@ -25,7 +25,7 @@ local println_ts = util.println_ts
|
||||
local PCALL_SCRAM_MSG = "pcall: Scram requires the reactor to be active."
|
||||
local PCALL_START_MSG = "pcall: Reactor is already active."
|
||||
|
||||
-- RPS SAFETY CONSTANTS
|
||||
--#region RPS SAFETY CONSTANTS
|
||||
|
||||
local MAX_DAMAGE_PERCENT = 90
|
||||
local MAX_DAMAGE_TEMPERATURE = 1200
|
||||
@ -33,13 +33,12 @@ local MIN_COOLANT_FILL = 0.10
|
||||
local MAX_WASTE_FILL = 0.8
|
||||
local MAX_HEATED_COLLANT_FILL = 0.95
|
||||
|
||||
-- END RPS SAFETY CONSTANTS
|
||||
--#endregion END RPS SAFETY CONSTANTS
|
||||
|
||||
--- RPS: Reactor Protection System
|
||||
---
|
||||
--- identifies dangerous states and SCRAMs reactor if warranted
|
||||
---
|
||||
--- autonomous from main SCADA supervisor/coordinator control
|
||||
-- RPS: Reactor Protection System<br>
|
||||
-- identifies dangerous states and SCRAMs reactor if warranted<br>
|
||||
-- autonomous from main SCADA supervisor/coordinator control
|
||||
---@nodiscard
|
||||
---@param reactor table
|
||||
---@param is_formed boolean
|
||||
function plc.rps_init(reactor, is_formed)
|
||||
@ -270,6 +269,7 @@ function plc.rps_init(reactor, is_formed)
|
||||
end
|
||||
|
||||
-- check all safety conditions
|
||||
---@nodiscard
|
||||
---@return boolean tripped, rps_trip_cause trip_status, boolean first_trip
|
||||
function public.check()
|
||||
local status = RPS_TRIP_CAUSE.OK
|
||||
@ -359,16 +359,23 @@ function plc.rps_init(reactor, is_formed)
|
||||
return self.tripped, status, first_trip
|
||||
end
|
||||
|
||||
---@nodiscard
|
||||
function public.status() return self.state end
|
||||
|
||||
---@nodiscard
|
||||
function public.is_tripped() return self.tripped end
|
||||
---@nodiscard
|
||||
function public.get_trip_cause() return self.trip_cause end
|
||||
|
||||
---@nodiscard
|
||||
function public.is_active() return self.reactor_enabled end
|
||||
---@nodiscard
|
||||
function public.is_formed() return self.formed end
|
||||
---@nodiscard
|
||||
function public.is_force_disabled() return self.force_disabled end
|
||||
|
||||
-- get the runtime of the reactor if active, or the last runtime if disabled
|
||||
---@nodiscard
|
||||
---@return integer runtime time since last enable
|
||||
function public.get_runtime() return util.trinary(self.reactor_enabled, util.time_ms() - self.enabled_at, self.last_runtime) end
|
||||
|
||||
@ -402,6 +409,7 @@ function plc.rps_init(reactor, is_formed)
|
||||
end
|
||||
|
||||
-- Reactor PLC Communications
|
||||
---@nodiscard
|
||||
---@param id integer reactor ID
|
||||
---@param version string PLC version
|
||||
---@param modem table modem device
|
||||
@ -416,8 +424,6 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
seq_num = 0,
|
||||
r_seq_num = nil,
|
||||
modem = modem,
|
||||
s_port = server_port,
|
||||
l_port = local_port,
|
||||
reactor = reactor,
|
||||
scrammed = false,
|
||||
linked = false,
|
||||
@ -428,9 +434,6 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
max_burn_rate = nil
|
||||
}
|
||||
|
||||
---@class plc_comms
|
||||
local public = {}
|
||||
|
||||
comms.set_trusted_range(range)
|
||||
|
||||
-- PRIVATE FUNCTIONS --
|
||||
@ -438,7 +441,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
-- configure modem channels
|
||||
local function _conf_channels()
|
||||
self.modem.closeAll()
|
||||
self.modem.open(self.l_port)
|
||||
self.modem.open(local_port)
|
||||
end
|
||||
|
||||
_conf_channels()
|
||||
@ -453,7 +456,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
r_pkt.make(id, msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOL.RPLC, r_pkt.raw_sendable())
|
||||
|
||||
self.modem.transmit(self.s_port, self.l_port, s_pkt.raw_sendable())
|
||||
self.modem.transmit(server_port, local_port, s_pkt.raw_sendable())
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
@ -467,7 +470,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
m_pkt.make(msg_type, msg)
|
||||
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
||||
|
||||
self.modem.transmit(self.s_port, self.l_port, s_pkt.raw_sendable())
|
||||
self.modem.transmit(server_port, local_port, s_pkt.raw_sendable())
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
@ -614,6 +617,9 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
|
||||
-- PUBLIC FUNCTIONS --
|
||||
|
||||
---@class plc_comms
|
||||
local public = {}
|
||||
|
||||
-- reconnect a newly connected modem
|
||||
---@param modem table
|
||||
---@diagnostic disable-next-line: redefined-local
|
||||
@ -679,9 +685,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
|
||||
