#366 added idling to config and adjusted/fixed some behaviors
This commit is contained in:
parent
2aa52d2e2c
commit
878c3b92e1
@ -91,6 +91,7 @@ local tmp_cfg = {
|
||||
CoolingConfig = {},
|
||||
FacilityTankMode = 0,
|
||||
FacilityTankDefs = {},
|
||||
ExtChargeIdling = false,
|
||||
SVR_Channel = nil, ---@type integer
|
||||
PLC_Channel = nil, ---@type integer
|
||||
RTU_Channel = nil, ---@type integer
|
||||
@ -120,6 +121,7 @@ local fields = {
|
||||
{ "CoolingConfig", "Cooling Configuration", {} },
|
||||
{ "FacilityTankMode", "Facility Tank Mode", 0 },
|
||||
{ "FacilityTankDefs", "Facility Tank Definitions", {} },
|
||||
{ "ExtChargeIdling", "Extended Charge Idling", false },
|
||||
{ "SVR_Channel", "SVR Channel", 16240 },
|
||||
{ "PLC_Channel", "PLC Channel", 16241 },
|
||||
{ "RTU_Channel", "RTU Channel", 16242 },
|
||||
@ -222,8 +224,9 @@ local function config_view(display)
|
||||
local svr_c_4 = Div{parent=svr_cfg,x=2,y=4,width=49}
|
||||
local svr_c_5 = Div{parent=svr_cfg,x=2,y=4,width=49}
|
||||
local svr_c_6 = Div{parent=svr_cfg,x=2,y=4,width=49}
|
||||
local svr_c_7 = Div{parent=svr_cfg,x=2,y=4,width=49}
|
||||
|
||||
local svr_pane = MultiPane{parent=svr_cfg,x=1,y=4,panes={svr_c_1,svr_c_2,svr_c_3,svr_c_4,svr_c_5,svr_c_6}}
|
||||
local svr_pane = MultiPane{parent=svr_cfg,x=1,y=4,panes={svr_c_1,svr_c_2,svr_c_3,svr_c_4,svr_c_5,svr_c_6,svr_c_7}}
|
||||
|
||||
TextBox{parent=svr_cfg,x=1,y=2,height=1,text=" Facility Configuration",fg_bg=cpair(colors.black,colors.yellow)}
|
||||
|
||||
@ -329,7 +332,7 @@ local function config_view(display)
|
||||
else
|
||||
tmp_cfg.FacilityTankMode = 0
|
||||
tmp_cfg.FacilityTankDefs = {}
|
||||
main_pane.set_value(3)
|
||||
svr_pane.set_value(7)
|
||||
end
|
||||
end
|
||||
|
||||
@ -563,7 +566,7 @@ local function config_view(display)
|
||||
|
||||
local function submit_mode()
|
||||
tmp_cfg.FacilityTankMode = tank_mode.get_value()
|
||||
main_pane.set_value(3)
|
||||
svr_pane.set_value(7)
|
||||
end
|
||||
|
||||
PushButton{parent=svr_c_5,x=1,y=14,text="\x1b Back",callback=function()svr_pane.set_value(4)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
@ -577,6 +580,23 @@ local function config_view(display)
|
||||
|
||||
PushButton{parent=svr_c_6,x=1,y=14,text="\x1b Back",callback=function()svr_pane.set_value(5)end,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
TextBox{parent=svr_c_7,height=6,text="Charge control provides automatic control to maintain an induction matrix charge level. In order to have smoother control, reactors that were activated will be held on at 0.01 mB/t for a short period before allowing them to turn off. This minimizes overshooting the charge target."}
|
||||
TextBox{parent=svr_c_7,y=8,height=3,text="You can extend this to a full minute to minimize reactors flickering on/off, but there may be more overshoot of the target."}
|
||||
|
||||
local ext_idling = CheckBox{parent=svr_c_7,x=1,y=12,label="Enable Extended Idling",default=ini_cfg.ExtChargeIdling,box_fg_bg=cpair(colors.yellow,colors.black)}
|
||||
|
||||
local function back_from_idling()
|
||||
svr_pane.set_value(util.trinary(tmp_cfg.FacilityTankMode == 0, 3, 5))
|
||||
end
|
||||
|
||||
local function submit_idling()
|
||||
tmp_cfg.ExtChargeIdling = ext_idling.get_value()
|
||||
main_pane.set_value(3)
|
||||
end
|
||||
|
||||
PushButton{parent=svr_c_7,x=1,y=14,text="\x1b Back",callback=back_from_idling,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
PushButton{parent=svr_c_7,x=44,y=14,text="Next \x1a",callback=submit_idling,fg_bg=nav_fg_bg,active_fg_bg=btn_act_fg_bg}
|
||||
|
||||
--#endregion
|
||||
|
||||
--#region Network
|
||||
|
@ -23,7 +23,7 @@ local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
|
||||
local WASTE_MODE = types.WASTE_MODE
|
||||
local WASTE = types.WASTE_PRODUCT
|
||||
|
||||
local IO = rsio.IO
|
||||
local IO = rsio.IO
|
||||
|
||||
local DTV_RTU_S_DATA = qtypes.DTV_RTU_S_DATA
|
||||
|
||||
@ -63,9 +63,9 @@ local facility = {}
|
||||
|
||||
-- create a new facility management object
|
||||
---@nodiscard
|
||||
---@param num_reactors integer number of reactor units
|
||||
