local comms = require("scada-common.comms")
|
|
local log = require("scada-common.log")
|
|
local mqueue = require("scada-common.mqueue")
|
|
local util = require("scada-common.util")
|
|
|
|
local databus = require("supervisor.databus")
|
|
|
|
local svqtypes = require("supervisor.session.svqtypes")
|
|
|
|
local coordinator = {}
|
|
|
|
local PROTOCOL = comms.PROTOCOL
|
|
local MGMT_TYPE = comms.MGMT_TYPE
|
|
local CRDN_TYPE = comms.CRDN_TYPE
|
|
local UNIT_COMMAND = comms.UNIT_COMMAND
|
|
local FAC_COMMAND = comms.FAC_COMMAND
|
|
|
|
local SV_Q_DATA = svqtypes.SV_Q_DATA
|
|
|
|
-- retry time constants in ms
|
|
-- local INITIAL_WAIT = 1500
|
|
local RETRY_PERIOD = 1000
|
|
local PARTIAL_RETRY_PERIOD = 2000
|
|
|
|
local CRD_S_CMDS = {
|
|
}
|
|
|
|
local CRD_S_DATA = {
|
|
CMD_ACK = 1,
|
|
RESEND_PLC_BUILD = 2,
|
|
RESEND_RTU_BUILD = 3
|
|
}
|
|
|
|
coordinator.CRD_S_CMDS = CRD_S_CMDS
|
|
coordinator.CRD_S_DATA = CRD_S_DATA
|
|
|
|
local PERIODICS = {
|
|
KEEP_ALIVE = 2000,
|
|
STATUS = 500
|
|
}
|
|
|
|
-- coordinator supervisor session
|
|
---@nodiscard
|
|
---@param id integer session ID
|
|
---@param s_addr integer device source address
|
|
---@param i_seq_num integer initial sequence number
|
|
---@param in_queue mqueue in message queue
|
|
---@param out_queue mqueue out message queue
|
|
---@param timeout number communications timeout
|
|
---@param facility facility facility data table
|
|
---@param fp_ok boolean if the front panel UI is running
|
|
function coordinator.new_session(id, s_addr, i_seq_num, in_queue, out_queue, timeout, facility, fp_ok)
|
|
-- print a log message to the terminal as long as the UI isn't running
|
|
local function println(message) if not fp_ok then util.println_ts(message) end end
|
|
|
|
local log_tag = "crdn_session(" .. id .. "): "
|
|
|
|
local self = {
|
|
units = facility.get_units(),
|
|
-- connection properties
|
|
seq_num = i_seq_num + 2, -- next after the establish approval was sent
|
|
r_seq_num = i_seq_num + 1,
|
|
connected = true,
|
|
conn_watchdog = util.new_watchdog(timeout),
|
|
establish_time = util.time_s(),
|
|
last_rtt = 0,
|
|
-- periodic messages
|
|
periodics = {
|
|
last_update = 0,
|
|
keep_alive = 0,
|
|
status_packet = 0
|
|
},
|
|
-- when to next retry one of these messages
|
|
retry_times = {
|
|
builds_packet = 0,
|
|
f_builds_packet = 0,
|
|
u_builds_packet = 0
|
|
},
|
|
-- message acknowledgements
|
|
acks = {
|
|
builds = false,
|
|
fac_builds = false,
|
|
unit_builds = false
|
|
}
|
|
}
|
|
|
|
-- mark this coordinator session as closed, stop watchdog
|
|
local function _close()
|
|
self.conn_watchdog.cancel()
|
|
self.connected = false
|
|
databus.tx_crd_disconnected()
|
|
end
|
|
|
|
-- send a CRDN packet
|
|
---@param msg_type CRDN_TYPE
|
|
---@param msg table
|
|
local function _send(msg_type, msg)
|
|
local s_pkt = comms.scada_packet()
|
|
local c_pkt = comms.crdn_packet()
|
|
|
|
c_pkt.make(msg_type, msg)
|
|
s_pkt.make(s_addr, self.seq_num, PROTOCOL.SCADA_CRDN, c_pkt.raw_sendable())
|
|
|
|
out_queue.push_packet(s_pkt)
|
|
self.seq_num = self.seq_num + 1
|
|
end
|
|
|
|
-- send a SCADA management packet
|
|
---@param msg_type MGMT_TYPE
|
|
---@param msg table
|
|
local function _send_mgmt(msg_type, msg)
