mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2025-07-26 03:22:51 +00:00
#545 supervisor type annotation updates
This commit is contained in:
@ -77,31 +77,31 @@ local tool_ctl = {
|
||||
auth_key_textbox = nil, ---@type graphics_element
|
||||
auth_key_value = "",
|
||||
|
||||
cooling_elems = {},
|
||||
tank_elems = {},
|
||||
cooling_elems = {}, ---@type { line: graphics_element, turbines: graphics_element, boilers: graphics_element, tank: graphics_element }[]
|
||||
tank_elems = {}, ---@type { div: graphics_element, tank_opt: graphics_element, no_tank: graphics_element }[]
|
||||
|
||||
vis_ftanks = {},
|
||||
vis_utanks = {}
|
||||
vis_ftanks = {}, ---@type { line: graphics_element, pipe_conn?: graphics_element, pipe_chain?: graphics_element, pipe_direct?: graphics_element, label?: graphics_element }[]
|
||||
vis_utanks = {} ---@type { line: graphics_element, label: graphics_element }[]
|
||||
}
|
||||
|
||||
---@class svr_config
|
||||
local tmp_cfg = {
|
||||
UnitCount = 1,
|
||||
CoolingConfig = {},
|
||||
CoolingConfig = {}, ---@type { TurbineCount: integer, BoilerCount: integer, TankConnection: boolean }[]
|
||||
FacilityTankMode = 0,
|
||||
FacilityTankDefs = {},
|
||||
FacilityTankDefs = {}, ---@type integer[]
|
||||
ExtChargeIdling = false,
|
||||
SVR_Channel = nil, ---@type integer
|
||||
PLC_Channel = nil, ---@type integer
|
||||
RTU_Channel = nil, ---@type integer
|
||||
CRD_Channel = nil, ---@type integer
|
||||
PKT_Channel = nil, ---@type integer
|
||||
PLC_Timeout = nil, ---@type number
|
||||
RTU_Timeout = nil, ---@type number
|
||||
CRD_Timeout = nil, ---@type number
|
||||
PKT_Timeout = nil, ---@type number
|
||||
TrustedRange = nil, ---@type number
|
||||
AuthKey = nil, ---@type string|nil
|
||||
SVR_Channel = nil, ---@type integer
|
||||
PLC_Channel = nil, ---@type integer
|
||||
RTU_Channel = nil, ---@type integer
|
||||
CRD_Channel = nil, ---@type integer
|
||||
PKT_Channel = nil, ---@type integer
|
||||
PLC_Timeout = nil, ---@type number
|
||||
RTU_Timeout = nil, ---@type number
|
||||
CRD_Timeout = nil, ---@type number
|
||||
PKT_Timeout = nil, ---@type number
|
||||
TrustedRange = nil, ---@type number
|
||||
AuthKey = nil, ---@type string|nil
|
||||
LogMode = 0,
|
||||
LogPath = "",
|
||||
LogDebug = false,
|
||||
@ -294,6 +294,8 @@ local function config_view(display)
|
||||
tmp_cfg.CoolingConfig = {}
|
||||
for i = 1, tmp_cfg.UnitCount do
|
||||
local conf = tool_ctl.cooling_elems[i]
|
||||
-- already verified fields are numbers
|
||||
---@diagnostic disable-next-line: assign-type-mismatch
|
||||
tmp_cfg.CoolingConfig[i] = { TurbineCount = tonumber(conf.turbines.get_value()), BoilerCount = tonumber(conf.boilers.get_value()), TankConnection = conf.tank.get_value() }
|
||||
if conf.tank.get_value() then any_has_tank = true end
|
||||
end
|
||||
|
@ -40,7 +40,7 @@ local facility = {}
|
||||
function facility.new(config)
|
||||
---@class _facility_self
|
||||
local self = {
|
||||
units = {},
|
||||
units = {}, ---@type reactor_unit[]
|
||||
types = { AUTO_SCRAM = AUTO_SCRAM, START_STATUS = START_STATUS },
|
||||
status_text = { "START UP", "initializing..." },
|
||||
all_sys_ok = false,
|
||||
@ -51,16 +51,16 @@ function facility.new(config)
|
||||
r_cool = config.CoolingConfig,
|
||||
fac_tank_mode = config.FacilityTankMode,
|
||||
fac_tank_defs = config.FacilityTankDefs,
|
||||
fac_tank_list = {}
|
||||
fac_tank_list = {} ---@type integer[]
|
||||
},
|
||||
-- rtus
|
||||
rtu_conn_count = 0,
|
||||
rtu_list = {},
|
||||
redstone = {},
|
||||
induction = {},
|
||||
sps = {},
|
||||
tanks = {},
|
||||
envd = {},
|
||||
rtu_list = {}, ---@type unit_session[][]
|
||||
redstone = {}, ---@type unit_session[]
|
||||
induction = {}, ---@type unit_session[]
|
||||
sps = {}, ---@type unit_session[]
|
||||
tanks = {}, ---@type unit_session[]
|
||||
envd = {}, ---@type unit_session[]
|
||||
-- redstone I/O control
|
||||
io_ctl = nil, ---@type rs_controller
|
||||
-- process control
|
||||
@ -105,11 +105,11 @@ function facility.new(config)
|
||||
sps_low_power = false,
|
||||
disabled_sps = false,
|
||||
-- alarm tones
|
||||
tone_states = {},
|
||||
tone_states = {}, ---@type boolean[]
|
||||
test_tone_set = false,
|
||||
test_tone_reset = false,
|
||||
test_tone_states = {},
|
||||
test_alarm_states = {},
|
||||
test_tone_states = {}, ---@type boolean[]
|
||||
test_alarm_states = {}, ---@type boolean[]
|
||||
-- statistics
|
||||
im_stat_init = false,
|
||||
avg_charge = util.mov_avg(3), -- 3 seconds
|
||||
@ -350,7 +350,7 @@ function facility.new(config)
|
||||
-- additionally sets the requested auto waste mode if applicable
|
||||
function public.update_units()
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
local u = self.units[i]
|
||||
u.auto_set_waste(self.current_waste_product)
|
||||
