@ -760,23 +760,24 @@ function iocontrol.update_facility_status(status)
|
||||
end
|
||||
|
||||
-- environment detector status
|
||||
if type(rtu_statuses.rad_mon) == "table" then
|
||||
if #rtu_statuses.rad_mon > 0 then
|
||||
local max_rad, max_reading, any_faulted = 0, types.new_zero_radiation_reading(), false
|
||||
if type(rtu_statuses.envds) == "table" then
|
||||
local max_rad, max_reading, any_conn, any_faulted = 0, types.new_zero_radiation_reading(), false, false
|
||||
|
||||
for i = 1, #rtu_statuses.rad_mon do
|
||||
local rad_mon = rtu_statuses.rad_mon[i]
|
||||
local rtu_faulted = rad_mon[1] ---@type boolean
|
||||
local radiation = rad_mon[2] ---@type radiation_reading
|
||||
local rad_raw = rad_mon[3] ---@type number
|
||||
for _, envd in pairs(rtu_statuses.envds) do
|
||||
local rtu_faulted = envd[1] ---@type boolean
|
||||
local radiation = envd[2] ---@type radiation_reading
|
||||
local rad_raw = envd[3] ---@type number
|
||||
|
||||
any_faulted = any_faulted or rtu_faulted
|
||||
if rad_raw > max_rad then
|
||||
max_rad = rad_raw
|
||||
max_reading = radiation
|
||||
end
|
||||
any_conn = true
|
||||
any_faulted = any_faulted or rtu_faulted
|
||||
|
||||
if rad_raw > max_rad then
|
||||
max_rad = rad_raw
|
||||
max_reading = radiation
|
||||
end
|
||||
end
|
||||
|
||||
if any_conn then
|
||||
fac.radiation = max_reading
|
||||
fac.ps.publish("rad_computed_status", util.trinary(any_faulted, 2, 3))
|
||||
else
|
||||
@ -786,7 +787,7 @@ function iocontrol.update_facility_status(status)
|
||||
|
||||
fac.ps.publish("radiation", fac.radiation)
|
||||
else
|
||||
log.debug(log_header .. "radiation monitor list not a table")
|
||||
log.debug(log_header .. "environment detector list not a table")
|
||||
valid = false
|
||||
end
|
||||
else
|
||||
@ -1061,22 +1062,22 @@ function iocontrol.update_unit_statuses(statuses)
|
||||
end
|
||||
|
||||
-- environment detector status
|
||||
if type(rtu_statuses.rad_mon) == "table" then
|
||||
local max_rad, max_reading = 0, types.new_zero_radiation_reading()
|
||||
if type(rtu_statuses.envds) == "table" then
|
||||
local max_rad, max_reading, any_conn = 0, types.new_zero_radiation_reading(), false
|
||||
|
||||
if #rtu_statuses.rad_mon > 0 then
|
||||
for _, envd in pairs(rtu_statuses.envds) do
|
||||
local radiation = envd[2] ---@type radiation_reading
|
||||
local rad_raw = envd[3] ---@type number
|
||||
|
||||
for id = 1, #rtu_statuses.rad_mon do
|
||||
local rad_mon = rtu_statuses.rad_mon[id]
|
||||
local radiation = rad_mon[2] ---@type radiation_reading
|
||||
local rad_raw = rad_mon[3] ---@type number
|
||||
any_conn = true
|
||||
|
||||
if rad_raw > max_rad then
|
||||
max_rad = rad_raw
|
||||
max_reading = radiation
|
||||
end
|
||||
if rad_raw > max_rad then
|
||||
max_rad = rad_raw
|
||||
max_reading = radiation
|
||||
end
|
||||
end
|
||||
|
||||
if any_conn then
|
||||
unit.radiation = max_reading
|
||||
else
|
||||
unit.radiation = types.new_zero_radiation_reading()
|
||||
|
@ -710,6 +710,10 @@ local function config_view(display)
|
||||
tool_ctl.p_desc_ext.set_value("Before adding lots of SNAs: multiply the \"PEAK\" rate on the flow monitor (after connecting at least 1 SNA) by 10 to get the mB/t of waste that they can process. Enough SNAs to provide 2x to 3x of your max burn rate should be a good margin to catch up after night or cloudy weather. Too many devices (such as SNAs) on one RTU can cause lag.")
|
||||
elseif type == "dynamicValve" then
|
||||
tool_ctl.p_prompt.set_value("This is the # dynamic tank for...")
