#290 pocket page management and alarm test tool, supervisor pocket diagnostics system

This commit is contained in:
Mikayla Fischler 2023-07-29 18:16:59 -04:00
parent 775d4dc95b
commit df67795239
16 changed files with 858 additions and 250 deletions

View File

@ -7,7 +7,7 @@ local flasher = require("graphics.flasher")
local core = {}
core.version = "1.0.3"
core.version = "1.1.0"
core.flasher = flasher
core.events = events

View File

@ -0,0 +1,130 @@
-- Button Graphics Element
local tcd = require("scada-common.tcd")
local core = require("graphics.core")
local element = require("graphics.element")
local CLICK_TYPE = core.events.CLICK_TYPE
---@class app_button_args
---@field text string app icon text
---@field title string app title text
---@field callback function function to call on touch
---@field app_fg_bg cpair app icon foreground/background colors
---@field active_fg_bg? cpair foreground/background colors when pressed
---@field parent graphics_element
---@field id? string element id
---@field x? integer 1 if omitted
---@field y? integer auto incremented if omitted
---@field fg_bg? cpair foreground/background colors
---@field hidden? boolean true to hide on initial draw
-- new app button
---@param args app_button_args
---@return graphics_element element, element_id id
local function app_button(args)
assert(type(args.text) == "string", "graphics.elements.controls.app: text is a required field")
assert(type(args.title) == "string", "graphics.elements.controls.app: title is a required field")
assert(type(args.callback) == "function", "graphics.elements.controls.app: callback is a required field")
assert(type(args.app_fg_bg) == "table", "graphics.elements.controls.app: app_fg_bg is a required field")
args.height = 4
args.width = 5
-- create new graphics element base object
local e = element.new(args)
-- write app title, centered
e.window.setCursorPos(1, 4)
e.window.setCursorPos(math.floor((e.frame.w - string.len(args.title)) / 2) + 1, 4)
e.window.write(args.title)
-- draw the button
local function draw()
local fgd = args.app_fg_bg.fgd
local bkg = args.app_fg_bg.bkg
if e.value then
fgd = args.active_fg_bg.fgd
bkg = args.active_fg_bg.bkg
end
-- draw icon
e.window.setCursorPos(1, 1)
e.window.setTextColor(fgd)
e.window.setBackgroundColor(bkg)
e.window.write("\x9f\x83\x83\x83")
e.window.setTextColor(bkg)
e.window.setBackgroundColor(fgd)
e.window.write("\x90")
e.window.setTextColor(fgd)
e.window.setBackgroundColor(bkg)
e.window.setCursorPos(1, 2)
e.window.write("\x95 ")
e.window.setTextColor(bkg)
e.window.setBackgroundColor(fgd)
e.window.write("\x95")
e.window.setCursorPos(1, 3)
e.window.write("\x82\x8f\x8f\x8f\x81")
-- write the icon text
e.window.setCursorPos(3, 2)
e.window.setTextColor(fgd)
e.window.setBackgroundColor(bkg)
e.window.write(args.text)
end
-- draw the button as pressed (if active_fg_bg set)
local function show_pressed()
if e.enabled and args.active_fg_bg ~= nil then
e.value = true
e.window.setTextColor(args.active_fg_bg.fgd)
e.window.setBackgroundColor(args.active_fg_bg.bkg)
draw()
end
end
-- draw the button as unpressed (if active_fg_bg set)
local function show_unpressed()
if e.enabled and args.active_fg_bg ~= nil then
e.value = false
e.window.setTextColor(e.fg_bg.fgd)
e.window.setBackgroundColor(e.fg_bg.bkg)
draw()
end
end
-- handle mouse interaction
---@param event mouse_interaction mouse event
function e.handle_mouse(event)
if e.enabled then
if event.type == CLICK_TYPE.TAP then
show_pressed()
-- show as unpressed in 0.25 seconds
if args.active_fg_bg ~= nil then tcd.dispatch(0.25, show_unpressed) end
args.callback()
elseif event.type == CLICK_TYPE.DOWN then
show_pressed()
elseif event.type == CLICK_TYPE.UP then
show_unpressed()
if e.in_frame_bounds(event.current.x, event.current.y) then
args.callback()
end
end
end
end
-- set the value (true simulates pressing the button)
---@param val boolean new value
function e.set_value(val)
if val then e.handle_mouse(core.events.mouse_generic(core.events.CLICK_TYPE.UP, 1, 1)) end
end
-- initial draw
draw()
return e.complete()
end
return app_button

View File

@ -1,35 +0,0 @@
--
-- Core I/O - Pocket Central I/O Management
--
local psil = require("scada-common.psil")
local coreio = {}
---@class pocket_core_io
local io = {
ps = psil.create()
}
---@enum POCKET_LINK_STATE
local LINK_STATE = {
UNLINKED = 0,
SV_LINK_ONLY = 1,
API_LINK_ONLY = 2,
LINKED = 3
}
coreio.LINK_STATE = LINK_STATE
-- get the core PSIL
function coreio.core_ps()
return io.ps
end
-- set network link state
---@param state POCKET_LINK_STATE
function coreio.report_link_state(state)
io.ps.publish("link_state", state)
end
return coreio

