#118 refactoring of comms types

This commit is contained in:
Mikayla Fischler 2023-02-21 11:05:57 -05:00
parent 34cac6a8b8
commit 6e0dde3f30
20 changed files with 354 additions and 357 deletions

View File

@ -14,13 +14,13 @@ local println = util.println
local print_ts = util.print_ts
local println_ts = util.println_ts
local PROTOCOLS = comms.PROTOCOLS
local DEVICE_TYPES = comms.DEVICE_TYPES
local PROTOCOL = comms.PROTOCOL
local DEVICE_TYPE = comms.DEVICE_TYPE
local ESTABLISH_ACK = comms.ESTABLISH_ACK
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
local SCADA_CRDN_TYPES = comms.SCADA_CRDN_TYPES
local UNIT_COMMANDS = comms.UNIT_COMMANDS
local FAC_COMMANDS = comms.FAC_COMMANDS
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local SCADA_CRDN_TYPE = comms.SCADA_CRDN_TYPE
local UNIT_COMMAND = comms.UNIT_COMMAND
local FAC_COMMAND = comms.FAC_COMMAND
local coordinator = {}
@ -225,15 +225,15 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
_conf_channels()
-- send a packet to the supervisor
---@param msg_type SCADA_MGMT_TYPES|SCADA_CRDN_TYPES
---@param msg_type SCADA_MGMT_TYPE|SCADA_CRDN_TYPE
---@param msg table
local function _send_sv(protocol, msg_type, msg)
local s_pkt = comms.scada_packet()
local pkt = nil ---@type mgmt_packet|crdn_packet
if protocol == PROTOCOLS.SCADA_MGMT then
if protocol == PROTOCOL.SCADA_MGMT then
pkt = comms.mgmt_packet()
elseif protocol == PROTOCOLS.SCADA_CRDN then
elseif protocol == PROTOCOL.SCADA_CRDN then
pkt = comms.crdn_packet()
else
return
@ -248,13 +248,13 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
-- attempt connection establishment
local function _send_establish()
_send_sv(PROTOCOLS.SCADA_MGMT, SCADA_MGMT_TYPES.ESTABLISH, { comms.version, version, DEVICE_TYPES.CRDN })
_send_sv(PROTOCOL.SCADA_MGMT, SCADA_MGMT_TYPE.ESTABLISH, { comms.version, version, DEVICE_TYPE.CRDN })
end
-- keep alive ack
---@param srv_time integer
local function _send_keep_alive_ack(srv_time)
_send_sv(PROTOCOLS.SCADA_MGMT, SCADA_MGMT_TYPES.KEEP_ALIVE, { srv_time, util.time() })
_send_sv(PROTOCOL.SCADA_MGMT, SCADA_MGMT_TYPE.KEEP_ALIVE, { srv_time, util.time() })
end
-- PUBLIC FUNCTIONS --
@ -271,7 +271,7 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
function public.close()
sv_watchdog.cancel()
self.sv_linked = false
_send_sv(PROTOCOLS.SCADA_MGMT, SCADA_MGMT_TYPES.CLOSE, {})
_send_sv(PROTOCOL.SCADA_MGMT, SCADA_MGMT_TYPE.CLOSE, {})
end
-- attempt to connect to the subervisor
@ -300,7 +300,7 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
elseif event == "modem_message" then
-- handle message
local packet = public.parse_packet(p1, p2, p3, p4, p5)
if packet ~= nil and packet.type == SCADA_MGMT_TYPES.ESTABLISH then
if packet ~= nil and packet.type == SCADA_MGMT_TYPE.ESTABLISH then
public.handle_packet(packet)
end
elseif event == "terminate" then
@ -329,25 +329,25 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
end
-- send a facility command
---@param cmd FAC_COMMANDS command
---@param cmd FAC_COMMAND command
function public.send_fac_command(cmd)
_send_sv(PROTOCOLS.SCADA_CRDN, SCADA_CRDN_TYPES.FAC_CMD, { cmd })
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.FAC_CMD, { cmd })
end
-- send the auto process control configuration with a start command
---@param config coord_auto_config configuration
function public.send_auto_start(config)
_send_sv(PROTOCOLS.SCADA_CRDN, SCADA_CRDN_TYPES.FAC_CMD, {
FAC_COMMANDS.START, config.mode, config.burn_target, config.charge_target, config.gen_target, config.limits
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.FAC_CMD, {
FAC_COMMAND.START, config.mode, config.burn_target, config.charge_target, config.gen_target, config.limits
})
end
-- send a unit command
---@param cmd UNIT_COMMANDS command
---@param cmd UNIT_COMMAND command
---@param unit integer unit ID
---@param option any? optional option options for the optional options (like burn rate) (does option still look like a word?)
function public.send_unit_command(cmd, unit, option)
_send_sv(PROTOCOLS.SCADA_CRDN, SCADA_CRDN_TYPES.UNIT_CMD, { cmd, unit, option })
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.UNIT_CMD, { cmd, unit, option })
end
-- parse a packet
@ -366,19 +366,19 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
if s_pkt.is_valid() then
-- get as SCADA management packet
if s_pkt.protocol() == PROTOCOLS.SCADA_MGMT then
if s_pkt.protocol() == PROTOCOL.SCADA_MGMT then
local mgmt_pkt = comms.mgmt_packet()
if mgmt_pkt.decode(s_pkt) then
pkt = mgmt_pkt.get()
end
-- get as coordinator packet
elseif s_pkt.protocol() == PROTOCOLS.SCADA_CRDN then
elseif s_pkt.protocol() == PROTOCOL.SCADA_CRDN then
local crdn_pkt = comms.crdn_packet()
if crdn_pkt.decode(s_pkt) then
pkt = crdn_pkt.get()
end
-- get as coordinator API packet
elseif s_pkt.protocol() == PROTOCOLS.COORD_API then
elseif s_pkt.protocol() == PROTOCOL.COORD_API then
local capi_pkt = comms.capi_packet()
if capi_pkt.decode(s_pkt) then
pkt = capi_pkt.get()
@ -399,7 +399,7 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
local l_port = packet.scada_frame.local_port()
if l_port == api_listen then
if protocol == PROTOCOLS.COORD_API then
if protocol == PROTOCOL.COORD_API then
---@diagnostic disable-next-line: param-type-mismatch
apisessions.handle_packet(packet)
else
@ -420,9 +420,9 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
sv_watchdog.feed()
-- handle packet
if protocol == PROTOCOLS.SCADA_CRDN then
if protocol == PROTOCOL.SCADA_CRDN then
if self.sv_linked then
if packet.type == SCADA_CRDN_TYPES.INITIAL_BUILDS then
if packet.type == SCADA_CRDN_TYPE.INITIAL_BUILDS then
if packet.length == 2 then
-- record builds
local fac_builds = iocontrol.record_facility_builds(packet.data[1])
@ -430,47 +430,47 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
if fac_builds and unit_builds then
-- acknowledge receipt of builds
_send_sv(PROTOCOLS.SCADA_CRDN, SCADA_CRDN_TYPES.INITIAL_BUILDS, {})
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.INITIAL_BUILDS, {})
else
log.error("received invalid INITIAL_BUILDS packet")
end
else
log.debug("INITIAL_BUILDS packet length mismatch")
end
elseif packet.type == SCADA_CRDN_TYPES.FAC_BUILDS then
elseif packet.type == SCADA_CRDN_TYPE.FAC_BUILDS then
if packet.length == 1 then
-- record facility builds
if iocontrol.record_facility_builds(packet.data[1]) then
-- acknowledge receipt of builds
_send_sv(PROTOCOLS.SCADA_CRDN, SCADA_CRDN_TYPES.FAC_BUILDS, {})
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.FAC_BUILDS, {})
else
log.error("received invalid FAC_BUILDS packet")
end
else
log.debug("FAC_BUILDS packet length mismatch")
end
elseif packet.type == SCADA_CRDN_TYPES.FAC_STATUS then
elseif packet.type == SCADA_CRDN_TYPE.FAC_STATUS then
-- update facility status
if not iocontrol.update_facility_status(packet.data) then
log.error("received invalid FAC_STATUS packet")
end
elseif packet.type == SCADA_CRDN_TYPES.FAC_CMD then
elseif packet.type == SCADA_CRDN_TYPE.FAC_CMD then
-- facility command acknowledgement
if packet.length >= 2 then
local cmd = packet.data[1]
local ack = packet.data[2] == true
if cmd == FAC_COMMANDS.SCRAM_ALL then
if cmd == FAC_COMMAND.SCRAM_ALL then
iocontrol.get_db().facility.scram_ack(ack)
elseif cmd == FAC_COMMANDS.STOP then
elseif cmd == FAC_COMMAND.STOP then
iocontrol.get_db().facility.stop_ack(ack)
elseif cmd == FAC_COMMANDS.START then
elseif cmd == FAC_COMMAND.START then
if packet.length == 7 then
process.start_ack_handle({ table.unpack(packet.data, 2) })
else
log.debug("SCADA_CRDN process start (with configuration) ack echo packet length mismatch")
end
elseif cmd == FAC_COMMANDS.ACK_ALL_ALARMS then
elseif cmd == FAC_COMMAND.ACK_ALL_ALARMS then
iocontrol.get_db().facility.ack_alarms_ack(ack)
else
log.debug(util.c("received facility command ack with unknown command ", cmd))
@ -478,24 +478,24 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
else
log.debug("SCADA_CRDN facility command ack packet length mismatch")
end
elseif packet.type == SCADA_CRDN_TYPES.UNIT_BUILDS then
elseif packet.type == SCADA_CRDN_TYPE.UNIT_BUILDS then
-- record builds
if packet.length == 1 then
if iocontrol.record_unit_builds(packet.data[1]) then
-- acknowledge receipt of builds
_send_sv(PROTOCOLS.SCADA_CRDN, SCADA_CRDN_TYPES.UNIT_BUILDS, {})
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.UNIT_BUILDS, {})
else
log.error("received invalid UNIT_BUILDS packet")
end
else
log.debug("UNIT_BUILDS packet length mismatch")
end
elseif packet.type == SCADA_CRDN_TYPES.UNIT_STATUSES then
elseif packet.type == SCADA_CRDN_TYPE.UNIT_STATUSES then
-- update statuses
if not iocontrol.update_unit_statuses(packet.data) then
log.error("received invalid UNIT_STATUSES packet")
end
elseif packet.type == SCADA_CRDN_TYPES.UNIT_CMD then
elseif packet.type == SCADA_CRDN_TYPE.UNIT_CMD then
-- unit command acknowledgement
if packet.length == 3 then
local cmd = packet.data[1]
@ -505,19 +505,19 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
local unit = iocontrol.get_db().units[unit_id] ---@type ioctl_unit
if unit ~= nil then
if cmd == UNIT_COMMANDS.SCRAM then
if cmd == UNIT_COMMAND.SCRAM then
unit.scram_ack(ack)
elseif cmd == UNIT_COMMANDS.START then
elseif cmd == UNIT_COMMAND.START then
unit.start_ack(ack)
elseif cmd == UNIT_COMMANDS.RESET_RPS then
elseif cmd == UNIT_COMMAND.RESET_RPS then
unit.reset_rps_ack(ack)
elseif cmd == UNIT_COMMANDS.SET_BURN then
elseif cmd == UNIT_COMMAND.SET_BURN then
unit.set_burn_ack(ack)
elseif cmd == UNIT_COMMANDS.SET_WASTE then
elseif cmd == UNIT_COMMAND.SET_WASTE then
unit.set_waste_ack(ack)
elseif cmd == UNIT_COMMANDS.ACK_ALL_ALARMS then
elseif cmd == UNIT_COMMAND.ACK_ALL_ALARMS then
unit.ack_alarms_ack(ack)
elseif cmd == UNIT_COMMANDS.SET_GROUP then
elseif cmd == UNIT_COMMAND.SET_GROUP then
---@todo how is this going to be handled?
else
log.debug(util.c("received unit command ack with unknown command ", cmd))
@ -534,8 +534,8 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
else
log.debug("discarding SCADA_CRDN packet before linked")
end
elseif protocol == PROTOCOLS.SCADA_MGMT then
if packet.type == SCADA_MGMT_TYPES.ESTABLISH then
elseif protocol == PROTOCOL.SCADA_MGMT then
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- connection with supervisor established
if packet.length == 2 then
local est_ack = packet.data[1]
@ -596,7 +596,7 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
log.debug("SCADA_MGMT establish packet length mismatch")
end
elseif self.sv_linked then
if packet.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 then
local timestamp = packet.data[1]
@ -614,7 +614,7 @@ function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range
else
log.debug("SCADA keep alive packet length mismatch")
end
elseif packet.type == SCADA_MGMT_TYPES.CLOSE then
elseif packet.type == SCADA_MGMT_TYPE.CLOSE then
-- handle session close
sv_watchdog.cancel()
self.sv_linked = false

