removed PLC establish packet handling when already linked
This commit is contained in:
parent
9bb2a99be5
commit
9f3ad3caf0
@ -929,47 +929,7 @@ function plc.comms(id, version, nic, plc_channel, svr_channel, range, reactor, r
|
||||
---@cast packet mgmt_frame
|
||||
-- if linked, only accept packets from configured supervisor
|
||||
if self.linked then
|
||||
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
|
||||
-- link request confirmation
|
||||
if packet.length == 1 then
|
||||
log.debug("received unsolicited establish response")
|
||||
|
||||
local est_ack = packet.data[1]
|
||||
|
||||
if est_ack == ESTABLISH_ACK.ALLOW then
|
||||
self.status_cache = nil
|
||||
_send_struct()
|
||||
public.send_status(plc_state.no_reactor, plc_state.reactor_formed)
|
||||
log.debug("re-sent initial status data due to re-establish")
|
||||
else
|
||||
if est_ack == ESTABLISH_ACK.DENY then
|
||||
println_ts("received unsolicited link denial, unlinking")
|
||||
log.warning("unsolicited establish request denied")
|
||||
elseif est_ack == ESTABLISH_ACK.COLLISION then
|
||||
println_ts("received unsolicited link collision, unlinking")
|
||||
log.warning("unsolicited establish request collision")
|
||||
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
|
||||
println_ts("received unsolicited link version mismatch, unlinking")
|
||||
log.warning("unsolicited establish request version mismatch")
|
||||
else
|
||||
println_ts("invalid unsolicited link response")
|
||||
log.debug("unsolicited unknown establish request response")
|
||||
end
|
||||
|
||||
-- unlink
|
||||
self.sv_addr = comms.BROADCAST
|
||||
self.linked = false
|
||||
end
|
||||
|
||||
-- clear this since this is for something that was unsolicited
|
||||
self.last_est_ack = ESTABLISH_ACK.ALLOW
|
||||
|
||||
-- report link state
|
||||
databus.tx_link_state(est_ack + 1)
|
||||
else
|
||||
log.debug("SCADA_MGMT establish packet length mismatch")
|
||||
end
|
||||
elseif packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
|
||||
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
|
||||
-- keep alive request received, echo back
|
||||
if packet.length == 1 and type(packet.data[1]) == "number" then
|
||||
local timestamp = packet.data[1]
|
||||
|
@ -19,7 +19,7 @@ local plc = require("reactor-plc.plc")
|
||||
local renderer = require("reactor-plc.renderer")
|
||||
local threads = require("reactor-plc.threads")
|
||||
|
||||
local R_PLC_VERSION = "v1.5.1"
|
||||
local R_PLC_VERSION = "v1.5.2"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
|
Loading…