@ function pocket.new_session(id, in_queue, out_queue, timeout)
acks = {
},
-- session database
---@class diag_db
---@class pdg_db
sDB = {
}
}
---@class diag_session
---@class pdg_session
local public = {}
-- mark this diagnostics session as closed, stop watchdog
local function _close()
self.conn_watchdog.cancel()
self.connected = false
databus.tx_pdg_disconnected(id)
end
-- send a SCADA management packet
@ -77,7 +82,7 @@ function pocket.new_session(id, in_queue, out_queue, timeout)
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(s_addr, self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -106,16 +111,18 @@ function pocket.new_session(id, in_queue, out_queue, timeout)
-- keep alive reply
if pkt.length == 2 then
local srv_start = pkt.data[1]
-- local diag_send = pkt.data[2]
-- local pdg_send = pkt.data[2]
local srv_now = util.time()
self.last_rtt = srv_now - srv_start
if self.last_rtt > 750 then
log.warning(log_header .. "DIAG KEEP_ALIVE round trip time > 750ms (" .. self.last_rtt .. "ms)")
log.warning(log_header .. "PDG KEEP_ALIVE round trip time > 750ms (" .. self.last_rtt .. "ms)")
end
-- log.debug(log_header .. "DIAG RTT = " .. self.last_rtt .. "ms")
-- log.debug(log_header .. "DIAG TT = " .. (srv_now - diag_send) .. "ms")
-- log.debug(log_header .. "PDG RTT = " .. self.last_rtt .. "ms")
-- log.debug(log_header .. "PDG TT = " .. (srv_now - pdg_send) .. "ms")
databus.tx_pdg_rtt(id, self.last_rtt)
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end

View File

@ -4,6 +4,8 @@ local mqueue = require("scada-common.mqueue")
local types = require("scada-common.types")
local util = require("scada-common.util")
local databus = require("supervisor.databus")
local svqtypes = require("supervisor.session.svqtypes")
-- supervisor rtu sessions (svrs)
@ -22,8 +24,6 @@ local PROTOCOL = comms.PROTOCOL
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local println = util.println
local PERIODICS = {
KEEP_ALIVE = 2000
}
@ -31,12 +31,17 @@ local PERIODICS = {
-- create a new RTU session
---@nodiscard
---@param id integer session ID
---@param s_addr integer device source address
---@param in_queue mqueue in message queue
---@param out_queue mqueue out message queue
---@param timeout number communications timeout
---@param advertisement table RTU device advertisement
---@param facility facility facility data table
function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facility)
---@param fp_ok boolean if the front panel UI is running
function rtu.new_session(id, s_addr, in_queue, out_queue, timeout, advertisement, facility, fp_ok)
-- print a log message to the terminal as long as the UI isn't running
local function println(message) if not fp_ok then util.println_ts(message) end end
local log_header = "rtu_session(" .. id .. "): "
local self = {
@ -66,6 +71,8 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
-- parse the recorded advertisement and create unit sub-sessions
local function _handle_advertisement()
local unit_count = 0
_reset_config()
for i = 1, #self.fac_units do
@ -172,18 +179,22 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
if unit ~= nil then
self.units[i] = unit
unit_count = unit_count + 1
elseif u_type ~= RTU_UNIT_TYPE.VIRTUAL then
_reset_config()
log.error(util.c(log_header, "bad advertisement: error occured while creating a unit (type is ", type_string, ")"))
break
end
end
databus.tx_rtu_units(id, unit_count)
end
-- mark this RTU session as closed, stop watchdog
local function _close()
self.conn_watchdog.cancel()
self.connected = false
databus.tx_rtu_disconnected(id)
-- mark all RTU unit sessions as closed so the reactor unit knows
for _, unit in pairs(self.units) do unit.close() end
@ -194,7 +205,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
local function _send_modbus(m_pkt)
local s_pkt = comms.scada_packet()
s_pkt.make(self.seq_num, PROTOCOL.MODBUS_TCP, m_pkt.raw_sendable())
s_pkt.make(s_addr, self.seq_num, PROTOCOL.MODBUS_TCP, m_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -208,7 +219,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(s_addr, self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
out_queue.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -254,6 +265,8 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
-- log.debug(log_header .. "RTU RTT = " .. self.last_rtt .. "ms")
-- log.debug(log_header .. "RTU TT = " .. (srv_now - rtu_send) .. "ms")
databus.tx_rtu_rtt(id, self.last_rtt)
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end

View File

@ -3,6 +3,7 @@ local mqueue = require("scada-common.mqueue")
local util = require("scada-common.util")
local config = require("supervisor.config")
local databus = require("supervisor.databus")
local facility = require("supervisor.facility")
local svqtypes = require("supervisor.session.svqtypes")
@ -22,24 +23,26 @@ local CRD_S_DATA = coordinator.CRD_S_DATA
local svsessions = {}
---@enum SESSION_TYPE
local SESSION_TYPE = {
RTU_SESSION = 0, -- RTU gateway
PLC_SESSION = 1, -- reactor PLC
COORD_SESSION = 2, -- coordinator
DIAG_SESSION = 3 -- pocket diagnostics
CRD_SESSION = 2, -- coordinator
PDG_SESSION = 3 -- pocket diagnostics
}
svsessions.SESSION_TYPE = SESSION_TYPE
local self = {
modem = nil, ---@type table|nil
fp_ok = false,
num_reactors = 0,
facility = nil, ---@type facility|nil
sessions = { rtu = {}, plc = {}, coord = {}, diag = {} },
next_ids = { rtu = 0, plc = 0, coord = 0, diag = 0 }
sessions = { rtu = {}, plc = {}, crd = {}, pdg = {} },
next_ids = { rtu = 0, plc = 0, crd = 0, pdg = 0 }