View File

@ -1,4 +1,3 @@
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local psil = require("scada-common.psil")
local types = require("scada-common.types")
@ -7,8 +6,6 @@ local util = require("scada-common.util")
local process = require("coordinator.process")
local sounder = require("coordinator.sounder")
local UNIT_COMMANDS = comms.UNIT_COMMANDS
local ALARM_STATE = types.ALARM_STATE
local iocontrol = {}

View File

@ -4,8 +4,8 @@ local log = require("scada-common.log")
local types = require("scada-common.types")
local util = require("scada-common.util")
local FAC_COMMANDS = comms.FAC_COMMANDS
local UNIT_COMMANDS = comms.UNIT_COMMANDS
local FAC_COMMAND = comms.FAC_COMMAND
local UNIT_COMMAND = comms.UNIT_COMMAND
local PROCESS = types.PROCESS
@ -71,7 +71,7 @@ function process.init(iocontrol, comms)
if type(waste_mode) == "table" then
for id, mode in pairs(waste_mode) do
self.comms.send_unit_command(UNIT_COMMANDS.SET_WASTE, id, mode)
self.comms.send_unit_command(UNIT_COMMAND.SET_WASTE, id, mode)
end
log.info("PROCESS: loaded waste mode settings from coord.settings")
@ -81,7 +81,7 @@ function process.init(iocontrol, comms)
if type(prio_groups) == "table" then
for id, group in pairs(prio_groups) do
self.comms.send_unit_command(UNIT_COMMANDS.SET_GROUP, id, group)
self.comms.send_unit_command(UNIT_COMMAND.SET_GROUP, id, group)
end
log.info("PROCESS: loaded priority groups settings from coord.settings")
@ -90,13 +90,13 @@ end
-- facility SCRAM command
function process.fac_scram()
self.comms.send_fac_command(FAC_COMMANDS.SCRAM_ALL)
self.comms.send_fac_command(FAC_COMMAND.SCRAM_ALL)
log.debug("FAC: SCRAM ALL")
end
-- facility alarm acknowledge command
function process.fac_ack_alarms()
self.comms.send_fac_command(FAC_COMMANDS.ACK_ALL_ALARMS)
self.comms.send_fac_command(FAC_COMMAND.ACK_ALL_ALARMS)
log.debug("FAC: ACK ALL ALARMS")
end
@ -104,7 +104,7 @@ end
---@param id integer unit ID
function process.start(id)
self.io.units[id].control_state = true
self.comms.send_unit_command(UNIT_COMMANDS.START, id)
self.comms.send_unit_command(UNIT_COMMAND.START, id)
log.debug(util.c("UNIT[", id, "]: START"))
end
@ -112,14 +112,14 @@ end
---@param id integer unit ID
function process.scram(id)
self.io.units[id].control_state = false
self.comms.send_unit_command(UNIT_COMMANDS.SCRAM, id)
self.comms.send_unit_command(UNIT_COMMAND.SCRAM, id)
log.debug(util.c("UNIT[", id, "]: SCRAM"))
end
-- reset reactor protection system
---@param id integer unit ID
function process.reset_rps(id)
self.comms.send_unit_command(UNIT_COMMANDS.RESET_RPS, id)
self.comms.send_unit_command(UNIT_COMMAND.RESET_RPS, id)
log.debug(util.c("UNIT[", id, "]: RESET RPS"))
end
@ -127,7 +127,7 @@ end
---@param id integer unit ID
---@param rate number burn rate
function process.set_rate(id, rate)
self.comms.send_unit_command(UNIT_COMMANDS.SET_BURN, id, rate)
self.comms.send_unit_command(UNIT_COMMAND.SET_BURN, id, rate)
log.debug(util.c("UNIT[", id, "]: SET BURN = ", rate))
end
@ -138,7 +138,7 @@ function process.set_waste(id, mode)
-- publish so that if it fails then it gets reset
self.io.units[id].unit_ps.publish("U_WasteMode", mode)
self.comms.send_unit_command(UNIT_COMMANDS.SET_WASTE, id, mode)
self.comms.send_unit_command(UNIT_COMMAND.SET_WASTE, id, mode)
log.debug(util.c("UNIT[", id, "]: SET WASTE = ", mode))
local waste_mode = settings.get("WASTE_MODES") ---@type table|nil
@ -159,7 +159,7 @@ end
-- acknowledge all alarms
---@param id integer unit ID
function process.ack_all_alarms(id)
self.comms.send_unit_command(UNIT_COMMANDS.ACK_ALL_ALARMS, id)
self.comms.send_unit_command(UNIT_COMMAND.ACK_ALL_ALARMS, id)
log.debug(util.c("UNIT[", id, "]: ACK ALL ALARMS"))
end
@ -167,7 +167,7 @@ end
---@param id integer unit ID
---@param alarm integer alarm ID
function process.ack_alarm(id, alarm)
self.comms.send_unit_command(UNIT_COMMANDS.ACK_ALARM, id, alarm)
self.comms.send_unit_command(UNIT_COMMAND.ACK_ALARM, id, alarm)
log.debug(util.c("UNIT[", id, "]: ACK ALARM ", alarm))
end
@ -175,7 +175,7 @@ end
---@param id integer unit ID
---@param alarm integer alarm ID
function process.reset_alarm(id, alarm)
self.comms.send_unit_command(UNIT_COMMANDS.RESET_ALARM, id, alarm)
self.comms.send_unit_command(UNIT_COMMAND.RESET_ALARM, id, alarm)
log.debug(util.c("UNIT[", id, "]: RESET ALARM ", alarm))
end
@ -183,7 +183,7 @@ end
---@param unit_id integer unit ID
---@param group_id integer|0 group ID or 0 for independent
function process.set_group(unit_id, group_id)
self.comms.send_unit_command(UNIT_COMMANDS.SET_GROUP, unit_id, group_id)
self.comms.send_unit_command(UNIT_COMMAND.SET_GROUP, unit_id, group_id)
log.debug(util.c("UNIT[", unit_id, "]: SET GROUP ", group_id))
local prio_groups = settings.get("PRIORITY_GROUPS") ---@type table|nil
@ -207,7 +207,7 @@ end
-- stop automatic process control
function process.stop_auto()
self.comms.send_fac_command(FAC_COMMANDS.STOP)
self.comms.send_fac_command(FAC_COMMAND.STOP)
log.debug("FAC: STOP AUTO")
end

