local comms = require("scada-common.comms")
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local types = require("scada-common.types")
local util = require("scada-common.util")
local txnctrl = require("supervisor.session.rtu.txnctrl")
local unit_session = {}
local PROTOCOL = comms.PROTOCOL
local MODBUS_FCODE = types.MODBUS_FCODE
local MODBUS_EXCODE = types.MODBUS_EXCODE
local RTU_US_CMDS = {
}
local RTU_US_DATA = {
BUILD_CHANGED = 1
}
unit_session.RTU_US_CMDS = RTU_US_CMDS
unit_session.RTU_US_DATA = RTU_US_DATA
-- create a new unit session runner
---@param session_id integer RTU session ID
---@param unit_id integer MODBUS unit ID
---@param advert rtu_advertisement RTU advertisement for this unit
---@param out_queue mqueue send queue
---@param log_tag string logging tag
---@param txn_tags table transaction log tags
function unit_session.new(session_id, unit_id, advert, out_queue, log_tag, txn_tags)
local self = {
log_tag = log_tag,
txn_tags = txn_tags,
unit_id = unit_id,
device_index = advert.index,
reactor = advert.reactor,
out_q = out_queue,
transaction_controller = txnctrl.new(),
connected = true,
device_fail = false
}
---@class _unit_session
local protected = {
in_q = mqueue.new()
}
---@class unit_session
local public = {}
-- PROTECTED FUNCTIONS --
-- send a MODBUS message, creating a transaction in the process
---@param txn_type integer transaction type
---@param f_code MODBUS_FCODE function code
---@param register_param table register range or register and values
---@return integer txn_id transaction ID of this transaction
function protected.send_request(txn_type, f_code, register_param)
local m_pkt = comms.modbus_packet()
local txn_id = self.transaction_controller.create(txn_type)
m_pkt.make(txn_id, self.unit_id, f_code, register_param)
self.out_q.push_packet(m_pkt)
return txn_id
end
-- try to resolve a MODBUS transaction
---@param m_pkt modbus_frame MODBUS packet
---@return integer|false txn_type, integer txn_id transaction type or false on error/busy, transaction ID
function protected.try_resolve(m_pkt)
if m_pkt.scada_frame.protocol() == PROTOCOL.MODBUS_TCP then
if m_pkt.unit_id == self.unit_id then
local txn_type = self.transaction_controller.resolve(m_pkt.txn_id)
local txn_tag = " (" .. util.strval(self.txn_tags[txn_type]) .. ")"
if bit.band(m_pkt.func_code, MODBUS_FCODE.ERROR_FLAG) ~= 0 then
-- transaction incomplete or failed
local ex = m_pkt.data[1]
if ex == MODBUS_EXCODE.ILLEGAL_FUNCTION then
log.error(log_tag .. "MODBUS: illegal function" .. txn_tag)
elseif ex == MODBUS_EXCODE.ILLEGAL_DATA_ADDR then
log.error(log_tag .. "MODBUS: illegal data address" .. txn_tag)
elseif ex == MODBUS_EXCODE.SERVER_DEVICE_FAIL then
if self.device_fail then
log.debug(log_tag .. "MODBUS: repeated device failure" .. txn_tag)
else
self.device_fail = true
log.warning(log_tag .. "MODBUS: device failure" .. txn_tag)
end
elseif ex == MODBUS_EXCODE.ACKNOWLEDGE then
-- will have to wait on reply, renew the transaction
self.transaction_controller.renew(m_pkt.txn_id, txn_type)
elseif ex == MODBUS_EXCODE.SERVER_DEVICE_BUSY then
-- will have to wait on reply, renew the transaction
self.transaction_controller.renew(m_pkt.txn_id, txn_type)
log.debug(log_tag .. "MODBUS: device busy" .. txn_tag)
elseif ex == MODBUS_EXCODE.NEG_ACKNOWLEDGE then
-- general failure
log.error(log_tag .. "MODBUS: negative acknowledge (bad request)" .. txn_tag)
elseif ex == MODBUS_EXCODE.GATEWAY_PATH_UNAVAILABLE then
-- RTU gateway has no known unit with the given ID
log.error(log_tag .. "MODBUS: gateway path unavailable (unknown unit)" .. txn_tag)
elseif ex ~= nil then
-- unsupported exception code
log.debug(log_tag .. "MODBUS: unsupported error " .. ex .. txn_tag)
else
-- nil exception code
log.debug(log_tag .. "MODBUS: nil exception code" .. txn_tag)
end
else
-- clear device fail flag
self.device_fail = false
-- no error, return the transaction type
return txn_type, m_pkt.txn_id
end
else
log.error(log_tag .. "wrong unit ID: " .. m_pkt.unit_id, true)
end
else
log.error(log_tag .. "illegal packet type " .. m_pkt.scada_frame.protocol(), true)
end
-- error or transaction in progress, return false
return false, m_pkt.txn_id
end
-- post update tasks
function protected.post_update()
self.transaction_controller.cleanup()
end
-- get the public interface
function protected.get() return public end
-- PUBLIC FUNCTIONS --
-- get the unit ID
function public.get_session_id() return session_id end
-- get the unit ID
function public.get_unit_id() return self.unit_id end
-- get the device index
function public.get_device_idx() return self.device_index end
-- get the reactor ID
function public.get_reactor() return self.reactor end
-- get the command queue
function public.get_cmd_queue() return protected.in_q end
-- close this unit
function public.close() self.connected = false end
-- check if this unit is connected
function public.is_connected() return self.connected end
-- check if this unit is faulted
function public.is_faulted() return self.device_fail end
-- PUBLIC TEMPLATE FUNCTIONS --
-- handle a packet
---@param m_pkt modbus_frame
---@diagnostic disable-next-line: unused-local
function public.handle_packet(m_pkt)
log.debug("template unit_session.handle_packet() called", true)
end
-- update this runner
---@param time_now integer milliseconds
---@diagnostic disable-next-line: unused-local
function public.update(time_now)
log.debug("template unit_session.update() called", true)
end
-- invalidate build cache
function public.invalidate_cache()
log.debug("template unit_session.invalidate_cache() called", true)
end
-- get the unit session database
function public.get_db()
log.debug("template unit_session.get_db() called", true)
return {}
end
return protected
end
return unit_session