}
---@alias sv_session_structs plc_session_struct|rtu_session_struct|coord_session_struct|diag_session_struct
---@alias sv_session_structs plc_session_struct|rtu_session_struct|crd_session_struct|pdg_session_struct
-- PRIVATE FUNCTIONS --
@ -57,7 +60,7 @@ local function _sv_handle_outq(session)
if msg ~= nil then
if msg.qtype == mqueue.TYPE.PACKET then
-- handle a packet to be sent
self.modem.transmit(session.r_port, session.l_port, msg.message.raw_sendable())
self.modem.transmit(session.r_chan, config.SVR_CHANNEL, msg.message.raw_sendable())
elseif msg.qtype == mqueue.TYPE.COMMAND then
-- handle instruction/notification
elseif msg.qtype == mqueue.TYPE.DATA then
@ -78,11 +81,11 @@ local function _sv_handle_outq(session)
elseif cmd.key == SV_Q_DATA.SET_BURN and type(cmd.val) == "table" and #cmd.val == 2 then
plc_s.in_queue.push_data(PLC_S_DATA.BURN_RATE, cmd.val[2])
else
log.debug(util.c("unknown PLC SV queue command ", cmd.key))
log.debug(util.c("[SVS] unknown PLC SV queue command ", cmd.key))
end
end
else
local crd_s = svsessions.get_coord_session()
local crd_s = svsessions.get_crd_session()
if crd_s ~= nil then
if cmd.key == SV_Q_DATA.CRDN_ACK then
-- ack to be sent to coordinator
@ -101,8 +104,8 @@ local function _sv_handle_outq(session)
-- max 100ms spent processing queue
if util.time() - handle_start > 100 then
log.warning("supervisor out queue handler exceeded 100ms queue process limit")
log.warning(util.c("offending session: port ", session.r_port, " type '", session.s_type, "'"))
log.warning("[SVS] supervisor out queue handler exceeded 100ms queue process limit")
log.warning(util.c("[SVS] offending session: ", session))
break
end
end
@ -128,15 +131,15 @@ local function _shutdown(session)
session.open = false
session.instance.close()
-- send packets in out queue (namely the close packet)
-- send packets in out queue (for the close packet)
while session.out_queue.ready() do
local msg = session.out_queue.pop()
if msg ~= nil and msg.qtype == mqueue.TYPE.PACKET then
self.modem.transmit(session.r_port, session.l_port, msg.message.raw_sendable())
self.modem.transmit(session.r_chan, config.SVR_CHANNEL, msg.message.raw_sendable())
end
end
log.debug(util.c("closed ", session.s_type, " session ", session.instance.get_id(), " on remote port ", session.r_port))
log.debug(util.c("[SVS] closed session ", session))
end
-- close connections
@ -157,8 +160,7 @@ local function _check_watchdogs(sessions, timer_event)
if session.open then
local triggered = session.instance.check_wd(timer_event)
if triggered then
log.debug(util.c("watchdog closing ", session.s_type, " session ", session.instance.get_id(),
" on remote port ", session.r_port, "..."))
log.debug(util.c("[SVS] watchdog closing session ", session, "..."))
_shutdown(session)
end
end
@ -172,21 +174,20 @@ local function _free_closed(sessions)
---@param session sv_session_structs
local on_delete = function (session)
log.debug(util.c("free'ing closed ", session.s_type, " session ", session.instance.get_id(),
" on remote port ", session.r_port))
log.debug(util.c("[SVS] free'ing closed session ", session))
end
util.filter_table(sessions, f, on_delete)
end
-- find a session by remote port
-- find a session by computer ID
---@nodiscard
---@param list table
---@param port integer
---@param s_addr integer
---@return sv_session_structs|nil
local function _find_session(list, port)
local function _find_session(list, s_addr)
for i = 1, #list do
if list[i].r_port == port then return list[i] end
if list[i].s_addr == s_addr then return list[i] end
end
return nil
end
@ -194,11 +195,13 @@ end
-- PUBLIC FUNCTIONS --
-- initialize svsessions
---@param modem table
---@param num_reactors integer
---@param cooling_conf table
function svsessions.init(modem, num_reactors, cooling_conf)
---@param modem table modem device
---@param fp_ok boolean front panel active
---@param num_reactors integer number of reactors
---@param cooling_conf table cooling configuration definition
function svsessions.init(modem, fp_ok, num_reactors, cooling_conf)
self.modem = modem
self.fp_ok = fp_ok
self.num_reactors = num_reactors
self.facility = facility.new(num_reactors, cooling_conf)
end
@ -209,63 +212,55 @@ function svsessions.relink_modem(modem)
self.modem = modem
end
-- find an RTU session by the remote port
-- find an RTU session by the computer ID
---@nodiscard
---@param remote_port integer
---@param source_addr integer
---@return rtu_session_struct|nil
function svsessions.find_rtu_session(remote_port)
function svsessions.find_rtu_session(source_addr)
-- check RTU sessions
local session = _find_session(self.sessions.rtu, remote_port)
local session = _find_session(self.sessions.rtu, source_addr)
---@cast session rtu_session_struct|nil
return session
end
-- find a PLC session by the remote port
-- find a PLC session by the computer ID
---@nodiscard
---@param remote_port integer
---@param source_addr integer
---@return plc_session_struct|nil
function svsessions.find_plc_session(remote_port)
function svsessions.find_plc_session(source_addr)
-- check PLC sessions
local session = _find_session(self.sessions.plc, remote_port)
local session = _find_session(self.sessions.plc, source_addr)
---@cast session plc_session_struct|nil
return session
end
-- find a PLC/RTU session by the remote port
-- find a coordinator session by the computer ID
---@nodiscard
---@param remote_port integer
---@return plc_session_struct|rtu_session_struct|nil
function svsessions.find_device_session(remote_port)
-- check RTU sessions