_send(RPLC_TYPE.STATUS, sys_status)
|
||||
|
||||
if self.resend_build then
|
||||
_send_struct()
|
||||
end
|
||||
if self.resend_build then _send_struct() end
|
||||
end
|
||||
end
|
||||
|
||||
@ -696,12 +700,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
---@param cause rps_trip_cause reactor protection system status
|
||||
function public.send_rps_alarm(cause)
|
||||
if self.linked then
|
||||
local rps_alarm = {
|
||||
cause,
|
||||
table.unpack(rps.status())
|
||||
}
|
||||
|
||||
_send(RPLC_TYPE.RPS_ALARM, rps_alarm)
|
||||
_send(RPLC_TYPE.RPS_ALARM, { cause, table.unpack(rps.status()) })
|
||||
end
|
||||
end
|
||||
|
||||
@ -745,7 +744,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
---@param plc_state plc_state PLC state
|
||||
---@param setpoints setpoints setpoint control table
|
||||
function public.handle_packet(packet, plc_state, setpoints)
|
||||
if packet ~= nil and packet.scada_frame.local_port() == self.l_port then
|
||||
if packet.scada_frame.local_port() == local_port then
|
||||
-- check sequence number
|
||||
if self.r_seq_num == nil then
|
||||
self.r_seq_num = packet.scada_frame.seq_num()
|
||||
@ -848,9 +847,8 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
log.debug("AUTO: stopping the reactor to meet 0.0 burn rate")
|
||||
if rps.scram() then
|
||||
ack = AUTO_ACK.ZERO_DIS_OK
|
||||
self.auto_last_disable = util.time_ms()
|
||||
else
|
||||
log.debug("AUTO: automatic reactor stop failed")
|
||||
log.warning("AUTO: automatic reactor stop failed")
|
||||
end
|
||||
else
|
||||
ack = AUTO_ACK.ZERO_DIS_OK
|
||||
@ -862,10 +860,10 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
|
||||
self.reactor.setBurnRate(0.01)
|
||||
if self.reactor.__p_is_faulted() then
|
||||
log.debug("AUTO: failed to reset burn rate for auto activation")
|
||||
log.warning("AUTO: failed to reset burn rate for auto activation")
|
||||
else
|
||||
if not rps.auto_activate() then
|
||||
log.debug("AUTO: automatic reactor activation failed")
|
||||
log.warning("AUTO: automatic reactor activation failed")
|
||||
end
|
||||
end
|
||||
end
|
||||
@ -965,7 +963,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
|
||||
if est_ack == ESTABLISH_ACK.ALLOW then
|
||||
println_ts("linked!")
|
||||
log.debug("supervisor establish request approved")
|
||||
log.info("supervisor establish request approved, PLC is linked")
|
||||
|
||||
-- reset remote sequence number and cache
|
||||
self.r_seq_num = nil
|
||||
@ -978,16 +976,16 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
elseif self.last_est_ack ~= est_ack then
|
||||
if est_ack == ESTABLISH_ACK.DENY then
|
||||
println_ts("link request denied, retrying...")
|
||||
log.debug("establish request denied")
|
||||
log.info("supervisor establish request denied, retrying")
|
||||
elseif est_ack == ESTABLISH_ACK.COLLISION then
|
||||
println_ts("reactor PLC ID collision (check config), retrying...")
|
||||
log.warning("establish request collision")
|
||||
log.warning("establish request collision, retrying")
|
||||
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
|
||||
println_ts("supervisor version mismatch (try updating), retrying...")
|
||||
log.warning("establish request version mismatch")
|
||||
log.warning("establish request version mismatch, retrying")
|
||||
else
|
||||
println_ts("invalid link response, bad channel? retrying...")
|
||||
log.error("unknown establish request response")
|
||||
log.error("unknown establish request response, retrying")
|
||||
end
|
||||
end
|
||||
|
||||
@ -1006,7 +1004,9 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
|
||||
end
|
||||
end
|
||||
|
||||
---@nodiscard
|
||||
function public.is_scrammed() return self.scrammed end
|
||||
---@nodiscard
|
||||
function public.is_linked() return self.linked end
|
||||
|
||||
return public
|
||||
|
@ -145,8 +145,7 @@ local function main()
|
||||
plc_state.no_modem = true
|
||||
end
|
||||
|
||||
-- PLC init
|
||||
---
|
||||
-- PLC init<br>
|
||||
--- EVENT_CONSUMER: this function consumes events
|
||||
local function init()
|
||||
if plc_state.init_ok then
|
||||
@ -170,13 +169,13 @@ local function main()
|
||||
log.debug("init> comms init")
|
||||
else
|
||||
println("boot> starting in offline mode")
|
||||
log.debug("init> running without networking")
|
||||
log.info("init> running without networking")
|
||||
end
|
||||
|
||||
util.push_event("clock_start")
|
||||
|
||||
println("boot> completed")
|
||||
log.debug("init> boot completed")
|
||||
log.info("init> boot completed")
|
||||
else
|
||||
println("boot> system in degraded state, awaiting devices...")