106
pocket/iocontrol.lua Normal file
View File

@ -0,0 +1,106 @@
--
-- I/O Control for Pocket Integration with Supervisor & Coordinator
--
local psil = require("scada-common.psil")
local types = require("scada-common.types")
local ALARM = types.ALARM
local iocontrol = {}
---@class pocket_ioctl
local io = {
ps = psil.create()
}
---@enum POCKET_LINK_STATE
local LINK_STATE = {
UNLINKED = 0,
SV_LINK_ONLY = 1,
API_LINK_ONLY = 2,
LINKED = 3
}
---@enum NAV_PAGE
local NAV_PAGE = {
HOME = 1,
UNITS = 2,
REACTORS = 3,
BOILERS = 4,
TURBINES = 5,
DIAG = 6,
D_ALARMS = 7
}
iocontrol.LINK_STATE = LINK_STATE
iocontrol.NAV_PAGE = NAV_PAGE
-- initialize facility-independent components of pocket iocontrol
---@param comms pocket_comms
function iocontrol.init_core(comms)
---@class pocket_ioctl_diag
io.diag = {}
-- alarm testing
io.diag.tone_test = {
test_1 = function (state) comms.diag__set_alarm_tone(1, state) end,
test_2 = function (state) comms.diag__set_alarm_tone(2, state) end,
test_3 = function (state) comms.diag__set_alarm_tone(3, state) end,
test_4 = function (state) comms.diag__set_alarm_tone(4, state) end,
test_5 = function (state) comms.diag__set_alarm_tone(5, state) end,
test_6 = function (state) comms.diag__set_alarm_tone(6, state) end,
test_7 = function (state) comms.diag__set_alarm_tone(7, state) end,
test_8 = function (state) comms.diag__set_alarm_tone(8, state) end,
stop_tones = function () comms.diag__set_alarm_tone(0, false) end,
test_breach = function (state) comms.diag__set_alarm(ALARM.ContainmentBreach, state) end,
test_rad = function (state) comms.diag__set_alarm(ALARM.ContainmentRadiation, state) end,
test_lost = function (state) comms.diag__set_alarm(ALARM.ReactorLost, state) end,
test_crit = function (state) comms.diag__set_alarm(ALARM.CriticalDamage, state) end,
test_dmg = function (state) comms.diag__set_alarm(ALARM.ReactorDamage, state) end,
test_overtemp = function (state) comms.diag__set_alarm(ALARM.ReactorOverTemp, state) end,
test_hightemp = function (state) comms.diag__set_alarm(ALARM.ReactorHighTemp, state) end,
test_wasteleak = function (state) comms.diag__set_alarm(ALARM.ReactorWasteLeak, state) end,
test_highwaste = function (state) comms.diag__set_alarm(ALARM.ReactorHighWaste, state) end,
test_rps = function (state) comms.diag__set_alarm(ALARM.RPSTransient, state) end,
test_rcs = function (state) comms.diag__set_alarm(ALARM.RCSTransient, state) end,
test_turbinet = function (state) comms.diag__set_alarm(ALARM.TurbineTrip, state) end,
stop_alarms = function () comms.diag__set_alarm(0, false) end,
get_tone_states = function () comms.diag__get_alarm_tones() end,
ready_warn = nil, ---@type graphics_element
tone_buttons = {},
alarm_buttons = {},
tone_indicators = {} -- indicators to update from supervisor tone states
}
---@class pocket_nav
io.nav = {
page = NAV_PAGE.HOME, ---@type NAV_PAGE
sub_pages = { NAV_PAGE.HOME, NAV_PAGE.UNITS, NAV_PAGE.REACTORS, NAV_PAGE.BOILERS, NAV_PAGE.TURBINES, NAV_PAGE.DIAG },
tasks = {}
}
-- add a task to be performed periodically while on a given page
---@param page NAV_PAGE page to add task to
---@param task function function to execute
function io.nav.register_task(page, task)
if io.nav.tasks[page] == nil then io.nav.tasks[page] = {} end
table.insert(io.nav.tasks[page], task)
end
end
-- initialize facility-dependent components of pocket iocontrol
function iocontrol.init_fac() end
-- set network link state
---@param state POCKET_LINK_STATE
function iocontrol.report_link_state(state) io.ps.publish("link_state", state) end
-- get the IO controller database
function iocontrol.get_db() return io end
return iocontrol