local session = _find_session(self.sessions.rtu, remote_port)
-- check PLC sessions
if session == nil then session = _find_session(self.sessions.plc, remote_port) end
---@cast session plc_session_struct|rtu_session_struct|nil
---@param source_addr integer
---@return crd_session_struct|nil
function svsessions.find_crd_session(source_addr)
-- check coordinator sessions
local session = _find_session(self.sessions.crd, source_addr)
---@cast session crd_session_struct|nil
return session
end
-- find a coordinator or diagnostic access session by the remote port
-- find a pocket diagnostics session by the computer ID
---@nodiscard
---@param remote_port integer
---@return coord_session_struct|diag_session_struct|nil
function svsessions.find_svctl_session(remote_port)
-- check coordinator sessions
local session = _find_session(self.sessions.coord, remote_port)
---@param source_addr integer
---@return pdg_session_struct|nil
function svsessions.find_pdg_session(source_addr)
-- check diagnostic sessions
if session == nil then session = _find_session(self.sessions.diag, remote_port) end
---@cast session coord_session_struct|diag_session_struct|nil
local session = _find_session(self.sessions.pdg, source_addr)
---@cast session pdg_session_struct|nil
return session
end
-- get the a coordinator session if exists
---@nodiscard
---@return coord_session_struct|nil
function svsessions.get_coord_session()
return self.sessions.coord[1]
---@return crd_session_struct|nil
function svsessions.get_crd_session()
return self.sessions.crd[1]
end
-- get a session by reactor ID
@ -286,12 +281,11 @@ end
-- establish a new PLC session
---@nodiscard
---@param local_port integer
---@param remote_port integer
---@param source_addr integer
---@param for_reactor integer
---@param version string
---@return integer|false session_id
function svsessions.establish_plc_session(local_port, remote_port, for_reactor, version)
function svsessions.establish_plc_session(source_addr, for_reactor, version)
if svsessions.get_reactor_session(for_reactor) == nil and for_reactor >= 1 and for_reactor <= self.num_reactors then
---@class plc_session_struct
local plc_s = {
@ -299,22 +293,34 @@ function svsessions.establish_plc_session(local_port, remote_port, for_reactor,
open = true,
reactor = for_reactor,
version = version,
l_port = local_port,
r_port = remote_port,
r_chan = config.PLC_CHANNEL,
s_addr = source_addr,
in_queue = mqueue.new(),
out_queue = mqueue.new(),
instance = nil ---@type plc_session
}
plc_s.instance = plc.new_session(self.next_ids.plc, for_reactor, plc_s.in_queue, plc_s.out_queue, config.PLC_TIMEOUT)
local id = self.next_ids.plc
plc_s.instance = plc.new_session(id, source_addr, for_reactor, plc_s.in_queue, plc_s.out_queue,
config.PLC_TIMEOUT, self.fp_ok)
table.insert(self.sessions.plc, plc_s)
local units = self.facility.get_units()
units[for_reactor].link_plc_session(plc_s)
log.debug(util.c("established new PLC session to ", remote_port, " with ID ", self.next_ids.plc, " for reactor ", for_reactor))
local mt = {
---@param s plc_session_struct
__tostring = function (s) return util.c("PLC [", s.instance.get_id(), "] for reactor #", s.reactor,
" (@", s.s_addr, ")") end
}
self.next_ids.plc = self.next_ids.plc + 1
setmetatable(plc_s, mt)
databus.tx_plc_connected(for_reactor, version, source_addr)
log.debug(util.c("[SVS] established new session: ", plc_s))
self.next_ids.plc = id + 1
-- success
return plc_s.instance.get_id()
@ -326,64 +332,84 @@ end
-- establish a new RTU session
---@nodiscard
---@param local_port integer
---@param remote_port integer
---@param source_addr integer
---@param advertisement table
---@param version string
---@return integer session_id
function svsessions.establish_rtu_session(local_port, remote_port, advertisement, version)
function svsessions.establish_rtu_session(source_addr, advertisement, version)
---@class rtu_session_struct
local rtu_s = {
s_type = "rtu",
open = true,
version = version,
l_port = local_port,
r_port = remote_port,
r_chan = config.RTU_CHANNEL,
s_addr = source_addr,
in_queue = mqueue.new(),
out_queue = mqueue.new(),
instance = nil ---@type rtu_session
}
rtu_s.instance = rtu.new_session(self.next_ids.rtu, rtu_s.in_queue, rtu_s.out_queue, config.RTU_TIMEOUT, advertisement, self.facility)
local id = self.next_ids.rtu
rtu_s.instance = rtu.new_session(id, source_addr, rtu_s.in_queue, rtu_s.out_queue, config.RTU_TIMEOUT,
advertisement, self.facility, self.fp_ok)
table.insert(self.sessions.rtu, rtu_s)
log.debug("established new RTU session to " .. remote_port .. " with ID " .. self.next_ids.rtu)
local mt = {
---@param s rtu_session_struct
__tostring = function (s) return util.c("RTU [", s.instance.get_id(), "] (@", s.s_addr, ")") end
}
self.next_ids.rtu = self.next_ids.rtu + 1
setmetatable(rtu_s, mt)
databus.tx_rtu_connected(id, version, source_addr)
log.debug(util.c("[SVS] established new session: ", rtu_s))
self.next_ids.rtu = id + 1
-- success
return rtu_s.instance.get_id()
return id
end
-- establish a new coordinator session
---@nodiscard
---@param local_port integer
---@param remote_port integer
---@param source_addr integer
---@param version string
---@return integer|false session_id
function svsessions.establish_coord_session(local_port, remote_port, version)
if svsessions.get_coord_session() == nil then
---@class coord_session_struct
local coord_s = {
function svsessions.establish_crd_session(source_addr, version)
if svsessions.get_crd_session() == nil then
---@class crd_session_struct
local crd_s = {
s_type = "crd",
