@ -51,8 +51,8 @@ local SCADA_MGMT_TYPES = {
|
||||
---@alias SCADA_CRDN_TYPES integer
|
||||
local SCADA_CRDN_TYPES = {
|
||||
ESTABLISH = 0, -- initial greeting
|
||||
QUERY_UNIT = 1, -- query the state of a unit
|
||||
QUERY_FACILITY = 2, -- query general facility status
|
||||
STRUCT_BUILDS = 1, -- mekanism structure builds
|
||||
UNIT_STATUSES = 2, -- state of reactor units
|
||||
COMMAND_UNIT = 3, -- command a reactor unit
|
||||
ALARM = 4 -- alarm signaling
|
||||
}
|
||||
@ -453,8 +453,8 @@ function comms.crdn_packet()
|
||||
-- check that type is known
|
||||
local function _crdn_type_valid()
|
||||
return self.type == SCADA_CRDN_TYPES.ESTABLISH or
|
||||
self.type == SCADA_CRDN_TYPES.QUERY_UNIT or
|
||||
self.type == SCADA_CRDN_TYPES.QUERY_FACILITY or
|
||||
self.type == SCADA_CRDN_TYPES.STRUCT_BUILDS or
|
||||
self.type == SCADA_CRDN_TYPES.UNIT_STATUSES or
|
||||
self.type == SCADA_CRDN_TYPES.COMMAND_UNIT or
|
||||
self.type == SCADA_CRDN_TYPES.ALARM
|
||||
end
|
||||
|
@ -14,8 +14,13 @@ local println = util.println
|
||||
local print_ts = util.print_ts
|
||||
local println_ts = util.println_ts
|
||||
|
||||
-- retry time constants in ms
|
||||
local INITIAL_WAIT = 1500
|
||||
local RETRY_PERIOD = 1000
|
||||
|
||||
local PERIODICS = {
|
||||
KEEP_ALIVE = 2000
|
||||
KEEP_ALIVE = 2000,
|
||||
STATUS = 500
|
||||
}
|
||||
|
||||
-- coordinator supervisor session
|
||||
@ -40,7 +45,16 @@ function coordinator.new_session(id, in_queue, out_queue, facility_units)
|
||||
-- periodic messages
|
||||
periodics = {
|
||||
last_update = 0,
|
||||
keep_alive = 0
|
||||
keep_alive = 0,
|
||||
status_packet = 0
|
||||
},
|
||||
-- when to next retry one of these messages
|
||||
retry_times = {
|
||||
builds_packet = (util.time() + 500)
|
||||
},
|
||||
-- message acknowledgements
|
||||
acks = {
|
||||
builds = true
|
||||
}
|
||||
}
|
||||
|
||||
@ -78,6 +92,34 @@ function coordinator.new_session(id, in_queue, out_queue, facility_units)
|
||||
self.seq_num = self.seq_num + 1
|
||||
end
|
||||
|
||||
-- send unit builds
|
||||
local function _send_builds()
|
||||
self.acks.builds = false
|
||||
|
||||
local builds = {}
|
||||
|
||||
for i = 1, #self.units do
|
||||
local unit = self.units[i] ---@type reactor_unit
|
||||
builds[unit.get_id()] = unit.get_build()
|
||||
end
|
||||
|
||||
_send(SCADA_CRDN_TYPES.STRUCT_BUILDS, builds)
|
||||
end
|
||||
|
||||
-- send unit statuses
|
||||
local function _send_status()
|
||||
self.acks.builds = false
|
||||
|
||||
local status = {}
|
||||
|
||||
for i = 1, #self.units do
|
||||
local unit = self.units[i] ---@type reactor_unit
|
||||
status[unit.get_id()] = { unit.get_reactor_status(), unit.get_rtu_statuses() }
|
||||
end
|
||||
|
||||
_send(SCADA_CRDN_TYPES.UNIT_STATUSES, status)
|
||||
end
|
||||
|
||||
-- handle a packet
|
||||
---@param pkt crdn_frame
|
||||
local function _handle_packet(pkt)
|
||||
@ -120,10 +162,11 @@ function coordinator.new_session(id, in_queue, out_queue, facility_units)
|
||||
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
|
||||
end
|
||||
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_CRDN then
|
||||
if pkt.type == SCADA_CRDN_TYPES.QUERY_UNIT then
|
||||
-- return unit statuses
|
||||
|
||||
if pkt.type == SCADA_CRDN_TYPES.STRUCT_BUILDS then
|
||||
-- acknowledgement to coordinator receiving builds
|