View File

@ -1,16 +1,15 @@
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local util = require("scada-common.util")
local coreio = require("pocket.coreio")
local iocontrol = require("pocket.iocontrol")
local PROTOCOL = comms.PROTOCOL
local DEVICE_TYPE = comms.DEVICE_TYPE
local ESTABLISH_ACK = comms.ESTABLISH_ACK
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
-- local CAPI_TYPE = comms.CAPI_TYPE
local LINK_STATE = coreio.LINK_STATE
local LINK_STATE = iocontrol.LINK_STATE
local pocket = {}
@ -79,20 +78,6 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
self.api.seq_num = self.api.seq_num + 1
end
-- send a packet to the coordinator API
-----@param msg_type CAPI_TYPE
-----@param msg table
-- local function _send_api(msg_type, msg)
-- local s_pkt = comms.scada_packet()
-- local pkt = comms.capi_packet()
-- pkt.make(msg_type, msg)
-- s_pkt.make(self.api.addr, self.api.seq_num, PROTOCOL.COORD_API, pkt.raw_sendable())
-- nic.transmit(crd_channel, pkt_channel, s_pkt)
-- self.api.seq_num = self.api.seq_num + 1
-- end
-- attempt supervisor connection establishment
local function _send_sv_establish()
_send_sv(SCADA_MGMT_TYPE.ESTABLISH, { comms.version, version, DEVICE_TYPE.PKT })
@ -147,7 +132,7 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
-- attempt to re-link if any of the dependent links aren't active
function public.link_update()
if not self.sv.linked then
coreio.report_link_state(util.trinary(self.api.linked, LINK_STATE.API_LINK_ONLY, LINK_STATE.UNLINKED))
iocontrol.report_link_state(util.trinary(self.api.linked, LINK_STATE.API_LINK_ONLY, LINK_STATE.UNLINKED))
if self.establish_delay_counter <= 0 then
_send_sv_establish()
@ -156,7 +141,7 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
self.establish_delay_counter = self.establish_delay_counter - 1
end
elseif not self.api.linked then
coreio.report_link_state(LINK_STATE.SV_LINK_ONLY)
iocontrol.report_link_state(LINK_STATE.SV_LINK_ONLY)
if self.establish_delay_counter <= 0 then
_send_api_establish()
@ -166,10 +151,29 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
end
else
-- linked, all good!
coreio.report_link_state(LINK_STATE.LINKED)
iocontrol.report_link_state(LINK_STATE.LINKED)
end
end
-- supervisor test alarm tones by tone
---@param id tone_id|0 tone ID, or 0 to stop all
---@param state boolean tone state
function public.diag__set_alarm_tone(id, state)
if self.sv.linked then _send_sv(SCADA_MGMT_TYPE.DIAG_TONE_SET, { id, state }) end
end
-- supervisor get active alarm tones
function public.diag__get_alarm_tones()
if self.sv.linked then _send_sv(SCADA_MGMT_TYPE.DIAG_TONE_GET, {}) end
end
-- supervisor test alarm tones by alarm
---@param id ALARM|0 alarm ID, 0 to stop all
---@param state boolean alarm state
function public.diag__set_alarm(id, state)
if self.sv.linked then _send_sv(SCADA_MGMT_TYPE.DIAG_ALARM_SET, { id, state }) end
end
-- parse a packet
---@param side string
---@param sender integer
@ -205,6 +209,8 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
-- handle a packet
---@param packet mgmt_frame|capi_frame|nil
function public.handle_packet(packet)
local diag = iocontrol.get_db().diag
if packet ~= nil then
local l_chan = packet.scada_frame.local_channel()
local r_chan = packet.scada_frame.remote_channel()
@ -231,47 +237,9 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
-- feed watchdog on valid sequence number
api_watchdog.feed()
if protocol == PROTOCOL.COORD_API then
---@cast packet capi_frame
elseif protocol == PROTOCOL.SCADA_MGMT then
if protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with coordinator established
if packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.ALLOW then
log.info("coordinator connection established")
self.establish_delay_counter = 0
self.api.linked = true
self.api.addr = src_addr
if self.sv.linked then
coreio.report_link_state(LINK_STATE.LINKED)
else
coreio.report_link_state(LINK_STATE.API_LINK_ONLY)
end
elseif est_ack == ESTABLISH_ACK.DENY then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator comms version mismatch")
end
else
log.debug("coordinator SCADA_MGMT establish packet reply unsupported")
end
self.api.last_est_ack = est_ack
else
log.debug("coordinator SCADA_MGMT establish packet length mismatch")
end
elseif self.api.linked then
if self.api.linked then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 then
@ -298,6 +266,42 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
else
log.debug("received unknown SCADA_MGMT packet type " .. packet.type .. " from coordinator")
end
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with coordinator established
if packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.ALLOW then
log.info("coordinator connection established")
self.establish_delay_counter = 0
self.api.linked = true
self.api.addr = src_addr
if self.sv.linked then
iocontrol.report_link_state(LINK_STATE.LINKED)
else
iocontrol.report_link_state(LINK_STATE.API_LINK_ONLY)
end
elseif est_ack == ESTABLISH_ACK.DENY then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.api.last_est_ack ~= est_ack then
log.info("coordinator comms version mismatch")
end
else
log.debug("coordinator SCADA_MGMT establish packet reply unsupported")
end
self.api.last_est_ack = est_ack
else
log.debug("coordinator SCADA_MGMT establish packet length mismatch")
end
else
log.debug("discarding coordinator non-link SCADA_MGMT packet before linked")
end
@ -325,43 +329,7 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
-- handle packet
if protocol == PROTOCOL.SCADA_MGMT then
---@cast packet mgmt_frame
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with supervisor established
if packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.ALLOW then
log.info("supervisor connection established")
self.establish_delay_counter = 0
self.sv.linked = true
self.sv.addr = src_addr
if self.api.linked then
coreio.report_link_state(LINK_STATE.LINKED)
else
coreio.report_link_state(LINK_STATE.SV_LINK_ONLY)
end
elseif est_ack == ESTABLISH_ACK.DENY then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor comms version mismatch")
end
else
log.debug("supervisor SCADA_MGMT establish packet reply unsupported")
end
self.sv.last_est_ack = est_ack
else
log.debug("supervisor SCADA_MGMT establish packet length mismatch")
end
elseif self.sv.linked then
if self.sv.linked then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 then
@ -385,9 +353,90 @@ function pocket.comms(version, nic, pkt_channel, svr_channel, crd_channel, range
self.sv.r_seq_num = nil
self.sv.addr = comms.BROADCAST
log.info("supervisor server connection closed by remote host")
elseif packet.type == SCADA_MGMT_TYPE.DIAG_TONE_GET then
if packet.length == 8 then
for i = 1, #packet.data do
diag.tone_test.tone_indicators[i].update(packet.data[i] == true)
end
else
log.debug("supervisor SCADA diag alarm states packet length mismatch")
end
elseif packet.type == SCADA_MGMT_TYPE.DIAG_TONE_SET then
if packet.length == 1 and packet.data[1] == false then
diag.tone_test.ready_warn.set_value("testing denied")
log.debug("supervisor SCADA diag tone set failed")
elseif packet.length == 2 and type(packet.data[2]) == "table" then
local ready = packet.data[1]
local states = packet.data[2]
diag.tone_test.ready_warn.set_value(util.trinary(ready, "", "system not ready"))
for i = 1, #states do
if diag.tone_test.tone_buttons[i] ~= nil then
diag.tone_test.tone_buttons[i].set_value(states[i] == true)
diag.tone_test.tone_indicators[i].update(states[i] == true)
end
end
else
log.debug("supervisor SCADA diag tone set packet length/type mismatch")
end
elseif packet.type == SCADA_MGMT_TYPE.DIAG_ALARM_SET then
if packet.length == 1 and packet.data[1] == false then
diag.tone_test.ready_warn.set_value("testing denied")
log.debug("supervisor SCADA diag alarm set failed")
elseif packet.length == 2 and type(packet.data[2]) == "table" then
local ready = packet.data[1]
local states = packet.data[2]
diag.tone_test.ready_warn.set_value(util.trinary(ready, "", "system not ready"))
for i = 1, #states do
if diag.tone_test.alarm_buttons[i] ~= nil then
diag.tone_test.alarm_buttons[i].set_value(states[i] == true)
end
end
else
log.debug("supervisor SCADA diag alarm set packet length/type mismatch")
end
else
log.debug("received unknown SCADA_MGMT packet type " .. packet.type .. " from supervisor")
end
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with supervisor established
if packet.length == 1 then
local est_ack = packet.data[1]
if est_ack == ESTABLISH_ACK.ALLOW then
log.info("supervisor connection established")
self.establish_delay_counter = 0
self.sv.linked = true
self.sv.addr = src_addr
if self.api.linked then
iocontrol.report_link_state(LINK_STATE.LINKED)
else
iocontrol.report_link_state(LINK_STATE.SV_LINK_ONLY)
end
elseif est_ack == ESTABLISH_ACK.DENY then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor connection denied")
end
elseif est_ack == ESTABLISH_ACK.COLLISION then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor connection denied due to collision")
end
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
if self.sv.last_est_ack ~= est_ack then
log.info("supervisor comms version mismatch")
end
else
log.debug("supervisor SCADA_MGMT establish packet reply unsupported")
end
self.sv.last_est_ack = est_ack
else
log.debug("supervisor SCADA_MGMT establish packet length mismatch")
end
else
log.debug("discarding supervisor non-link SCADA_MGMT packet before linked")
end

View File

@ -4,21 +4,21 @@
require("/initenv").init_env()
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local network = require("scada-common.network")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local network = require("scada-common.network")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
local core = require("graphics.core")
local core = require("graphics.core")
local config = require("pocket.config")
local coreio = require("pocket.coreio")
local pocket = require("pocket.pocket")
local renderer = require("pocket.renderer")
local config = require("pocket.config")
local iocontrol = require("pocket.iocontrol")
local pocket = require("pocket.pocket")
local renderer = require("pocket.renderer")
local POCKET_VERSION = "alpha-v0.5.2"
local POCKET_VERSION = "v0.6.0-alpha"
local println = util.println
local println_ts = util.println_ts
@ -73,7 +73,7 @@ local function main()
network.init_mac(config.AUTH_KEY)
end
coreio.report_link_state(coreio.LINK_STATE.UNLINKED)
iocontrol.report_link_state(iocontrol.LINK_STATE.UNLINKED)
-- get the communications modem
local modem = ppm.get_wireless_modem()
@ -104,6 +104,9 @@ local function main()
local MAIN_CLOCK = 0.5
local loop_clock = util.new_clock(MAIN_CLOCK)
-- init I/O control
iocontrol.init_core(pocket_comms)
----------------------------------------
-- start the UI
----------------------------------------
@ -128,6 +131,9 @@ local function main()
conn_wd.api.feed()
log.debug("startup> conn watchdog started")
local io_db = iocontrol.get_db()
local nav = io_db.nav
-- main event loop
while true do
local event, param1, param2, param3, param4, param5 = util.pull_event()
@ -140,6 +146,13 @@ local function main()
-- relink if necessary
pocket_comms.link_update()
-- update any tasks for the active page
if (type(nav.tasks[nav.page]) == "table") then
for i = 1, #nav.tasks[nav.page] do
nav.tasks[nav.page][i]()
end
end
loop_clock.start()
elseif conn_wd.sv.is_timer(param1) then
-- supervisor watchdog timeout