open = true,
version = version,
l_port = local_port,
r_port = remote_port,
r_chan = config.CRD_CHANNEL,
s_addr = source_addr,
in_queue = mqueue.new(),
out_queue = mqueue.new(),
instance = nil ---@type coord_session
instance = nil ---@type crd_session
}
coord_s.instance = coordinator.new_session(self.next_ids.coord, coord_s.in_queue, coord_s.out_queue, config.CRD_TIMEOUT, self.facility)
table.insert(self.sessions.coord, coord_s)
local id = self.next_ids.crd
log.debug("established new coordinator session to " .. remote_port .. " with ID " .. self.next_ids.coord)
crd_s.instance = coordinator.new_session(id, source_addr, crd_s.in_queue, crd_s.out_queue, config.CRD_TIMEOUT,
self.facility, self.fp_ok)
table.insert(self.sessions.crd, crd_s)
self.next_ids.coord = self.next_ids.coord + 1
local mt = {
---@param s crd_session_struct
__tostring = function (s) return util.c("CRD [", s.instance.get_id(), "] (@", s.s_addr, ")") end
}
setmetatable(crd_s, mt)
databus.tx_crd_connected(version, source_addr)
log.debug(util.c("[SVS] established new session: ", crd_s))
self.next_ids.crd = id + 1
-- success
return coord_s.instance.get_id()
return id
else
-- we already have a coordinator linked
return false
@ -392,32 +418,41 @@ end
-- establish a new pocket diagnostics session
---@nodiscard
---@param local_port integer
---@param remote_port integer
---@param source_addr integer
---@param version string
---@return integer|false session_id
function svsessions.establish_diag_session(local_port, remote_port, version)
---@class diag_session_struct
local diag_s = {
function svsessions.establish_pdg_session(source_addr, version)
---@class pdg_session_struct
local pdg_s = {
s_type = "pkt",
open = true,
version = version,
l_port = local_port,
r_port = remote_port,
r_chan = config.PKT_CHANNEL,
s_addr = source_addr,
in_queue = mqueue.new(),
out_queue = mqueue.new(),
instance = nil ---@type diag_session
instance = nil ---@type pdg_session
}
diag_s.instance = pocket.new_session(self.next_ids.diag, diag_s.in_queue, diag_s.out_queue, config.PKT_TIMEOUT)
table.insert(self.sessions.diag, diag_s)
local id = self.next_ids.pdg
log.debug("established new pocket diagnostics session to " .. remote_port .. " with ID " .. self.next_ids.diag)
pdg_s.instance = pocket.new_session(id, source_addr, pdg_s.in_queue, pdg_s.out_queue, config.PKT_TIMEOUT, self.fp_ok)
table.insert(self.sessions.pdg, pdg_s)
self.next_ids.diag = self.next_ids.diag + 1
local mt = {
---@param s pdg_session_struct
__tostring = function (s) return util.c("PDG [", s.instance.get_id(), "] (@", s.s_addr, ")") end
}
setmetatable(pdg_s, mt)
databus.tx_pdg_connected(id, version, source_addr)
log.debug(util.c("[SVS] established new session: ", pdg_s))
self.next_ids.pdg = id + 1
-- success
return diag_s.instance.get_id()
return id
end
-- attempt to identify which session's watchdog timer fired
@ -449,9 +484,7 @@ end
-- close all open connections
function svsessions.close_all()
-- close sessions
for _, list in pairs(self.sessions) do
_close(list)
end
for _, list in pairs(self.sessions) do _close(list) end
-- free sessions
svsessions.free_all_closed()

View File

@ -5,16 +5,22 @@
require("/initenv").init_env()
local crash = require("scada-common.crash")
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local core = require("graphics.core")
local config = require("supervisor.config")
local databus = require("supervisor.databus")
local renderer = require("supervisor.renderer")
local supervisor = require("supervisor.supervisor")
local svsessions = require("supervisor.session.svsessions")
local SUPERVISOR_VERSION = "v0.15.9"
local SUPERVISOR_VERSION = "v0.17.5"
local println = util.println
local println_ts = util.println_ts
@ -25,8 +31,11 @@ local println_ts = util.println_ts
local cfv = util.new_validator()
cfv.assert_port(config.SCADA_DEV_LISTEN)
cfv.assert_port(config.SCADA_SV_CTL_LISTEN)
cfv.assert_channel(config.SVR_CHANNEL)
cfv.assert_channel(config.PLC_CHANNEL)
cfv.assert_channel(config.RTU_CHANNEL)
cfv.assert_channel(config.CRD_CHANNEL)
cfv.assert_channel(config.PKT_CHANNEL)
cfv.assert_type_int(config.TRUSTED_RANGE)
cfv.assert_type_num(config.PLC_TIMEOUT)
cfv.assert_min(config.PLC_TIMEOUT, 2)
@ -79,6 +88,9 @@ local function main()
-- startup
----------------------------------------
-- record firmware versions and ID
databus.tx_versions(SUPERVISOR_VERSION, comms.version)
-- mount connected devices
ppm.mount_all()
@ -89,9 +101,22 @@ local function main()
return
end
-- start comms, open all channels
local superv_comms = supervisor.comms(SUPERVISOR_VERSION, config.NUM_REACTORS, config.REACTOR_COOLING, modem,
config.SCADA_DEV_LISTEN, config.SCADA_SV_CTL_LISTEN, config.TRUSTED_RANGE)
databus.tx_hw_modem(true)
-- start UI
local fp_ok, message = pcall(renderer.start_ui)
if not fp_ok then
renderer.close_ui()
println_ts(util.c("UI error: ", message))
log.error(util.c("GUI crashed with error ", message))
else
-- redefine println_ts local to not print as we have the front panel running
println_ts = function (_) end
end
-- start comms
local superv_comms = supervisor.comms(SUPERVISOR_VERSION, modem, fp_ok)
-- base loop clock (6.67Hz, 3 ticks)
local MAIN_CLOCK = 0.15
@ -100,6 +125,9 @@ local function main()
-- start clock
loop_clock.start()
-- halve the rate heartbeat LED flash
local heartbeat_toggle = true
-- event loop
while true do
local event, param1, param2, param3, param4, param5 = util.pull_event()
@ -114,6 +142,7 @@ local function main()
if device == modem then
println_ts("wireless modem disconnected!")