u.update()
|
||||
end
|
||||
@ -363,16 +363,14 @@ function facility.new(config)
|
||||
-- SCRAM all reactor units
|
||||
function public.scram_all()
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
u.scram()
|
||||
self.units[i].scram()
|
||||
end
|
||||
end
|
||||
|
||||
-- ack all alarms on all reactor units
|
||||
function public.ack_all()
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
u.ack_all()
|
||||
local u = self.units[i].ack_all()
|
||||
end
|
||||
end
|
||||
|
||||
@ -393,8 +391,7 @@ function facility.new(config)
|
||||
-- load up current limits
|
||||
local limits = {}
|
||||
for i = 1, config.UnitCount do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
limits[i] = u.get_control_inf().lim_br100 * 100
|
||||
limits[i] = self.units[i].get_control_inf().lim_br100 * 100
|
||||
end
|
||||
|
||||
-- only allow changes if not running
|
||||
@ -565,7 +562,7 @@ function facility.new(config)
|
||||
if all or type == RTU_UNIT_TYPE.IMATRIX then
|
||||
build.induction = {}
|
||||
for i = 1, #self.induction do
|
||||
local matrix = self.induction[i] ---@type unit_session
|
||||
local matrix = self.induction[i]
|
||||
build.induction[i] = { matrix.get_db().formed, matrix.get_db().build }
|
||||
end
|
||||
end
|
||||
@ -573,7 +570,7 @@ function facility.new(config)
|
||||
if all or type == RTU_UNIT_TYPE.SPS then
|
||||
build.sps = {}
|
||||
for i = 1, #self.sps do
|
||||
local sps = self.sps[i] ---@type unit_session
|
||||
local sps = self.sps[i]
|
||||
build.sps[i] = { sps.get_db().formed, sps.get_db().build }
|
||||
end
|
||||
end
|
||||
@ -581,7 +578,7 @@ function facility.new(config)
|
||||
if all or type == RTU_UNIT_TYPE.DYNAMIC_VALVE then
|
||||
build.tanks = {}
|
||||
for i = 1, #self.tanks do
|
||||
local tank = self.tanks[i] ---@type unit_session
|
||||
local tank = self.tanks[i]
|
||||
build.tanks[tank.get_device_idx()] = { tank.get_db().formed, tank.get_db().build }
|
||||
end
|
||||
end
|
||||
@ -649,8 +646,8 @@ function facility.new(config)
|
||||
-- status of induction matricies (including tanks)
|
||||
status.induction = {}
|
||||
for i = 1, #self.induction do
|
||||
local matrix = self.induction[i] ---@type unit_session
|
||||
local db = matrix.get_db() ---@type imatrix_session_db
|
||||
local matrix = self.induction[i]
|
||||
local db = matrix.get_db() ---@type imatrix_session_db
|
||||
|
||||
status.induction[i] = { matrix.is_faulted(), db.formed, db.state, db.tanks }
|
||||
|
||||
@ -662,24 +659,24 @@ function facility.new(config)
|
||||
-- status of sps
|
||||
status.sps = {}
|
||||
for i = 1, #self.sps do
|
||||
local sps = self.sps[i] ---@type unit_session
|
||||
local db = sps.get_db() ---@type sps_session_db
|
||||
local sps = self.sps[i]
|
||||
local db = sps.get_db() ---@type sps_session_db
|
||||
status.sps[i] = { sps.is_faulted(), db.formed, db.state, db.tanks }
|
||||
end
|
||||
|
||||
-- status of dynamic tanks
|
||||
status.tanks = {}
|
||||
for i = 1, #self.tanks do
|
||||
local tank = self.tanks[i] ---@type unit_session
|
||||
local db = tank.get_db() ---@type dynamicv_session_db
|
||||
local tank = self.tanks[i]
|
||||
local db = tank.get_db() ---@type dynamicv_session_db
|
||||
status.tanks[tank.get_device_idx()] = { tank.is_faulted(), db.formed, db.state, db.tanks }
|
||||
end
|
||||
|
||||
-- radiation monitors (environment detectors)
|
||||
status.envds = {}
|
||||
for i = 1, #self.envd do
|
||||
local envd = self.envd[i] ---@type unit_session
|
||||
local db = envd.get_db() ---@type envd_session_db
|
||||
local envd = self.envd[i]
|
||||
local db = envd.get_db() ---@type envd_session_db
|
||||
status.envds[envd.get_device_idx()] = { envd.is_faulted(), db.radiation, db.radiation_raw }
|
||||
end
|
||||
|
||||
|
@ -84,7 +84,7 @@ local function allocate_burn_rate(burn_rate, ramp, abort_on_fault)
|
||||
|
||||
-- go through all reactor units in this group
|
||||
for id = 1, #units do
|
||||
local u = units[id] ---@type reactor_unit
|
||||
local u = units[id]
|
||||
|
||||
local ctl = u.get_control_inf()
|
||||
local lim_br100 = u.auto_get_effective_limit()
|
||||
@ -139,7 +139,7 @@ function update.pre_auto()
|
||||
-- check if test routines are allowed right now
|
||||
self.allow_testing = true
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
local u = self.units[i]
|
||||
self.allow_testing = self.allow_testing and u.is_safe_idle()
|
||||
end
|
||||
|
||||
@ -149,8 +149,8 @@ function update.pre_auto()
|
||||
|
||||
-- calculate moving averages for induction matrix
|
||||
if self.induction[1] ~= nil then
|
||||
local matrix = self.induction[1] ---@type unit_session
|
||||
local db = matrix.get_db() ---@type imatrix_session_db
|
||||
local matrix = self.induction[1]
|
||||
local db = matrix.get_db() ---@type imatrix_session_db
|
||||
|
||||
local build_update = db.build.last_update