|
|
local s_pkt = comms.scada_packet()
|
|
local m_pkt = comms.mgmt_packet()
|
|
|
|
m_pkt.make(msg_type, msg)
|
|
s_pkt.make(s_addr, self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
|
|
|
|
out_queue.push_packet(s_pkt)
|
|
self.seq_num = self.seq_num + 1
|
|
end
|
|
|
|
-- send both facility and unit builds
|
|
local function _send_all_builds()
|
|
local unit_builds = {}
|
|
|
|
for i = 1, #self.units do
|
|
local unit = self.units[i] ---@type reactor_unit
|
|
unit_builds[unit.get_id()] = unit.get_build()
|
|
end
|
|
|
|
_send(CRDN_TYPE.INITIAL_BUILDS, { facility.get_build(), unit_builds })
|
|
end
|
|
|
|
-- send facility builds
|
|
local function _send_fac_builds()
|
|
_send(CRDN_TYPE.FAC_BUILDS, { facility.get_build() })
|
|
end
|
|
|
|
-- send unit builds
|
|
local function _send_unit_builds()
|
|
local builds = {}
|
|
|
|
for i = 1, #self.units do
|
|
local unit = self.units[i] ---@type reactor_unit
|
|
builds[unit.get_id()] = unit.get_build()
|
|
end
|
|
|
|
_send(CRDN_TYPE.UNIT_BUILDS, { builds })
|
|
end
|
|
|
|
-- send facility status
|
|
local function _send_fac_status()
|
|
local status = {
|
|
facility.get_control_status(),
|
|
facility.get_rtu_statuses(),
|
|
facility.get_alarm_tones()
|
|
}
|
|
|
|
_send(CRDN_TYPE.FAC_STATUS, status)
|
|
end
|
|
|
|
-- send unit statuses
|
|
local function _send_unit_statuses()
|
|
local status = {}
|
|
|
|
for i = 1, #self.units do
|
|
local unit = self.units[i] ---@type reactor_unit
|
|
|
|
status[unit.get_id()] = {
|
|
unit.get_reactor_status(),
|
|
unit.get_rtu_statuses(),
|
|
unit.get_annunciator(),
|
|
unit.get_alarms(),
|
|
unit.get_state(),
|
|
unit.get_valves()
|
|
}
|
|
end
|
|
|
|
_send(CRDN_TYPE.UNIT_STATUSES, status)
|
|
end
|
|
|
|
-- handle a packet
|
|
---@param pkt mgmt_frame|crdn_frame
|
|
local function _handle_packet(pkt)
|
|
-- check sequence number
|
|
if self.r_seq_num ~= pkt.scada_frame.seq_num() then
|
|
log.warning(log_tag .. "sequence out-of-order: next = " .. self.r_seq_num .. ", new = " .. pkt.scada_frame.seq_num())
|
|
return
|
|
else
|
|
self.r_seq_num = pkt.scada_frame.seq_num() + 1
|
|
end
|
|
|
|
-- feed watchdog
|
|
self.conn_watchdog.feed()
|
|
|
|
-- process packet
|
|
if pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
|
|
---@cast pkt mgmt_frame
|
|
if pkt.type == MGMT_TYPE.KEEP_ALIVE then
|
|
-- keep alive reply
|
|
if pkt.length == 2 then
|
|
local srv_start = pkt.data[1]
|
|
-- local coord_send = pkt.data[2]
|
|
local srv_now = util.time()
|
|
self.last_rtt = srv_now - srv_start
|
|
|
|
if self.last_rtt > 750 then
|
|
log.warning(log_tag .. "COORD KEEP_ALIVE round trip time > 750ms (" .. self.last_rtt .. "ms)")
|
|
end
|
|
|
|
-- log.debug(log_header .. "COORD RTT = " .. self.last_rtt .. "ms")
|
|
-- log.debug(log_header .. "COORD TT = " .. (srv_now - coord_send) .. "ms")
|
|
|
|
databus.tx_crd_rtt(self.last_rtt)
|
|
else
|
|
log.debug(log_tag .. "SCADA keep alive packet length mismatch")
|
|
end
|
|
elseif pkt.type == MGMT_TYPE.CLOSE then
|
|
-- close the session
|
|
_close()
|
|
elseif pkt.type == MGMT_TYPE.ESTABLISH then
|
|
-- something is wrong, kill the session
|
|
_close()
|
|
log.warning(log_tag .. "terminated session due to an unexpected ESTABLISH packet")
