mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
#412 optionally disable SPS at low power
This commit is contained in:
parent
6f768ef6b3
commit
50bf057ca6
@ -92,6 +92,7 @@ function iocontrol.init(conf, comms, temp_scale)
|
||||
---@type WASTE_PRODUCT
|
||||
auto_current_waste_product = types.WASTE_PRODUCT.PLUTONIUM,
|
||||
auto_pu_fallback_active = false,
|
||||
auto_sps_disabled = false,
|
||||
|
||||
radiation = types.new_zero_radiation_reading(),
|
||||
|
||||
@ -593,7 +594,7 @@ function iocontrol.update_facility_status(status)
|
||||
|
||||
local ctl_status = status[1]
|
||||
|
||||
if type(ctl_status) == "table" and #ctl_status == 16 then
|
||||
if type(ctl_status) == "table" and #ctl_status == 17 then
|
||||
fac.all_sys_ok = ctl_status[1]
|
||||
fac.auto_ready = ctl_status[2]
|
||||
|
||||
@ -644,9 +645,11 @@ function iocontrol.update_facility_status(status)
|
||||
|
||||
fac.auto_current_waste_product = ctl_status[15]
|
||||
fac.auto_pu_fallback_active = ctl_status[16]
|
||||
fac.auto_sps_disabled = ctl_status[17]
|
||||
|
||||
fac.ps.publish("current_waste_product", fac.auto_current_waste_product)
|
||||
fac.ps.publish("pu_fallback_active", fac.auto_pu_fallback_active)
|
||||
fac.ps.publish("sps_disabled_low_power", fac.auto_sps_disabled)
|
||||
else
|
||||
log.debug(log_header .. "control status not a table or length mismatch")
|
||||
valid = false
|
||||
|
@ -29,7 +29,8 @@ local self = {
|
||||
gen_target = 0.0,
|
||||
limits = {},
|
||||
waste_product = PRODUCT.PLUTONIUM,
|
||||
pu_fallback = false
|
||||
pu_fallback = false,
|
||||
sps_low_power = false
|
||||
},
|
||||
waste_modes = {},
|
||||
priority_groups = {}
|
||||
@ -65,6 +66,7 @@ function process.init(iocontrol, coord_comms)
|
||||
ctl_proc.limits = config.limits
|
||||
ctl_proc.waste_product = config.waste_product
|
||||
ctl_proc.pu_fallback = config.pu_fallback
|
||||
ctl_proc.sps_low_power = config.sps_low_power
|
||||
|
||||
self.io.facility.ps.publish("process_mode", ctl_proc.mode)
|
||||
self.io.facility.ps.publish("process_burn_target", ctl_proc.burn_target)
|
||||
@ -72,6 +74,7 @@ function process.init(iocontrol, coord_comms)
|
||||
self.io.facility.ps.publish("process_gen_target", ctl_proc.gen_target)
|
||||
self.io.facility.ps.publish("process_waste_product", ctl_proc.waste_product)
|
||||
self.io.facility.ps.publish("process_pu_fallback", ctl_proc.pu_fallback)
|
||||
self.io.facility.ps.publish("process_sps_low_power", ctl_proc.sps_low_power)
|
||||
|
||||
for id = 1, math.min(#ctl_proc.limits, self.io.facility.num_units) do
|
||||
local unit = self.io.units[id] ---@type ioctl_unit
|
||||
@ -83,6 +86,7 @@ function process.init(iocontrol, coord_comms)
|
||||
-- notify supervisor of auto waste config
|
||||
self.comms.send_fac_command(FAC_COMMAND.SET_WASTE_MODE, ctl_proc.waste_product)
|
||||
self.comms.send_fac_command(FAC_COMMAND.SET_PU_FB, ctl_proc.pu_fallback)
|
||||
self.comms.send_fac_command(FAC_COMMAND.SET_SPS_LP, ctl_proc.sps_low_power)
|
||||
end
|
||||
|
||||
-- unit waste states
|
||||
@ -259,6 +263,18 @@ function process.set_pu_fallback(enabled)
|
||||
_write_auto_config()
|
||||
end
|
||||
|
||||
-- set automatic process control SPS usage at low power
|
||||
---@param enabled boolean whether to enable SPS usage at low power
|
||||
function process.set_sps_low_power(enabled)
|
||||
self.comms.send_fac_command(FAC_COMMAND.SET_SPS_LP, enabled)
|
||||
|
||||
log.debug(util.c("PROCESS: SET SPS LOW POWER ", enabled))
|
||||