log.warning("comms modem disconnected")
databus.tx_hw_modem(false)
else
log.warning("non-comms modem disconnected")
end
@ -131,6 +160,8 @@ local function main()
println_ts("wireless modem reconnected.")
log.info("comms modem reconnected")
databus.tx_hw_modem(true)
else
log.info("wired modem reconnected")
end
@ -139,6 +170,9 @@ local function main()
elseif event == "timer" and loop_clock.is_clock(param1) then
-- main loop tick
if heartbeat_toggle then databus.heartbeat() end
heartbeat_toggle = not heartbeat_toggle
-- iterate sessions
svsessions.iterate_all()
@ -149,10 +183,16 @@ local function main()
elseif event == "timer" then
-- a non-clock timer event, check watchdogs
svsessions.check_all_watchdogs(param1)
-- notify timer callback dispatcher
tcd.handle(param1)
elseif event == "modem_message" then
-- got a packet
local packet = superv_comms.parse_packet(param1, param2, param3, param4, param5)
superv_comms.handle_packet(packet)
elseif event == "mouse_click" or event == "mouse_up" or event == "mouse_drag" or event == "mouse_scroll" then
-- handle a mouse event
renderer.handle_mouse(core.events.new_mouse_event(event, param1, param2, param3))
end
-- check for termination request
@ -165,8 +205,15 @@ local function main()
end
end
println_ts("exited")
renderer.close_ui()
util.println_ts("exited")
log.info("exited")
end
if not xpcall(main, crash.handler) then crash.exit() else log.close() end
if not xpcall(main, crash.handler) then
pcall(renderer.close_ui)
crash.exit()
else
log.close()
end

View File

@ -2,6 +2,8 @@ local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
local config = require("supervisor.config")
local svsessions = require("supervisor.session.svsessions")
local supervisor = {}
@ -11,64 +13,59 @@ local DEVICE_TYPE = comms.DEVICE_TYPE
local ESTABLISH_ACK = comms.ESTABLISH_ACK
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local println = util.println
-- supervisory controller communications
---@nodiscard
---@param _version string supervisor version
---@param num_reactors integer number of reactors
---@param cooling_conf table cooling configuration table
---@param modem table modem device
---@param dev_listen integer listening port for PLC/RTU devices
---@param svctl_listen integer listening port for supervisor access
---@param range integer trusted device connection range
---@param fp_ok boolean if the front panel UI is running
---@diagnostic disable-next-line: unused-local
function supervisor.comms(_version, num_reactors, cooling_conf, modem, dev_listen, svctl_listen, range)
function supervisor.comms(_version, modem, fp_ok)
-- print a log message to the terminal as long as the UI isn't running
local function println(message) if not fp_ok then util.println_ts(message) end end
-- channel list from config
local svr_channel = config.SVR_CHANNEL
local plc_channel = config.PLC_CHANNEL
local rtu_channel = config.RTU_CHANNEL
local crd_channel = config.CRD_CHANNEL
local pkt_channel = config.PKT_CHANNEL
-- configuration data
local num_reactors = config.NUM_REACTORS
local cooling_conf = config.REACTOR_COOLING
local self = {
last_est_acks = {}
}
comms.set_trusted_range(range)
comms.set_trusted_range(config.TRUSTED_RANGE)
-- PRIVATE FUNCTIONS --
-- configure modem channels
local function _conf_channels()
modem.closeAll()
modem.open(dev_listen)
modem.open(svctl_listen)
modem.open(svr_channel)
end
_conf_channels()
-- link modem to svsessions
svsessions.init(modem, num_reactors, cooling_conf)
-- pass modem, status, and config data to svsessions
svsessions.init(modem, fp_ok, num_reactors, cooling_conf)
-- send an establish request response to a PLC/RTU
---@param dest integer
---@param msg table
local function _send_dev_establish(seq_id, dest, msg)
-- send an establish request response
---@param packet scada_packet
---@param ack ESTABLISH_ACK
---@param data? any optional data
local function _send_establish(packet, ack, data)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(SCADA_MGMT_TYPE.ESTABLISH, msg)
s_pkt.make(seq_id, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
m_pkt.make(SCADA_MGMT_TYPE.ESTABLISH, { ack, data })
s_pkt.make(packet.src_addr(), packet.seq_num() + 1, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
modem.transmit(dest, dev_listen, s_pkt.raw_sendable())
end
-- send supervisor control access connection establish response
---@param seq_id integer
---@param dest integer
---@param msg table
local function _send_svctl_establish(seq_id, dest, msg)
local s_pkt = comms.scada_packet()
local c_pkt = comms.mgmt_packet()
c_pkt.make(SCADA_MGMT_TYPE.ESTABLISH, msg)
s_pkt.make(seq_id, PROTOCOL.SCADA_MGMT, c_pkt.raw_sendable())
modem.transmit(dest, svctl_listen, s_pkt.raw_sendable())
modem.transmit(packet.remote_channel(), svr_channel, s_pkt.raw_sendable())
self.last_est_acks[packet.src_addr()] = ack
end
-- PUBLIC FUNCTIONS --
@ -136,17 +133,94 @@ function supervisor.comms(_version, num_reactors, cooling_conf, modem, dev_liste
---@param packet modbus_frame|rplc_frame|mgmt_frame|crdn_frame|nil
function public.handle_packet(packet)
if packet ~= nil then
local l_port = packet.scada_frame.local_port()
local r_port = packet.scada_frame.remote_port()
local l_chan = packet.scada_frame.local_channel()
local r_chan = packet.scada_frame.remote_channel()
local src_addr = packet.scada_frame.src_addr()
local protocol = packet.scada_frame.protocol()
-- device (RTU/PLC) listening channel
if l_port == dev_listen then
if l_chan ~= svr_channel then
log.debug("received packet on unconfigured channel " .. l_chan, true)
elseif r_chan == plc_channel then
-- look for an associated session
local session = svsessions.find_plc_session(src_addr)
if protocol == PROTOCOL.RPLC then
---@cast packet rplc_frame