View File

@ -2,17 +2,18 @@
-- Pocket GUI Root
--
local coreio = require("pocket.coreio")
local iocontrol = require("pocket.iocontrol")
local style = require("pocket.ui.style")
local conn_waiting = require("pocket.ui.components.conn_waiting")
local home_page = require("pocket.ui.pages.home_page")
local unit_page = require("pocket.ui.pages.unit_page")
local reactor_page = require("pocket.ui.pages.reactor_page")
local boiler_page = require("pocket.ui.pages.boiler_page")
local diag_page = require("pocket.ui.pages.diag_page")
local home_page = require("pocket.ui.pages.home_page")
local reactor_page = require("pocket.ui.pages.reactor_page")
local turbine_page = require("pocket.ui.pages.turbine_page")
local unit_page = require("pocket.ui.pages.unit_page")
local core = require("graphics.core")
@ -22,6 +23,9 @@ local TextBox = require("graphics.elements.textbox")
local Sidebar = require("graphics.elements.controls.sidebar")
local LINK_STATE = iocontrol.LINK_STATE
local NAV_PAGE = iocontrol.NAV_PAGE
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
@ -29,6 +33,9 @@ local cpair = core.cpair
-- create new main view
---@param main graphics_element main displaybox
local function init(main)
local nav = iocontrol.get_db().nav
local ps = iocontrol.get_db().ps
-- window header message
TextBox{parent=main,y=1,text="",alignment=TEXT_ALIGN.LEFT,height=1,fg_bg=style.header}
@ -45,10 +52,10 @@ local function init(main)
local root_pane = MultiPane{parent=root_pane_div,x=1,y=1,panes=root_panes}
root_pane.register(coreio.core_ps(), "link_state", function (state)
if state == coreio.LINK_STATE.UNLINKED or state == coreio.LINK_STATE.API_LINK_ONLY then
root_pane.register(ps, "link_state", function (state)
if state == LINK_STATE.UNLINKED or state == LINK_STATE.API_LINK_ONLY then
root_pane.set_value(1)
elseif state == coreio.LINK_STATE.SV_LINK_ONLY then
elseif state == LINK_STATE.SV_LINK_ONLY then
root_pane.set_value(2)
else
root_pane.set_value(3)
@ -81,19 +88,36 @@ local function init(main)
{
char = "T",
color = cpair(colors.black,colors.white)
},
{
char = "D",
color = cpair(colors.black,colors.orange)
}
}
local pane_1 = home_page(page_div)
local pane_2 = unit_page(page_div)
local pane_3 = reactor_page(page_div)
local pane_4 = boiler_page(page_div)
local pane_5 = turbine_page(page_div)
local panes = { pane_1, pane_2, pane_3, pane_4, pane_5 }
local panes = { home_page(page_div), unit_page(page_div), reactor_page(page_div), boiler_page(page_div), turbine_page(page_div), diag_page(page_div) }
local page_pane = MultiPane{parent=page_div,x=1,y=1,panes=panes}
Sidebar{parent=main_pane,x=1,y=1,tabs=sidebar_tabs,fg_bg=cpair(colors.white,colors.gray),callback=page_pane.set_value}
local function navigate_sidebar(page)
if page == 1 then
nav.page = nav.sub_pages[NAV_PAGE.HOME]
elseif page == 2 then
nav.page = nav.sub_pages[NAV_PAGE.UNITS]
elseif page == 3 then
nav.page = nav.sub_pages[NAV_PAGE.REACTORS]
elseif page == 4 then
nav.page = nav.sub_pages[NAV_PAGE.BOILERS]
elseif page == 5 then
nav.page = nav.sub_pages[NAV_PAGE.TURBINES]
elseif page == 6 then
nav.page = nav.sub_pages[NAV_PAGE.DIAG]
end
page_pane.set_value(page)
end
Sidebar{parent=main_pane,x=1,y=1,tabs=sidebar_tabs,fg_bg=cpair(colors.white,colors.gray),callback=navigate_sidebar}
end
return init