|
||||
rate_update = db.state.last_update
|
||||
@ -531,7 +531,7 @@ function update.auto_safety()
|
||||
-- check for critical unit alarms
|
||||
astatus.crit_alarm = false
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
local u = self.units[i]
|
||||
|
||||
if u.has_alarm_min_prio(PRIO.CRITICAL) then
|
||||
astatus.crit_alarm = true
|
||||
@ -544,7 +544,7 @@ function update.auto_safety()
|
||||
local max_rad = 0
|
||||
|
||||
for i = 1, #self.envd do
|
||||
local envd = self.envd[i] ---@type unit_session
|
||||
local envd = self.envd[i]
|
||||
local e_db = envd.get_db() ---@type envd_session_db
|
||||
if e_db.radiation_raw > max_rad then max_rad = e_db.radiation_raw end
|
||||
end
|
||||
@ -620,7 +620,7 @@ function update.auto_safety()
|
||||
|
||||
-- reset PLC RPS trips if we should
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
local u = self.units[i]
|
||||
u.auto_cond_rps_reset()
|
||||
end
|
||||
end
|
||||
@ -647,7 +647,7 @@ function update.alarm_audio()
|
||||
else
|
||||
-- check all alarms for all units
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
local u = self.units[i]
|
||||
for id, alarm in pairs(u.get_alarms()) do
|
||||
alarms[id] = alarms[id] or (alarm == ALARM_STATE.TRIPPED)
|
||||
end
|
||||
@ -730,7 +730,7 @@ function update.redstone(ack_all)
|
||||
-- handle facility SCRAM
|
||||
if self.io_ctl.digital_read(IO.F_SCRAM) then
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
local u = self.units[i]
|
||||
u.cond_scram()
|
||||
end
|
||||
end
|
||||
@ -741,7 +741,7 @@ function update.redstone(ack_all)
|
||||
-- update facility alarm outputs
|
||||
local has_prio_alarm, has_any_alarm = false, false
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
local u = self.units[i]
|
||||
|
||||
if u.has_alarm_min_prio(PRIO.EMERGENCY) then
|
||||
has_prio_alarm, has_any_alarm = true, true
|
||||
@ -771,7 +771,7 @@ function update.unit_mgmt()
|
||||
local need_emcool = false
|
||||
|
||||
for i = 1, #self.units do
|
||||
local u = self.units[i] ---@type reactor_unit
|
||||
local u = self.units[i]
|
||||
|
||||
-- update auto waste processing
|
||||
if u.get_control_inf().waste_mode == WASTE_MODE.AUTO then
|
||||
@ -812,8 +812,8 @@ function update.unit_mgmt()
|
||||
-- there should be no need for any to be in fill only mode
|
||||
if need_emcool then
|
||||
for i = 1, #self.tanks do
|
||||
local session = self.tanks[i] ---@type unit_session
|
||||
local tank = session.get_db() ---@type dynamicv_session_db
|
||||
local session = self.tanks[i]
|
||||
local tank = session.get_db() ---@type dynamicv_session_db
|
||||
|
||||
if tank.state.container_mode == CONTAINER_MODE.FILL then
|
||||
session.get_cmd_queue().push_data(DTV_RTU_S_DATA.SET_CONT_MODE, CONTAINER_MODE.BOTH)
|
||||
|
@ -8,14 +8,19 @@ local util = require("scada-common.util")
|
||||
local pgi = {}
|
||||
|
||||
local data = {
|
||||
rtu_list = nil, ---@type nil|graphics_element
|
||||
pdg_list = nil, ---@type nil|graphics_element
|
||||
chk_list = nil, ---@type nil|graphics_element
|
||||
rtu_entry = nil, ---@type function
|
||||
pdg_entry = nil, ---@type function
|
||||
chk_entry = nil, ---@type function
|
||||
rtu_list = nil, ---@type nil|graphics_element
|
||||
pdg_list = nil, ---@type nil|graphics_element
|
||||
chk_list = nil, ---@type nil|graphics_element
|
||||
rtu_entry = nil, ---@type function
|
||||
pdg_entry = nil, ---@type function
|
||||
chk_entry = nil, ---@type function
|
||||
-- list entries
|
||||
entries = { rtu = {}, pdg = {}, chk = {}, missing = {} }
|
||||
entries = {
|
||||
rtu = {}, ---@type graphics_element[]
|
||||
pdg = {}, ---@type graphics_element[]
|
||||
chk = {}, ---@type graphics_element[][]
|
||||
missing = {} ---@type graphics_element[]
|
||||
}
|
||||
}
|
||||
|
||||
-- link list boxes
|
||||
|
@ -128,7 +128,7 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
|
||||
local unit_builds = {}
|
||||
|
||||
for i = 1, #self.units do
|
||||
local unit = self.units[i] ---@type reactor_unit
|
||||
local unit = self.units[i]
|
||||
unit_builds[unit.get_id()] = unit.get_build()
|
||||
end
|
||||
|
||||
@ -145,7 +145,7 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
|
||||
local builds = {}
|
||||
|
||||
for i = 1, #self.units do
|
||||
local unit = self.units[i] ---@type reactor_unit
|
||||
local unit = self.units[i]
|
||||
builds[unit.get_id()] = unit.get_build()
|
||||
end
|
||||
|
||||
@ -168,7 +168,7 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
|
||||
local status = {}
|
||||
|
||||
for i = 1, #self.units do
|
||||
local unit = self.units[i] ---@type reactor_unit
|
||||
local unit = self.units[i]
|
||||
|
||||
status[unit.get_id()] = {
|
||||
unit.get_reactor_status(),
|
||||
@ -308,7 +308,7 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
|
||||
|
||||
-- continue if valid unit id
