Go to file
2023-07-16 20:58:34 -04:00
.devcontainer added python to devcontainer and recommendations 2023-04-21 18:56:32 +00:00
.github unlikely to use ldoc due to incompatibilities with vscode lua extension luadocs 2023-06-08 11:39:07 -04:00
.vscode added python to devcontainer and recommendations 2023-04-21 18:56:32 +00:00
coordinator #272 basic dynamic tank data in supervisor and coordinator 2023-07-15 13:16:36 -04:00
graphics updated graphics comments 2023-07-09 23:42:44 -04:00
lockbox #51 include versioned lockbox in installer, reduced installer file size 2023-06-25 17:53:02 -04:00
pocket updated error messages for consistency 2023-07-11 15:15:44 -04:00
reactor-plc added high contrast yellow to rtu/plc/coord front panels 2023-07-12 13:38:37 -04:00
rtu removed unused fields from dynamic tank rtu 2023-07-13 12:19:25 -04:00
scada-common correctly print new messages without overwrites in dmesg even if a prior message is a progress one 2023-07-11 21:01:24 -04:00
supervisor removed unused variable 2023-07-15 13:33:18 -04:00
test updated lockbox benchmark 2023-06-26 20:44:55 -04:00
.gitignore #263 fixed bug with supervisor group map length not matching number of reactors 2023-06-18 15:19:01 -04:00
ccmsi.lua fixed installer clean bug 2023-07-16 20:58:34 -04:00
imgen.py #51 include versioned lockbox in installer, reduced installer file size 2023-06-25 17:53:02 -04:00
initenv.lua simplification of initenv file 2022-05-31 16:05:05 -04:00
install_manifest.json fixed installer clean bug 2023-07-16 20:58:34 -04:00
LICENSE updated license 2023-02-13 22:11:45 -05:00
README.md #276 updated readme 2023-06-29 16:54:46 -04:00
startup.lua added Luacheck GitHub action (#210) 2023-04-12 16:02:29 -04:00

cc-mek-scada

Configurable ComputerCraft SCADA system for multi-reactor control of Mekanism fission reactors with a GUI, automatic safety features, waste processing control, and more!

GitHub GitHub release (latest by date including pre-releases) GitHub Workflow Status (with branch) GitHub Workflow Status (with branch) GitHub Workflow Status (with branch)

Mod Requirements:

  • CC: Tweaked
  • Mekanism v10.1+

Mod Recommendations:

  • Advanced Peripherals (adds the capability to detect environmental radiation levels)

v10.1+ is required due the complete support of CC:Tweaked added in Mekanism v10.1

Released Component Versions

Core

Bootloader Comms

Utilities

Installer

Applications

Reactor PLC RTU Supervisor Coordinator Pocket

Installation

You can install this on a ComputerCraft computer using either:

  • wget https://raw.githubusercontent.com/MikaylaFischler/cc-mek-scada/main/ccmsi.lua
  • pastebin get tUVtJFxX ccmsi.lua

SCADA

Supervisory control and data acquisition (SCADA) is a control system architecture comprising computers, networked data communications and graphical user interfaces for high-level supervision of machines and processes. It also covers sensors and other devices, such as programmable logic controllers, which interface with process plant or machinery.

This project implements concepts of a SCADA system in ComputerCraft (because why not? ..okay don't answer that). I recommend reviewing that linked wikipedia page on SCADA if you want to understand the concepts used here.

Architecture

SCADA and industrial automation terminology is used throughout the project, such as:

  • Supervisory Computer: Gathers data and controls the process
  • Coordinating Computer: Used as the HMI component, user requests high-level processing operations
  • RTU: Remote Terminal Unit
  • PLC: Programmable Logic Controller

ComputerCraft Architecture

Coordinator Server

There can only be one of these. This server acts as a hybrid of levels 3 & 4 in the SCADA diagram above. In addition to viewing status and controlling processes with advanced monitors, it can host access for one or more Pocket computers.

Supervisory Computers

There should be one of these per facility system. Currently, that means only one. In the future, multiple supervisors would provide the capability of coordinating between multiple facilities (like a fission facility, fusion facility, etc).

RTUs

RTUs are effectively basic connections between a device and the SCADA system with no internal logic providing the system with I/O capabilities. A single Advanced Computer can represent multiple RTUs as instead I am modeling an RTU as the wired modems connected to that computer rather than the computer itself. Each RTU is referenced separately with an identifier in the modbus communications (see Communications section), so a single computer can distribute instructions to multiple devices. This should save on having a pile of computers everywhere (but if you want to have that, no one's stopping you).

The RTU control code is relatively unique, as instead of having instructions be decoded simply, due to using modbus, I implemented a generalized RTU interface. To fulfill this, each type of I/O operation is linked to a function rather than implementing the logic itself. For example, to connect an input register to a turbine getFlowRate() call, the function reference itself is passed to the connect_input_reg() function. A call to read_input_reg() on that register address will call the turbine.getFlowRate() function and return the result.

PLCs

PLCs are advanced devices that allow for both reporting and control to/from the SCADA system in addition to programed behaviors independent of the SCADA system. Currently there is only one type of PLC, and that is the reactor PLC. This is responsible for reporting on and controlling the reactor as a part of the SCADA system, and independently regulating the safety of the reactor. It checks the status for multiple hazard scenarios and shuts down the reactor if any condition is met.

There can and should only be one of these per reactor. A single Advanced Computer will act as the PLC, with either a direct connection (physical contact) or a wired modem connection to the reactor logic port.

Communications

A vaguely-modbus modbus communication protocol is used for communication with RTUs. Useful terminology for you to know:

  • Discrete Inputs: Single Bit Read-Only (digital inputs)
  • Coils: Single Bit Read/Write (digital I/O)
  • Input Registers: Multi-Byte Read-Only (analog inputs)
  • Holding Registers: Multi-Byte Read/Write (analog I/O)

Security

HMAC message authentication is available as a configuration option to prevent replay attacks and generally prevent control or false data reporting within a system's network. This is done utilizing the lua-lockbox project.

The other, simpler security feature is to enforce a maximum authorized transmission range, which is also a configurable feature on each device.