View File

@ -8,11 +8,11 @@ local plc = {}
local rps_status_t = types.rps_status_t
local PROTOCOLS = comms.PROTOCOLS
local DEVICE_TYPES = comms.DEVICE_TYPES
local PROTOCOL = comms.PROTOCOL
local DEVICE_TYPE = comms.DEVICE_TYPE
local ESTABLISH_ACK = comms.ESTABLISH_ACK
local RPLC_TYPES = comms.RPLC_TYPES
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
local RPLC_TYPE = comms.RPLC_TYPE
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local AUTO_ACK = comms.PLC_AUTO_ACK
local print = util.print
@ -444,28 +444,28 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
_conf_channels()
-- send an RPLC packet
---@param msg_type RPLC_TYPES
---@param msg_type RPLC_TYPE
---@param msg table
local function _send(msg_type, msg)
local s_pkt = comms.scada_packet()
local r_pkt = comms.rplc_packet()
r_pkt.make(id, msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOLS.RPLC, r_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.RPLC, r_pkt.raw_sendable())
self.modem.transmit(self.s_port, self.l_port, s_pkt.raw_sendable())
self.seq_num = self.seq_num + 1
end
-- send a SCADA management packet
---@param msg_type SCADA_MGMT_TYPES
---@param msg_type SCADA_MGMT_TYPE
---@param msg table
local function _send_mgmt(msg_type, msg)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
self.modem.transmit(self.s_port, self.l_port, s_pkt.raw_sendable())
self.seq_num = self.seq_num + 1
@ -569,11 +569,11 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
-- keep alive ack
---@param srv_time integer
local function _send_keep_alive_ack(srv_time)
_send_mgmt(SCADA_MGMT_TYPES.KEEP_ALIVE, { srv_time, util.time() })
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { srv_time, util.time() })
end
-- general ack
---@param msg_type RPLC_TYPES
---@param msg_type RPLC_TYPE
---@param status boolean|integer
local function _send_ack(msg_type, status)
_send(msg_type, { status })
@ -605,7 +605,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
parallel.waitForAll(table.unpack(tasks))
if not self.reactor.__p_is_faulted() then
_send(RPLC_TYPES.MEK_STRUCT, mek_data)
_send(RPLC_TYPE.MEK_STRUCT, mek_data)
self.resend_build = false
else
log.error("failed to send structure: PPM fault")
@ -643,12 +643,12 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
function public.close()
conn_watchdog.cancel()
public.unlink()
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
end
-- attempt to establish link with supervisor
function public.send_link_req()
_send_mgmt(SCADA_MGMT_TYPES.ESTABLISH, { comms.version, version, DEVICE_TYPES.PLC, id })
_send_mgmt(SCADA_MGMT_TYPE.ESTABLISH, { comms.version, version, DEVICE_TYPE.PLC, id })
end
-- send live status information
@ -677,7 +677,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
mek_data -- mekanism status data
}
_send(RPLC_TYPES.STATUS, sys_status)
_send(RPLC_TYPE.STATUS, sys_status)
if self.resend_build then
_send_struct()
@ -688,7 +688,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
-- send reactor protection system status
function public.send_rps_status()
if self.linked then
_send(RPLC_TYPES.RPS_STATUS, { rps.is_tripped(), rps.get_trip_cause(), table.unpack(rps.status()) })
_send(RPLC_TYPE.RPS_STATUS, { rps.is_tripped(), rps.get_trip_cause(), table.unpack(rps.status()) })
end
end
@ -701,7 +701,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
table.unpack(rps.status())
}
_send(RPLC_TYPES.RPS_ALARM, rps_alarm)
_send(RPLC_TYPE.RPS_ALARM, rps_alarm)
end
end
@ -721,13 +721,13 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
if s_pkt.is_valid() then
-- get as RPLC packet
if s_pkt.protocol() == PROTOCOLS.RPLC then
if s_pkt.protocol() == PROTOCOL.RPLC then
local rplc_pkt = comms.rplc_packet()
if rplc_pkt.decode(s_pkt) then
pkt = rplc_pkt.get()
end
-- get as SCADA management packet
elseif s_pkt.protocol() == PROTOCOLS.SCADA_MGMT then
elseif s_pkt.protocol() == PROTOCOL.SCADA_MGMT then
local mgmt_pkt = comms.mgmt_packet()
if mgmt_pkt.decode(s_pkt) then
pkt = mgmt_pkt.get()
@ -762,18 +762,18 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
local protocol = packet.scada_frame.protocol()
-- handle packet
if protocol == PROTOCOLS.RPLC then
if protocol == PROTOCOL.RPLC then
if self.linked then
if packet.type == RPLC_TYPES.STATUS then
if packet.type == RPLC_TYPE.STATUS then
-- request of full status, clear cache first
self.status_cache = nil
public.send_status(plc_state.no_reactor, plc_state.reactor_formed)
log.debug("sent out status cache again, did supervisor miss it?")
elseif packet.type == RPLC_TYPES.MEK_STRUCT then
elseif packet.type == RPLC_TYPE.MEK_STRUCT then
-- request for physical structure
_send_struct()
log.debug("sent out structure again, did supervisor miss it?")
elseif packet.type == RPLC_TYPES.MEK_BURN_RATE then
elseif packet.type == RPLC_TYPE.MEK_BURN_RATE then
-- set the burn rate
if (packet.length == 2) and (type(packet.data[1]) == "number") then
local success = false
@ -805,29 +805,29 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
else
log.debug("RPLC set burn rate packet length mismatch or non-numeric burn rate")
end
elseif packet.type == RPLC_TYPES.RPS_ENABLE then
elseif packet.type == RPLC_TYPE.RPS_ENABLE then
-- enable the reactor
self.scrammed = false
_send_ack(packet.type, rps.activate())
elseif packet.type == RPLC_TYPES.RPS_SCRAM then
elseif packet.type == RPLC_TYPE.RPS_SCRAM then
-- disable the reactor per manual request
self.scrammed = true
rps.trip_manual()
_send_ack(packet.type, true)
elseif packet.type == RPLC_TYPES.RPS_ASCRAM then
elseif packet.type == RPLC_TYPE.RPS_ASCRAM then
-- disable the reactor per automatic request
self.scrammed = true
rps.trip_auto()
_send_ack(packet.type, true)
elseif packet.type == RPLC_TYPES.RPS_RESET then
elseif packet.type == RPLC_TYPE.RPS_RESET then
-- reset the RPS status
rps.reset()
_send_ack(packet.type, true)
elseif packet.type == RPLC_TYPES.RPS_AUTO_RESET then
elseif packet.type == RPLC_TYPE.RPS_AUTO_RESET then
-- reset automatic SCRAM and timeout trips
rps.auto_reset()
_send_ack(packet.type, true)
elseif packet.type == RPLC_TYPES.AUTO_BURN_RATE then
elseif packet.type == RPLC_TYPE.AUTO_BURN_RATE then
-- automatic control requested a new burn rate
if (packet.length == 3) and (type(packet.data[1]) == "number") and (type(packet.data[3]) == "number") then
local ack = AUTO_ACK.FAIL
@ -898,9 +898,9 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
else
log.debug("discarding RPLC packet before linked")
end
elseif protocol == PROTOCOLS.SCADA_MGMT then
elseif protocol == PROTOCOL.SCADA_MGMT then
if self.linked then
if packet.type == SCADA_MGMT_TYPES.ESTABLISH then
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- link request confirmation
if packet.length == 1 then
log.debug("received unsolicited establish response")
@ -933,7 +933,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
else
log.debug("SCADA_MGMT establish packet length mismatch")
end
elseif packet.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
elseif packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 and type(packet.data[1]) == "number" then
local timestamp = packet.data[1]
@ -949,7 +949,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
else
log.debug("SCADA_MGMT keep alive packet length/type mismatch")
end
elseif packet.type == SCADA_MGMT_TYPES.CLOSE then
elseif packet.type == SCADA_MGMT_TYPE.CLOSE then
-- handle session close
conn_watchdog.cancel()
public.unlink()
@ -958,7 +958,7 @@ function plc.comms(id, version, modem, local_port, server_port, range, reactor,
else
log.warning("received unsupported SCADA_MGMT packet type " .. packet.type)
end
elseif packet.type == SCADA_MGMT_TYPES.ESTABLISH then
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- link request confirmation
if packet.length == 1 then
local est_ack = packet.data[1]

View File

@ -7,11 +7,11 @@ local modbus = require("rtu.modbus")
local rtu = {}
local PROTOCOLS = comms.PROTOCOLS
local DEVICE_TYPES = comms.DEVICE_TYPES
local PROTOCOL = comms.PROTOCOL
local DEVICE_TYPE = comms.DEVICE_TYPE
local ESTABLISH_ACK = comms.ESTABLISH_ACK
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local print = util.print
local println = util.println
@ -197,14 +197,14 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
_conf_channels()
-- send a scada management packet
---@param msg_type SCADA_MGMT_TYPES
---@param msg_type SCADA_MGMT_TYPE
---@param msg table
local function _send(msg_type, msg)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
self.modem.transmit(self.s_port, self.l_port, s_pkt.raw_sendable())
self.seq_num = self.seq_num + 1
@ -213,7 +213,7 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
-- keep alive ack
---@param srv_time integer
local function _send_keep_alive_ack(srv_time)
_send(SCADA_MGMT_TYPES.KEEP_ALIVE, { srv_time, util.time() })
_send(SCADA_MGMT_TYPE.KEEP_ALIVE, { srv_time, util.time() })
end
-- generate device advertisement table
@ -233,7 +233,7 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
unit.reactor
}
if type == RTU_UNIT_TYPES.REDSTONE then
if type == RTU_UNIT_TYPE.REDSTONE then
insert(advert, unit.device)
end
@ -250,7 +250,7 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
---@param m_pkt modbus_packet
function public.send_modbus(m_pkt)
local s_pkt = comms.scada_packet()
s_pkt.make(self.seq_num, PROTOCOLS.MODBUS_TCP, m_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.MODBUS_TCP, m_pkt.raw_sendable())
self.modem.transmit(self.s_port, self.l_port, s_pkt.raw_sendable())
self.seq_num = self.seq_num + 1
end
@ -275,25 +275,25 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
function public.close(rtu_state)
self.conn_watchdog.cancel()
public.unlink(rtu_state)
_send(SCADA_MGMT_TYPES.CLOSE, {})
_send(SCADA_MGMT_TYPE.CLOSE, {})
end
-- send establish request (includes advertisement)
---@param units table
function public.send_establish(units)
_send(SCADA_MGMT_TYPES.ESTABLISH, { comms.version, self.version, DEVICE_TYPES.RTU, _generate_advertisement(units) })
_send(SCADA_MGMT_TYPE.ESTABLISH, { comms.version, self.version, DEVICE_TYPE.RTU, _generate_advertisement(units) })
end
-- send capability advertisement
---@param units table
function public.send_advertisement(units)
_send(SCADA_MGMT_TYPES.RTU_ADVERT, _generate_advertisement(units))
_send(SCADA_MGMT_TYPE.RTU_ADVERT, _generate_advertisement(units))
end
-- notify that a peripheral was remounted
---@param unit_index integer RTU unit ID
function public.send_remounted(unit_index)
_send(SCADA_MGMT_TYPES.RTU_DEV_REMOUNT, { unit_index })
_send(SCADA_MGMT_TYPE.RTU_DEV_REMOUNT, { unit_index })
end
-- parse a MODBUS/SCADA packet
@ -312,13 +312,13 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
if s_pkt.is_valid() then
-- get as MODBUS TCP packet
if s_pkt.protocol() == PROTOCOLS.MODBUS_TCP then
if s_pkt.protocol() == PROTOCOL.MODBUS_TCP then
local m_pkt = comms.modbus_packet()
if m_pkt.decode(s_pkt) then
pkt = m_pkt.get()
end
-- get as SCADA management packet
elseif s_pkt.protocol() == PROTOCOLS.SCADA_MGMT then
elseif s_pkt.protocol() == PROTOCOL.SCADA_MGMT then
local mgmt_pkt = comms.mgmt_packet()
if mgmt_pkt.decode(s_pkt) then
pkt = mgmt_pkt.get()
@ -352,7 +352,7 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
local protocol = packet.scada_frame.protocol()
if protocol == PROTOCOLS.MODBUS_TCP then
if protocol == PROTOCOL.MODBUS_TCP then
if rtu_state.linked then
local return_code = false
---@diagnostic disable-next-line: param-type-mismatch
@ -401,9 +401,9 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
else
log.debug("discarding MODBUS packet before linked")
end
elseif protocol == PROTOCOLS.SCADA_MGMT then
elseif protocol == PROTOCOL.SCADA_MGMT then
-- SCADA management packet
if packet.type == SCADA_MGMT_TYPES.ESTABLISH then
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
if packet.length == 1 then
local est_ack = packet.data[1]
@ -434,7 +434,7 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
log.debug("SCADA_MGMT establish packet length mismatch")
end
elseif rtu_state.linked then
if packet.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive request received, echo back
if packet.length == 1 and type(packet.data[1]) == "number" then
local timestamp = packet.data[1]
@ -450,13 +450,13 @@ function rtu.comms(version, modem, local_port, server_port, range, conn_watchdog
else
log.debug("SCADA_MGMT keep alive packet length/type mismatch")
end
elseif packet.type == SCADA_MGMT_TYPES.CLOSE then
elseif packet.type == SCADA_MGMT_TYPE.CLOSE then
-- close connection
self.conn_watchdog.cancel()
public.unlink(rtu_state)
println_ts("server connection closed by remote host")
log.warning("server connection closed by remote host")
elseif packet.type == SCADA_MGMT_TYPES.RTU_ADVERT then
elseif packet.type == SCADA_MGMT_TYPE.RTU_ADVERT then
-- request for capabilities again
public.send_advertisement(units)
else