|
||||
log.warning("init> booted in a degraded state, awaiting peripheral connections...")
|
||||
|
@ -28,6 +28,7 @@ local MQ__COMM_CMD = {
|
||||
}
|
||||
|
||||
-- main thread
|
||||
---@nodiscard
|
||||
---@param smem plc_shared_memory
|
||||
---@param init function
|
||||
function threads.thread__main(smem, init)
|
||||
@ -45,9 +46,9 @@ function threads.thread__main(smem, init)
|
||||
local loop_clock = util.new_clock(MAIN_CLOCK)
|
||||
|
||||
-- load in from shared memory
|
||||
local networked = smem.networked
|
||||
local plc_state = smem.plc_state
|
||||
local plc_dev = smem.plc_dev
|
||||
local networked = smem.networked
|
||||
local plc_state = smem.plc_state
|
||||
local plc_dev = smem.plc_dev
|
||||
|
||||
-- event loop
|
||||
while true do
|
||||
@ -276,6 +277,7 @@ function threads.thread__main(smem, init)
|
||||
end
|
||||
|
||||
-- RPS operation thread
|
||||
---@nodiscard
|
||||
---@param smem plc_shared_memory
|
||||
function threads.thread__rps(smem)
|
||||
---@class parallel_thread
|
||||
@ -298,10 +300,10 @@ function threads.thread__rps(smem)
|
||||
-- thread loop
|
||||
while true do
|
||||
-- get plc_sys fields (may have been set late due to degraded boot)
|
||||
local rps = smem.plc_sys.rps
|
||||
local plc_comms = smem.plc_sys.plc_comms
|
||||
local rps = smem.plc_sys.rps
|
||||
local plc_comms = smem.plc_sys.plc_comms
|
||||
-- get reactor, may have changed do to disconnect/reconnect
|
||||
local reactor = plc_dev.reactor
|
||||
local reactor = plc_dev.reactor
|
||||
|
||||
-- RPS checks
|
||||
if plc_state.init_ok then
|
||||
@ -416,6 +418,7 @@ function threads.thread__rps(smem)
|
||||
end
|
||||
|
||||
-- communications sender thread
|
||||
---@nodiscard
|
||||
---@param smem plc_shared_memory
|
||||
function threads.thread__comms_tx(smem)
|
||||
---@class parallel_thread
|
||||
@ -491,6 +494,7 @@ function threads.thread__comms_tx(smem)
|
||||
end
|
||||
|
||||
-- communications handler thread
|
||||
---@nodiscard
|
||||
---@param smem plc_shared_memory
|
||||
function threads.thread__comms_rx(smem)
|
||||
---@class parallel_thread
|
||||
@ -565,7 +569,8 @@ function threads.thread__comms_rx(smem)
|
||||
return public
|
||||
end
|
||||
|
||||
-- apply setpoints
|
||||
-- ramp control outputs to desired setpoints
|
||||
---@nodiscard
|
||||
---@param smem plc_shared_memory
|
||||
function threads.thread__setpoint_control(smem)
|
||||
---@class parallel_thread
|
||||
|
@ -334,7 +334,7 @@ function comms.rplc_packet()
|
||||
frame = nil,
|
||||
raw = {},
|
||||
id = 0,
|
||||
type = -1,
|
||||
type = 0, ---@type RPLC_TYPE
|
||||
length = 0,
|
||||
data = {}
|
||||
}
|
||||
@ -436,7 +436,7 @@ function comms.mgmt_packet()
|
||||
local self = {
|
||||
frame = nil,
|
||||
raw = {},
|
||||
type = -1,
|
||||
type = 0, ---@type SCADA_MGMT_TYPE
|
||||
length = 0,
|
||||
data = {}
|
||||
}
|
||||
@ -528,7 +528,7 @@ function comms.crdn_packet()
|
||||
local self = {
|
||||
frame = nil,
|
||||
raw = {},
|
||||
type = -1,
|
||||
type = 0, ---@type SCADA_CRDN_TYPE
|
||||
length = 0,
|
||||
data = {}
|
||||
}
|
||||
@ -617,13 +617,13 @@ function comms.crdn_packet()
|
||||
end
|
||||
|
||||
-- coordinator API (CAPI) packet
|
||||
---@todo implement for pocket access
|
||||
---@todo implement for pocket access, set enum type for self.type
|
||||
---@nodiscard
|
||||
function comms.capi_packet()
|
||||
local self = {
|
||||
frame = nil,
|
||||
raw = {},
|
||||
type = -1,
|
||||
type = 0,
|
||||
length = 0,
|
||||
data = {}
|
||||
}
|
||||
|
Loading…
Reference in New Issue