mirror of
https://github.com/MikaylaFischler/cc-mek-scada.git
synced 2024-08-30 18:22:34 +00:00
#11 configurable 'networked' setting for PLCs that allows for standalone ISS-only mode
This commit is contained in:
parent
13b0fcf65f
commit
dbf7377c02
@ -1,3 +1,5 @@
|
||||
-- set to false to run in standalone mode (safety regulation only)
|
||||
NETWORKED = true
|
||||
-- unique reactor ID
|
||||
REACTOR_ID = 1
|
||||
-- port to send packets TO server
|
||||
|
@ -22,6 +22,8 @@ ppm.mount_all()
|
||||
local reactor = ppm.get_device("fissionReactor")
|
||||
local modem = ppm.get_device("modem")
|
||||
|
||||
local networked = config.NETWORKED
|
||||
|
||||
local plc_state = {
|
||||
init_ok = true,
|
||||
scram = true, -- treated as latching e-stop, all conditions must be OK to set false
|
||||
@ -38,7 +40,7 @@ if reactor == nil then
|
||||
plc_state.degraded = true
|
||||
plc_state.no_reactor = true
|
||||
end
|
||||
if modem == nil then
|
||||
if networked and modem == nil then
|
||||
if reactor ~= nil then
|
||||
print_ts("No modem found. Disabling reactor and running in a degraded state...\n")
|
||||
reactor.scram()
|
||||
@ -52,37 +54,46 @@ if modem == nil then
|
||||
plc_state.no_modem = true
|
||||
end
|
||||
|
||||
::init::
|
||||
if plc_state.init_ok then
|
||||
-- just booting up, no fission allowed (neutrons stay put thanks)
|
||||
reactor.scram()
|
||||
|
||||
-- init internal safety system
|
||||
local iss = plc.iss_init(reactor)
|
||||
log._debug("iss init")
|
||||
|
||||
-- start comms
|
||||
local plc_comms = plc.comms_init(config.REACTOR_ID, modem, config.LISTEN_PORT, config.SERVER_PORT, reactor, iss)
|
||||
log._debug("comms init")
|
||||
|
||||
-- comms watchdog, 3 second timeout
|
||||
local conn_watchdog = watchdog.new_watchdog(3)
|
||||
log._debug("conn watchdog started")
|
||||
|
||||
-- loop clock (10Hz, 2 ticks)
|
||||
local loop_tick = os.startTimer(0.05)
|
||||
log._debug("loop clock started")
|
||||
else
|
||||
log._warning("booted in a degraded state, awaiting peripheral connections...")
|
||||
end
|
||||
local iss = nil
|
||||
local plc_comms = nil
|
||||
local conn_watchdog = nil
|
||||
|
||||
-- send status updates at ~3.33Hz (every 6 server ticks) (every 3 loop ticks)
|
||||
-- send link requests at 0.5Hz (every 40 server ticks) (every 20 loop ticks)
|
||||
local UPDATE_TICKS = 3
|
||||
local LINK_TICKS = 20
|
||||
|
||||
-- start by linking
|
||||
local ticks_to_update = LINK_TICKS
|
||||
local loop_tick = nil
|
||||
local ticks_to_update = LINK_TICKS -- start by linking
|
||||
|
||||
-- initialize PLC
|
||||
::init::
|
||||
if plc_state.init_ok then
|
||||
-- just booting up, no fission allowed (neutrons stay put thanks)
|
||||
reactor.scram()
|
||||
|
||||
-- init internal safety system
|
||||
iss = plc.iss_init(reactor)
|
||||
log._debug("iss init")
|
||||
|
||||
if networked then
|
||||
-- start comms
|
||||
plc_comms = plc.comms_init(config.REACTOR_ID, modem, config.LISTEN_PORT, config.SERVER_PORT, reactor, iss)
|
||||
log._debug("comms init")
|
||||
|
||||
-- comms watchdog, 3 second timeout
|
||||
conn_watchdog = watchdog.new_watchdog(3)
|
||||
log._debug("conn watchdog started")
|
||||
else
|
||||
log._debug("running without networking")
|
||||
end
|
||||
|
||||
-- loop clock (10Hz, 2 ticks)
|
||||
loop_tick = os.startTimer(0.05)
|
||||
log._debug("loop clock started")
|
||||
else
|
||||
log._warning("booted in a degraded state, awaiting peripheral connections...")