View File

@ -16,8 +16,8 @@ local max_distance = nil
comms.version = "1.4.0"
---@enum PROTOCOLS
local PROTOCOLS = {
---@enum PROTOCOL
local PROTOCOL = {
MODBUS_TCP = 0, -- our "MODBUS TCP"-esque protocol
RPLC = 1, -- reactor PLC protocol
SCADA_MGMT = 2, -- SCADA supervisor management, device advertisements, etc
@ -25,8 +25,8 @@ local PROTOCOLS = {
COORD_API = 4 -- data/control packets for pocket computers to/from coordinators
}
---@enum RPLC_TYPES
local RPLC_TYPES = {
---@enum RPLC_TYPE
local RPLC_TYPE = {
STATUS = 0, -- reactor/system status
MEK_STRUCT = 1, -- mekanism build structure
MEK_BURN_RATE = 2, -- set burn rate
@ -40,8 +40,8 @@ local RPLC_TYPES = {
AUTO_BURN_RATE = 10 -- set an automatic burn rate, PLC will respond with status, enable toggle speed limited
}
---@enum SCADA_MGMT_TYPES
local SCADA_MGMT_TYPES = {
---@enum SCADA_MGMT_TYPE
local SCADA_MGMT_TYPE = {
ESTABLISH = 0, -- establish new connection
KEEP_ALIVE = 1, -- keep alive packet w/ RTT
CLOSE = 2, -- close a connection
@ -49,8 +49,8 @@ local SCADA_MGMT_TYPES = {
RTU_DEV_REMOUNT = 4 -- RTU multiblock possbily changed (formed, unformed) due to PPM remount
}
---@enum SCADA_CRDN_TYPES
local SCADA_CRDN_TYPES = {
---@enum SCADA_CRDN_TYPE
local SCADA_CRDN_TYPE = {
INITIAL_BUILDS = 0, -- initial, complete builds packet to the coordinator
FAC_BUILDS = 1, -- facility RTU builds
FAC_STATUS = 2, -- state of facility and facility devices
@ -60,8 +60,8 @@ local SCADA_CRDN_TYPES = {
UNIT_CMD = 6 -- command a reactor unit
}
---@enum CAPI_TYPES
local CAPI_TYPES = {
---@enum CAPI_TYPE
local CAPI_TYPE = {
}
---@enum ESTABLISH_ACK
@ -72,16 +72,16 @@ local ESTABLISH_ACK = {
BAD_VERSION = 3 -- link denied due to comms version mismatch
}
---@enum DEVICE_TYPES
local DEVICE_TYPES = {
---@enum DEVICE_TYPE
local DEVICE_TYPE = {
PLC = 0, -- PLC device type for establish
RTU = 1, -- RTU device type for establish
SV = 2, -- supervisor device type for establish
CRDN = 3 -- coordinator device type for establish
}
---@enum RTU_UNIT_TYPES
local RTU_UNIT_TYPES = {
---@enum RTU_UNIT_TYPE
local RTU_UNIT_TYPE = {
REDSTONE = 0, -- redstone I/O
BOILER_VALVE = 1, -- boiler mekanism 10.1+
TURBINE_VALVE = 2, -- turbine, mekanism 10.1+
@ -99,16 +99,16 @@ local PLC_AUTO_ACK = {
ZERO_DIS_OK = 3 -- successfully disabled reactor with < 0.01 burn rate
}
---@enum FAC_COMMANDS
local FAC_COMMANDS = {
---@enum FAC_COMMAND
local FAC_COMMAND = {
SCRAM_ALL = 0, -- SCRAM all reactors
STOP = 1, -- stop automatic control
START = 2, -- start automatic control
ACK_ALL_ALARMS = 3 -- acknowledge all alarms on all units
}
---@enum UNIT_COMMANDS
local UNIT_COMMANDS = {
---@enum UNIT_COMMAND
local UNIT_COMMAND = {
SCRAM = 0, -- SCRAM the reactor
START = 1, -- start the reactor
RESET_RPS = 2, -- reset the RPS
@ -120,26 +120,26 @@ local UNIT_COMMANDS = {
SET_GROUP = 8 -- assign this unit to a group
}
comms.PROTOCOLS = PROTOCOLS
comms.PROTOCOL = PROTOCOL
comms.RPLC_TYPES = RPLC_TYPES
comms.SCADA_MGMT_TYPES = SCADA_MGMT_TYPES
comms.SCADA_CRDN_TYPES = SCADA_CRDN_TYPES
comms.CAPI_TYPES = CAPI_TYPES
comms.RPLC_TYPE = RPLC_TYPE
comms.SCADA_MGMT_TYPE = SCADA_MGMT_TYPE
comms.SCADA_CRDN_TYPE = SCADA_CRDN_TYPE
comms.CAPI_TYPE = CAPI_TYPE
comms.ESTABLISH_ACK = ESTABLISH_ACK
comms.DEVICE_TYPES = DEVICE_TYPES
comms.RTU_UNIT_TYPES = RTU_UNIT_TYPES
comms.DEVICE_TYPE = DEVICE_TYPE
comms.RTU_UNIT_TYPE = RTU_UNIT_TYPE
comms.PLC_AUTO_ACK = PLC_AUTO_ACK
comms.UNIT_COMMANDS = UNIT_COMMANDS
comms.FAC_COMMANDS = FAC_COMMANDS
comms.UNIT_COMMAND = UNIT_COMMAND
comms.FAC_COMMAND = FAC_COMMAND
---@alias packet scada_packet|modbus_packet|rplc_packet|mgmt_packet|crdn_packet|capi_packet
---@alias frame modbus_frame|rplc_frame|mgmt_frame|crdn_frame|capi_frame
-- configure the maximum allowable message receive distance <br/>
-- configure the maximum allowable message receive distance<br>
-- packets received with distances greater than this will be silently discarded
---@param distance integer max modem message distance (less than 1 disables the limit)
function comms.set_trusted_range(distance)
@ -168,7 +168,7 @@ function comms.scada_packet()
-- make a SCADA packet
---@param seq_num integer
---@param protocol PROTOCOLS
---@param protocol PROTOCOL
---@param payload table
function public.make(seq_num, protocol, payload)
self.valid = true
@ -296,7 +296,7 @@ function comms.modbus_packet()
if frame then
self.frame = frame
if frame.protocol() == PROTOCOLS.MODBUS_TCP then
if frame.protocol() == PROTOCOL.MODBUS_TCP then
local size_ok = frame.length() >= 3
if size_ok then
@ -359,22 +359,22 @@ function comms.rplc_packet()
-- check that type is known
local function _rplc_type_valid()
return self.type == RPLC_TYPES.STATUS or
self.type == RPLC_TYPES.MEK_STRUCT or
self.type == RPLC_TYPES.MEK_BURN_RATE or
self.type == RPLC_TYPES.RPS_ENABLE or
self.type == RPLC_TYPES.RPS_SCRAM or
self.type == RPLC_TYPES.RPS_ASCRAM or
self.type == RPLC_TYPES.RPS_STATUS or
self.type == RPLC_TYPES.RPS_ALARM or
self.type == RPLC_TYPES.RPS_RESET or
self.type == RPLC_TYPES.RPS_AUTO_RESET or
self.type == RPLC_TYPES.AUTO_BURN_RATE
return self.type == RPLC_TYPE.STATUS or
self.type == RPLC_TYPE.MEK_STRUCT or
self.type == RPLC_TYPE.MEK_BURN_RATE or
self.type == RPLC_TYPE.RPS_ENABLE or
self.type == RPLC_TYPE.RPS_SCRAM or
self.type == RPLC_TYPE.RPS_ASCRAM or
self.type == RPLC_TYPE.RPS_STATUS or
self.type == RPLC_TYPE.RPS_ALARM or
self.type == RPLC_TYPE.RPS_RESET or
self.type == RPLC_TYPE.RPS_AUTO_RESET or
self.type == RPLC_TYPE.AUTO_BURN_RATE
end
-- make an RPLC packet
---@param id integer
---@param packet_type RPLC_TYPES
---@param packet_type RPLC_TYPE
---@param data table
function public.make(id, packet_type, data)
if type(data) == "table" then
@ -401,7 +401,7 @@ function comms.rplc_packet()
if frame then
self.frame = frame
if frame.protocol() == PROTOCOLS.RPLC then
if frame.protocol() == PROTOCOL.RPLC then
local ok = frame.length() >= 2
if ok then
@ -461,16 +461,16 @@ function comms.mgmt_packet()
-- check that type is known
local function _scada_type_valid()
return self.type == SCADA_MGMT_TYPES.ESTABLISH or
self.type == SCADA_MGMT_TYPES.KEEP_ALIVE or
self.type == SCADA_MGMT_TYPES.CLOSE or
self.type == SCADA_MGMT_TYPES.REMOTE_LINKED or
self.type == SCADA_MGMT_TYPES.RTU_ADVERT or
self.type == SCADA_MGMT_TYPES.RTU_DEV_REMOUNT
return self.type == SCADA_MGMT_TYPE.ESTABLISH or
self.type == SCADA_MGMT_TYPE.KEEP_ALIVE or
self.type == SCADA_MGMT_TYPE.CLOSE or
self.type == SCADA_MGMT_TYPE.REMOTE_LINKED or
self.type == SCADA_MGMT_TYPE.RTU_ADVERT or
self.type == SCADA_MGMT_TYPE.RTU_DEV_REMOUNT
end
-- make a SCADA management packet
---@param packet_type SCADA_MGMT_TYPES
---@param packet_type SCADA_MGMT_TYPE
---@param data table
function public.make(packet_type, data)
if type(data) == "table" then
@ -496,7 +496,7 @@ function comms.mgmt_packet()
if frame then
self.frame = frame
if frame.protocol() == PROTOCOLS.SCADA_MGMT then
if frame.protocol() == PROTOCOL.SCADA_MGMT then
local ok = frame.length() >= 1
if ok then
@ -554,17 +554,17 @@ function comms.crdn_packet()
-- check that type is known
---@nodiscard
local function _crdn_type_valid()
return self.type == SCADA_CRDN_TYPES.INITIAL_BUILDS or
self.type == SCADA_CRDN_TYPES.FAC_BUILDS or
self.type == SCADA_CRDN_TYPES.FAC_STATUS or
self.type == SCADA_CRDN_TYPES.FAC_CMD or
self.type == SCADA_CRDN_TYPES.UNIT_BUILDS or
self.type == SCADA_CRDN_TYPES.UNIT_STATUSES or
self.type == SCADA_CRDN_TYPES.UNIT_CMD
return self.type == SCADA_CRDN_TYPE.INITIAL_BUILDS or
self.type == SCADA_CRDN_TYPE.FAC_BUILDS or
self.type == SCADA_CRDN_TYPE.FAC_STATUS or
self.type == SCADA_CRDN_TYPE.FAC_CMD or
self.type == SCADA_CRDN_TYPE.UNIT_BUILDS or
self.type == SCADA_CRDN_TYPE.UNIT_STATUSES or
self.type == SCADA_CRDN_TYPE.UNIT_CMD
end
-- make a coordinator packet
---@param packet_type SCADA_CRDN_TYPES
---@param packet_type SCADA_CRDN_TYPE
---@param data table
function public.make(packet_type, data)
if type(data) == "table" then
@ -590,7 +590,7 @@ function comms.crdn_packet()
if frame then
self.frame = frame
if frame.protocol() == PROTOCOLS.SCADA_CRDN then
if frame.protocol() == PROTOCOL.SCADA_CRDN then
local ok = frame.length() >= 1
if ok then
@ -652,7 +652,7 @@ function comms.capi_packet()
end
-- make a coordinator API packet
---@param packet_type CAPI_TYPES
---@param packet_type CAPI_TYPE
---@param data table
function public.make(packet_type, data)
if type(data) == "table" then
@ -678,7 +678,7 @@ function comms.capi_packet()
if frame then
self.frame = frame
if frame.protocol() == PROTOCOLS.COORD_API then
if frame.protocol() == PROTOCOL.COORD_API then
local ok = frame.length() >= 1
if ok then
@ -722,22 +722,22 @@ end
-- convert rtu_t to RTU unit type
---@nodiscard
---@param type rtu_t
---@return RTU_UNIT_TYPES|nil
---@return RTU_UNIT_TYPE|nil
function comms.rtu_t_to_unit_type(type)
if type == rtu_t.redstone then
return RTU_UNIT_TYPES.REDSTONE
return RTU_UNIT_TYPE.REDSTONE
elseif type == rtu_t.boiler_valve then
return RTU_UNIT_TYPES.BOILER_VALVE
return RTU_UNIT_TYPE.BOILER_VALVE
elseif type == rtu_t.turbine_valve then
return RTU_UNIT_TYPES.TURBINE_VALVE
return RTU_UNIT_TYPE.TURBINE_VALVE
elseif type == rtu_t.induction_matrix then
return RTU_UNIT_TYPES.IMATRIX
return RTU_UNIT_TYPE.IMATRIX
elseif type == rtu_t.sps then
return RTU_UNIT_TYPES.SPS
return RTU_UNIT_TYPE.SPS
elseif type == rtu_t.sna then
return RTU_UNIT_TYPES.SNA
return RTU_UNIT_TYPE.SNA
elseif type == rtu_t.env_detector then
return RTU_UNIT_TYPES.ENV_DETECTOR
return RTU_UNIT_TYPE.ENV_DETECTOR
end
return nil
@ -745,22 +745,22 @@ end
-- convert RTU unit type to rtu_t
---@nodiscard
---@param utype RTU_UNIT_TYPES
---@param utype RTU_UNIT_TYPE
---@return rtu_t|nil
function comms.advert_type_to_rtu_t(utype)
if utype == RTU_UNIT_TYPES.REDSTONE then
if utype == RTU_UNIT_TYPE.REDSTONE then
return rtu_t.redstone
elseif utype == RTU_UNIT_TYPES.BOILER_VALVE then
elseif utype == RTU_UNIT_TYPE.BOILER_VALVE then
return rtu_t.boiler_valve
elseif utype == RTU_UNIT_TYPES.TURBINE_VALVE then
elseif utype == RTU_UNIT_TYPE.TURBINE_VALVE then
return rtu_t.turbine_valve
elseif utype == RTU_UNIT_TYPES.IMATRIX then
elseif utype == RTU_UNIT_TYPE.IMATRIX then
return rtu_t.induction_matrix
elseif utype == RTU_UNIT_TYPES.SPS then
elseif utype == RTU_UNIT_TYPE.SPS then
return rtu_t.sps
elseif utype == RTU_UNIT_TYPES.SNA then
elseif utype == RTU_UNIT_TYPE.SNA then
return rtu_t.sna
elseif utype == RTU_UNIT_TYPES.ENV_DETECTOR then
elseif utype == RTU_UNIT_TYPE.ENV_DETECTOR then
return rtu_t.env_detector
end