|
||||
if util.is_int(uid) and uid > 0 and uid <= #self.units then
|
||||
local unit = self.units[uid] ---@type reactor_unit
|
||||
local unit = self.units[uid]
|
||||
local manual = facility.get_group(uid) == AUTO_GROUP.MANUAL
|
||||
|
||||
if cmd == UNIT_COMMAND.SCRAM then
|
||||
@ -432,8 +432,7 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
|
||||
local unit_id = cmd.val
|
||||
local builds = {}
|
||||
|
||||
local unit = self.units[unit_id] ---@type reactor_unit
|
||||
builds[unit_id] = unit.get_build(-1)
|
||||
builds[unit_id] = self.units[unit_id].get_build(-1)
|
||||
|
||||
_send(CRDN_TYPE.UNIT_BUILDS, { builds })
|
||||
elseif cmd.key == CRD_S_DATA.RESEND_RTU_BUILD then
|
||||
@ -446,8 +445,7 @@ function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, tim
|
||||
|
||||
local builds = {}
|
||||
|
||||
local unit = self.units[unit_id] ---@type reactor_unit
|
||||
builds[unit_id] = unit.get_build(cmd.val.type)
|
||||
builds[unit_id] = self.units[unit_id].get_build(cmd.val.type)
|
||||
|
||||
_send(CRDN_TYPE.UNIT_BUILDS, { builds })
|
||||
else
|
||||
|
@ -63,7 +63,7 @@ function rtu.new_session(id, s_addr, i_seq_num, in_queue, out_queue, timeout, ad
|
||||
keep_alive = 0,
|
||||
alarm_tones = 0
|
||||
},
|
||||
units = {}
|
||||
units = {} ---@type unit_session[]
|
||||
}
|
||||
|
||||
---@class rtu_session
|
||||
@ -80,13 +80,13 @@ function rtu.new_session(id, s_addr, i_seq_num, in_queue, out_queue, timeout, ad
|
||||
_reset_config()
|
||||
|
||||
for i = 1, #self.fac_units do
|
||||
local unit = self.fac_units[i] ---@type reactor_unit
|
||||
local unit = self.fac_units[i]
|
||||
unit.purge_rtu_devices(id)
|
||||
facility.purge_rtu_devices(id)
|
||||
end
|
||||
|
||||
for i = 1, #self.advert do
|
||||
local unit = nil ---@type unit_session|nil
|
||||
local unit = nil
|
||||
|
||||
---@type rtu_advertisement
|
||||
local unit_advert = {
|
||||
@ -96,7 +96,7 @@ function rtu.new_session(id, s_addr, i_seq_num, in_queue, out_queue, timeout, ad
|
||||
rsio = self.advert[i][4]
|
||||
}
|
||||
|
||||
local u_type = unit_advert.type ---@type integer|boolean
|
||||
local u_type = unit_advert.type ---@type RTU_UNIT_TYPE|boolean
|
||||
|
||||
-- validate unit advertisement
|
||||
|
||||
@ -127,7 +127,7 @@ function rtu.new_session(id, s_addr, i_seq_num, in_queue, out_queue, timeout, ad
|
||||
log.debug(log_tag .. "_handle_advertisement(): advertisement unit validation failure")
|
||||
else
|
||||
if unit_advert.reactor > 0 then
|
||||
local target_unit = self.fac_units[unit_advert.reactor] ---@type reactor_unit
|
||||
local target_unit = self.fac_units[unit_advert.reactor]
|
||||
|
||||
-- unit RTUs
|
||||
if u_type == RTU_UNIT_TYPE.REDSTONE then
|
||||
@ -255,8 +255,7 @@ function rtu.new_session(id, s_addr, i_seq_num, in_queue, out_queue, timeout, ad
|
||||
if pkt.scada_frame.protocol() == PROTOCOL.MODBUS_TCP then
|
||||
---@cast pkt modbus_frame
|
||||
if self.units[pkt.unit_id] ~= nil then
|
||||
local unit = self.units[pkt.unit_id] ---@type unit_session
|
||||
unit.handle_packet(pkt)
|
||||
self.units[pkt.unit_id].handle_packet(pkt)
|
||||
end
|
||||
elseif pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
|
||||
---@cast pkt mgmt_frame
|
||||
@ -298,8 +297,7 @@ function rtu.new_session(id, s_addr, i_seq_num, in_queue, out_queue, timeout, ad
|
||||
if pkt.length == 1 then
|
||||
local unit_id = pkt.data[1]
|
||||
if self.units[unit_id] ~= nil then
|
||||
local unit = self.units[unit_id] ---@type unit_session
|
||||
unit.invalidate_cache()
|
||||
self.units[unit_id].invalidate_cache()
|
||||
end
|
||||
else
|
||||
log.debug(log_tag .. "SCADA RTU GW device re-mount packet length mismatch")
|
||||
|
@ -84,7 +84,7 @@ function dynamicv.new(session_id, unit_id, advert, out_queue)
|
||||
},
|
||||
state = {
|
||||
last_update = 0,
|
||||
container_mode = CONTAINER_MODE.BOTH ---@type container_mode
|
||||
container_mode = CONTAINER_MODE.BOTH ---@type container_mode
|
||||
},
|
||||
tanks = {
|
||||
last_update = 0,
|
||||
@ -224,7 +224,7 @@ function dynamicv.new(session_id, unit_id, advert, out_queue)
|
||||
end
|
||||
elseif msg.qtype == mqueue.TYPE.DATA then
|
||||
-- instruction with body
|
||||
local cmd = msg.message ---@type queue_data
|
||||
local cmd = msg.message ---@type queue_data
|
||||
if cmd.key == DTV_RTU_S_DATA.SET_CONT_MODE then
|
||||
if cmd.val == types.CONTAINER_MODE.BOTH or
|
||||
cmd.val == types.CONTAINER_MODE.FILL or
|
||||
|
@ -95,7 +95,7 @@ function turbinev.new(session_id, unit_id, advert, out_queue)
|
||||
flow_rate = 0,
|
||||
prod_rate = 0,
|
||||
steam_input_rate = 0,
|
||||
dumping_mode = DUMPING_MODE.IDLE ---@type dumping_mode
|
||||
dumping_mode = DUMPING_MODE.IDLE ---@type dumping_mode
|
||||
},
|
||||
tanks = {
|
||||
last_update = 0,
|
||||
@ -254,7 +254,7 @@ function turbinev.new(session_id, unit_id, advert, out_queue)