|
||||
end
|
||||
|
||||
-- event loop
|
||||
while true do
|
||||
@ -93,7 +104,7 @@ while true do
|
||||
-- if it disconnected, isPowered will return nil (and error logs will get spammed at 10Hz, so disable reporting)
|
||||
-- in that case, SCRAM won't be called until it reconnects (this is the expected use of this check)
|
||||
ppm.disable_reporting()
|
||||
if plc_state.scram and reactor.isPowered() then
|
||||
if plc_state.degraded or (plc_state.scram and reactor.isPowered()) then
|
||||
reactor.scram()
|
||||
end
|
||||
ppm.enable_reporting()
|
||||
@ -108,7 +119,7 @@ while true do
|
||||
log._error("reactor disconnected!")
|
||||
plc_state.no_reactor = true
|
||||
-- send an alarm: plc_comms.send_alarm(ALARMS.PLC_PERI_DC) ?
|
||||
elseif device.type == "modem" then
|
||||
elseif networked and device.type == "modem" then
|
||||
print_ts("modem disconnected!\n")
|
||||
log._error("modem disconnected!")
|
||||
plc_state.no_modem = true
|
||||
@ -139,14 +150,16 @@ while true do
|
||||
|
||||
if plc_state.init_ok then
|
||||
iss.reconnect_reactor(device)
|
||||
plc_comms.reconnect_reactor(device)
|
||||
if networked then
|
||||
plc_comms.reconnect_reactor(device)
|
||||
end
|
||||
end
|
||||
|
||||
-- determine if we are still in a degraded state
|
||||
if get_device("modem") not nil then
|
||||
if not networked or get_device("modem") not nil then
|
||||
plc_state.degraded = false
|
||||
end
|
||||
elseif device.type == "modem" then
|
||||
elseif networked and device.type == "modem" then
|
||||
-- reconnected modem
|
||||
if plc_state.init_ok then
|
||||
plc_comms.reconnect_modem(device)
|
||||
@ -172,31 +185,29 @@ while true do
|
||||
if not plc_state.degraded then
|
||||
local iss_tripped, iss_status, iss_first = iss.check()
|
||||
plc_state.scram = plc_state.scram or iss_tripped
|
||||
if iss_first then
|
||||
if networked and iss_first then
|
||||
plc_comms.send_iss_alarm(iss_status)
|
||||
end
|
||||
end
|
||||
|
||||
-- handle event
|
||||
if event == "timer" and param1 == loop_tick then
|
||||
if not plc_state.no_modem then
|
||||
-- basic event tick, send updated data if it is time (~3.33Hz)
|
||||
-- iss was already checked (main reason for this tick rate)
|
||||
ticks_to_update = ticks_to_update - 1
|
||||
if event == "timer" and param1 == loop_tick and networked and not plc_state.no_modem then
|
||||
-- basic event tick, send updated data if it is time (~3.33Hz)
|
||||
-- iss was already checked (that's the main reason for this tick rate)
|
||||
ticks_to_update = ticks_to_update - 1
|
||||
|
||||
if plc_comms.is_linked() then
|
||||
if ticks_to_update <= 0 then
|
||||
plc_comms.send_status(iss_tripped)
|
||||
ticks_to_update = UPDATE_TICKS
|
||||
end
|
||||
else
|
||||
if ticks_to_update <= 0 then
|
||||
plc_comms.send_link_req()
|
||||
ticks_to_update = LINK_TICKS
|
||||
end
|
||||
if plc_comms.is_linked() then
|
||||
if ticks_to_update <= 0 then
|
||||
plc_comms.send_status(iss_tripped)
|
||||
ticks_to_update = UPDATE_TICKS
|
||||
end
|
||||
else
|
||||
if ticks_to_update <= 0 then
|
||||
plc_comms.send_link_req()
|
||||
ticks_to_update = LINK_TICKS
|
||||
end
|
||||
end
|
||||
elseif event == "modem_message" then
|
||||
elseif event == "modem_message" and networked and not plc_state.no_modem then
|
||||
-- got a packet
|
||||
-- feed the watchdog first so it doesn't uhh...eat our packets
|
||||
conn_watchdog.feed()
|
||||
@ -204,7 +215,7 @@ while true do
|
||||
local packet = plc_comms.parse_packet(p1, p2, p3, p4, p5)
|
||||
plc_comms.handle_packet(packet)
|
||||
plc_state.scram = plc_state.scram or plc_comms.is_scrammed()
|
||||
elseif event == "timer" and param1 == conn_watchdog.get_timer() then
|
||||
elseif event == "timer" and param1 == conn_watchdog.get_timer() and networked then
|
||||
-- haven't heard from server recently? shutdown reactor
|
||||
plc_state.scram = true
|
||||
plc_comms.unlink()
|
||||
|
Loading…
Reference in New Issue