-- reactor PLC packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
else
-- unknown session, force a re-link
log.debug("PLC_ESTABLISH: no session but not an establish, forcing relink")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
elseif protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- establish a new session
local last_ack = self.last_est_acks[src_addr]
-- validate packet and continue
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
local comms_v = packet.data[1]
local firmware_v = packet.data[2]
local dev_type = packet.data[3]
if comms_v ~= comms.version then
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping PLC establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
elseif dev_type == DEVICE_TYPE.PLC then
-- PLC linking request
if packet.length == 4 and type(packet.data[4]) == "number" then
local reactor_id = packet.data[4]
local plc_id = svsessions.establish_plc_session(src_addr, reactor_id, firmware_v)
if plc_id == false then
-- reactor already has a PLC assigned
if last_ack ~= ESTABLISH_ACK.COLLISION then
log.warning(util.c("PLC_ESTABLISH: assignment collision with reactor ", reactor_id))
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.COLLISION)
else
-- got an ID; assigned to a reactor successfully
println(util.c("PLC (", firmware_v, ") [@", src_addr, "] \xbb reactor ", reactor_id, " connected"))
log.info(util.c("PLC_ESTABLISH: PLC (", firmware_v, ") [@", src_addr, "] reactor unit ", reactor_id, " PLC connected with session ID ", plc_id))
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
end
else
log.debug("PLC_ESTABLISH: packet length mismatch/bad parameter type")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug(util.c("illegal establish packet for device ", dev_type, " on PLC channel"))
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug("invalid establish packet (on PLC channel)")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
-- any other packet should be session related, discard it
log.debug(util.c("discarding PLC SCADA_MGMT packet without a known session from computer ", src_addr))
end
else
log.debug(util.c("illegal packet type ", protocol, " on PLC channel"))
end
elseif r_chan == rtu_channel then
-- look for an associated session
local session = svsessions.find_rtu_session(src_addr)
if protocol == PROTOCOL.MODBUS_TCP then
---@cast packet modbus_frame
-- look for an associated session
local session = svsessions.find_rtu_session(r_port)
-- MODBUS response
if session ~= nil then
-- pass the packet onto the session handler
@ -155,105 +229,59 @@ function supervisor.comms(_version, num_reactors, cooling_conf, modem, dev_liste
-- any other packet should be session related, discard it
log.debug("discarding MODBUS_TCP packet without a known session")
end
elseif protocol == PROTOCOL.RPLC then
---@cast packet rplc_frame
-- look for an associated session
local session = svsessions.find_plc_session(r_port)
-- reactor PLC packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
else
-- unknown session, force a re-link
log.debug("PLC_ESTABLISH: no session but not an establish, forcing relink")
_send_dev_establish(packet.scada_frame.seq_num() + 1, r_port, { ESTABLISH_ACK.DENY })
end
elseif protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- look for an associated session
local session = svsessions.find_device_session(r_port)
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- establish a new session
local next_seq_id = packet.scada_frame.seq_num() + 1
local last_ack = self.last_est_acks[src_addr]
-- validate packet and continue
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
local comms_v = packet.data[1]
local comms_v = packet.data[1]
local firmware_v = packet.data[2]
local dev_type = packet.data[3]
local dev_type = packet.data[3]
if comms_v ~= comms.version then
if self.last_est_acks[r_port] ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping device establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
self.last_est_acks[r_port] = ESTABLISH_ACK.BAD_VERSION
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping RTU establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
end
_send_dev_establish(next_seq_id, r_port, { ESTABLISH_ACK.BAD_VERSION })
elseif dev_type == DEVICE_TYPE.PLC then
-- PLC linking request
if packet.length == 4 and type(packet.data[4]) == "number" then
local reactor_id = packet.data[4]
local plc_id = svsessions.establish_plc_session(l_port, r_port, reactor_id, firmware_v)
if plc_id == false then
-- reactor already has a PLC assigned
if self.last_est_acks[r_port] ~= ESTABLISH_ACK.COLLISION then
log.warning(util.c("PLC_ESTABLISH: assignment collision with reactor ", reactor_id))
self.last_est_acks[r_port] = ESTABLISH_ACK.COLLISION
end
_send_dev_establish(next_seq_id, r_port, { ESTABLISH_ACK.COLLISION })
else
-- got an ID; assigned to a reactor successfully
println(util.c("PLC (", firmware_v, ") [:", r_port, "] \xbb reactor ", reactor_id, " connected"))
log.info(util.c("PLC_ESTABLISH: PLC (", firmware_v, ") [:", r_port, "] reactor unit ", reactor_id, " PLC connected with session ID ", plc_id))
_send_dev_establish(next_seq_id, r_port, { ESTABLISH_ACK.ALLOW })
self.last_est_acks[r_port] = ESTABLISH_ACK.ALLOW
end
else
log.debug("PLC_ESTABLISH: packet length mismatch/bad parameter type")
_send_dev_establish(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
elseif dev_type == DEVICE_TYPE.RTU then
if packet.length == 4 then
-- this is an RTU advertisement for a new session
local rtu_advert = packet.data[4]
local s_id = svsessions.establish_rtu_session(l_port, r_port, rtu_advert, firmware_v)
local s_id = svsessions.establish_rtu_session(src_addr, rtu_advert, firmware_v)
println(util.c("RTU (", firmware_v, ") [:", r_port, "] \xbb connected"))