View File

@ -0,0 +1,149 @@
-- local style = require("pocket.ui.style")
local iocontrol = require("pocket.iocontrol")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local MultiPane = require("graphics.elements.multipane")
local TextBox = require("graphics.elements.textbox")
local IndicatorLight = require("graphics.elements.indicators.light")
local App = require("graphics.elements.controls.app")
local Checkbox = require("graphics.elements.controls.checkbox")
local PushButton = require("graphics.elements.controls.push_button")
local SwitchButton = require("graphics.elements.controls.switch_button")
local cpair = core.cpair
local NAV_PAGE = iocontrol.NAV_PAGE
local TEXT_ALIGN = core.TEXT_ALIGN
-- new diagnostics page view
---@param root graphics_element parent
local function new_view(root)
local db = iocontrol.get_db()
local main = Div{parent=root,x=1,y=1}
local diag_home = Div{parent=main,x=1,y=1}
TextBox{parent=diag_home,text="Diagnostic Apps",x=1,y=2,height=1,alignment=TEXT_ALIGN.CENTER}
local alarm_test = Div{parent=main,x=1,y=1}
local panes = { diag_home, alarm_test }
local page_pane = MultiPane{parent=main,x=1,y=1,panes=panes}
local function navigate_diag()
page_pane.set_value(1)
db.nav.page = NAV_PAGE.DIAG
db.nav.sub_pages[NAV_PAGE.DIAG] = NAV_PAGE.DIAG
end
local function navigate_alarm()
page_pane.set_value(2)
db.nav.page = NAV_PAGE.D_ALARMS
db.nav.sub_pages[NAV_PAGE.DIAG] = NAV_PAGE.D_ALARMS
end
------------------------
-- Alarm Testing Page --
------------------------
db.nav.register_task(NAV_PAGE.D_ALARMS, db.diag.tone_test.get_tone_states)
local ttest = db.diag.tone_test
local c_wht_gray = cpair(colors.white, colors.gray)
local c_red_gray = cpair(colors.red, colors.gray)
local c_yel_gray = cpair(colors.yellow, colors.gray)
local c_blue_gray = cpair(colors.blue, colors.gray)
local audio = Div{parent=alarm_test,x=1,y=1}
TextBox{parent=audio,y=1,text="Alarm Sounder Tests",height=1,alignment=TEXT_ALIGN.CENTER}
ttest.ready_warn = TextBox{parent=audio,y=2,text="",height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=cpair(colors.yellow,colors.black)}
PushButton{parent=audio,x=13,y=18,text="\x11 BACK",min_width=8,fg_bg=cpair(colors.black,colors.lightGray),active_fg_bg=c_wht_gray,callback=navigate_diag}
local tones = Div{parent=audio,x=2,y=3,height=10,width=8,fg_bg=cpair(colors.black,colors.yellow)}
TextBox{parent=tones,text="Tones",height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=audio.get_fg_bg()}
local test_btns = {}
test_btns[1] = SwitchButton{parent=tones,text="TEST 1",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_1}
test_btns[2] = SwitchButton{parent=tones,text="TEST 2",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_2}
test_btns[3] = SwitchButton{parent=tones,text="TEST 3",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_3}
test_btns[4] = SwitchButton{parent=tones,text="TEST 4",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_4}
test_btns[5] = SwitchButton{parent=tones,text="TEST 5",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_5}
test_btns[6] = SwitchButton{parent=tones,text="TEST 6",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_6}
test_btns[7] = SwitchButton{parent=tones,text="TEST 7",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_7}
test_btns[8] = SwitchButton{parent=tones,text="TEST 8",min_width=8,active_fg_bg=c_wht_gray,callback=ttest.test_8}
ttest.tone_buttons = test_btns
local function stop_all_tones()
for i = 1, #test_btns do test_btns[i].set_value(false) end
ttest.stop_tones()
end
PushButton{parent=tones,text="STOP",min_width=8,active_fg_bg=c_wht_gray,fg_bg=cpair(colors.black,colors.red),callback=stop_all_tones}
local alarms = Div{parent=audio,x=11,y=3,height=15,fg_bg=cpair(colors.lightGray,colors.black)}
TextBox{parent=alarms,text="Alarms (\x13)",height=1,alignment=TEXT_ALIGN.CENTER,fg_bg=audio.get_fg_bg()}
local alarm_btns = {}
alarm_btns[1] = Checkbox{parent=alarms,label="BREACH",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_breach}
alarm_btns[2] = Checkbox{parent=alarms,label="RADIATION",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_rad}
alarm_btns[3] = Checkbox{parent=alarms,label="RCT LOST",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_lost}
alarm_btns[4] = Checkbox{parent=alarms,label="CRIT DAMAGE",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_crit}
alarm_btns[5] = Checkbox{parent=alarms,label="DAMAGE",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_dmg}
alarm_btns[6] = Checkbox{parent=alarms,label="OVER TEMP",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_overtemp}
alarm_btns[7] = Checkbox{parent=alarms,label="HIGH TEMP",min_width=15,box_fg_bg=c_yel_gray,callback=ttest.test_hightemp}
alarm_btns[8] = Checkbox{parent=alarms,label="WASTE LEAK",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_wasteleak}
alarm_btns[9] = Checkbox{parent=alarms,label="WASTE HIGH",min_width=15,box_fg_bg=c_yel_gray,callback=ttest.test_highwaste}
alarm_btns[10] = Checkbox{parent=alarms,label="RPS TRANS",min_width=15,box_fg_bg=c_yel_gray,callback=ttest.test_rps}
alarm_btns[11] = Checkbox{parent=alarms,label="RCS TRANS",min_width=15,box_fg_bg=c_yel_gray,callback=ttest.test_rcs}
alarm_btns[12] = Checkbox{parent=alarms,label="TURBINE TRP",min_width=15,box_fg_bg=c_red_gray,callback=ttest.test_turbinet}
ttest.alarm_buttons = alarm_btns
local function stop_all_alarms()
for i = 1, #alarm_btns do alarm_btns[i].set_value(false) end
ttest.stop_alarms()
end
PushButton{parent=alarms,x=3,y=15,text="STOP \x13",min_width=8,fg_bg=cpair(colors.black,colors.red),active_fg_bg=c_wht_gray,callback=stop_all_alarms}
local states = Div{parent=audio,x=2,y=14,height=5,width=8}
TextBox{parent=states,text="States",height=1,alignment=TEXT_ALIGN.CENTER}
local t_1 = IndicatorLight{parent=states,label="1",colors=c_blue_gray}
local t_2 = IndicatorLight{parent=states,label="2",colors=c_blue_gray}
local t_3 = IndicatorLight{parent=states,label="3",colors=c_blue_gray}
local t_4 = IndicatorLight{parent=states,label="4",colors=c_blue_gray}
local t_5 = IndicatorLight{parent=states,x=6,y=2,label="5",colors=c_blue_gray}
local t_6 = IndicatorLight{parent=states,x=6,label="6",colors=c_blue_gray}
local t_7 = IndicatorLight{parent=states,x=6,label="7",colors=c_blue_gray}
local t_8 = IndicatorLight{parent=states,x=6,label="8",colors=c_blue_gray}
ttest.tone_indicators = { t_1, t_2, t_3, t_4, t_5, t_6, t_7, t_8 }
--------------
-- App List --
--------------
App{parent=diag_home,x=3,y=4,text="\x0f",title="Alarm",callback=navigate_alarm,app_fg_bg=cpair(colors.black,colors.red),active_fg_bg=cpair(colors.white,colors.gray)}
App{parent=diag_home,x=10,y=4,text="\x1e",title="LoopT",callback=function()end,app_fg_bg=cpair(colors.black,colors.cyan)}
App{parent=diag_home,x=17,y=4,text="@",title="Comps",callback=function()end,app_fg_bg=cpair(colors.black,colors.orange)}
return main
end
return new_view

View File

@ -1,20 +1,21 @@
-- local style = require("pocket.ui.style")
local core = require("graphics.core")
local core = require("graphics.core")
local Div = require("graphics.elements.div")
local Div = require("graphics.elements.div")
local TextBox = require("graphics.elements.textbox")
local App = require("graphics.elements.controls.app")
-- local cpair = core.cpair
local TEXT_ALIGN = core.TEXT_ALIGN
local cpair = core.cpair
-- new home page view
---@param root graphics_element parent
local function new_view(root)
local main = Div{parent=root,x=1,y=1}
TextBox{parent=main,text="HOME",x=1,y=1,height=1,alignment=TEXT_ALIGN.CENTER}
App{parent=main,x=3,y=2,text="\x17",title="PRC",callback=function()end,app_fg_bg=cpair(colors.black,colors.purple)}
App{parent=main,x=10,y=2,text="\x15",title="CTL",callback=function()end,app_fg_bg=cpair(colors.black,colors.green)}
App{parent=main,x=17,y=2,text="\x08",title="DEV",callback=function()end,app_fg_bg=cpair(colors.black,colors.lightGray)}
App{parent=main,x=3,y=7,text="\x7f",title="Waste",callback=function()end,app_fg_bg=cpair(colors.black,colors.brown)}
App{parent=main,x=10,y=7,text="\xb6",title="Guide",callback=function()end,app_fg_bg=cpair(colors.black,colors.cyan)}
return main
end