---@param config svr_config supervisor configuration
|
||||
---@param cooling_conf sv_cooling_conf cooling configurations of reactor units
|
||||
function facility.new(num_reactors, cooling_conf)
|
||||
function facility.new(config, cooling_conf)
|
||||
local self = {
|
||||
units = {},
|
||||
status_text = { "START UP", "initializing..." },
|
||||
@ -134,8 +134,8 @@ function facility.new(num_reactors, cooling_conf)
|
||||
}
|
||||
|
||||
-- create units
|
||||
for i = 1, num_reactors do
|
||||
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount))
|
||||
for i = 1, config.UnitCount do
|
||||
table.insert(self.units, unit.new(i, cooling_conf.r_cool[i].BoilerCount, cooling_conf.r_cool[i].TurbineCount, config.ExtChargeIdling))
|
||||
table.insert(self.group_map, 0)
|
||||
end
|
||||
|
||||
@ -499,8 +499,10 @@ function facility.new(num_reactors, cooling_conf)
|
||||
|
||||
self.saturated = output ~= out_c
|
||||
|
||||
-- stop idling early if the output is zero, we are at or above the setpoint, and are not losing charge
|
||||
_set_idling(not ((out_c == 0) and (error <= 0) and (avg_outflow <= 0)))
|
||||
if not config.ExtChargeIdling then
|
||||
-- stop idling early if the output is zero, we are at or above the setpoint, and are not losing charge
|
||||
_set_idling(not ((out_c == 0) and (error <= 0) and (avg_outflow <= 0)))
|
||||
end
|
||||
|
||||
-- log.debug(util.sprintf("CHARGE[%f] { CHRG[%f] ERR[%f] INT[%f] => OUT[%f] OUT_C[%f] <= P[%f] I[%f] D[%f] }",
|
||||
-- runtime, avg_charge, error, integral, output, out_c, P, I, D))
|
||||
@ -952,41 +954,41 @@ function facility.new(num_reactors, cooling_conf)
|
||||
function public.auto_stop() self.mode = PROCESS.INACTIVE end
|
||||
|
||||
-- set automatic control configuration and start the process
|
||||
---@param config coord_auto_config configuration
|
||||
---@param auto_cfg coord_auto_config configuration
|
||||
---@return table response ready state (successfully started) and current configuration (after updating)
|
||||
function public.auto_start(config)
|
||||
function public.auto_start(auto_cfg)
|
||||
local charge_scaler = 1000000 -- convert MFE to FE
|
||||
local gen_scaler = 1000 -- convert kFE to FE
|
||||
local ready = false
|
||||
|
||||
-- load up current limits
|
||||
local limits = {}
|
||||
for i = 1, num_reactors do
|
||||
for i = 1, config.UnitCount do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
limits[i] = u.get_control_inf().lim_br100 * 100
|
||||
end
|
||||
|
||||
-- only allow changes if not running
|
||||
if self.mode == PROCESS.INACTIVE then
|
||||
if (type(config.mode) == "number") and (config.mode > PROCESS.INACTIVE) and (config.mode <= PROCESS.GEN_RATE) then
|
||||
self.mode_set = config.mode
|
||||
if (type(auto_cfg.mode) == "number") and (auto_cfg.mode > PROCESS.INACTIVE) and (auto_cfg.mode <= PROCESS.GEN_RATE) then
|
||||
self.mode_set = auto_cfg.mode
|
||||
end
|
||||
|
||||
if (type(config.burn_target) == "number") and config.burn_target >= 0.1 then
|
||||
self.burn_target = config.burn_target
|
||||
if (type(auto_cfg.burn_target) == "number") and auto_cfg.burn_target >= 0.1 then
|
||||
self.burn_target = auto_cfg.burn_target
|
||||
end
|
||||
|
||||
if (type(config.charge_target) == "number") and config.charge_target >= 0 then
|
||||
self.charge_setpoint = config.charge_target * charge_scaler
|
||||
if (type(auto_cfg.charge_target) == "number") and auto_cfg.charge_target >= 0 then
|
||||
self.charge_setpoint = auto_cfg.charge_target * charge_scaler
|
||||
end
|
||||
|
||||
if (type(config.gen_target) == "number") and config.gen_target >= 0 then
|
||||
self.gen_rate_setpoint = config.gen_target * gen_scaler
|
||||
if (type(auto_cfg.gen_target) == "number") and auto_cfg.gen_target >= 0 then
|
||||
self.gen_rate_setpoint = auto_cfg.gen_target * gen_scaler
|
||||
end
|
||||
|
||||
if (type(config.limits) == "table") and (#config.limits == num_reactors) then
|
||||
for i = 1, num_reactors do
|
||||
local limit = config.limits[i]
|
||||
if (type(auto_cfg.limits) == "table") and (#auto_cfg.limits == config.UnitCount) then
|
||||
for i = 1, config.UnitCount do
|
||||
local limit = auto_cfg.limits[i]