|
||||
end
|
||||
elseif msg.qtype == mqueue.TYPE.DATA then
|
||||
-- instruction with body
|
||||
local cmd = msg.message ---@type queue_data
|
||||
local cmd = msg.message ---@type queue_data
|
||||
if cmd.key == TBV_RTU_S_DATA.SET_DUMP_MODE then
|
||||
if cmd.val == types.DUMPING_MODE.IDLE or
|
||||
cmd.val == types.DUMPING_MODE.DUMPING_EXCESS or
|
||||
|
@ -6,7 +6,8 @@ local util = require("scada-common.util")
|
||||
|
||||
local txnctrl = {}
|
||||
|
||||
local TIMEOUT = 2000 -- 2000ms max wait
|
||||
-- 2000ms max wait
|
||||
local TIMEOUT = 2000
|
||||
|
||||
-- create a new transaction controller
|
||||
---@nodiscard
|
||||
|
@ -164,7 +164,6 @@ function unit_session.new(session_id, unit_id, advert, out_queue, log_tag, txn_t
|
||||
function public.get_cmd_queue() return protected.in_q end
|
||||
|
||||
-- close this unit
|
||||
---@nodiscard
|
||||
function public.close() self.connected = false end
|
||||
-- check if this unit is connected
|
||||
---@nodiscard
|
||||
|
@ -40,13 +40,26 @@ local SESSION_TYPE = {
|
||||
svsessions.SESSION_TYPE = SESSION_TYPE
|
||||
|
||||
local self = {
|
||||
nic = nil, ---@type nic|nil
|
||||
-- references to supervisor state and other data
|
||||
nic = nil, ---@type nic|nil
|
||||
fp_ok = false,
|
||||
config = nil, ---@type svr_config
|
||||
facility = nil, ---@type facility|nil
|
||||
sessions = { rtu = {}, plc = {}, crd = {}, pdg = {} },
|
||||
config = nil, ---@type svr_config
|
||||
facility = nil, ---@type facility|nil
|
||||
-- lists of connected sessions
|
||||
sessions = {
|
||||
rtu = {}, ---@type rtu_session_struct
|
||||
plc = {}, ---@type plc_session_struct
|
||||
crd = {}, ---@type crd_session_struct
|
||||
pdg = {} ---@type pdg_session_struct
|
||||
},
|
||||
-- next session IDs
|
||||
next_ids = { rtu = 0, plc = 0, crd = 0, pdg = 0 },
|
||||
dev_dbg = { duplicate = {}, out_of_range = {}, connected = {} }
|
||||
-- rtu device tracking and invalid assignment detection
|
||||
dev_dbg = {
|
||||
duplicate = {}, ---@type unit_session
|
||||
out_of_range = {}, ---@type unit_session
|
||||
connected = {} ---@type { induction: boolean, sps: boolean, tanks: boolean[], units: unit_connections[] }
|
||||
}
|
||||
}
|
||||
|
||||
---@alias sv_session_structs plc_session_struct|rtu_session_struct|crd_session_struct|pdg_session_struct
|
||||
@ -119,10 +132,10 @@ local function _sv_handle_outq(session)
|
||||
end
|
||||
|
||||
-- iterate all the given sessions
|
||||
---@param sessions table
|
||||
---@param sessions sv_session_structs[]
|
||||
local function _iterate(sessions)
|
||||
for i = 1, #sessions do
|
||||
local session = sessions[i] ---@type sv_session_structs
|
||||
local session = sessions[i]
|
||||
|
||||
if session.open and session.instance.iterate() then
|
||||
_sv_handle_outq(session)
|
||||
@ -150,20 +163,20 @@ local function _shutdown(session)
|
||||
end
|
||||
|
||||
-- close connections
|
||||
---@param sessions table
|
||||
---@param sessions sv_session_structs[]
|
||||
local function _close(sessions)
|
||||
for i = 1, #sessions do
|
||||
local session = sessions[i] ---@type sv_session_structs
|
||||
local session = sessions[i]
|
||||
if session.open then _shutdown(session) end
|
||||
end
|
||||
end
|
||||
|
||||
-- check if a watchdog timer event matches that of one of the provided sessions
|
||||
---@param sessions table
|
||||
---@param sessions sv_session_structs[]
|
||||
---@param timer_event number
|
||||
local function _check_watchdogs(sessions, timer_event)
|
||||
for i = 1, #sessions do
|
||||
local session = sessions[i] ---@type sv_session_structs
|
||||
local session = sessions[i]
|
||||
if session.open then
|
||||
local triggered = session.instance.check_wd(timer_event)
|
||||
if triggered then
|
||||
@ -175,8 +188,9 @@ local function _check_watchdogs(sessions, timer_event)
|
||||
end
|
||||
|
||||
-- delete any closed sessions
|
||||
---@param sessions table
|
||||
---@param sessions sv_session_structs[]
|
||||
local function _free_closed(sessions)
|
||||
---@param session sv_session_structs
|
||||
local f = function (session) return session.open end
|
||||
|
||||
---@param session sv_session_structs
|
||||
@ -189,7 +203,7 @@ end
|
||||
|
||||
-- find a session by computer ID
|
||||
---@nodiscard
|
||||
---@param list table
|
||||
---@param list sv_session_structs[]
|
||||
---@param s_addr integer
|
||||
---@return sv_session_structs|nil
|
||||
local function _find_session(list, s_addr)
|
||||
@ -366,7 +380,7 @@ function svsessions.init(nic, fp_ok, config, facility)
|
||||
|
||||
for i = 1, config.UnitCount do
|
||||
local r_cool = cool_conf.r_cool[i]
|
||||
local conns = { boilers = {}, turbines = {}, tanks = {} }
|
||||
local conns = { boilers = {}, turbines = {}, tanks = {} } ---@type unit_connections
|
||||
|
||||