View File

@ -58,7 +58,7 @@ function types.new_coordinate(x, y, z) return { x = x, y = y, z = z } end
function types.new_zero_coordinate() return { x = 0, y = 0, z = 0 } end
---@class rtu_advertisement
---@field type RTU_UNIT_TYPES
---@field type RTU_UNIT_TYPE
---@field index integer
---@field reactor integer
---@field rsio table|nil

View File

@ -12,7 +12,7 @@ local PROCESS_NAMES = types.PROCESS_NAMES
local IO = rsio.IO
-- 7.14 kJ per blade for 1 mB of fissile fuel<br/>
-- 7.14 kJ per blade for 1 mB of fissile fuel<br>
-- 2856 FE per blade per 1 mB, 285.6 FE per blade per 0.1 mB (minimum)
local POWER_PER_BLADE = util.joules_to_fe(7140)

View File

@ -7,12 +7,12 @@ local svqtypes = require("supervisor.session.svqtypes")
local coordinator = {}
local PROTOCOLS = comms.PROTOCOLS
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
local SCADA_CRDN_TYPES = comms.SCADA_CRDN_TYPES
local UNIT_COMMANDS = comms.UNIT_COMMANDS
local FAC_COMMANDS = comms.FAC_COMMANDS
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local PROTOCOL = comms.PROTOCOL
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local SCADA_CRDN_TYPE = comms.SCADA_CRDN_TYPE
local UNIT_COMMAND = comms.UNIT_COMMAND
local FAC_COMMAND = comms.FAC_COMMAND
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local SV_Q_CMDS = svqtypes.SV_Q_CMDS
local SV_Q_DATA = svqtypes.SV_Q_DATA
@ -90,28 +90,28 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
end
-- send a CRDN packet
---@param msg_type SCADA_CRDN_TYPES
---@param msg_type SCADA_CRDN_TYPE
---@param msg table
local function _send(msg_type, msg)
local s_pkt = comms.scada_packet()
local c_pkt = comms.crdn_packet()
c_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_CRDN, c_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.SCADA_CRDN, c_pkt.raw_sendable())
self.out_q.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
end
-- send a SCADA management packet
---@param msg_type SCADA_MGMT_TYPES
---@param msg_type SCADA_MGMT_TYPE
---@param msg table
local function _send_mgmt(msg_type, msg)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
self.out_q.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -126,12 +126,12 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
unit_builds[unit.get_id()] = unit.get_build()
end
_send(SCADA_CRDN_TYPES.INITIAL_BUILDS, { facility.get_build(), unit_builds })
_send(SCADA_CRDN_TYPE.INITIAL_BUILDS, { facility.get_build(), unit_builds })
end
-- send facility builds
local function _send_fac_builds()
_send(SCADA_CRDN_TYPES.FAC_BUILDS, { facility.get_build() })
_send(SCADA_CRDN_TYPE.FAC_BUILDS, { facility.get_build() })
end
-- send unit builds
@ -143,7 +143,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
builds[unit.get_id()] = unit.get_build()
end
_send(SCADA_CRDN_TYPES.UNIT_BUILDS, { builds })
_send(SCADA_CRDN_TYPE.UNIT_BUILDS, { builds })
end
-- send facility status
@ -153,7 +153,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
facility.get_rtu_statuses()
}
_send(SCADA_CRDN_TYPES.FAC_STATUS, status)
_send(SCADA_CRDN_TYPE.FAC_STATUS, status)
end
-- send unit statuses
@ -172,7 +172,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
}
end
_send(SCADA_CRDN_TYPES.UNIT_STATUSES, status)
_send(SCADA_CRDN_TYPE.UNIT_STATUSES, status)
end
-- handle a packet
@ -192,8 +192,8 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
self.conn_watchdog.feed()
-- process packet
if pkt.scada_frame.protocol() == PROTOCOLS.SCADA_MGMT then
if pkt.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
if pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
if pkt.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive reply
if pkt.length == 2 then
local srv_start = pkt.data[1]
@ -210,30 +210,30 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end
elseif pkt.type == SCADA_MGMT_TYPES.CLOSE then
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
-- close the session
_close()
else
log.debug(log_header .. "handler received unsupported SCADA_MGMT packet type " .. pkt.type)
end
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_CRDN then
if pkt.type == SCADA_CRDN_TYPES.INITIAL_BUILDS then
elseif pkt.scada_frame.protocol() == PROTOCOL.SCADA_CRDN then
if pkt.type == SCADA_CRDN_TYPE.INITIAL_BUILDS then
-- acknowledgement to coordinator receiving builds
self.acks.builds = true
elseif pkt.type == SCADA_CRDN_TYPES.FAC_BUILDS then
elseif pkt.type == SCADA_CRDN_TYPE.FAC_BUILDS then
-- acknowledgement to coordinator receiving builds
self.acks.fac_builds = true
elseif pkt.type == SCADA_CRDN_TYPES.FAC_CMD then
elseif pkt.type == SCADA_CRDN_TYPE.FAC_CMD then
if pkt.length >= 1 then
local cmd = pkt.data[1]
if cmd == FAC_COMMANDS.SCRAM_ALL then
if cmd == FAC_COMMAND.SCRAM_ALL then
facility.scram_all()
_send(SCADA_CRDN_TYPES.FAC_CMD, { cmd, true })
elseif cmd == FAC_COMMANDS.STOP then
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, true })
elseif cmd == FAC_COMMAND.STOP then
facility.auto_stop()
_send(SCADA_CRDN_TYPES.FAC_CMD, { cmd, true })
elseif cmd == FAC_COMMANDS.START then
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, true })
elseif cmd == FAC_COMMAND.START then
if pkt.length == 6 then
---@type coord_auto_config
local config = {
@ -244,23 +244,23 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
limits = pkt.data[6]
}
_send(SCADA_CRDN_TYPES.FAC_CMD, { cmd, table.unpack(facility.auto_start(config)) })
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, table.unpack(facility.auto_start(config)) })
else
log.debug(log_header .. "CRDN auto start (with configuration) packet length mismatch")
end
elseif cmd == FAC_COMMANDS.ACK_ALL_ALARMS then
elseif cmd == FAC_COMMAND.ACK_ALL_ALARMS then
facility.ack_all()
_send(SCADA_CRDN_TYPES.FAC_CMD, { cmd, true })
_send(SCADA_CRDN_TYPE.FAC_CMD, { cmd, true })
else
log.debug(log_header .. "CRDN facility command unknown")
end
else
log.debug(log_header .. "CRDN facility command packet length mismatch")
end
elseif pkt.type == SCADA_CRDN_TYPES.UNIT_BUILDS then
elseif pkt.type == SCADA_CRDN_TYPE.UNIT_BUILDS then
-- acknowledgement to coordinator receiving builds
self.acks.unit_builds = true
elseif pkt.type == SCADA_CRDN_TYPES.UNIT_CMD then
elseif pkt.type == SCADA_CRDN_TYPE.UNIT_CMD then
if pkt.length >= 2 then
-- get command and unit id
local cmd = pkt.data[1]
@ -273,43 +273,43 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
if util.is_int(uid) and uid > 0 and uid <= #self.units then
local unit = self.units[uid] ---@type reactor_unit
if cmd == UNIT_COMMANDS.START then
if cmd == UNIT_COMMAND.START then
self.out_q.push_data(SV_Q_DATA.START, data)
elseif cmd == UNIT_COMMANDS.SCRAM then
elseif cmd == UNIT_COMMAND.SCRAM then
self.out_q.push_data(SV_Q_DATA.SCRAM, data)
elseif cmd == UNIT_COMMANDS.RESET_RPS then
elseif cmd == UNIT_COMMAND.RESET_RPS then
self.out_q.push_data(SV_Q_DATA.RESET_RPS, data)
elseif cmd == UNIT_COMMANDS.SET_BURN then
elseif cmd == UNIT_COMMAND.SET_BURN then
if pkt.length == 3 then
self.out_q.push_data(SV_Q_DATA.SET_BURN, data)
else
log.debug(log_header .. "CRDN unit command burn rate missing option")
end
elseif cmd == UNIT_COMMANDS.SET_WASTE then
elseif cmd == UNIT_COMMAND.SET_WASTE then
if (pkt.length == 3) and (type(pkt.data[3]) == "number") and (pkt.data[3] > 0) and (pkt.data[3] <= 4) then
unit.set_waste(pkt.data[3])
else
log.debug(log_header .. "CRDN unit command set waste missing option")
end
elseif cmd == UNIT_COMMANDS.ACK_ALL_ALARMS then
elseif cmd == UNIT_COMMAND.ACK_ALL_ALARMS then
unit.ack_all()
_send(SCADA_CRDN_TYPES.UNIT_CMD, { cmd, uid, true })
elseif cmd == UNIT_COMMANDS.ACK_ALARM then
_send(SCADA_CRDN_TYPE.UNIT_CMD, { cmd, uid, true })
elseif cmd == UNIT_COMMAND.ACK_ALARM then
if pkt.length == 3 then
unit.ack_alarm(pkt.data[3])
else
log.debug(log_header .. "CRDN unit command ack alarm missing alarm id")
end
elseif cmd == UNIT_COMMANDS.RESET_ALARM then
elseif cmd == UNIT_COMMAND.RESET_ALARM then
if pkt.length == 3 then
unit.reset_alarm(pkt.data[3])
else
log.debug(log_header .. "CRDN unit command reset alarm missing alarm id")
end
elseif cmd == UNIT_COMMANDS.SET_GROUP then
elseif cmd == UNIT_COMMAND.SET_GROUP then
if (pkt.length == 3) and (type(pkt.data[3]) == "number") and (pkt.data[3] >= 0) and (pkt.data[3] <= 4) then
facility.set_group(unit.get_id(), pkt.data[3])
_send(SCADA_CRDN_TYPES.UNIT_CMD, { cmd, uid, pkt.data[3] })
_send(SCADA_CRDN_TYPE.UNIT_CMD, { cmd, uid, pkt.data[3] })
else
log.debug(log_header .. "CRDN unit command set group missing group id")
end
@ -342,7 +342,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
-- close the connection
function public.close()
_close()
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
println("connection to coordinator " .. id .. " closed by server")
log.info(log_header .. "session closed by server")
end
@ -373,7 +373,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
if cmd.key == CRD_S_DATA.CMD_ACK then
local ack = cmd.val ---@type coord_ack
_send(SCADA_CRDN_TYPES.UNIT_CMD, { ack.cmd, ack.unit, ack.ack })
_send(SCADA_CRDN_TYPE.UNIT_CMD, { ack.cmd, ack.unit, ack.ack })
elseif cmd.key == CRD_S_DATA.RESEND_PLC_BUILD then
-- re-send PLC build
-- retry logic will be kept as-is, so as long as no retry is needed, this will be a small update
@ -386,7 +386,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
local unit = self.units[unit_id] ---@type reactor_unit
builds[unit_id] = unit.get_build(true, false, false)
_send(SCADA_CRDN_TYPES.UNIT_BUILDS, { builds })
_send(SCADA_CRDN_TYPE.UNIT_BUILDS, { builds })
elseif cmd.key == CRD_S_DATA.RESEND_RTU_BUILD then
local unit_id = cmd.val.unit
if unit_id > 0 then
@ -398,16 +398,16 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
local builds = {}
local unit = self.units[unit_id] ---@type reactor_unit
builds[unit_id] = unit.get_build(false, cmd.val.type == RTU_UNIT_TYPES.BOILER_VALVE, cmd.val.type == RTU_UNIT_TYPES.TURBINE_VALVE)
builds[unit_id] = unit.get_build(false, cmd.val.type == RTU_UNIT_TYPE.BOILER_VALVE, cmd.val.type == RTU_UNIT_TYPE.TURBINE_VALVE)
_send(SCADA_CRDN_TYPES.UNIT_BUILDS, { builds })
_send(SCADA_CRDN_TYPE.UNIT_BUILDS, { builds })
else
-- re-send facility RTU builds
-- retry logic will be kept as-is, so as long as no retry is needed, this will be a small update
self.retry_times.f_builds_packet = util.time() + PARTIAL_RETRY_PERIOD
self.acks.fac_builds = false
_send(SCADA_CRDN_TYPES.FAC_BUILDS, { facility.get_build(cmd.val.type == RTU_UNIT_TYPES.IMATRIX) })
_send(SCADA_CRDN_TYPE.FAC_BUILDS, { facility.get_build(cmd.val.type == RTU_UNIT_TYPE.IMATRIX) })
end
else
log.warning(log_header .. "unsupported data command received in in_queue (this is a bug)")
@ -441,7 +441,7 @@ function coordinator.new_session(id, in_queue, out_queue, timeout, facility)
periodics.keep_alive = periodics.keep_alive + elapsed
if periodics.keep_alive >= PERIODICS.KEEP_ALIVE then
_send_mgmt(SCADA_MGMT_TYPES.KEEP_ALIVE, { util.time() })
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { util.time() })
periodics.keep_alive = 0
end