View File

@ -14,51 +14,54 @@ local max_distance = nil ---@type number|nil maximum acceptable t
---@class comms
local comms = {}
comms.version = "2.2.0"
comms.version = "2.2.1"
---@enum PROTOCOL
local PROTOCOL = {
MODBUS_TCP = 0, -- our "MODBUS TCP"-esque protocol
RPLC = 1, -- reactor PLC protocol
SCADA_MGMT = 2, -- SCADA supervisor management, device advertisements, etc
SCADA_CRDN = 3, -- data/control packets for coordinators to/from supervisory controllers
COORD_API = 4 -- data/control packets for pocket computers to/from coordinators
MODBUS_TCP = 0, -- our "MODBUS TCP"-esque protocol
RPLC = 1, -- reactor PLC protocol
SCADA_MGMT = 2, -- SCADA supervisor management, device advertisements, etc
SCADA_CRDN = 3, -- data/control packets for coordinators to/from supervisory controllers
COORD_API = 4 -- data/control packets for pocket computers to/from coordinators
}
---@enum RPLC_TYPE
local RPLC_TYPE = {
STATUS = 0, -- reactor/system status
MEK_STRUCT = 1, -- mekanism build structure
MEK_BURN_RATE = 2, -- set burn rate
RPS_ENABLE = 3, -- enable reactor
RPS_SCRAM = 4, -- SCRAM reactor (manual request)
RPS_ASCRAM = 5, -- SCRAM reactor (automatic request)
RPS_STATUS = 6, -- RPS status
RPS_ALARM = 7, -- RPS alarm broadcast
RPS_RESET = 8, -- clear RPS trip (if in bad state, will trip immediately)
RPS_AUTO_RESET = 9, -- clear RPS trip if it is just a timeout or auto scram
AUTO_BURN_RATE = 10 -- set an automatic burn rate, PLC will respond with status, enable toggle speed limited
STATUS = 0, -- reactor/system status
MEK_STRUCT = 1, -- mekanism build structure
MEK_BURN_RATE = 2, -- set burn rate
RPS_ENABLE = 3, -- enable reactor
RPS_SCRAM = 4, -- SCRAM reactor (manual request)
RPS_ASCRAM = 5, -- SCRAM reactor (automatic request)
RPS_STATUS = 6, -- RPS status
RPS_ALARM = 7, -- RPS alarm broadcast
RPS_RESET = 8, -- clear RPS trip (if in bad state, will trip immediately)
RPS_AUTO_RESET = 9, -- clear RPS trip if it is just a timeout or auto scram
AUTO_BURN_RATE = 10 -- set an automatic burn rate, PLC will respond with status, enable toggle speed limited
}
---@enum SCADA_MGMT_TYPE
local SCADA_MGMT_TYPE = {
ESTABLISH = 0, -- establish new connection
KEEP_ALIVE = 1, -- keep alive packet w/ RTT
CLOSE = 2, -- close a connection
RTU_ADVERT = 3, -- RTU capability advertisement
RTU_DEV_REMOUNT = 4,-- RTU multiblock possbily changed (formed, unformed) due to PPM remount
RTU_TONE_ALARM = 5 -- instruct RTUs to play specified alarm tones
ESTABLISH = 0, -- establish new connection
KEEP_ALIVE = 1, -- keep alive packet w/ RTT
CLOSE = 2, -- close a connection
RTU_ADVERT = 3, -- RTU capability advertisement
RTU_DEV_REMOUNT = 4, -- RTU multiblock possbily changed (formed, unformed) due to PPM remount
RTU_TONE_ALARM = 5, -- instruct RTUs to play specified alarm tones
DIAG_TONE_GET = 6, -- diagnostic: get alarm tones
DIAG_TONE_SET = 7, -- diagnostic: set alarm tones
DIAG_ALARM_SET = 8 -- diagnostic: set alarm to simulate audio for
}
---@enum SCADA_CRDN_TYPE
local SCADA_CRDN_TYPE = {
INITIAL_BUILDS = 0, -- initial, complete builds packet to the coordinator
FAC_BUILDS = 1, -- facility RTU builds
FAC_STATUS = 2, -- state of facility and facility devices
FAC_CMD = 3, -- faility command
UNIT_BUILDS = 4, -- build of each reactor unit (reactor + RTUs)
UNIT_STATUSES = 5, -- state of each of the reactor units
UNIT_CMD = 6 -- command a reactor unit
INITIAL_BUILDS = 0, -- initial, complete builds packet to the coordinator
FAC_BUILDS = 1, -- facility RTU builds
FAC_STATUS = 2, -- state of facility and facility devices
FAC_CMD = 3, -- faility command
UNIT_BUILDS = 4, -- build of each reactor unit (reactor + RTUs)
UNIT_STATUSES = 5, -- state of each of the reactor units
UNIT_CMD = 6 -- command a reactor unit
}
---@enum CAPI_TYPE
@ -67,50 +70,50 @@ local CAPI_TYPE = {
---@enum ESTABLISH_ACK
local ESTABLISH_ACK = {
ALLOW = 0, -- link approved
DENY = 1, -- link denied
COLLISION = 2, -- link denied due to existing active link
BAD_VERSION = 3 -- link denied due to comms version mismatch
ALLOW = 0, -- link approved
DENY = 1, -- link denied
COLLISION = 2, -- link denied due to existing active link
BAD_VERSION = 3 -- link denied due to comms version mismatch
}
---@enum DEVICE_TYPE
local DEVICE_TYPE = {
PLC = 0, -- PLC device type for establish
RTU = 1, -- RTU device type for establish
SV = 2, -- supervisor device type for establish
CRDN = 3, -- coordinator device type for establish
PKT = 4 -- pocket device type for establish
PLC = 0, -- PLC device type for establish
RTU = 1, -- RTU device type for establish
SV = 2, -- supervisor device type for establish
CRDN = 3, -- coordinator device type for establish
PKT = 4 -- pocket device type for establish
}
---@enum PLC_AUTO_ACK
local PLC_AUTO_ACK = {
FAIL = 0, -- failed to set burn rate/burn rate invalid
DIRECT_SET_OK = 1, -- successfully set burn rate
RAMP_SET_OK = 2, -- successfully started burn rate ramping
ZERO_DIS_OK = 3 -- successfully disabled reactor with < 0.01 burn rate
FAIL = 0, -- failed to set burn rate/burn rate invalid
DIRECT_SET_OK = 1, -- successfully set burn rate
RAMP_SET_OK = 2, -- successfully started burn rate ramping
ZERO_DIS_OK = 3 -- successfully disabled reactor with < 0.01 burn rate
}
---@enum FAC_COMMAND
local FAC_COMMAND = {
SCRAM_ALL = 0, -- SCRAM all reactors
STOP = 1, -- stop automatic process control
START = 2, -- start automatic process control
ACK_ALL_ALARMS = 3, -- acknowledge all alarms on all units
SET_WASTE_MODE = 4, -- set automatic waste processing mode
SET_PU_FB = 5 -- set plutonium fallback mode
SCRAM_ALL = 0, -- SCRAM all reactors
STOP = 1, -- stop automatic process control
START = 2, -- start automatic process control
ACK_ALL_ALARMS = 3, -- acknowledge all alarms on all units
SET_WASTE_MODE = 4, -- set automatic waste processing mode
SET_PU_FB = 5 -- set plutonium fallback mode
}
---@enum UNIT_COMMAND
local UNIT_COMMAND = {
SCRAM = 0, -- SCRAM the reactor
START = 1, -- start the reactor
RESET_RPS = 2, -- reset the RPS
SET_BURN = 3, -- set the burn rate
SET_WASTE = 4, -- set the waste processing mode
ACK_ALL_ALARMS = 5, -- ack all active alarms
ACK_ALARM = 6, -- ack a particular alarm
RESET_ALARM = 7, -- reset a particular alarm
SET_GROUP = 8 -- assign this unit to a group
SCRAM = 0, -- SCRAM the reactor
START = 1, -- start the reactor
RESET_RPS = 2, -- reset the RPS
SET_BURN = 3, -- set the burn rate
SET_WASTE = 4, -- set the waste processing mode
ACK_ALL_ALARMS = 5, -- ack all active alarms
ACK_ALARM = 6, -- ack a particular alarm
RESET_ALARM = 7, -- reset a particular alarm
SET_GROUP = 8 -- assign this unit to a group
}
comms.PROTOCOL = PROTOCOL
@ -147,6 +150,7 @@ function comms.scada_packet()
local self = {
modem_msg_in = nil, ---@type modem_message|nil
valid = false,
authenticated = false,
raw = {},
src_addr = comms.BROADCAST,
dest_addr = comms.BROADCAST,
@ -235,6 +239,9 @@ function comms.scada_packet()
return self.valid
end
-- report that this packet has been authenticated (was received with a valid HMAC)
function public.stamp_authenticated() self.authenticated = true end
-- public accessors --
---@nodiscard
@ -249,6 +256,8 @@ function comms.scada_packet()
---@nodiscard
function public.is_valid() return self.valid end
---@nodiscard
function public.is_authenticated() return self.authenticated end
---@nodiscard
function public.src_addr() return self.src_addr end
@ -590,7 +599,10 @@ function comms.mgmt_packet()
self.type == SCADA_MGMT_TYPE.REMOTE_LINKED or
self.type == SCADA_MGMT_TYPE.RTU_ADVERT or
self.type == SCADA_MGMT_TYPE.RTU_DEV_REMOUNT or
self.type == SCADA_MGMT_TYPE.RTU_TONE_ALARM
self.type == SCADA_MGMT_TYPE.RTU_TONE_ALARM or
self.type == SCADA_MGMT_TYPE.DIAG_TONE_GET or
self.type == SCADA_MGMT_TYPE.DIAG_TONE_SET or
self.type == SCADA_MGMT_TYPE.DIAG_ALARM_SET
end
-- make a SCADA management packet