for b = 1, r_cool.BoilerCount do conns.boilers[b] = true end
|
||||
for t = 1, r_cool.TurbineCount do conns.turbines[t] = true end
|
||||
|
@ -22,7 +22,7 @@ local supervisor = require("supervisor.supervisor")
|
||||
|
||||
local svsessions = require("supervisor.session.svsessions")
|
||||
|
||||
local SUPERVISOR_VERSION = "v1.5.3"
|
||||
local SUPERVISOR_VERSION = "v1.5.4"
|
||||
|
||||
local println = util.println
|
||||
local println_ts = util.println_ts
|
||||
|
@ -81,13 +81,13 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
num_turbines = num_turbines,
|
||||
types = { DT_KEYS = DT_KEYS, AISTATE = AISTATE },
|
||||
-- rtus
|
||||
rtu_list = {},
|
||||
redstone = {},
|
||||
boilers = {},
|
||||
turbines = {},
|
||||
tanks = {},
|
||||
snas = {},
|
||||
envd = {},
|
||||
rtu_list = {}, ---@type unit_session[][]
|
||||
redstone = {}, ---@type unit_session[]
|
||||
boilers = {}, ---@type unit_session[]
|
||||
turbines = {}, ---@type unit_session[]
|
||||
tanks = {}, ---@type unit_session[]
|
||||
snas = {}, ---@type unit_session[]
|
||||
envd = {}, ---@type unit_session[]
|
||||
-- redstone control
|
||||
io_ctl = nil, ---@type rs_controller
|
||||
valves = {}, ---@type unit_valves
|
||||
@ -100,7 +100,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
auto_was_alarmed = false,
|
||||
ramp_target_br100 = 0,
|
||||
-- state tracking
|
||||
deltas = {},
|
||||
deltas = {}, ---@type { last_t: number, last_v: number, dt: number }[]
|
||||
last_heartbeat = 0,
|
||||
last_radiation = 0,
|
||||
damage_decreasing = false,
|
||||
@ -108,12 +108,12 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
damage_start = 0,
|
||||
damage_last = 0,
|
||||
damage_est_last = 0,
|
||||
waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
|
||||
waste_product = WASTE.PLUTONIUM, ---@type WASTE_PRODUCT
|
||||
status_text = { "UNKNOWN", "awaiting connection..." },
|
||||
-- logic for alarms
|
||||
had_reactor = false,
|
||||
turbine_flow_stable = false,
|
||||
turbine_stability_data = {},
|
||||
turbine_stability_data = {}, ---@type { time_state: integer, time_tanks: integer, rotation: number, input_rate: integer }[]
|
||||
last_rate_change_ms = 0,
|
||||
---@type rps_status
|
||||
last_rps_trips = {
|
||||
@ -211,15 +211,15 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
SteamFeedMismatch = false,
|
||||
MaxWaterReturnFeed = false,
|
||||
-- boilers
|
||||
BoilerOnline = {},
|
||||
HeatingRateLow = {},
|
||||
WaterLevelLow = {},
|
||||
BoilerOnline = {}, ---@type boolean[]
|
||||
HeatingRateLow = {}, ---@type boolean[]
|
||||
WaterLevelLow = {}, ---@type boolean[]
|
||||
-- turbines
|
||||
TurbineOnline = {},
|
||||
SteamDumpOpen = {},
|
||||
TurbineOverSpeed = {},
|
||||
GeneratorTrip = {},
|
||||
TurbineTrip = {}
|
||||
TurbineOnline = {}, ---@type boolean[]
|
||||
SteamDumpOpen = {}, ---@type integer[]
|
||||
TurbineOverSpeed = {}, ---@type boolean[]
|
||||
GeneratorTrip = {}, ---@type boolean[]
|
||||
TurbineTrip = {} ---@type boolean[]
|
||||
},
|
||||
---@class alarms
|
||||
alarm_states = {
|
||||
@ -244,7 +244,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
blade_count = 0,
|
||||
br100 = 0,
|
||||
lim_br100 = 0,
|
||||
waste_mode = WASTE_MODE.AUTO ---@type WASTE_MODE
|
||||
waste_mode = WASTE_MODE.AUTO ---@type WASTE_MODE
|
||||
}
|
||||
}
|
||||
}
|
||||
@ -324,8 +324,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
end
|
||||
|
||||
for i = 1, #self.boilers do
|
||||
local boiler = self.boilers[i] ---@type unit_session
|
||||
local db = boiler.get_db() ---@type boilerv_session_db
|
||||
local boiler = self.boilers[i]
|
||||
local db = boiler.get_db() ---@type boilerv_session_db
|
||||
|
||||
local last_update_s = db.tanks.last_update / 1000.0
|
||||
|
||||
@ -336,8 +336,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
end
|
||||
|
||||
for i = 1, #self.turbines do
|
||||
local turbine = self.turbines[i] ---@type unit_session
|
||||
local db = turbine.get_db() ---@type turbinev_session_db
|
||||
local turbine = self.turbines[i]
|
||||
local db = turbine.get_db() ---@type turbinev_session_db
|
||||
|
||||
local last_update_s = db.tanks.last_update / 1000.0
|
||||
|
||||
@ -553,8 +553,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
|
||||
-- check boilers formed/faulted
|
||||
for i = 1, #self.boilers do
|
||||
local sess = self.boilers[i] ---@type unit_session
|
||||
local boiler = sess.get_db() ---@type boilerv_session_db
|
||||
local sess = self.boilers[i]
|
||||
local boiler = sess.get_db() ---@type boilerv_session_db
|
||||
if sess.is_faulted() or not boiler.formed then
|
||||
self.db.control.degraded = true
|
||||
end
|
||||
@ -562,8 +562,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
|
||||
-- check turbines formed/faulted
|
||||
for i = 1, #self.turbines do
|
||||