View File

@ -8,12 +8,12 @@ local svqtypes = require("supervisor.session.svqtypes")
local plc = {}
local PROTOCOLS = comms.PROTOCOLS
local RPLC_TYPES = comms.RPLC_TYPES
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
local PROTOCOL = comms.PROTOCOL
local RPLC_TYPE = comms.RPLC_TYPE
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local PLC_AUTO_ACK = comms.PLC_AUTO_ACK
local UNIT_COMMANDS = comms.UNIT_COMMANDS
local UNIT_COMMAND = comms.UNIT_COMMAND
local print = util.print
local println = util.println
@ -244,28 +244,28 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
end
-- send an RPLC packet
---@param msg_type RPLC_TYPES
---@param msg_type RPLC_TYPE
---@param msg table
local function _send(msg_type, msg)
local s_pkt = comms.scada_packet()
local r_pkt = comms.rplc_packet()
r_pkt.make(for_reactor, msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOLS.RPLC, r_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.RPLC, r_pkt.raw_sendable())
self.out_q.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
end
-- send a SCADA management packet
---@param msg_type SCADA_MGMT_TYPES
---@param msg_type SCADA_MGMT_TYPE
---@param msg table
local function _send_mgmt(msg_type, msg)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
self.out_q.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -297,7 +297,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
end
-- process packet
if pkt.scada_frame.protocol() == PROTOCOLS.RPLC then
if pkt.scada_frame.protocol() == PROTOCOL.RPLC then
-- check reactor ID
if pkt.id ~= for_reactor then
log.warning(log_header .. "RPLC packet with ID not matching reactor ID: reactor " .. self.for_reactor .. " != " .. pkt.id)
@ -308,7 +308,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
self.plc_conn_watchdog.feed()
-- handle packet by type
if pkt.type == RPLC_TYPES.STATUS then
if pkt.type == RPLC_TYPE.STATUS then
-- status packet received, update data
if pkt.length >= 5 then
self.sDB.last_status_update = pkt.data[1]
@ -335,7 +335,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
else
log.debug(log_header .. "RPLC status packet length mismatch")
end
elseif pkt.type == RPLC_TYPES.MEK_STRUCT then
elseif pkt.type == RPLC_TYPE.MEK_STRUCT then
-- received reactor structure, record it
if pkt.length == 14 then
local status = pcall(_copy_struct, pkt.data)
@ -350,7 +350,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
else
log.debug(log_header .. "RPLC struct packet length mismatch")
end
elseif pkt.type == RPLC_TYPES.MEK_BURN_RATE then
elseif pkt.type == RPLC_TYPE.MEK_BURN_RATE then
-- burn rate acknowledgement
local ack = _get_ack(pkt)
if ack then
@ -362,10 +362,10 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
-- send acknowledgement to coordinator
self.out_q.push_data(svqtypes.SV_Q_DATA.CRDN_ACK, {
unit = self.for_reactor,
cmd = UNIT_COMMANDS.SET_BURN,
cmd = UNIT_COMMAND.SET_BURN,
ack = ack
})
elseif pkt.type == RPLC_TYPES.RPS_ENABLE then
elseif pkt.type == RPLC_TYPE.RPS_ENABLE then
-- enable acknowledgement
local ack = _get_ack(pkt)
if ack then
@ -377,10 +377,10 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
-- send acknowledgement to coordinator
self.out_q.push_data(svqtypes.SV_Q_DATA.CRDN_ACK, {
unit = self.for_reactor,
cmd = UNIT_COMMANDS.START,
cmd = UNIT_COMMAND.START,
ack = ack
})
elseif pkt.type == RPLC_TYPES.RPS_SCRAM then
elseif pkt.type == RPLC_TYPE.RPS_SCRAM then
-- manual SCRAM acknowledgement
local ack = _get_ack(pkt)
if ack then
@ -393,10 +393,10 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
-- send acknowledgement to coordinator
self.out_q.push_data(svqtypes.SV_Q_DATA.CRDN_ACK, {
unit = self.for_reactor,
cmd = UNIT_COMMANDS.SCRAM,
cmd = UNIT_COMMAND.SCRAM,
ack = ack
})
elseif pkt.type == RPLC_TYPES.RPS_ASCRAM then
elseif pkt.type == RPLC_TYPE.RPS_ASCRAM then
-- automatic SCRAM acknowledgement
local ack = _get_ack(pkt)
if ack then
@ -405,7 +405,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
elseif ack == false then
log.debug(log_header .. " automatic SCRAM failed!")
end
elseif pkt.type == RPLC_TYPES.RPS_STATUS then
elseif pkt.type == RPLC_TYPE.RPS_STATUS then
-- RPS status packet received, copy data
if pkt.length == 14 then
local status = pcall(_copy_rps_status, pkt.data)
@ -418,7 +418,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
else
log.debug(log_header .. "RPLC RPS status packet length mismatch")
end
elseif pkt.type == RPLC_TYPES.RPS_ALARM then
elseif pkt.type == RPLC_TYPE.RPS_ALARM then
-- RPS alarm
if pkt.length == 13 then
local status = pcall(_copy_rps_status, { true, table.unpack(pkt.data) })
@ -431,7 +431,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
else
log.debug(log_header .. "RPLC RPS alarm packet length mismatch")
end
elseif pkt.type == RPLC_TYPES.RPS_RESET then
elseif pkt.type == RPLC_TYPE.RPS_RESET then
-- RPS reset acknowledgement
local ack = _get_ack(pkt)
if ack then
@ -445,16 +445,16 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
-- send acknowledgement to coordinator
self.out_q.push_data(svqtypes.SV_Q_DATA.CRDN_ACK, {
unit = self.for_reactor,
cmd = UNIT_COMMANDS.RESET_RPS,
cmd = UNIT_COMMAND.RESET_RPS,
ack = ack
})
elseif pkt.type == RPLC_TYPES.RPS_AUTO_RESET then
elseif pkt.type == RPLC_TYPE.RPS_AUTO_RESET then
-- RPS auto control reset acknowledgement
local ack = _get_ack(pkt)
if not ack then
log.debug(log_header .. "RPS auto reset failed")
end
elseif pkt.type == RPLC_TYPES.AUTO_BURN_RATE then
elseif pkt.type == RPLC_TYPE.AUTO_BURN_RATE then
if pkt.length == 1 then
local ack = pkt.data[1]
@ -473,8 +473,8 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
else
log.debug(log_header .. "handler received unsupported RPLC packet type " .. pkt.type)
end
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_MGMT then
if pkt.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
elseif pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
if pkt.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive reply
if pkt.length == 2 then
local srv_start = pkt.data[1]
@ -491,7 +491,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end
elseif pkt.type == SCADA_MGMT_TYPES.CLOSE then
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
-- close the session
_close()
else
@ -575,7 +575,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
-- close the connection
function public.close()
_close()
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
println("connection to reactor " .. self.for_reactor .. " PLC closed by server")
log.info(log_header .. "session closed by server")
end
@ -604,27 +604,27 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
if cmd == PLC_S_CMDS.ENABLE then
-- enable reactor
if not self.auto_lock then
_send(RPLC_TYPES.RPS_ENABLE, {})
_send(RPLC_TYPE.RPS_ENABLE, {})
end
elseif cmd == PLC_S_CMDS.SCRAM then
-- SCRAM reactor
self.acks.scram = false
self.retry_times.scram_req = util.time() + INITIAL_WAIT
_send(RPLC_TYPES.RPS_SCRAM, {})
_send(RPLC_TYPE.RPS_SCRAM, {})
elseif cmd == PLC_S_CMDS.ASCRAM then
-- SCRAM reactor
self.acks.ascram = false
self.retry_times.ascram_req = util.time() + INITIAL_WAIT
_send(RPLC_TYPES.RPS_ASCRAM, {})
_send(RPLC_TYPE.RPS_ASCRAM, {})
elseif cmd == PLC_S_CMDS.RPS_RESET then
-- reset RPS
self.acks.ascram = true
self.acks.rps_reset = false
self.retry_times.rps_reset_req = util.time() + INITIAL_WAIT
_send(RPLC_TYPES.RPS_RESET, {})
_send(RPLC_TYPE.RPS_RESET, {})
elseif cmd == PLC_S_CMDS.RPS_AUTO_RESET then
if self.sDB.rps_status.automatic or self.sDB.rps_status.timeout then
_send(RPLC_TYPES.RPS_AUTO_RESET, {})
_send(RPLC_TYPE.RPS_AUTO_RESET, {})
end
else
log.warning(log_header .. "unsupported command received in in_queue (this is a bug)")
@ -642,7 +642,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
self.ramping_rate = false
self.acks.burn_rate = false
self.retry_times.burn_rate_req = util.time() + INITIAL_WAIT
_send(RPLC_TYPES.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
_send(RPLC_TYPE.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
end
end
elseif cmd.key == PLC_S_DATA.RAMP_BURN_RATE then
@ -655,7 +655,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
self.ramping_rate = true
self.acks.burn_rate = false
self.retry_times.burn_rate_req = util.time() + INITIAL_WAIT
_send(RPLC_TYPES.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
_send(RPLC_TYPE.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
end
end
elseif cmd.key == PLC_S_DATA.AUTO_BURN_RATE then
@ -670,7 +670,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
self.acks.burn_rate = not self.ramping_rate
self.retry_times.burn_rate_req = util.time() + INITIAL_AUTO_WAIT
_send(RPLC_TYPES.AUTO_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate, self.auto_cmd_token })
_send(RPLC_TYPE.AUTO_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate, self.auto_cmd_token })
end
end
else
@ -705,7 +705,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
periodics.keep_alive = periodics.keep_alive + elapsed
if periodics.keep_alive >= PERIODICS.KEEP_ALIVE then
_send_mgmt(SCADA_MGMT_TYPES.KEEP_ALIVE, { util.time() })
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { util.time() })
periodics.keep_alive = 0
end
@ -722,7 +722,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
if not self.received_struct then
if rtimes.struct_req - util.time() <= 0 then
_send(RPLC_TYPES.MEK_STRUCT, {})
_send(RPLC_TYPE.MEK_STRUCT, {})
rtimes.struct_req = util.time() + RETRY_PERIOD
end
end
@ -731,7 +731,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
if not self.received_status_cache then
if rtimes.status_req - util.time() <= 0 then
_send(RPLC_TYPES.MEK_STATUS, {})
_send(RPLC_TYPE.MEK_STATUS, {})
rtimes.status_req = util.time() + RETRY_PERIOD
end
end
@ -742,13 +742,13 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
if rtimes.burn_rate_req - util.time() <= 0 then
if self.auto_cmd_token > 0 then
if self.auto_lock then
_send(RPLC_TYPES.AUTO_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate, self.auto_cmd_token })
_send(RPLC_TYPE.AUTO_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate, self.auto_cmd_token })
else
-- would have been an auto command, but disengaged, so stop retrying
self.acks.burn_rate = true
end
elseif not self.auto_lock then
_send(RPLC_TYPES.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
_send(RPLC_TYPE.MEK_BURN_RATE, { self.commanded_burn_rate, self.ramping_rate })
else
-- shouldn't be in this state, just pretend it was acknowledged
self.acks.burn_rate = true
@ -763,7 +763,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
if not self.acks.scram then
if rtimes.scram_req - util.time() <= 0 then
_send(RPLC_TYPES.RPS_SCRAM, {})
_send(RPLC_TYPE.RPS_SCRAM, {})
rtimes.scram_req = util.time() + RETRY_PERIOD
end
end
@ -772,7 +772,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
if not self.acks.ascram then
if rtimes.ascram_req - util.time() <= 0 then
_send(RPLC_TYPES.RPS_ASCRAM, {})
_send(RPLC_TYPE.RPS_ASCRAM, {})
rtimes.ascram_req = util.time() + RETRY_PERIOD
end
end
@ -781,7 +781,7 @@ function plc.new_session(id, for_reactor, in_queue, out_queue, timeout)
if not self.acks.rps_reset then
if rtimes.rps_reset_req - util.time() <= 0 then
_send(RPLC_TYPES.RPS_RESET, {})
_send(RPLC_TYPE.RPS_RESET, {})
rtimes.rps_reset_req = util.time() + RETRY_PERIOD
end
end

