cc-mek-scada/reactor-plc/startup.lua

273 lines
8.9 KiB
Lua
Raw Normal View History

--
-- Reactor Programmable Logic Controller
--
require("/initenv").init_env()
local comms = require("scada-common.comms")
local crash = require("scada-common.crash")
local log = require("scada-common.log")
local mqueue = require("scada-common.mqueue")
local ppm = require("scada-common.ppm")
local rsio = require("scada-common.rsio")
local util = require("scada-common.util")
local config = require("reactor-plc.config")
local databus = require("reactor-plc.databus")
local plc = require("reactor-plc.plc")
2023-04-07 02:10:33 +00:00
local renderer = require("reactor-plc.renderer")
local threads = require("reactor-plc.threads")
local R_PLC_VERSION = "v1.3.6"
local println = util.println
local println_ts = util.println_ts
2022-06-05 19:09:02 +00:00
----------------------------------------
-- config validation
----------------------------------------
local cfv = util.new_validator()
cfv.assert_type_bool(config.NETWORKED)
cfv.assert_type_int(config.REACTOR_ID)
cfv.assert_port(config.SERVER_PORT)
cfv.assert_port(config.LISTEN_PORT)
cfv.assert_type_int(config.TRUSTED_RANGE)
cfv.assert_type_num(config.COMMS_TIMEOUT)
2023-02-13 17:29:59 +00:00
cfv.assert_min(config.COMMS_TIMEOUT, 2)
2022-06-05 19:09:02 +00:00
cfv.assert_type_str(config.LOG_PATH)
cfv.assert_type_int(config.LOG_MODE)
2022-06-05 19:09:02 +00:00
assert(cfv.valid(), "bad config file: missing/invalid fields")
-- check emergency coolant configuration
if type(config.EMERGENCY_COOL) == "table" then
if not rsio.is_valid_side(config.EMERGENCY_COOL.side) then
assert(false, "bad config file: emergency coolant side unrecognized")
elseif config.EMERGENCY_COOL.color ~= nil and not rsio.is_color(config.EMERGENCY_COOL.color) then
assert(false, "bad config file: emergency coolant invalid redstone channel color provided")
end
end
2022-06-05 19:09:02 +00:00
----------------------------------------
-- log init
----------------------------------------
log.init(config.LOG_PATH, config.LOG_MODE, config.LOG_DEBUG == true)
log.info("========================================")
log.info("BOOTING reactor-plc.startup " .. R_PLC_VERSION)
log.info("========================================")
println(">> Reactor PLC " .. R_PLC_VERSION .. " <<")
2022-11-13 20:56:27 +00:00
crash.set_env("plc", R_PLC_VERSION)
2022-06-05 19:09:02 +00:00
----------------------------------------
2022-11-13 20:56:27 +00:00
-- main application
2022-06-05 19:09:02 +00:00
----------------------------------------
2022-11-13 20:56:27 +00:00
local function main()
----------------------------------------
-- startup
----------------------------------------
-- record firmware versions and ID
databus.tx_versions(R_PLC_VERSION, comms.version)
databus.tx_id(config.REACTOR_ID)
2022-11-13 20:56:27 +00:00
-- mount connected devices
ppm.mount_all()
-- shared memory across threads
---@class plc_shared_memory
local __shared_memory = {
-- networked setting
networked = config.NETWORKED, ---@type boolean
-- PLC system state flags
---@class plc_state
plc_state = {
init_ok = true,
2023-04-08 04:38:46 +00:00
fp_ok = false,
2022-11-13 20:56:27 +00:00
shutdown = false,
degraded = false,
reactor_formed = true,
no_reactor = false,
no_modem = false
},
-- control setpoints
---@class setpoints
setpoints = {
burn_rate_en = false,
burn_rate = 0.0
},
-- core PLC devices
plc_dev = {
reactor = ppm.get_fission_reactor(),
modem = ppm.get_wireless_modem()
},
-- system objects
plc_sys = {
rps = nil, ---@type rps
plc_comms = nil, ---@type plc_comms
conn_watchdog = nil ---@type watchdog
},
-- message queues
q = {
mq_rps = mqueue.new(),
mq_comms_tx = mqueue.new(),
mq_comms_rx = mqueue.new()
}
2022-04-25 15:40:53 +00:00
}
2022-11-13 20:56:27 +00:00
local smem_dev = __shared_memory.plc_dev
local smem_sys = __shared_memory.plc_sys
2022-11-13 20:56:27 +00:00
local plc_state = __shared_memory.plc_state
2022-11-13 20:56:27 +00:00
-- we need a reactor, can at least do some things even if it isn't formed though
if smem_dev.reactor == nil then
2023-02-22 04:50:43 +00:00
println("init> fission reactor not found");
log.warning("init> no reactor on startup")
2022-11-13 20:56:27 +00:00
plc_state.init_ok = false
plc_state.degraded = true
plc_state.no_reactor = true
elseif not smem_dev.reactor.isFormed() then
2023-02-22 04:50:43 +00:00
println("init> fission reactor not formed");
log.warning("init> reactor logic adapter present, but reactor is not formed")
2022-11-13 20:56:27 +00:00
plc_state.degraded = true
plc_state.reactor_formed = false
2022-04-05 13:41:06 +00:00
end
2022-11-13 20:56:27 +00:00
-- modem is required if networked
if __shared_memory.networked and smem_dev.modem == nil then
2023-02-22 04:50:43 +00:00
println("init> wireless modem not found")
log.warning("init> no wireless modem on startup")
2022-11-13 20:56:27 +00:00
-- scram reactor if present and enabled
if (smem_dev.reactor ~= nil) and plc_state.reactor_formed and smem_dev.reactor.getStatus() then
smem_dev.reactor.scram()
end
2022-11-13 20:56:27 +00:00
plc_state.init_ok = false
plc_state.degraded = true
plc_state.no_modem = true
end
2023-04-08 04:38:46 +00:00
-- print a log message to the terminal as long as the UI isn't running
local function _println_no_fp(message) if not plc_state.fp_ok then println(message) end end
2023-04-08 04:38:46 +00:00
2023-02-21 21:57:33 +00:00
-- PLC init<br>
2022-11-13 20:56:27 +00:00
--- EVENT_CONSUMER: this function consumes events
local function init()
2023-04-08 04:38:46 +00:00
-- just booting up, no fission allowed (neutrons stay put thanks)
if (not plc_state.no_reactor) and plc_state.reactor_formed and smem_dev.reactor.getStatus() then
smem_dev.reactor.scram()
end
2023-04-07 02:10:33 +00:00
2023-04-08 04:38:46 +00:00
-- front panel time!