local sess = self.turbines[i] ---@type unit_session
|
||||
local turbine = sess.get_db() ---@type turbinev_session_db
|
||||
local sess = self.turbines[i]
|
||||
local turbine = sess.get_db() ---@type turbinev_session_db
|
||||
if sess.is_faulted() or not turbine.formed then
|
||||
self.db.control.degraded = true
|
||||
end
|
||||
@ -881,7 +881,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
if all or (filter == RTU_UNIT_TYPE.BOILER_VALVE) then
|
||||
build.boilers = {}
|
||||
for i = 1, #self.boilers do
|
||||
local boiler = self.boilers[i] ---@type unit_session
|
||||
local boiler = self.boilers[i]
|
||||
build.boilers[boiler.get_device_idx()] = { boiler.get_db().formed, boiler.get_db().build }
|
||||
end
|
||||
end
|
||||
@ -889,7 +889,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
if all or (filter == RTU_UNIT_TYPE.TURBINE_VALVE) then
|
||||
build.turbines = {}
|
||||
for i = 1, #self.turbines do
|
||||
local turbine = self.turbines[i] ---@type unit_session
|
||||
local turbine = self.turbines[i]
|
||||
build.turbines[turbine.get_device_idx()] = { turbine.get_db().formed, turbine.get_db().build }
|
||||
end
|
||||
end
|
||||
@ -897,7 +897,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
if all or (filter == RTU_UNIT_TYPE.DYNAMIC_VALVE) then
|
||||
build.tanks = {}
|
||||
for i = 1, #self.tanks do
|
||||
local tank = self.tanks[i] ---@type unit_session
|
||||
local tank = self.tanks[i]
|
||||
build.tanks[tank.get_device_idx()] = { tank.get_db().formed, tank.get_db().build }
|
||||
end
|
||||
end
|
||||
@ -927,19 +927,20 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
-- check which RTUs are connected
|
||||
---@nodiscard
|
||||
function public.check_rtu_conns()
|
||||
---@class unit_connections
|
||||
local conns = {}
|
||||
|
||||
conns.boilers = {}
|
||||
conns.boilers = {} ---@type boolean[]
|
||||
for i = 1, #self.boilers do
|
||||
conns.boilers[self.boilers[i].get_device_idx()] = true
|
||||
end
|
||||
|
||||
conns.turbines = {}
|
||||
conns.turbines = {} ---@type boolean[]
|
||||
for i = 1, #self.turbines do
|
||||
conns.turbines[self.turbines[i].get_device_idx()] = true
|
||||
end
|
||||
|
||||
conns.tanks = {}
|
||||
conns.tanks = {} ---@type boolean[]
|
||||
for i = 1, #self.tanks do
|
||||
conns.tanks[self.tanks[i].get_device_idx()] = true
|
||||
end
|
||||
@ -955,31 +956,31 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
-- status of boilers (including tanks)
|
||||
status.boilers = {}
|
||||
for i = 1, #self.boilers do
|
||||
local boiler = self.boilers[i] ---@type unit_session
|
||||
local db = boiler.get_db() ---@type boilerv_session_db
|
||||
local boiler = self.boilers[i]
|
||||
local db = boiler.get_db() ---@type boilerv_session_db
|
||||
status.boilers[boiler.get_device_idx()] = { boiler.is_faulted(), db.formed, db.state, db.tanks }
|
||||
end
|
||||
|
||||
-- status of turbines (including tanks)
|
||||
status.turbines = {}
|
||||
for i = 1, #self.turbines do
|
||||
local turbine = self.turbines[i] ---@type unit_session
|
||||
local db = turbine.get_db() ---@type turbinev_session_db
|
||||
local turbine = self.turbines[i]
|
||||
local db = turbine.get_db() ---@type turbinev_session_db
|
||||
status.turbines[turbine.get_device_idx()] = { turbine.is_faulted(), db.formed, db.state, db.tanks }
|
||||
end
|
||||
|
||||
-- status of dynamic tanks
|
||||
status.tanks = {}
|
||||
for i = 1, #self.tanks do
|
||||
local tank = self.tanks[i] ---@type unit_session
|
||||
local db = tank.get_db() ---@type dynamicv_session_db
|
||||
local tank = self.tanks[i]
|
||||
local db = tank.get_db() ---@type dynamicv_session_db
|
||||
status.tanks[tank.get_device_idx()] = { tank.is_faulted(), db.formed, db.state, db.tanks }
|
||||
end
|
||||
|
||||
-- SNA statistical information
|
||||
local total_peak, total_avail, total_out = 0, 0, 0
|
||||
for i = 1, #self.snas do
|
||||
local db = self.snas[i].get_db() ---@type sna_session_db
|
||||
local db = self.snas[i].get_db() ---@type sna_session_db
|
||||
total_peak = total_peak + db.state.peak_production
|
||||
total_avail = total_avail + db.state.production_rate
|
||||
total_out = total_out + math.min(db.tanks.input.amount / 10, db.state.production_rate)
|
||||
@ -989,8 +990,8 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
-- radiation monitors (environment detectors)
|
||||
status.envds = {}
|
||||
for i = 1, #self.envd do
|
||||
local envd = self.envd[i] ---@type unit_session
|
||||
local db = envd.get_db() ---@type envd_session_db
|
||||
local envd = self.envd[i]
|
||||
local db = envd.get_db() ---@type envd_session_db
|
||||
status.envds[envd.get_device_idx()] = { envd.is_faulted(), db.radiation, db.radiation_raw }
|
||||
end
|
||||
|
||||
@ -1004,7 +1005,7 @@ function unit.new(reactor_id, num_boilers, num_turbines, ext_idle)
|
||||
local total_avail_rate = 0
|