View File

@ -18,9 +18,9 @@ local svrs_turbinev = require("supervisor.session.rtu.turbinev")
local rtu = {}
local PROTOCOLS = comms.PROTOCOLS
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local PROTOCOL = comms.PROTOCOL
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local print = util.print
local println = util.println
@ -99,7 +99,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
advert_validator.assert_type_int(unit_advert.index)
advert_validator.assert_type_int(unit_advert.reactor)
if u_type == RTU_UNIT_TYPES.REDSTONE then
if u_type == RTU_UNIT_TYPE.REDSTONE then
advert_validator.assert_type_table(unit_advert.rsio)
end
@ -124,19 +124,19 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
if unit_advert.reactor > 0 then
local target_unit = self.fac_units[unit_advert.reactor] ---@type reactor_unit
if u_type == RTU_UNIT_TYPES.REDSTONE then
if u_type == RTU_UNIT_TYPE.REDSTONE then
-- redstone
unit = svrs_redstone.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_redstone(unit) end
elseif u_type == RTU_UNIT_TYPES.BOILER_VALVE then
elseif u_type == RTU_UNIT_TYPE.BOILER_VALVE then
-- boiler (Mekanism 10.1+)
unit = svrs_boilerv.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_boiler(unit) end
elseif u_type == RTU_UNIT_TYPES.TURBINE_VALVE then
elseif u_type == RTU_UNIT_TYPE.TURBINE_VALVE then
-- turbine (Mekanism 10.1+)
unit = svrs_turbinev.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_turbine(unit) end
elseif u_type == RTU_UNIT_TYPES.ENV_DETECTOR then
elseif u_type == RTU_UNIT_TYPE.ENV_DETECTOR then
-- environment detector
unit = svrs_envd.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then target_unit.add_envd(unit) end
@ -144,21 +144,21 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
log.error(util.c(log_header, "bad advertisement: encountered unsupported reactor-specific RTU type ", type_string))
end
else
if u_type == RTU_UNIT_TYPES.REDSTONE then
if u_type == RTU_UNIT_TYPE.REDSTONE then
-- redstone
unit = svrs_redstone.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then facility.add_redstone(unit) end
elseif u_type == RTU_UNIT_TYPES.IMATRIX then
elseif u_type == RTU_UNIT_TYPE.IMATRIX then
-- induction matrix
unit = svrs_imatrix.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then facility.add_imatrix(unit) end
elseif u_type == RTU_UNIT_TYPES.SPS then
elseif u_type == RTU_UNIT_TYPE.SPS then
-- super-critical phase shifter
unit = svrs_sps.new(id, i, unit_advert, self.modbus_q)
elseif u_type == RTU_UNIT_TYPES.SNA then
elseif u_type == RTU_UNIT_TYPE.SNA then
-- solar neutron activator
unit = svrs_sna.new(id, i, unit_advert, self.modbus_q)
elseif u_type == RTU_UNIT_TYPES.ENV_DETECTOR then
elseif u_type == RTU_UNIT_TYPE.ENV_DETECTOR then
-- environment detector
unit = svrs_envd.new(id, i, unit_advert, self.modbus_q)
if type(unit) ~= "nil" then facility.add_envd(unit) end
@ -194,21 +194,21 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
local function _send_modbus(m_pkt)
local s_pkt = comms.scada_packet()
s_pkt.make(self.seq_num, PROTOCOLS.MODBUS_TCP, m_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.MODBUS_TCP, m_pkt.raw_sendable())
self.out_q.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
end
-- send a SCADA management packet
---@param msg_type SCADA_MGMT_TYPES
---@param msg_type SCADA_MGMT_TYPE
---@param msg table
local function _send_mgmt(msg_type, msg)
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(msg_type, msg)
s_pkt.make(self.seq_num, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
s_pkt.make(self.seq_num, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
self.out_q.push_packet(s_pkt)
self.seq_num = self.seq_num + 1
@ -231,15 +231,15 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
self.rtu_conn_watchdog.feed()
-- process packet
if pkt.scada_frame.protocol() == PROTOCOLS.MODBUS_TCP then
if pkt.scada_frame.protocol() == PROTOCOL.MODBUS_TCP then
if self.units[pkt.unit_id] ~= nil then
local unit = self.units[pkt.unit_id] ---@type unit_session
---@diagnostic disable-next-line: param-type-mismatch
unit.handle_packet(pkt)
end
elseif pkt.scada_frame.protocol() == PROTOCOLS.SCADA_MGMT then
elseif pkt.scada_frame.protocol() == PROTOCOL.SCADA_MGMT then
-- handle management packet
if pkt.type == SCADA_MGMT_TYPES.KEEP_ALIVE then
if pkt.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
-- keep alive reply
if pkt.length == 2 then
local srv_start = pkt.data[1]
@ -256,10 +256,10 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
else
log.debug(log_header .. "SCADA keep alive packet length mismatch")
end
elseif pkt.type == SCADA_MGMT_TYPES.CLOSE then
elseif pkt.type == SCADA_MGMT_TYPE.CLOSE then
-- close the session
_close()
elseif pkt.type == SCADA_MGMT_TYPES.RTU_ADVERT then
elseif pkt.type == SCADA_MGMT_TYPE.RTU_ADVERT then
-- RTU unit advertisement
log.debug(log_header .. "received updated advertisement")
@ -269,7 +269,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
-- handle advertisement; this will re-create all unit sub-sessions
_handle_advertisement()
elseif pkt.type == SCADA_MGMT_TYPES.RTU_DEV_REMOUNT then
elseif pkt.type == SCADA_MGMT_TYPE.RTU_DEV_REMOUNT then
if pkt.length == 1 then
local unit_id = pkt.data[1]
if self.units[unit_id] ~= nil then
@ -299,7 +299,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
-- close the connection
function public.close()
_close()
_send_mgmt(SCADA_MGMT_TYPES.CLOSE, {})
_send_mgmt(SCADA_MGMT_TYPE.CLOSE, {})
println(log_header .. "connection to RTU closed by server")
log.info(log_header .. "session closed by server")
end
@ -365,7 +365,7 @@ function rtu.new_session(id, in_queue, out_queue, timeout, advertisement, facili
periodics.keep_alive = periodics.keep_alive + elapsed
if periodics.keep_alive >= PERIODICS.KEEP_ALIVE then
_send_mgmt(SCADA_MGMT_TYPES.KEEP_ALIVE, { util.time() })
_send_mgmt(SCADA_MGMT_TYPE.KEEP_ALIVE, { util.time() })
periodics.keep_alive = 0
end

View File

@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
local boilerv = {}
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local MODBUS_FCODE = types.MODBUS_FCODE
local TXN_TYPES = {
@ -38,7 +38,7 @@ local PERIODICS = {
---@param out_queue mqueue RTU unit message out queue
function boilerv.new(session_id, unit_id, advert, out_queue)
-- type check
if advert.type ~= RTU_UNIT_TYPES.BOILER_VALVE then
if advert.type ~= RTU_UNIT_TYPE.BOILER_VALVE then
log.error("attempt to instantiate boilerv RTU for type '" .. advert.type .. "'. this is a bug.")
return nil
end