log.info(util.c("RTU_ESTABLISH: RTU (",firmware_v, ") [:", r_port, "] connected with session ID ", s_id))
_send_dev_establish(next_seq_id, r_port, { ESTABLISH_ACK.ALLOW })
println(util.c("RTU (", firmware_v, ") [@", src_addr, "] \xbb connected"))
log.info(util.c("RTU_ESTABLISH: RTU (",firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
else
log.debug("RTU_ESTABLISH: packet length mismatch")
_send_dev_establish(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug(util.c("illegal establish packet for device ", dev_type, " on PLC/RTU listening channel"))
_send_dev_establish(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
log.debug(util.c("illegal establish packet for device ", dev_type, " on RTU channel"))
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug("invalid establish packet (on PLC/RTU listening channel)")
_send_dev_establish(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
log.debug("invalid establish packet (on RTU channel)")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
-- any other packet should be session related, discard it
log.debug(util.c(r_port, "->", l_port, ": discarding SCADA_MGMT packet without a known session"))
log.debug(util.c("discarding RTU SCADA_MGMT packet without a known session from computer ", src_addr))
end
else
log.debug("illegal packet type " .. protocol .. " on device listening channel")
log.debug(util.c("illegal packet type ", protocol, " on RTU channel"))
end
-- coordinator listening channel
elseif l_port == svctl_listen then
elseif r_chan == crd_channel then
-- look for an associated session
local session = svsessions.find_svctl_session(r_port)
local session = svsessions.find_crd_session(src_addr)
if protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
@ -263,65 +291,53 @@ function supervisor.comms(_version, num_reactors, cooling_conf, modem, dev_liste
session.in_queue.push_packet(packet)
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- establish a new session
local next_seq_id = packet.scada_frame.seq_num() + 1
local last_ack = self.last_est_acks[src_addr]
-- validate packet and continue
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
local comms_v = packet.data[1]
local comms_v = packet.data[1]
local firmware_v = packet.data[2]
local dev_type = packet.data[3]
local dev_type = packet.data[3]
if comms_v ~= comms.version then
if self.last_est_acks[r_port] ~= ESTABLISH_ACK.BAD_VERSION then
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping coordinator establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
self.last_est_acks[r_port] = ESTABLISH_ACK.BAD_VERSION
end
_send_svctl_establish(next_seq_id, r_port, { ESTABLISH_ACK.BAD_VERSION })
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
elseif dev_type == DEVICE_TYPE.CRDN then
-- this is an attempt to establish a new coordinator session
local s_id = svsessions.establish_coord_session(l_port, r_port, firmware_v)
local s_id = svsessions.establish_crd_session(src_addr, firmware_v)
if s_id ~= false then
local config = { num_reactors }
local cfg = { num_reactors }
for i = 1, #cooling_conf do
table.insert(config, cooling_conf[i].BOILERS)
table.insert(config, cooling_conf[i].TURBINES)
table.insert(cfg, cooling_conf[i].BOILERS)
table.insert(cfg, cooling_conf[i].TURBINES)
end
println(util.c("CRD (", firmware_v, ") [:", r_port, "] \xbb connected"))
log.info(util.c("SVCTL_ESTABLISH: coordinator (", firmware_v, ") [:", r_port, "] connected with session ID ", s_id))
println(util.c("CRD (", firmware_v, ") [@", src_addr, "] \xbb connected"))
log.info(util.c("CRD_ESTABLISH: coordinator (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
_send_svctl_establish(next_seq_id, r_port, { ESTABLISH_ACK.ALLOW, config })
self.last_est_acks[r_port] = ESTABLISH_ACK.ALLOW
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW, cfg)
else
if self.last_est_acks[r_port] ~= ESTABLISH_ACK.COLLISION then
log.info("SVCTL_ESTABLISH: denied new coordinator due to already being connected to another coordinator")
self.last_est_acks[r_port] = ESTABLISH_ACK.COLLISION
if last_ack ~= ESTABLISH_ACK.COLLISION then
log.info("CRD_ESTABLISH: denied new coordinator [@" .. src_addr .. "] due to already being connected to another coordinator")
end
_send_svctl_establish(next_seq_id, r_port, { ESTABLISH_ACK.COLLISION })
_send_establish(packet.scada_frame, ESTABLISH_ACK.COLLISION)
end
elseif dev_type == DEVICE_TYPE.PKT then
-- this is an attempt to establish a new pocket diagnostic session
local s_id = svsessions.establish_diag_session(l_port, r_port, firmware_v)
println(util.c("PKT (", firmware_v, ") [:", r_port, "] \xbb connected"))
log.info(util.c("SVCTL_ESTABLISH: pocket (", firmware_v, ") [:", r_port, "] connected with session ID ", s_id))
_send_svctl_establish(next_seq_id, r_port, { ESTABLISH_ACK.ALLOW })
self.last_est_acks[r_port] = ESTABLISH_ACK.ALLOW
else
log.debug(util.c("illegal establish packet for device ", dev_type, " on SVCTL listening channel"))
_send_svctl_establish(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
log.debug(util.c("illegal establish packet for device ", dev_type, " on coordinator channel"))
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug("SVCTL_ESTABLISH: establish packet length mismatch")
_send_svctl_establish(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
log.debug("CRD_ESTABLISH: establish packet length mismatch")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
-- any other packet should be session related, discard it
log.debug(r_port .. "->" .. l_port .. ": discarding SCADA_MGMT packet without a known session")
log.debug(util.c("discarding coordinator SCADA_MGMT packet without a known session from computer ", src_addr))
end
elseif protocol == PROTOCOL.SCADA_CRDN then