|
|
else
|
|
log.debug(log_tag .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
|
|
end
|
|
elseif pkt.scada_frame.protocol() == PROTOCOL.SCADA_CRDN then
|
|
---@cast pkt crdn_frame
|
|
if pkt.type == CRDN_TYPE.INITIAL_BUILDS then
|
|
-- acknowledgement to coordinator receiving builds
|
|
self.acks.builds = true
|
|
elseif pkt.type == CRDN_TYPE.FAC_BUILDS then
|
|
-- acknowledgement to coordinator receiving builds
|
|
self.acks.fac_builds = true
|
|
elseif pkt.type == CRDN_TYPE.FAC_CMD then
|
|
if pkt.length >= 1 then
|
|
local cmd = pkt.data[1]
|
|
|
|
if cmd == FAC_COMMAND.SCRAM_ALL then
|
|
facility.scram_all()
|
|
_send(CRDN_TYPE.FAC_CMD, { cmd, true })
|
|
elseif cmd == FAC_COMMAND.STOP then
|
|
facility.auto_stop()
|
|
_send(CRDN_TYPE.FAC_CMD, { cmd, true })
|
|
elseif cmd == FAC_COMMAND.START then
|
|
if pkt.length == 6 then
|
|
---@type coord_auto_config
|
|
local config = {
|
|
mode = pkt.data[2],
|
|
burn_target = pkt.data[3],
|
|
charge_target = pkt.data[4],
|
|
gen_target = pkt.data[5],
|
|
limits = pkt.data[6]
|
|
}
|
|
|
|
_send(CRDN_TYPE.FAC_CMD, { cmd, table.unpack(facility.auto_start(config)) })
|
|
else
|
|
log.debug(log_tag .. "CRDN auto start (with configuration) packet length mismatch")
|
|
end
|
|
elseif cmd == FAC_COMMAND.ACK_ALL_ALARMS then
|
|
facility.ack_all()
|
|
_send(CRDN_TYPE.FAC_CMD, { cmd, true })
|
|
elseif cmd == FAC_COMMAND.SET_WASTE_MODE then
|
|
if pkt.length == 2 then
|
|
_send(CRDN_TYPE.FAC_CMD, { cmd, facility.set_waste_product(pkt.data[2]) })
|
|
else
|
|
log.debug(log_tag .. "CRDN set waste mode packet length mismatch")
|
|
end
|
|
elseif cmd == FAC_COMMAND.SET_PU_FB then
|
|
if pkt.length == 2 then
|
|
_send(CRDN_TYPE.FAC_CMD, { cmd, facility.set_pu_fallback(pkt.data[2]) })
|
|
else
|
|
log.debug(log_tag .. "CRDN set pu fallback packet length mismatch")
|
|
end
|
|
elseif cmd == FAC_COMMAND.SET_SPS_LP then
|
|
if pkt.length == 2 then
|
|
_send(CRDN_TYPE.FAC_CMD, { cmd, facility.set_sps_low_power(pkt.data[2]) })
|
|
else
|
|
log.debug(log_tag .. "CRDN set sps low power packet length mismatch")
|
|
end
|
|
else
|
|
log.debug(log_tag .. "CRDN facility command unknown")
|
|
end
|
|
else
|
|
log.debug(log_tag .. "CRDN facility command packet length mismatch")
|
|
end
|
|
elseif pkt.type == CRDN_TYPE.UNIT_BUILDS then
|
|
-- acknowledgement to coordinator receiving builds
|
|
self.acks.unit_builds = true
|
|
elseif pkt.type == CRDN_TYPE.UNIT_CMD then
|
|
if pkt.length >= 2 then
|
|
-- get command and unit id
|
|
local cmd = pkt.data[1]
|
|
local uid = pkt.data[2]
|
|
|
|
-- pkt.data[3] will be nil except for some commands
|
|
local data = { uid, pkt.data[3] }
|
|
|
|
-- continue if valid unit id
|
|
if util.is_int(uid) and uid > 0 and uid <= #self.units then
|
|
local unit = self.units[uid] ---@type reactor_unit
|
|
|
|
if cmd == UNIT_COMMAND.START then
|
|
out_queue.push_data(SV_Q_DATA.START, data)
|
|
elseif cmd == UNIT_COMMAND.SCRAM then
|
|
out_queue.push_data(SV_Q_DATA.SCRAM, data)
|
|
elseif cmd == UNIT_COMMAND.RESET_RPS then
|
|
out_queue.push_data(SV_Q_DATA.RESET_RPS, data)
|
|
elseif cmd == UNIT_COMMAND.SET_BURN then
|
|
if pkt.length == 3 then
|
|
out_queue.push_data(SV_Q_DATA.SET_BURN, data)
|
|
else
|
|