|
||||
|
||||
if (type(limit) == "number") and (limit >= 0.1) then
|
||||
limits[i] = limit
|
||||
@ -1026,7 +1028,7 @@ function facility.new(num_reactors, cooling_conf)
|
||||
---@param unit_id integer unit ID
|
||||
---@param group integer group ID or 0 for independent
|
||||
function public.set_group(unit_id, group)
|
||||
if (group >= 0 and group <= 4) and (unit_id > 0 and unit_id <= num_reactors) and self.mode == PROCESS.INACTIVE then
|
||||
if (group >= 0 and group <= 4) and (unit_id > 0 and unit_id <= config.UnitCount) and self.mode == PROCESS.INACTIVE then
|
||||
-- remove from old group if previously assigned
|
||||
local old_group = self.group_map[unit_id]
|
||||
if old_group ~= 0 then
|
||||
|
@ -201,7 +201,7 @@ function svsessions.init(nic, fp_ok, config, cooling_conf)
|
||||
self.nic = nic
|
||||
self.fp_ok = fp_ok
|
||||
self.config = config
|
||||
self.facility = facility.new(config.UnitCount, cooling_conf)
|
||||
self.facility = facility.new(config, cooling_conf)
|
||||
end
|
||||
|
||||
-- find an RTU session by the computer ID
|
||||
|
@ -26,6 +26,7 @@ function supervisor.load_config()
|
||||
config.CoolingConfig = settings.get("CoolingConfig")
|
||||
config.FacilityTankMode = settings.get("FacilityTankMode")
|
||||
config.FacilityTankDefs = settings.get("FacilityTankDefs")
|
||||
config.ExtChargeIdling = settings.get("ExtChargeIdling")
|
||||
|
||||
config.SVR_Channel = settings.get("SVR_Channel")
|
||||
config.PLC_Channel = settings.get("PLC_Channel")
|
||||
@ -58,6 +59,8 @@ function supervisor.load_config()
|
||||
cfv.assert_type_int(config.FacilityTankMode)
|
||||
cfv.assert_range(config.FacilityTankMode, 0, 8)
|
||||
|
||||
cfv.assert_type_bool(config.ExtChargeIdling)
|
||||
|
||||
cfv.assert_channel(config.SVR_Channel)
|
||||
cfv.assert_channel(config.PLC_Channel)
|
||||
cfv.assert_channel(config.RTU_Channel)
|
||||
|
@ -54,8 +54,6 @@ local AISTATE = {
|
||||
|
||||
-- burn rate to idle at
|
||||
local IDLE_RATE = 0.01
|
||||
-- time (ms) to idle
|
||||
local IDLE_TIME = 15000
|
||||
|
||||
---@class reactor_control_unit
|
||||
local unit = {}
|
||||
@ -65,7 +63,11 @@ local unit = {}
|
||||
---@param reactor_id integer reactor unit number
|
||||
---@param num_boilers integer number of boilers expected
|
||||
---@param num_turbines integer number of turbines expected
|
||||
function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
---@param ext_idle boolean extended idling mode
|
||||
function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
-- time (ms) to idle for auto idling
|
||||
local IDLE_TIME = util.trinary(ext_idle, 60000, 10000)
|
||||
|
||||
---@class _unit_self
|
||||
local self = {
|
||||
r_id = reactor_id,
|
||||
@ -543,7 +545,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
if self.auto_engaged and not self.plc_i.is_auto_locked() then self.plc_i.auto_lock(true) end
|
||||
|
||||
-- stop idling when completed
|
||||
if self.auto_idling and ((util.time_ms() - self.auto_idle_start) > IDLE_TIME) then
|
||||
if self.auto_idling and (((util.time_ms() - self.auto_idle_start) > IDLE_TIME) or not self.auto_idle) then
|
||||
log.info(util.c("UNIT ", self.r_id, ": completed idling period"))
|
||||
self.auto_idling = false
|
||||
self.plc_i.auto_set_burn(0, false)
|
||||
@ -601,7 +603,7 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
-- - disabling it will stop the reactor when commanded zero
|
||||
---@param idle boolean true to enable, false to disable (and stop)
|
||||
function public.auto_set_idle(idle)
|
||||
if not (idle and self.auto_idle) then
|
||||
if idle and not self.auto_idle then
|
||||
self.auto_idling = false
|
||||
self.auto_idle_start = 0
|
||||
end
|
||||
|
@ -332,7 +332,7 @@ function logic.update_annunciator(self)
|
||||
-- minimal change indicates the turbine is converging on a flow rate
|
||||
if last.time_tanks < turbine.tanks.last_update then
|
||||
if last.time_tanks > 0 then
|
||||
rotation_stable = math.abs(rotation - last.rotation) < 0.00000004
|
||||
rotation_stable = math.abs(rotation - last.rotation) < 0.00000003
|
||||
end
|
||||
|
||||
last.time_tanks = turbine.tanks.last_update
|
||||
|