|
||||
-- update config table and save
|
||||
self.control_states.process.sps_low_power = enabled
|
||||
_write_auto_config()
|
||||
end
|
||||
|
||||
-- save process control settings
|
||||
---@param mode PROCESS control mode
|
||||
---@param burn_target number burn rate target
|
||||
|
@ -341,31 +341,23 @@ local function new_view(root, x, y)
|
||||
status.register(facility.ps, "current_waste_product", status.update)
|
||||
|
||||
local waste_prod = RadioButton{parent=rect,x=2,y=3,options=style.waste.options,callback=process.set_process_waste,radio_colors=cpair(style.theme.accent_dark,style.theme.accent_light),select_color=colors.brown}
|
||||
local pu_fallback = Checkbox{parent=rect,x=2,y=7,label="Pu Fallback",callback=process.set_pu_fallback,box_fg_bg=cpair(colors.green,style.theme.checkbox_bg)}
|
||||
|
||||
waste_prod.register(facility.ps, "process_waste_product", waste_prod.set_value)
|
||||
pu_fallback.register(facility.ps, "process_pu_fallback", pu_fallback.set_value)
|
||||
local fb_active = IndicatorLight{parent=rect,x=2,y=7,label="Fallback Active",colors=ind_wht}
|
||||
local sps_disabled = IndicatorLight{parent=rect,x=2,y=8,label="SPS Disabled LC",colors=ind_yel}
|
||||
|
||||
local fb_active = IndicatorLight{parent=rect,x=2,y=9,label="Fallback Active",colors=ind_wht}
|
||||
local pu_fallback = Checkbox{parent=rect,x=2,y=10,label="Pu Fallback",callback=process.set_pu_fallback,box_fg_bg=cpair(colors.brown,style.theme.checkbox_bg)}
|
||||
|
||||
TextBox{parent=rect,x=2,y=12,height=3,text="Switch to Pu when SNAs cannot keep up with waste.",fg_bg=style.label}
|
||||
|
||||
local lc_sps = Checkbox{parent=rect,x=2,y=16,label="Low Charge SPS",callback=process.set_sps_low_power,box_fg_bg=cpair(colors.brown,style.theme.checkbox_bg)}
|
||||
|
||||
TextBox{parent=rect,x=2,y=18,height=3,text="Use SPS at low charge, otherwise switches to Po.",fg_bg=style.label}
|
||||
|
||||
fb_active.register(facility.ps, "pu_fallback_active", fb_active.update)
|
||||
|
||||
TextBox{parent=rect,x=2,y=11,text="Plutonium Rate",height=1,width=17,fg_bg=style.label}
|
||||
local pu_rate = DataIndicator{parent=rect,x=2,label="",unit="mB/t",format="%12.2f",value=0,lu_colors=lu_cpair,fg_bg=s_field,width=17}
|
||||
|
||||
TextBox{parent=rect,x=2,y=14,text="Polonium Rate",height=1,width=17,fg_bg=style.label}
|
||||
local po_rate = DataIndicator{parent=rect,x=2,label="",unit="mB/t",format="%12.2f",value=0,lu_colors=lu_cpair,fg_bg=s_field,width=17}
|
||||
|
||||
TextBox{parent=rect,x=2,y=17,text="Antimatter Rate",height=1,width=17,fg_bg=style.label}
|
||||
local am_rate = DataIndicator{parent=rect,x=2,label="",unit="\xb5B/t",format="%12d",value=0,lu_colors=lu_cpair,fg_bg=s_field,width=17}
|
||||
|
||||
pu_rate.register(facility.ps, "pu_rate", pu_rate.update)
|
||||
po_rate.register(facility.ps, "po_rate", po_rate.update)
|
||||
am_rate.register(facility.ps, "am_rate", am_rate.update)
|
||||
|
||||
local sna_count = DataIndicator{parent=rect,x=2,y=20,label="Linked SNAs:",format="%4d",value=0,lu_colors=lu_cpair,width=17}
|
||||
|
||||
sna_count.register(facility.ps, "sna_count", sna_count.update)
|
||||
sps_disabled.register(facility.ps, "sps_disabled_low_power", sps_disabled.update)
|
||||
waste_prod.register(facility.ps, "process_waste_product", waste_prod.set_value)
|
||||
pu_fallback.register(facility.ps, "process_pu_fallback", pu_fallback.set_value)
|
||||
lc_sps.register(facility.ps, "process_sps_low_power", lc_sps.set_value)
|
||||
end