log.debug(log_tag .. "CRDN unit command burn rate missing option")
|
|
end
|
|
elseif cmd == UNIT_COMMAND.SET_WASTE then
|
|
if (pkt.length == 3) and (type(pkt.data[3]) == "number") and (pkt.data[3] > 0) and (pkt.data[3] <= 4) then
|
|
unit.set_waste_mode(pkt.data[3])
|
|
else
|
|
log.debug(log_tag .. "CRDN unit command set waste missing/invalid option")
|
|
end
|
|
elseif cmd == UNIT_COMMAND.ACK_ALL_ALARMS then
|
|
unit.ack_all()
|
|
_send(CRDN_TYPE.UNIT_CMD, { cmd, uid, true })
|
|
elseif cmd == UNIT_COMMAND.ACK_ALARM then
|
|
if pkt.length == 3 then
|
|
unit.ack_alarm(pkt.data[3])
|
|
else
|
|
log.debug(log_tag .. "CRDN unit command ack alarm missing alarm id")
|
|
end
|
|
elseif cmd == UNIT_COMMAND.RESET_ALARM then
|
|
if pkt.length == 3 then
|
|
unit.reset_alarm(pkt.data[3])
|
|
else
|
|
log.debug(log_tag .. "CRDN unit command reset alarm missing alarm id")
|
|
end
|
|
elseif cmd == UNIT_COMMAND.SET_GROUP then
|
|
if (pkt.length == 3) and (type(pkt.data[3]) == "number") and (pkt.data[3] >= 0) and (pkt.data[3] <= 4) then
|
|
facility.set_group(unit.get_id(), pkt.data[3])
|
|
_send(CRDN_TYPE.UNIT_CMD, { cmd, uid, pkt.data[3] })
|
|
else
|
|
log.debug(log_tag .. "CRDN unit command set group missing group id")
|
|
end
|
|
else
|
|
log.debug(log_tag .. "CRDN unit command unknown")
|
|
end
|
|
else
|
|
log.debug(log_tag .. "CRDN unit command invalid")
|
|
end
|
|
else
|
|
log.debug(log_tag .. "CRDN unit command packet length mismatch")
|
|
end
|
|
else
|
|
log.debug(log_tag .. "handler received unexpected SCADA_CRDN packet type " .. pkt.type)
|
|
end
|
|
end
|
|
end
|
|
|
|
---@class crd_session
|
|
local public = {}
|
|
|
|
-- get the session ID
|
|
---@nodiscard
|
|
function public.get_id() return id end
|
|
|
|
-- check if a timer matches this session's watchdog
|
|
---@nodiscard
|
|
function public.check_wd(timer)
|
|
return self.conn_watchdog.is_timer(timer) and self.connected
|
|
end
|
|
|
|
-- close the connection
|
|
function public.close()
|
|
_close()
|
|
_send_mgmt(MGMT_TYPE.CLOSE, {})
|
|
println("connection to coordinator " .. id .. " closed by server")
|
|
log.info(log_tag .. "session closed by server")
|
|
end
|
|
|
|
-- iterate the session
|
|
---@nodiscard
|
|
---@return boolean connected
|
|
function public.iterate()
|
|
if self.connected then
|
|
------------------
|
|
-- handle queue --
|
|
------------------
|
|
|
|
local handle_start = util.time()
|
|
|
|
while in_queue.ready() and self.connected do
|
|
-- get a new message to process
|
|
local message = in_queue.pop()
|
|
|
|
if message ~= nil then
|
|
if message.qtype == mqueue.TYPE.PACKET then
|
|
-- handle a packet
|
|
_handle_packet(message.message)
|
|
elseif message.qtype == mqueue.TYPE.COMMAND then
|
|
-- handle instruction
|
|
elseif message.qtype == mqueue.TYPE.DATA then
|
|
-- instruction with body
|
|
local cmd = message.message ---@type queue_data
|
|
|
|
if cmd.key == CRD_S_DATA.CMD_ACK then
|
|
local ack = cmd.val ---@type coord_ack
|
|
_send(CRDN_TYPE.UNIT_CMD, { ack.cmd, ack.unit, ack.ack })
|
|
elseif cmd.key == CRD_S_DATA.RESEND_PLC_BUILD then
|
|
-- re-send PLC build
|
|
-- retry logic will be kept as-is, so as long as no retry is needed, this will be a small update
|
|