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.set_max(4)
|
||||
@ -724,23 +728,19 @@ local function config_view(display)
|
||||
tool_ctl.p_unit.enable()
|
||||
end
|
||||
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_desc.reposition(1, 8)
|
||||
tool_ctl.p_desc.set_value("Each reactor unit can have at most 1 tank and the facility can have at most 4. Each facility tank must have a unique # 1 through 4, regardless of where it is connected. Only a total of 4 tanks can be displayed on the flow monitor.")
|
||||
elseif type == "environmentDetector" then
|
||||
tool_ctl.p_prompt.set_value("This is the # environment detector for...")
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_idx.show()
|
||||
tool_ctl.p_idx.redraw()
|
||||
tool_ctl.p_idx.set_max(99)
|
||||
tool_ctl.p_unit.reposition(18, 6)
|
||||
if tool_ctl.p_assign_btn.get_value() == 1 then tool_ctl.p_unit.disable() else tool_ctl.p_unit.enable() end
|
||||
tool_ctl.p_assign_btn.show()
|
||||
tool_ctl.p_assign_btn.redraw()
|
||||
tool_ctl.p_assign_end.show()
|
||||
tool_ctl.p_assign_end.redraw()
|
||||
tool_ctl.p_desc.reposition(1, 8)
|
||||
tool_ctl.p_desc.set_value("You can connect more than one environment detector for a particular unit or the facility. In that case, the maximum radiation reading from those assigned to that particular unit or the facility will be used for alarms and display.")
|
||||
elseif type == "inductionPort" or type == "spsPort" then
|
||||
@ -882,6 +882,8 @@ local function config_view(display)
|
||||
tool_ctl.p_err.show()
|
||||
return
|
||||
else index = idx end
|
||||
elseif peri_type == "dynamicValve" then
|
||||
index = 1
|
||||
elseif peri_type == "environmentDetector" then
|
||||
if not (util.is_int(idx) and idx > 0) then
|
||||
tool_ctl.p_err.set_value("Index must be greater than 0.")
|
||||
|
@ -157,18 +157,18 @@ local function main()
|
||||
---@cast for_reactor integer
|
||||
assignment = "reactor unit " .. entry.unit
|
||||
if rs_rtus[for_reactor] == nil then
|
||||
log.debug(util.c("configure> allocated redstone RTU for reactor unit ", entry.unit))
|
||||
log.debug(util.c("sys_config> allocated redstone RTU for reactor unit ", entry.unit))
|
||||
rs_rtus[for_reactor] = { rtu = redstone_rtu.new(), capabilities = {} }
|
||||
end
|
||||
elseif entry.unit == nil then
|
||||
assignment = "facility"
|
||||
for_reactor = 0
|
||||
if rs_rtus[for_reactor] == nil then
|
||||
log.debug(util.c("configure> allocated redstone RTU for the facility"))
|
||||
log.debug(util.c("sys_config> allocated redstone RTU for the facility"))
|
||||
rs_rtus[for_reactor] = { rtu = redstone_rtu.new(), capabilities = {} }
|
||||
end
|
||||
else
|
||||
local message = util.c("configure> invalid unit assignment at block index #", entry_idx)
|
||||
local message = util.c("sys_config> invalid unit assignment at block index #", entry_idx)
|
||||
println(message)
|
||||
log.fatal(message)
|
||||
return false
|
||||
@ -184,7 +184,7 @@ local function main()
|
||||
local capabilities = rs_rtus[for_reactor].capabilities
|
||||
|
||||
if not valid then
|
||||
local message = util.c("configure> invalid redstone definition at block index #", entry_idx)
|
||||
local message = util.c("sys_config> invalid redstone definition at block index #", entry_idx)
|
||||
println(message)
|
||||
log.fatal(message)
|
||||
return false
|
||||
@ -194,7 +194,7 @@ local function main()
|
||||
if mode == rsio.IO_MODE.DIGITAL_IN then
|
||||
-- can't have duplicate inputs
|
||||
if util.table_contains(capabilities, entry.port) then
|
||||