---@cast packet crdn_frame
@ -331,13 +347,72 @@ function supervisor.comms(_version, num_reactors, cooling_conf, modem, dev_liste
session.in_queue.push_packet(packet)
else
-- any other packet should be session related, discard it
log.debug(r_port .. "->" .. l_port .. ": discarding SCADA_CRDN packet without a known session")
log.debug(util.c("discarding coordinator SCADA_CRDN packet without a known session from computer ", src_addr))
end
else
log.debug("illegal packet type " .. protocol .. " on coordinator listening channel")
log.debug(util.c("illegal packet type ", protocol, " on coordinator channel"))
end
elseif r_chan == pkt_channel then
-- look for an associated session
local session = svsessions.find_pdg_session(src_addr)
if protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- establish a new session
local last_ack = self.last_est_acks[src_addr]
-- validate packet and continue
if packet.length >= 3 and type(packet.data[1]) == "string" and type(packet.data[2]) == "string" then
local comms_v = packet.data[1]
local firmware_v = packet.data[2]
local dev_type = packet.data[3]
if comms_v ~= comms.version then
if last_ack ~= ESTABLISH_ACK.BAD_VERSION then
log.info(util.c("dropping PDG establish packet with incorrect comms version v", comms_v, " (expected v", comms.version, ")"))
end
_send_establish(packet.scada_frame, ESTABLISH_ACK.BAD_VERSION)
elseif dev_type == DEVICE_TYPE.PKT then
-- this is an attempt to establish a new pocket diagnostic session
local s_id = svsessions.establish_pdg_session(src_addr, firmware_v)
println(util.c("PKT (", firmware_v, ") [@", src_addr, "] \xbb connected"))
log.info(util.c("PDG_ESTABLISH: pocket (", firmware_v, ") [@", src_addr, "] connected with session ID ", s_id))
_send_establish(packet.scada_frame, ESTABLISH_ACK.ALLOW)
else
log.debug(util.c("illegal establish packet for device ", dev_type, " on pocket channel"))
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
log.debug("PDG_ESTABLISH: establish packet length mismatch")
_send_establish(packet.scada_frame, ESTABLISH_ACK.DENY)
end
else
-- any other packet should be session related, discard it
log.debug(util.c("discarding pocket SCADA_MGMT packet without a known session from computer ", src_addr))
end
elseif protocol == PROTOCOL.SCADA_CRDN then
---@cast packet crdn_frame
-- coordinator packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
else
-- any other packet should be session related, discard it
log.debug(util.c("discarding pocket SCADA_CRDN packet without a known session from computer ", src_addr))
end
else
log.debug(util.c("illegal packet type ", protocol, " on pocket channel"))
end
else
log.debug("received packet on unconfigured channel " .. l_port, true)
log.debug("received packet for unknown channel " .. r_chan, true)
end
end
end

View File

@ -506,7 +506,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
--#region
-- engage automatic control
function public.a_engage()
function public.auto_engage()
self.auto_engaged = true
if self.plc_i ~= nil then
self.plc_i.auto_lock(true)
@ -514,7 +514,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
end
-- disengage automatic control
function public.a_disengage()
function public.auto_disengage()
self.auto_engaged = false
if self.plc_i ~= nil then
self.plc_i.auto_lock(false)
@ -526,7 +526,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
-- if it is degraded or not ready, the limit will be 0
---@nodiscard
---@return integer lim_br100
function public.a_get_effective_limit()
function public.auto_get_effective_limit()
if (not self.db.control.ready) or self.db.control.degraded or self.plc_cache.rps_trip then
self.db.control.br100 = 0
return 0
@ -537,7 +537,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
-- set the automatic burn rate based on the last set burn rate in 100ths
---@param ramp boolean true to ramp to rate, false to set right away
function public.a_commit_br100(ramp)
function public.auto_commit_br100(ramp)
if self.auto_engaged then
if self.plc_i ~= nil then
self.plc_i.auto_set_burn(self.db.control.br100 / 100, ramp)
@ -550,16 +550,16 @@ function unit.new(reactor_id, num_boilers, num_turbines)
-- check if ramping is complete (burn rate is same as target)
---@nodiscard
---@return boolean complete
function public.a_ramp_complete()
function public.auto_ramp_complete()
if self.plc_i ~= nil then
return self.plc_i.is_ramp_complete() or
(self.plc_i.get_status().act_burn_rate == 0 and self.db.control.br100 == 0) or
public.a_get_effective_limit() == 0
public.auto_get_effective_limit() == 0
else return true end
end
-- perform an automatic SCRAM
function public.a_scram()
function public.auto_scram()
if self.plc_s ~= nil then
self.db.control.br100 = 0
self.plc_s.in_queue.push_command(PLC_S_CMDS.ASCRAM)
@ -567,7 +567,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
end
-- queue a command to clear timeout/auto-scram if set
function public.a_cond_rps_reset()
function public.auto_cond_rps_reset()
if self.plc_s ~= nil and self.plc_i ~= nil and (not self.auto_was_alarmed) and (not self.emcool_opened) then
local rps = self.plc_i.get_rps()
if rps.timeout or rps.automatic then

View File

@ -549,7 +549,7 @@ function logic.update_auto_safety(public, self)
end
if alarmed and not self.plc_cache.rps_status.automatic then
public.a_scram()
public.auto_scram()
end
self.auto_was_alarmed = alarmed

View File

@ -38,7 +38,7 @@ local pkt = comms.modbus_packet()
---@diagnostic disable-next-line: param-type-mismatch
pkt.make(1, 2, 7, {0, 1, 2, 3, 4, 5, 6, 7, 8, 9})
local spkt = comms.scada_packet()
spkt.make(1, 1, pkt.raw_sendable())
spkt.make(0, 1, 1, pkt.raw_sendable())
start = util.time()
local data = textutils.serialize(spkt.raw_sendable(), { allow_repetitions = true, compact = true })