|
||||
|
||||
return new_view
|
||||
|
@ -97,7 +97,8 @@ local FAC_COMMAND = {
|
||||
START = 2, -- start automatic process control
|
||||
ACK_ALL_ALARMS = 3, -- acknowledge all alarms on all units
|
||||
SET_WASTE_MODE = 4, -- set automatic waste processing mode
|
||||
SET_PU_FB = 5 -- set plutonium fallback mode
|
||||
SET_PU_FB = 5, -- set plutonium fallback mode
|
||||
SET_SPS_LP = 6 -- set SPS at low power mode
|
||||
}
|
||||
|
||||
---@enum UNIT_COMMAND
|
||||
|
@ -120,6 +120,8 @@ function facility.new(config, cooling_conf)
|
||||
waste_product = WASTE.PLUTONIUM,
|
||||
current_waste_product = WASTE.PLUTONIUM,
|
||||
pu_fallback = false,
|
||||
sps_low_power = false,
|
||||
disabled_sps = false,
|
||||
-- alarm tones
|
||||
tone_states = {},
|
||||
test_tone_set = false,
|
||||
@ -840,9 +842,25 @@ function facility.new(config, cooling_conf)
|
||||
end
|
||||
|
||||
-- update waste product
|
||||
if self.waste_product == WASTE.PLUTONIUM or (self.pu_fallback and insufficent_po_rate) then
|
||||
|
||||
self.current_waste_product = self.waste_product
|
||||
|
||||
if (not self.sps_low_power) and (self.waste_product == WASTE.ANTI_MATTER) and (self.induction[1] ~= nil) then
|
||||
local db = self.induction[1].get_db() ---@type imatrix_session_db
|
||||
|
||||
if db.tanks.energy_fill >= 0.15 then
|
||||
self.disabled_sps = false
|
||||
elseif self.disabled_sps or ((db.tanks.last_update > 0) and (db.tanks.energy_fill < 0.1)) then
|
||||
self.disabled_sps = true
|
||||
self.current_waste_product = WASTE.POLONIUM
|
||||
end
|
||||
else
|
||||
self.disabled_sps = false
|
||||
end
|
||||
|
||||
if self.pu_fallback and insufficent_po_rate then
|
||||
self.current_waste_product = WASTE.PLUTONIUM
|
||||
else self.current_waste_product = self.waste_product end
|
||||
end
|
||||
|
||||
-- make sure dynamic tanks are allowing outflow if required
|
||||
-- set all, rather than trying to determine which is for which (simpler & safer)
|
||||
@ -1099,6 +1117,14 @@ function facility.new(config, cooling_conf)
|
||||
return self.pu_fallback
|
||||
end
|
||||
|
||||
-- enable/disable SPS at low power
|
||||
---@param enabled boolean requested state
|
||||
---@return boolean enabled newly set value
|
||||
function public.set_sps_low_power(enabled)
|
||||
self.sps_low_power = enabled == true
|
||||
return self.sps_low_power
|
||||
end
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region Diagnostic Testing
|
||||
@ -1203,7 +1229,8 @@ function facility.new(config, cooling_conf)
|
||||
self.status_text[2],
|
||||
self.group_map,
|
||||
self.current_waste_product,
|
||||
(self.current_waste_product == WASTE.PLUTONIUM) and (self.waste_product ~= WASTE.PLUTONIUM)
|
||||
self.pu_fallback and (self.current_waste_product == WASTE.PLUTONIUM) and (self.waste_product ~= WASTE.PLUTONIUM),
|
||||
self.disabled_sps
|
||||
}
|
||||
end
|
||||
|
||||
|
@ -270,6 +270,12 @@ function coordinator.new_session(id, s_addr, in_queue, out_queue, timeout, facil
|
||||
else
|
||||
log.debug(log_header .. "CRDN set pu fallback packet length mismatch")
|
||||
end
|
||||
elseif cmd == FAC_COMMAND.SET_SPS_LP then
|
||||
if pkt.length == 2 then
|
||||
_send(CRDN_TYPE.FAC_CMD, { cmd, facility.set_sps_low_power(pkt.data[2]) })
|
||||
else
|
||||
log.debug(log_header .. "CRDN set sps low power packet length mismatch")
|
||||
end
|
||||
else
|
||||
log.debug(log_header .. "CRDN facility command unknown")
|
||||
end
|
||||
|
Loading…
Reference in New Issue
Block a user