View File

@ -212,6 +212,7 @@ function network.nic(modem)
if packet_hmac == computed_hmac then
-- log.debug("crypto.modem.receive: HMAC verified in " .. (util.time_ms() - start) .. "ms")
s_packet.receive(side, sender, reply_to, textutils.unserialize(msg), distance)
s_packet.stamp_authenticated()
else
-- log.debug("crypto.modem.receive: HMAC failed verification in " .. (util.time_ms() - start) .. "ms")
end

View File

@ -9,16 +9,16 @@ local unit = require("supervisor.unit")
local rsctl = require("supervisor.session.rsctl")
local TONES = audio.TONES
local TONES = audio.TONES
local ALARM = types.ALARM
local PRIO = types.ALARM_PRIORITY
local ALARM_STATE = types.ALARM_STATE
local PROCESS = types.PROCESS
local PROCESS_NAMES = types.PROCESS_NAMES
local PRIO = types.ALARM_PRIORITY
local ALARM = types.ALARM
local ALARM_STATE = types.ALARM_STATE
local RTU_UNIT_TYPE = types.RTU_UNIT_TYPE
local WASTE = types.WASTE_PRODUCT
local WASTE_MODE = types.WASTE_MODE
local WASTE = types.WASTE_PRODUCT
local IO = rsio.IO
@ -65,6 +65,7 @@ function facility.new(num_reactors, cooling_conf)
units = {},
status_text = { "START UP", "initializing..." },
all_sys_ok = false,
allow_testing = false,
-- rtus
rtu_conn_count = 0,
rtu_list = {},
@ -115,7 +116,11 @@ function facility.new(num_reactors, cooling_conf)
current_waste_product = WASTE.PLUTONIUM,
pu_fallback = false,
-- alarm tones
tone_states = { false, false, false, false, false, false, false, false },
tone_states = {},
test_tone_set = false,
test_tone_reset = false,
test_tone_states = {},
test_alarm_states = {},
-- statistics
im_stat_init = false,
avg_charge = util.mov_avg(3, 0.0),
@ -135,6 +140,13 @@ function facility.new(num_reactors, cooling_conf)
-- init redstone RTU I/O controller
self.io_ctl = rsctl.new(self.redstone)
-- fill blank alarm/tone states
for _ = 1, 12 do table.insert(self.test_alarm_states, false) end
for _ = 1, 8 do
table.insert(self.tone_states, false)
table.insert(self.test_tone_states, false)
end
-- check if all auto-controlled units completed ramping
---@nodiscard
local function _all_units_ramped()
@ -269,15 +281,20 @@ function facility.new(num_reactors, cooling_conf)
-- supervisor sessions reporting the list of active RTU sessions
---@param rtu_sessions table session list of all connected RTUs
function public.report_rtus(rtu_sessions)
self.rtu_conn_count = #rtu_sessions
end
function public.report_rtus(rtu_sessions) self.rtu_conn_count = #rtu_sessions end
-- update (iterate) the facility management
function public.update()
-- unlink RTU unit sessions if they are closed
for _, v in pairs(self.rtu_list) do util.filter_table(v, function (u) return u.is_connected() end) end
-- check if test routines are allowed right now
self.allow_testing = true
for i = 1, #self.units do
local u = self.units[i] ---@type reactor_unit
self.allow_testing = self.allow_testing and u.is_safe_idle()
end
-- current state for process control
local charge_update = 0
local rate_update = 0
@ -762,17 +779,43 @@ function facility.new(num_reactors, cooling_conf)
-- Update Alarm Tones --
------------------------
local alarms = { false, false, false, false, false, false, false, false, false, false, false, false }
self.tone_states = { false, false, false, false, false, false, false, false}
local allow_test = self.allow_testing and self.test_tone_set
-- check all alarms for all units
for i = 1, #self.units do
local u = self.units[i] ---@type reactor_unit
for id, alarm in pairs(u.get_alarms()) do
alarms[id] = alarms[id] or (alarm == ALARM_STATE.TRIPPED)
end
local alarms = { false, false, false, false, false, false, false, false, false, false, false, false }
for i = 1, #self.tone_states do
-- reset tone states before re-evaluting
self.tone_states[i] = false
-- clear testing tones if we aren't using them
if (not allow_test) and (not self.test_tone_reset) then self.test_tone_states[i] = false end
end
if allow_test then
alarms = self.test_alarm_states
else
-- check all alarms for all units
for i = 1, #self.units do
local u = self.units[i] ---@type reactor_unit
for id, alarm in pairs(u.get_alarms()) do
alarms[id] = alarms[id] or (alarm == ALARM_STATE.TRIPPED)
-- clear testing alarms if we aren't using them
if not self.test_tone_reset then self.test_alarm_states[id] = false end
end
end
self.test_tone_reset = true
end
-- flag that tones were reset to notify diagnostic accessor
if not allow_test then
self.test_tone_set = false
self.test_tone_reset = true
end
-- Evaluate Alarms --
-- containment breach is worst case CRITICAL alarm, this takes priority
if alarms[ALARM.ContainmentBreach] then
self.tone_states[TONES.T_1800Hz_Int_4Hz] = true
@ -815,6 +858,13 @@ function facility.new(num_reactors, cooling_conf)
self.tone_states[TONES.T_800Hz_Int] = false
self.tone_states[TONES.T_1000Hz_Int] = false
end
-- add to tone states if testing is active
if allow_test then
for i = 1, #self.tone_states do
self.tone_states[i] = self.tone_states[i] or self.test_tone_states[i]
end
end
end
-- call the update function of all units in the facility<br>
@ -956,6 +1006,46 @@ function facility.new(num_reactors, cooling_conf)
return self.pu_fallback
end
-- DIAGNOSTIC TESTING --
-- attempt to set a test tone state
---@param id tone_id|0 tone ID or 0 to disable all
---@param state boolean state
---@return boolean allow_testing, table test_tone_states
function public.diag_set_test_tone(id, state)
if self.allow_testing then
self.test_tone_set = true
self.test_tone_reset = false
if id == 0 then
for i = 1, #self.test_tone_states do self.test_tone_states[i] = false end
else
self.test_tone_states[id] = state
end
end
return self.allow_testing, self.test_tone_states
end
-- attempt to set a test alarm state
---@param id ALARM|0 alarm ID or 0 to disable all
---@param state boolean state
---@return boolean allow_testing, table test_alarm_states
function public.diag_set_test_alarm(id, state)
if self.allow_testing then
self.test_tone_set = true
self.test_tone_reset = false
if id == 0 then
for i = 1, #self.test_alarm_states do self.test_alarm_states[i] = false end
else
self.test_alarm_states[id] = state
end
end
return self.allow_testing, self.test_alarm_states
end
-- READ STATES/PROPERTIES --
-- get current alarm tone on/off states