||||
self.acks.builds = true
|
||||
else
|
||||
log.debug(log_header .. "handler received unexpected SCADA_CRDN packet type " .. pkt.type)
|
||||
end
|
||||
end
|
||||
end
|
||||
@ -202,7 +245,30 @@ function coordinator.new_session(id, in_queue, out_queue, facility_units)
|
||||
periodics.keep_alive = 0
|
||||
end
|
||||
|
||||
-- unit statuses to coordinator
|
||||
|
||||
periodics.status_packet = periodics.status_packet + elapsed
|
||||
if periodics.status_packet >= PERIODICS.STATUS then
|
||||
_send_status()
|
||||
periodics.status_packet = 0
|
||||
end
|
||||
|
||||
self.periodics.last_update = util.time()
|
||||
|
||||
---------------------
|
||||
-- attempt retries --
|
||||
---------------------
|
||||
|
||||
local rtimes = self.retry_times
|
||||
|
||||
-- builds packet retry
|
||||
|
||||
if not self.acks.builds then
|
||||
if rtimes.builds_packet - util.time() <= 0 then
|
||||
_send_builds()
|
||||
rtimes.builds_packet = util.time() + RETRY_PERIOD
|
||||
end
|
||||
end
|
||||
end
|
||||
|
||||
return self.connected
|
||||
|
@ -404,13 +404,13 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
build.boilers = {}
|
||||
for i = 1, #self.boilers do
|
||||
local boiler = self.boilers[i] ---@type unit_session
|
||||
build.boilers[boiler.get_device_idx()] = { formed = boiler.get_db().formed, build = boiler.get_db().build }
|
||||
build.boilers[boiler.get_device_idx()] = { boiler.get_db().formed, boiler.get_db().build }
|
||||
end
|
||||
|
||||
build.turbines = {}
|
||||
for i = 1, #self.turbines do
|
||||
local turbine = self.turbines[i] ---@type unit_session
|
||||
build.turbines[turbine.get_device_idx()] = { formed = turbine.get_db().formed, build = turbine.get_db().build }
|
||||
build.turbines[turbine.get_device_idx()] = { turbine.get_db().formed, turbine.get_db().build }
|
||||
end
|
||||
|
||||
return build
|
||||
@ -438,14 +438,14 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
status.boilers = {}
|
||||
for i = 1, #self.boilers do
|
||||
local boiler = self.boilers[i] ---@type unit_session
|
||||
status.boilers[boiler.get_device_idx()] = { state = boiler.get_db().state, tanks = boiler.get_db().tanks }
|
||||
status.boilers[boiler.get_device_idx()] = { boiler.get_db().state, boiler.get_db().tanks }
|
||||
end
|
||||
|
||||
-- status of turbines (including tanks)
|
||||
status.turbines = {}
|
||||
for i = 1, #self.turbines do
|
||||
local turbine = self.turbines[i] ---@type unit_session
|
||||
status.turbines[turbine.get_device_idx()] = { state = turbine.get_db().state, tanks = turbine.get_db().tanks }
|
||||
status.turbines[turbine.get_device_idx()] = { turbine.get_db().state, turbine.get_db().tanks }
|
||||
end
|
||||
|
||||
return status
|
||||
@ -454,6 +454,9 @@ function unit.new(for_reactor, num_boilers, num_turbines)
|
||||
-- get the annunciator status
|
||||
function public.get_annunciator() return self.db.annunciator end
|
||||
|
||||
-- get the reactor ID
|
||||
function public.get_id() return self.r_id end
|
||||
|
||||
return public
|
||||
end
|
||||
|
||||
|
@ -13,7 +13,7 @@ local svsessions = require("supervisor.session.svsessions")
|
||||
local config = require("supervisor.config")
|
||||
local supervisor = require("supervisor.supervisor")
|
||||
|
||||
local SUPERVISOR_VERSION = "beta-v0.5.5"
|
||||
local SUPERVISOR_VERSION = "beta-v0.5.6"
|
||||
|
||||