View File

@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
local envd = {}
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local MODBUS_FCODE = types.MODBUS_FCODE
local TXN_TYPES = {
@ -29,7 +29,7 @@ local PERIODICS = {
---@param out_queue mqueue
function envd.new(session_id, unit_id, advert, out_queue)
-- type check
if advert.type ~= RTU_UNIT_TYPES.ENV_DETECTOR then
if advert.type ~= RTU_UNIT_TYPE.ENV_DETECTOR then
log.error("attempt to instantiate envd RTU for type '" .. advert.type .. "'. this is a bug.")
return nil
end

View File

@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
local imatrix = {}
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local MODBUS_FCODE = types.MODBUS_FCODE
local TXN_TYPES = {
@ -38,7 +38,7 @@ local PERIODICS = {
---@param out_queue mqueue RTU unit message out queue
function imatrix.new(session_id, unit_id, advert, out_queue)
-- type check
if advert.type ~= RTU_UNIT_TYPES.IMATRIX then
if advert.type ~= RTU_UNIT_TYPE.IMATRIX then
log.error("attempt to instantiate imatrix RTU for type '" .. advert.type .. "'. this is a bug.")
return nil
end

View File

@ -9,7 +9,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
local redstone = {}
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local MODBUS_FCODE = types.MODBUS_FCODE
local IO_PORT = rsio.IO
@ -53,7 +53,7 @@ local PERIODICS = {
---@param out_queue mqueue
function redstone.new(session_id, unit_id, advert, out_queue)
-- type check
if advert.type ~= RTU_UNIT_TYPES.REDSTONE then
if advert.type ~= RTU_UNIT_TYPE.REDSTONE then
log.error("attempt to instantiate redstone RTU for type '" .. advert.type .. "'. this is a bug.")
return nil
end

View File

@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
local sna = {}
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local MODBUS_FCODE = types.MODBUS_FCODE
local TXN_TYPES = {
@ -35,7 +35,7 @@ local PERIODICS = {
---@param out_queue mqueue RTU unit message out queue
function sna.new(session_id, unit_id, advert, out_queue)
-- type check
if advert.type ~= RTU_UNIT_TYPES.SNA then
if advert.type ~= RTU_UNIT_TYPE.SNA then
log.error("attempt to instantiate sna RTU for type '" .. advert.type .. "'. this is a bug.")
return nil
end

View File

@ -7,7 +7,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
local sps = {}
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local MODBUS_FCODE = types.MODBUS_FCODE
local TXN_TYPES = {
@ -38,7 +38,7 @@ local PERIODICS = {
---@param out_queue mqueue RTU unit message out queue
function sps.new(session_id, unit_id, advert, out_queue)
-- type check
if advert.type ~= RTU_UNIT_TYPES.SPS then
if advert.type ~= RTU_UNIT_TYPE.SPS then
log.error("attempt to instantiate sps RTU for type '" .. advert.type .. "'. this is a bug.")
return nil
end

View File

@ -9,7 +9,7 @@ local unit_session = require("supervisor.session.rtu.unit_session")
local turbinev = {}
local RTU_UNIT_TYPES = comms.RTU_UNIT_TYPES
local RTU_UNIT_TYPE = comms.RTU_UNIT_TYPE
local DUMPING_MODE = types.DUMPING_MODE
local MODBUS_FCODE = types.MODBUS_FCODE
@ -50,7 +50,7 @@ local PERIODICS = {
---@param out_queue mqueue RTU unit message out queue
function turbinev.new(session_id, unit_id, advert, out_queue)
-- type check
if advert.type ~= RTU_UNIT_TYPES.TURBINE_VALVE then
if advert.type ~= RTU_UNIT_TYPE.TURBINE_VALVE then
log.error("attempt to instantiate turbinev RTU for type '" .. advert.type .. "'. this is a bug.")
return nil
end

View File

@ -8,7 +8,7 @@ local txnctrl = require("supervisor.session.rtu.txnctrl")
local unit_session = {}
local PROTOCOLS = comms.PROTOCOLS
local PROTOCOL = comms.PROTOCOL
local MODBUS_FCODE = types.MODBUS_FCODE
local MODBUS_EXCODE = types.MODBUS_EXCODE
@ -72,7 +72,7 @@ function unit_session.new(session_id, unit_id, advert, out_queue, log_tag, txn_t
---@param m_pkt modbus_frame MODBUS packet
---@return integer|false txn_type, integer txn_id transaction type or false on error/busy, transaction ID
function protected.try_resolve(m_pkt)
if m_pkt.scada_frame.protocol() == PROTOCOLS.MODBUS_TCP then
if m_pkt.scada_frame.protocol() == PROTOCOL.MODBUS_TCP then
if m_pkt.unit_id == self.unit_id then
local txn_type = self.transaction_controller.resolve(m_pkt.txn_id)
local txn_tag = " (" .. util.strval(self.txn_tags[txn_type]) .. ")"

View File

@ -6,10 +6,10 @@ local svsessions = require("supervisor.session.svsessions")
local supervisor = {}
local PROTOCOLS = comms.PROTOCOLS
local DEVICE_TYPES = comms.DEVICE_TYPES
local PROTOCOL = comms.PROTOCOL
local DEVICE_TYPE = comms.DEVICE_TYPE
local ESTABLISH_ACK = comms.ESTABLISH_ACK
local SCADA_MGMT_TYPES = comms.SCADA_MGMT_TYPES
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
local print = util.print
local println = util.println
@ -60,8 +60,8 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
local s_pkt = comms.scada_packet()
local m_pkt = comms.mgmt_packet()
m_pkt.make(SCADA_MGMT_TYPES.ESTABLISH, msg)
s_pkt.make(seq_id, PROTOCOLS.SCADA_MGMT, m_pkt.raw_sendable())
m_pkt.make(SCADA_MGMT_TYPE.ESTABLISH, msg)
s_pkt.make(seq_id, PROTOCOL.SCADA_MGMT, m_pkt.raw_sendable())
self.modem.transmit(dest, self.dev_listen, s_pkt.raw_sendable())
end
@ -74,8 +74,8 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
local s_pkt = comms.scada_packet()
local c_pkt = comms.mgmt_packet()
c_pkt.make(SCADA_MGMT_TYPES.ESTABLISH, msg)
s_pkt.make(seq_id, PROTOCOLS.SCADA_MGMT, c_pkt.raw_sendable())
c_pkt.make(SCADA_MGMT_TYPE.ESTABLISH, msg)
s_pkt.make(seq_id, PROTOCOL.SCADA_MGMT, c_pkt.raw_sendable())
self.modem.transmit(dest, self.coord_listen, s_pkt.raw_sendable())
end
@ -107,25 +107,25 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
if s_pkt.is_valid() then
-- get as MODBUS TCP packet
if s_pkt.protocol() == PROTOCOLS.MODBUS_TCP then
if s_pkt.protocol() == PROTOCOL.MODBUS_TCP then
local m_pkt = comms.modbus_packet()
if m_pkt.decode(s_pkt) then
pkt = m_pkt.get()
end
-- get as RPLC packet
elseif s_pkt.protocol() == PROTOCOLS.RPLC then
elseif s_pkt.protocol() == PROTOCOL.RPLC then
local rplc_pkt = comms.rplc_packet()
if rplc_pkt.decode(s_pkt) then
pkt = rplc_pkt.get()
end
-- get as SCADA management packet
elseif s_pkt.protocol() == PROTOCOLS.SCADA_MGMT then
elseif s_pkt.protocol() == PROTOCOL.SCADA_MGMT then
local mgmt_pkt = comms.mgmt_packet()
if mgmt_pkt.decode(s_pkt) then
pkt = mgmt_pkt.get()
end
-- get as coordinator packet
elseif s_pkt.protocol() == PROTOCOLS.SCADA_CRDN then
elseif s_pkt.protocol() == PROTOCOL.SCADA_CRDN then
local crdn_pkt = comms.crdn_packet()
if crdn_pkt.decode(s_pkt) then
pkt = crdn_pkt.get()
@ -148,7 +148,7 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
-- device (RTU/PLC) listening channel
if l_port == self.dev_listen then
if protocol == PROTOCOLS.MODBUS_TCP then
if protocol == PROTOCOL.MODBUS_TCP then
-- look for an associated session
local session = svsessions.find_rtu_session(r_port)
@ -160,7 +160,7 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
-- any other packet should be session related, discard it
log.debug("discarding MODBUS_TCP packet without a known session")
end
elseif protocol == PROTOCOLS.RPLC then
elseif protocol == PROTOCOL.RPLC then
-- look for an associated session
local session = svsessions.find_plc_session(r_port)
@ -173,7 +173,7 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
log.debug("PLC_ESTABLISH: no session but not an establish, forcing relink")
_send_dev_establish(packet.scada_frame.seq_num() + 1, r_port, { ESTABLISH_ACK.DENY })
end
elseif protocol == PROTOCOLS.SCADA_MGMT then
elseif protocol == PROTOCOL.SCADA_MGMT then
-- look for an associated session
local session = svsessions.find_device_session(r_port)
@ -181,7 +181,7 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == SCADA_MGMT_TYPES.ESTABLISH then
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- establish a new session
local next_seq_id = packet.scada_frame.seq_num() + 1
@ -198,7 +198,7 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
return
end
if dev_type == DEVICE_TYPES.PLC then
if dev_type == DEVICE_TYPE.PLC then
-- PLC linking request
if packet.length == 4 and type(packet.data[4]) == "number" then
local reactor_id = packet.data[4]
@ -218,7 +218,7 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
log.debug("PLC_ESTABLISH: packet length mismatch/bad parameter type")
_send_dev_establish(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
end
elseif dev_type == DEVICE_TYPES.RTU then
elseif dev_type == DEVICE_TYPE.RTU then
if packet.length == 4 then
-- this is an RTU advertisement for a new session
local rtu_advert = packet.data[4]
@ -251,12 +251,12 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
-- look for an associated session
local session = svsessions.find_coord_session(r_port)
if protocol == PROTOCOLS.SCADA_MGMT then
if protocol == PROTOCOL.SCADA_MGMT then
-- SCADA management packet
if session ~= nil then
-- pass the packet onto the session handler
session.in_queue.push_packet(packet)
elseif packet.type == SCADA_MGMT_TYPES.ESTABLISH then
elseif packet.type == SCADA_MGMT_TYPE.ESTABLISH then
-- establish a new session
local next_seq_id = packet.scada_frame.seq_num() + 1
@ -271,7 +271,7 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
" (expected v", comms.version, ")"))
_send_crdn_establish(next_seq_id, r_port, { ESTABLISH_ACK.BAD_VERSION })
return
elseif dev_type ~= DEVICE_TYPES.CRDN then
elseif dev_type ~= DEVICE_TYPE.CRDN then
log.debug(util.c("illegal establish packet for device ", dev_type, " on CRDN listening channel"))
_send_crdn_establish(next_seq_id, r_port, { ESTABLISH_ACK.DENY })
return
@ -302,7 +302,7 @@ function supervisor.comms(version, num_reactors, cooling_conf, modem, dev_listen
-- any other packet should be session related, discard it
log.debug(r_port .. "->" .. l_port .. ": discarding SCADA_MGMT packet without a known session")
end
elseif protocol == PROTOCOLS.SCADA_CRDN then
elseif protocol == PROTOCOL.SCADA_CRDN then
-- coordinator packet
if session ~= nil then
-- pass the packet onto the session handler