local message = util.c("configure> skipping duplicate input for port ", rsio.to_string(entry.port), " on side ", iface_name)
|
||||
local message = util.c("sys_config> skipping duplicate input for port ", rsio.to_string(entry.port), " on side ", iface_name)
|
||||
println(message)
|
||||
log.warning(message)
|
||||
else
|
||||
@ -205,7 +205,7 @@ local function main()
|
||||
elseif mode == rsio.IO_MODE.ANALOG_IN then
|
||||
-- can't have duplicate inputs
|
||||
if util.table_contains(capabilities, entry.port) then
|
||||
local message = util.c("configure> skipping duplicate input for port ", rsio.to_string(entry.port), " on side ", iface_name)
|
||||
local message = util.c("sys_config> skipping duplicate input for port ", rsio.to_string(entry.port), " on side ", iface_name)
|
||||
println(message)
|
||||
log.warning(message)
|
||||
else
|
||||
@ -215,14 +215,14 @@ local function main()
|
||||
rs_rtu.link_ao(entry.side)
|
||||
else
|
||||
-- should be unreachable code, we already validated ports
|
||||
log.error("configure> fell through if chain attempting to identify IO mode at block index #" .. entry_idx, true)
|
||||
println("configure> encountered a software error, check logs")
|
||||
log.error("sys_config> fell through if chain attempting to identify IO mode at block index #" .. entry_idx, true)
|
||||
println("sys_config> encountered a software error, check logs")
|
||||
return false
|
||||
end
|
||||
|
||||
table.insert(capabilities, entry.port)
|
||||
|
||||
log.debug(util.c("configure> linked redstone ", #capabilities, ": ", rsio.to_string(entry.port), " (", iface_name, ") for ", assignment))
|
||||
log.debug(util.c("sys_config> linked redstone ", #capabilities, ": ", rsio.to_string(entry.port), " (", iface_name, ") for ", assignment))
|
||||
end
|
||||
end
|
||||
|
||||
@ -252,7 +252,7 @@ local function main()
|
||||
for_message = util.c("reactor unit ", for_reactor)
|
||||
end
|
||||
|
||||
log.info(util.c("configure> initialized RTU unit #", #units, ": redstone_io (redstone) [1] for ", for_message))
|
||||
log.info(util.c("sys_config> initialized RTU unit #", #units, ": redstone_io (redstone) [1] for ", for_message))
|
||||
|
||||
unit.uid = #units
|
||||
|
||||
@ -268,7 +268,7 @@ local function main()
|
||||
|
||||
-- CHECK: name is a string
|
||||
if type(name) ~= "string" then
|
||||
local message = util.c("configure> device entry #", i, ": device ", name, " isn't a string")
|
||||
local message = util.c("sys_config> device entry #", i, ": device ", name, " isn't a string")
|
||||
println(message)
|
||||
log.fatal(message)
|
||||
return false
|
||||
@ -276,7 +276,7 @@ local function main()
|
||||
|
||||
-- CHECK: index type
|
||||
if (index ~= nil) and (not util.is_int(index)) then
|
||||
local message = util.c("configure> device entry #", i, ": index ", index, " isn't valid")
|
||||
local message = util.c("sys_config> device entry #", i, ": index ", index, " isn't valid")
|
||||
println(message)
|
||||
log.fatal(message)
|
||||
return false
|
||||
@ -284,8 +284,9 @@ local function main()
|
||||
|
||||
-- CHECK: index range
|
||||
local function validate_index(min, max)
|
||||
if (util.is_int(index) and index < min) and (max ~= nil and index > max) then
|
||||
local message = util.c("configure> device entry #", i, ": index ", index, " isn't >= ", min, " and <= ", max)
|
||||
if (not util.is_int(index)) or ((index < min) and (max ~= nil and index > max)) then
|
||||
local message = util.c("sys_config> device entry #", i, ": index ", index, " isn't >= ", min)
|
||||
if max ~= nil then message = util.c(message, " and <= ", max) end
|