||||
|
||||
for i = 1, #self.snas do
|
||||
local db = self.snas[i].get_db() ---@type sna_session_db
|
||||
local db = self.snas[i].get_db() ---@type sna_session_db
|
||||
total_avail_rate = total_avail_rate + db.state.production_rate
|
||||
end
|
||||
|
||||
|
@ -161,8 +161,8 @@ function logic.update_annunciator(self)
|
||||
local max_rad, any_faulted = 0, false
|
||||
|
||||
for i = 1, #self.envd do
|
||||
local envd = self.envd[i] ---@type unit_session
|
||||
local db = envd.get_db() ---@type envd_session_db
|
||||
local envd = self.envd[i]
|
||||
local db = envd.get_db() ---@type envd_session_db
|
||||
any_faulted = any_faulted or envd.is_faulted()
|
||||
if db.radiation_raw > max_rad then max_rad = db.radiation_raw end
|
||||
end
|
||||
@ -197,7 +197,7 @@ function logic.update_annunciator(self)
|
||||
if num_boilers > 0 then
|
||||
-- go through boilers for stats and online
|
||||
for i = 1, #self.boilers do
|
||||
local session = self.boilers[i] ---@type unit_session
|
||||
local session = self.boilers[i]
|
||||
local boiler = session.get_db() ---@type boilerv_session_db
|
||||
local idx = session.get_device_idx()
|
||||
|
||||
@ -225,9 +225,9 @@ function logic.update_annunciator(self)
|
||||
|
||||
-- check for inactive boilers while reactor is active
|
||||
for i = 1, #self.boilers do
|
||||
local boiler = self.boilers[i] ---@type unit_session
|
||||
local boiler = self.boilers[i]
|
||||
local idx = boiler.get_device_idx()
|
||||
local db = boiler.get_db() ---@type boilerv_session_db
|
||||
local db = boiler.get_db() ---@type boilerv_session_db
|
||||
|
||||
if r_db.mek_status.status then
|
||||
annunc.HeatingRateLow[idx] = db.state.boil_rate == 0
|
||||
@ -250,9 +250,9 @@ function logic.update_annunciator(self)
|
||||
|
||||
if num_boilers > 0 then
|
||||
for i = 1, #self.boilers do
|
||||
local boiler = self.boilers[i] ---@type unit_session
|
||||
local boiler = self.boilers[i]
|
||||
local idx = boiler.get_device_idx()
|
||||
local db = boiler.get_db() ---@type boilerv_session_db
|
||||
local db = boiler.get_db() ---@type boilerv_session_db
|
||||
|
||||
local gaining_hc = _get_dt(DT_KEYS.BoilerHCool .. idx) > 10.0 or db.tanks.hcool_fill == 1
|
||||
|
||||
@ -294,7 +294,7 @@ function logic.update_annunciator(self)
|
||||
|
||||
-- go through turbines for stats and online
|
||||
for i = 1, #self.turbines do
|
||||
local session = self.turbines[i] ---@type unit_session
|
||||
local session = self.turbines[i]
|
||||
local turbine = session.get_db() ---@type turbinev_session_db
|
||||
local idx = session.get_device_idx()
|
||||
|
||||
@ -380,8 +380,8 @@ function logic.update_annunciator(self)
|
||||
|
||||
-- turbine safety checks
|
||||
for i = 1, #self.turbines do
|
||||
local turbine = self.turbines[i] ---@type unit_session
|
||||
local db = turbine.get_db() ---@type turbinev_session_db
|
||||
local turbine = self.turbines[i]
|
||||
local db = turbine.get_db() ---@type turbinev_session_db
|
||||
local idx = turbine.get_device_idx()
|
||||
|
||||
-- check if steam dumps are open
|
||||
@ -904,8 +904,8 @@ function logic.handle_redstone(self)
|
||||
if not cache.rps_trip then
|
||||
-- set turbines to not dump steam
|
||||
for i = 1, #self.turbines do
|
||||
local session = self.turbines[i] ---@type unit_session
|
||||
local turbine = session.get_db() ---@type turbinev_session_db
|
||||
local session = self.turbines[i]
|
||||
local turbine = session.get_db() ---@type turbinev_session_db
|
||||
|
||||
if turbine.state.dumping_mode ~= DUMPING_MODE.IDLE then
|
||||
session.get_cmd_queue().push_data(TBV_RTU_S_DATA.SET_DUMP_MODE, DUMPING_MODE.IDLE)
|
||||
@ -921,8 +921,8 @@ function logic.handle_redstone(self)
|
||||
elseif enable_emer_cool or self.emcool_opened then
|
||||
-- set turbines to dump excess steam
|
||||
for i = 1, #self.turbines do
|
||||
local session = self.turbines[i] ---@type unit_session
|
||||
local turbine = session.get_db() ---@type turbinev_session_db
|
||||
local session = self.turbines[i]
|
||||
local turbine = session.get_db() ---@type turbinev_session_db
|
||||
|
||||
if turbine.state.dumping_mode ~= DUMPING_MODE.DUMPING_EXCESS then
|
||||
session.get_cmd_queue().push_data(TBV_RTU_S_DATA.SET_DUMP_MODE, DUMPING_MODE.DUMPING_EXCESS)
|
||||
@ -931,8 +931,8 @@ function logic.handle_redstone(self)
|
||||
|
||||
-- make sure dynamic tanks are allowing outflow
|
||||
for i = 1, #self.tanks do
|
||||
local session = self.tanks[i] ---@type unit_session
|
||||
local tank = session.get_db() ---@type dynamicv_session_db
|
||||
local session = self.tanks[i]
|
||||
local tank = session.get_db() ---@type dynamicv_session_db
|
||||
|
||||
if tank.state.container_mode == CONTAINER_MODE.FILL then
|
||||
session.get_cmd_queue().push_data(DTV_RTU_S_DATA.SET_CONT_MODE, CONTAINER_MODE.BOTH)
|
||||
|
Reference in New Issue