self.retry_times.builds_packet = util.time() + PARTIAL_RETRY_PERIOD
|
|
self.acks.unit_builds = false
|
|
|
|
local unit_id = cmd.val
|
|
local builds = {}
|
|
|
|
local unit = self.units[unit_id] ---@type reactor_unit
|
|
builds[unit_id] = unit.get_build(-1)
|
|
|
|
_send(CRDN_TYPE.UNIT_BUILDS, { builds })
|
|
elseif cmd.key == CRD_S_DATA.RESEND_RTU_BUILD then
|
|
local unit_id = cmd.val.unit
|
|
if unit_id > 0 then
|
|
-- re-send unit RTU builds
|
|
-- retry logic will be kept as-is, so as long as no retry is needed, this will be a small update
|
|
self.retry_times.u_builds_packet = util.time() + PARTIAL_RETRY_PERIOD
|
|
self.acks.unit_builds = false
|
|
|
|
local builds = {}
|
|
|
|
local unit = self.units[unit_id] ---@type reactor_unit
|
|
builds[unit_id] = unit.get_build(cmd.val.type)
|
|
|
|
_send(CRDN_TYPE.UNIT_BUILDS, { builds })
|
|
else
|
|
-- re-send facility RTU builds
|
|
-- retry logic will be kept as-is, so as long as no retry is needed, this will be a small update
|
|
self.retry_times.f_builds_packet = util.time() + PARTIAL_RETRY_PERIOD
|
|
self.acks.fac_builds = false
|
|
|
|
_send(CRDN_TYPE.FAC_BUILDS, { facility.get_build(cmd.val.type) })
|
|
end
|
|
else
|
|
log.error(log_tag .. "unsupported data command received in in_queue (this is a bug)", true)
|
|
end
|
|
end
|
|
end
|
|
|
|
-- max 100ms spent processing queue
|
|
if util.time() - handle_start > 100 then
|
|
log.warning(log_tag .. "exceeded 100ms queue process limit")
|
|
break
|
|
end
|
|
end
|
|
|
|
-- exit if connection was closed
|
|
if not self.connected then
|
|
println("connection to coordinator closed by remote host")
|
|
log.info(log_tag .. "session closed by remote host")
|
|
return self.connected
|
|
end
|
|
|
|
----------------------
|
|
-- update periodics --
|
|
----------------------
|
|
|
|
local elapsed = util.time() - self.periodics.last_update
|
|
|
|
local periodics = self.periodics
|
|
|
|
-- keep alive
|
|
|
|
periodics.keep_alive = periodics.keep_alive + elapsed
|
|
if periodics.keep_alive >= PERIODICS.KEEP_ALIVE then
|
|
_send_mgmt(MGMT_TYPE.KEEP_ALIVE, { util.time() })
|
|
periodics.keep_alive = 0
|
|
end
|
|
|
|
-- statuses to coordinator
|
|
|
|
periodics.status_packet = periodics.status_packet + elapsed
|
|
if periodics.status_packet >= PERIODICS.STATUS then
|
|
_send_fac_status()
|
|
_send_unit_statuses()
|
|
periodics.status_packet = 0
|
|
end
|
|
|
|
self.periodics.last_update = util.time()
|
|
|
|
---------------------
|
|
-- attempt retries --
|
|
---------------------
|
|
|
|
local rtimes = self.retry_times
|
|
|
|
-- builds packet retries
|
|
|
|
if not self.acks.builds then
|
|
if rtimes.builds_packet - util.time() <= 0 then
|
|
_send_all_builds()
|
|
rtimes.builds_packet = util.time() + RETRY_PERIOD
|
|
end
|
|
end
|
|
|
|
if not self.acks.fac_builds then
|
|
if rtimes.f_builds_packet - util.time() <= 0 then
|
|
_send_fac_builds()
|
|
rtimes.f_builds_packet = util.time() + RETRY_PERIOD
|
|
end
|
|
end
|
|
|
|
if not self.acks.unit_builds then
|
|
if rtimes.u_builds_packet - util.time() <= 0 then
|
|
_send_unit_builds()
|
|
rtimes.u_builds_packet = util.time() + RETRY_PERIOD
|
|
end
|
|
end
|
|
end
|
|
|
|
return self.connected
|
|
end
|
|
|
|
return public
|
|
end
|
|
|
|