||||
println(message)
|
||||
log.fatal(message)
|
||||
return false
|
||||
@ -295,12 +296,12 @@ local function main()
|
||||
-- CHECK: reactor is an integer >= 0
|
||||
local function validate_assign(for_facility)
|
||||
if for_facility and for_reactor ~= 0 then
|
||||
local message = util.c("configure> device entry #", i, ": must only be for the facility")
|
||||
local message = util.c("sys_config> device entry #", i, ": must only be for the facility")
|
||||
println(message)
|
||||
log.fatal(message)
|
||||
return false
|
||||
elseif (not for_facility) and ((not util.is_int(for_reactor)) or (for_reactor < 1) or (for_reactor > 4)) then
|
||||
local message = util.c("configure> device entry #", i, ": unit assignment ", for_reactor, " isn't vaild")
|
||||
local message = util.c("sys_config> device entry #", i, ": unit assignment ", for_reactor, " isn't vaild")
|
||||
println(message)
|
||||
log.fatal(message)
|
||||
return false
|
||||
@ -317,7 +318,7 @@ local function main()
|
||||
local faulted = nil ---@type boolean|nil
|
||||
|
||||
if device == nil then
|
||||
local message = util.c("configure> '", name, "' not found, using placeholder")
|
||||
local message = util.c("sys_config> '", name, "' not found, using placeholder")
|
||||
println(message)
|
||||
log.warning(message)
|
||||
|
||||
@ -338,8 +339,8 @@ local function main()
|
||||
formed = device.isFormed()
|
||||
|
||||
if formed == ppm.UNDEFINED_FIELD or formed == ppm.ACCESS_FAULT then
|
||||
println_ts(util.c("configure> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("configure> failed to check if '", name, "' is a formed boiler multiblock"))
|
||||
println_ts(util.c("sys_config> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("sys_config> failed to check if '", name, "' is a formed boiler multiblock"))
|
||||
return false
|
||||
end
|
||||
elseif type == "turbineValve" then
|
||||
@ -353,8 +354,8 @@ local function main()
|
||||
formed = device.isFormed()
|
||||
|
||||
if formed == ppm.UNDEFINED_FIELD or formed == ppm.ACCESS_FAULT then
|
||||
println_ts(util.c("configure> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("configure> failed to check if '", name, "' is a formed turbine multiblock"))
|
||||
println_ts(util.c("sys_config> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("sys_config> failed to check if '", name, "' is a formed turbine multiblock"))
|
||||
return false
|
||||
end
|
||||
elseif type == "dynamicValve" then
|
||||
@ -373,8 +374,8 @@ local function main()
|
||||
formed = device.isFormed()
|
||||
|
||||
if formed == ppm.UNDEFINED_FIELD or formed == ppm.ACCESS_FAULT then
|
||||
println_ts(util.c("configure> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("configure> failed to check if '", name, "' is a formed dynamic tank multiblock"))
|
||||
println_ts(util.c("sys_config> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("sys_config> failed to check if '", name, "' is a formed dynamic tank multiblock"))
|
||||
return false
|
||||
end
|
||||
elseif type == "inductionPort" then
|
||||
@ -387,8 +388,8 @@ local function main()
|
||||
formed = device.isFormed()
|
||||
|
||||
if formed == ppm.UNDEFINED_FIELD or formed == ppm.ACCESS_FAULT then
|
||||
println_ts(util.c("configure> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("configure> failed to check if '", name, "' is a formed induction matrix multiblock"))
|
||||
println_ts(util.c("sys_config> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("sys_config> failed to check if '", name, "' is a formed induction matrix multiblock"))
|
||||
return false
|