if not renderer.ui_ready() then
local message
plc_state.fp_ok, message = pcall(renderer.start_ui)
2023-04-08 04:38:46 +00:00
if not plc_state.fp_ok then
renderer.close_ui()
println_ts(util.c("UI error: ", message))
println("init> running without front panel")
log.error(util.c("GUI crashed with error ", message))
log.info("init> running in headless mode without front panel")
2022-11-13 20:56:27 +00:00
end
2023-04-08 04:38:46 +00:00
end
2022-11-13 20:56:27 +00:00
2023-04-08 04:38:46 +00:00
if plc_state.init_ok then
2022-11-13 20:56:27 +00:00
-- init reactor protection system
smem_sys.rps = plc.rps_init(smem_dev.reactor, plc_state.reactor_formed, config.EMERGENCY_COOL)
2022-11-13 20:56:27 +00:00
log.debug("init> rps init")
if __shared_memory.networked then
-- comms watchdog
smem_sys.conn_watchdog = util.new_watchdog(config.COMMS_TIMEOUT)
2022-11-13 20:56:27 +00:00
log.debug("init> conn watchdog started")
-- start comms
smem_sys.plc_comms = plc.comms(config.REACTOR_ID, R_PLC_VERSION, smem_dev.modem, config.LISTEN_PORT, config.SERVER_PORT,
config.TRUSTED_RANGE, smem_dev.reactor, smem_sys.rps, smem_sys.conn_watchdog)
2022-11-13 20:56:27 +00:00
log.debug("init> comms init")
else
_println_no_fp("init> starting in offline mode")
2023-02-21 21:57:33 +00:00
log.info("init> running without networking")
2022-11-13 20:56:27 +00:00
end
-- notify user of emergency coolant configuration status
if config.EMERGENCY_COOL ~= nil then
println("init> emergency coolant control ready")
log.info("init> running with emergency coolant control available")
end
2022-11-13 20:56:27 +00:00
util.push_event("clock_start")
_println_no_fp("init> completed")
2023-02-22 04:50:43 +00:00
log.info("init> startup completed")
else
_println_no_fp("init> system in degraded state, awaiting devices...")
2023-02-22 04:50:43 +00:00
log.warning("init> started in a degraded state, awaiting peripheral connections...")
end
2023-04-08 04:38:46 +00:00
databus.tx_hw_status(plc_state)
end
2022-11-13 20:56:27 +00:00
----------------------------------------
-- start system
----------------------------------------
2022-11-13 20:56:27 +00:00
-- initialize PLC
init()
2022-11-13 20:56:27 +00:00
-- init threads
local main_thread = threads.thread__main(__shared_memory, init)
local rps_thread = threads.thread__rps(__shared_memory)
2022-11-13 20:56:27 +00:00
if __shared_memory.networked then
-- init comms threads
local comms_thread_tx = threads.thread__comms_tx(__shared_memory)
local comms_thread_rx = threads.thread__comms_rx(__shared_memory)
2022-11-13 20:56:27 +00:00
-- setpoint control only needed when networked
local sp_ctrl_thread = threads.thread__setpoint_control(__shared_memory)
2022-04-30 02:27:54 +00:00
2022-11-13 20:56:27 +00:00
-- run threads
parallel.waitForAll(main_thread.p_exec, rps_thread.p_exec, comms_thread_tx.p_exec, comms_thread_rx.p_exec, sp_ctrl_thread.p_exec)
2022-11-13 20:56:27 +00:00
if plc_state.init_ok then
-- send status one last time after RPS shutdown
smem_sys.plc_comms.send_status(plc_state.no_reactor, plc_state.reactor_formed)
smem_sys.plc_comms.send_rps_status()
2022-11-13 20:56:27 +00:00
-- close connection
smem_sys.plc_comms.close()
end
else
-- run threads, excluding comms
parallel.waitForAll(main_thread.p_exec, rps_thread.p_exec)
end
2022-11-13 20:56:27 +00:00
2023-04-07 02:10:33 +00:00
renderer.close_ui()
2022-11-13 20:56:27 +00:00
println_ts("exited")
log.info("exited")
end
2023-04-21 01:19:16 +00:00
if not xpcall(main, crash.handler) then
pcall(renderer.close_ui)
crash.exit()
else
log.close()
end