Adjust retraction tower parameters

20% infill for base, hollow after that.
z seam to centre of model.
This commit is contained in:
lawgicau
2021-07-15 17:57:50 +10:00
parent e6409f7995
commit 7889839e3d

View File

@ -102,12 +102,14 @@
<p>Baseline test: No changes</p>
<p>Retraction test:</p>
<ul>
<li>Z seam alignment set to 50, 50 mm</li>
<li>'Process-1' from 0mm</li>
<li>'Process-2' from 5mm - 5.5 mm retraction at 41 mm/sec</li>
<li>'Process-3' from 10mm - 6.0 mm retraction at 42 mm/sec</li>
<li>'Process-4' from 15mm - 6.5 mm retraction at 43 mm/sec</li>
<li>'Process-5' from 20mm - 7.0 mm retraction at 44 mm/sec</li>
<li>'Process-6' from 25mm - 7.5 mm retraction at 45 mm/sec</li>
<li>'Process-2' from 2mm</li>
<li>'Process-3' from 5mm - 5.5 mm retraction at 41 mm/sec - 0% infill</li>
<li>'Process-4' from 10mm - 6.0 mm retraction at 42 mm/sec - 0% infill</li>
<li>'Process-5' from 15mm - 6.5 mm retraction at 43 mm/sec - 0% infill</li>
<li>'Process-6' from 20mm - 7.0 mm retraction at 44 mm/sec - 0% infill</li>
<li>'Process-7' from 25mm - 7.5 mm retraction at 45 mm/sec - 0% infill</li>
</ul>
<p>Temperature test:</p>
<ul>