View File

@ -33,8 +33,9 @@ local PERIODICS = {
---@param in_queue mqueue in message queue
---@param out_queue mqueue out message queue
---@param timeout number communications timeout
---@param facility facility facility data table
---@param fp_ok boolean if the front panel UI is running
function pocket.new_session(id, s_addr, in_queue, out_queue, timeout, fp_ok)
function pocket.new_session(id, s_addr, in_queue, out_queue, timeout, facility, fp_ok)
-- print a log message to the terminal as long as the UI isn't running
local function println(message) if not fp_ok then util.println_ts(message) end end
@ -129,6 +130,55 @@ function pocket.new_session(id, s_addr, in_queue, out_queue, timeout, fp_ok)
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
-- close the session
_close()
elseif pkt.type == SCADA_MGMT_TYPE.DIAG_TONE_GET then
-- get the state of alarm tones
_send_mgmt(SCADA_MGMT_TYPE.DIAG_TONE_GET, facility.get_alarm_tones())
elseif pkt.type == SCADA_MGMT_TYPE.DIAG_TONE_SET then
local valid = false
-- attempt to set a tone state
if pkt.scada_frame.is_authenticated() then
if pkt.length == 2 then
if type(pkt.data[1]) == "number" and type(pkt.data[2]) == "boolean" then
valid = true
-- try to set tone states, then send back if testing is allowed
local allow_testing, test_tone_states = facility.diag_set_test_tone(pkt.data[1], pkt.data[2])
_send_mgmt(SCADA_MGMT_TYPE.DIAG_TONE_SET, { allow_testing, test_tone_states })
else
log.debug(log_header .. "SCADA diag tone set packet data type mismatch")
end
else
log.debug(log_header .. "SCADA diag tone set packet length mismatch")
end
else
log.debug(log_header .. "DIAG_TONE_SET is blocked without HMAC for security")
end
if not valid then _send_mgmt(SCADA_MGMT_TYPE.DIAG_TONE_SET, { false }) end
elseif pkt.type == SCADA_MGMT_TYPE.DIAG_ALARM_SET then
local valid = false
-- attempt to set an alarm state
if pkt.scada_frame.is_authenticated() then
if pkt.length == 2 then
if type(pkt.data[1]) == "number" and type(pkt.data[2]) == "boolean" then
valid = true
-- try to set alarm states, then send back if testing is allowed
local allow_testing, test_alarm_states = facility.diag_set_test_alarm(pkt.data[1], pkt.data[2])
_send_mgmt(SCADA_MGMT_TYPE.DIAG_ALARM_SET, { allow_testing, test_alarm_states })
else
log.debug(log_header .. "SCADA diag alarm set packet data type mismatch")
end
else
log.debug(log_header .. "SCADA diag alarm set packet length mismatch")
end
else
log.debug(log_header .. "DIAG_ALARM_SET is blocked without HMAC for security")
end
if not valid then _send_mgmt(SCADA_MGMT_TYPE.DIAG_ALARM_SET, { false }) end
else
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
end

View File

@ -430,7 +430,8 @@ function svsessions.establish_pdg_session(source_addr, version)
local id = self.next_ids.pdg
pdg_s.instance = pocket.new_session(id, source_addr, pdg_s.in_queue, pdg_s.out_queue, config.PKT_TIMEOUT, self.fp_ok)
pdg_s.instance = pocket.new_session(id, source_addr, pdg_s.in_queue, pdg_s.out_queue, config.PKT_TIMEOUT, self.facility,
self.fp_ok)
table.insert(self.sessions.pdg, pdg_s)
local mt = {

View File

@ -21,7 +21,7 @@ local supervisor = require("supervisor.supervisor")
local svsessions = require("supervisor.session.svsessions")
local SUPERVISOR_VERSION = "v0.21.0"
local SUPERVISOR_VERSION = "v0.22.0"
local println = util.println
local println_ts = util.println_ts

View File

@ -719,6 +719,23 @@ function unit.new(reactor_id, num_boilers, num_turbines)
return false
end
-- check if the reactor is connected, is stopped, the RPS is not tripped, and no alarms are active
---@nodiscard
function public.is_safe_idle()
-- can't be disconnected
if self.plc_i == nil then return false end
-- alarms must be inactive and not tripping
for _, alarm in pairs(self.alarms) do
if not (alarm.state == AISTATE.INACTIVE or alarm.state == AISTATE.RING_BACK) then return false end
end
-- reactor must be stopped and RPS can't be tripped
if self.plc_i.get_status().status or self.plc_i.get_db().rps_tripped then return false end
return true
end
-- get build properties of machines
--
-- filter options