||||
end
|
||||
elseif type == "spsPort" then
|
||||
@ -401,8 +402,8 @@ local function main()
|
||||
formed = device.isFormed()
|
||||
|
||||
if formed == ppm.UNDEFINED_FIELD or formed == ppm.ACCESS_FAULT then
|
||||
println_ts(util.c("configure> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("configure> failed to check if '", name, "' is a formed SPS multiblock"))
|
||||
println_ts(util.c("sys_config> failed to check if '", name, "' is formed"))
|
||||
log.fatal(util.c("sys_config> failed to check if '", name, "' is a formed SPS multiblock"))
|
||||
return false
|
||||
end
|
||||
elseif type == "solarNeutronActivator" then
|
||||
@ -423,7 +424,7 @@ local function main()
|
||||
rtu_type = RTU_UNIT_TYPE.VIRTUAL
|
||||
rtu_iface = rtu.init_unit().interface()
|
||||
else
|
||||
local message = util.c("configure> device '", name, "' is not a known type (", type, ")")
|
||||
local message = util.c("sys_config> device '", name, "' is not a known type (", type, ")")
|
||||
println_ts(message)
|
||||
log.fatal(message)
|
||||
return false
|
||||
@ -431,12 +432,12 @@ local function main()
|
||||
|
||||
if is_multiblock then
|
||||
if not formed then
|
||||
log.info(util.c("configure> device '", name, "' is not formed"))
|
||||
log.info(util.c("sys_config> device '", name, "' is not formed"))
|
||||
elseif faulted then
|
||||
-- sometimes there is a race condition on server boot where it reports formed, but
|
||||
-- the other functions are not yet defined (that's the theory at least). mark as unformed to attempt connection later
|
||||
formed = false
|
||||
log.warning(util.c("configure> device '", name, "' is formed, but initialization had one or more faults: marked as unformed"))
|
||||
log.warning(util.c("sys_config> device '", name, "' is formed, but initialization had one or more faults: marked as unformed"))
|
||||
end
|
||||
end
|
||||
|
||||
@ -466,7 +467,7 @@ local function main()
|
||||
for_message = util.c("reactor ", for_reactor)
|
||||
end
|
||||
|
||||
log.info(util.c("configure> initialized RTU unit #", #units, ": ", name, " (", types.rtu_type_to_string(rtu_type), ") [", index, "] for ", for_message))
|
||||
log.info(util.c("sys_config> initialized RTU unit #", #units, ": ", name, " (", types.rtu_type_to_string(rtu_type), ") [", index, "] for ", for_message))
|
||||
|
||||
rtu_unit.uid = #units
|
||||
|
||||
|
@ -1171,11 +1171,11 @@ function facility.new(num_reactors, cooling_conf)
|
||||
end
|
||||
|
||||
-- radiation monitors (environment detectors)
|
||||
status.rad_mon = {}
|
||||
status.envds = {}
|
||||
for i = 1, #self.envd do
|
||||
local envd = self.envd[i] ---@type unit_session
|
||||
local db = envd.get_db() ---@type envd_session_db
|
||||
status.rad_mon[envd.get_device_idx()] = { envd.is_faulted(), db.radiation, db.radiation_raw }
|
||||
status.envds[envd.get_device_idx()] = { envd.is_faulted(), db.radiation, db.radiation_raw }
|
||||
end
|
||||
|
||||
return status
|
||||
|
@ -864,11 +864,11 @@ function unit.new(reactor_id, num_boilers, num_turbines)
|
||||
status.sna = { #self.snas, public.get_sna_rate(), total_peak }
|
||||
|
||||
-- radiation monitors (environment detectors)
|
||||
status.rad_mon = {}
|
||||
status.envds = {}
|
||||
for i = 1, #self.envd do
|
||||
local envd = self.envd[i] ---@type unit_session
|
||||
local db = envd.get_db() ---@type envd_session_db
|
||||
status.rad_mon[envd.get_device_idx()] = { envd.is_faulted(), db.radiation, db.radiation_raw }
|
||||
status.envds[envd.get_device_idx()] = { envd.is_faulted(), db.radiation, db.radiation_raw }
|
||||
end
|
||||
|
||||