2022-12-06 16:40:13 +00:00
|
|
|
local comms = require("scada-common.comms")
|
|
|
|
local log = require("scada-common.log")
|
|
|
|
local ppm = require("scada-common.ppm")
|
|
|
|
local util = require("scada-common.util")
|
2022-06-25 17:39:47 +00:00
|
|
|
|
|
|
|
local apisessions = require("coordinator.apisessions")
|
2022-09-07 02:38:27 +00:00
|
|
|
local iocontrol = require("coordinator.iocontrol")
|
2023-01-26 23:26:26 +00:00
|
|
|
local process = require("coordinator.process")
|
2022-05-29 18:34:09 +00:00
|
|
|
|
2022-12-06 16:40:13 +00:00
|
|
|
local dialog = require("coordinator.ui.dialog")
|
2022-06-15 19:35:34 +00:00
|
|
|
|
2022-05-29 18:34:09 +00:00
|
|
|
local print = util.print
|
|
|
|
local println = util.println
|
|
|
|
local print_ts = util.print_ts
|
|
|
|
local println_ts = util.println_ts
|
2022-03-25 16:17:46 +00:00
|
|
|
|
2023-02-21 16:05:57 +00:00
|
|
|
local PROTOCOL = comms.PROTOCOL
|
|
|
|
local DEVICE_TYPE = comms.DEVICE_TYPE
|
2022-11-13 19:13:30 +00:00
|
|
|
local ESTABLISH_ACK = comms.ESTABLISH_ACK
|
2023-02-21 16:05:57 +00:00
|
|
|
local SCADA_MGMT_TYPE = comms.SCADA_MGMT_TYPE
|
|
|
|
local SCADA_CRDN_TYPE = comms.SCADA_CRDN_TYPE
|
|
|
|
local UNIT_COMMAND = comms.UNIT_COMMAND
|
|
|
|
local FAC_COMMAND = comms.FAC_COMMAND
|
2022-05-10 21:09:02 +00:00
|
|
|
|
2022-12-06 16:40:13 +00:00
|
|
|
local coordinator = {}
|
|
|
|
|
2022-06-15 19:35:34 +00:00
|
|
|
-- request the user to select a monitor
|
2023-02-23 04:09:47 +00:00
|
|
|
---@nodiscard
|
2022-06-15 19:35:34 +00:00
|
|
|
---@param names table available monitors
|
2022-09-21 19:53:51 +00:00
|
|
|
---@return boolean|string|nil
|
2022-05-29 18:34:09 +00:00
|
|
|
local function ask_monitor(names)
|
|
|
|
println("available monitors:")
|
|
|
|
for i = 1, #names do
|
|
|
|
print(" " .. names[i])
|
|
|
|
end
|
|
|
|
println("")
|
|
|
|
println("select a monitor or type c to cancel")
|
|
|
|
|
|
|
|
local iface = dialog.ask_options(names, "c")
|
|
|
|
|
|
|
|
if iface ~= false and iface ~= nil then
|
|
|
|
util.filter_table(names, function (x) return x ~= iface end)
|
|
|
|
end
|
|
|
|
|
|
|
|
return iface
|
|
|
|
end
|
|
|
|
|
2022-06-15 19:35:34 +00:00
|
|
|
-- configure monitor layout
|
|
|
|
---@param num_units integer number of units expected
|
2023-03-04 17:27:38 +00:00
|
|
|
---@return boolean success, monitors_struct? monitors
|
2022-05-29 18:34:09 +00:00
|
|
|
function coordinator.configure_monitors(num_units)
|
|
|
|
---@class monitors_struct
|
|
|
|
local monitors = {
|
|
|
|
primary = nil,
|
2022-07-20 17:28:58 +00:00
|
|
|
primary_name = "",
|
|
|
|
unit_displays = {},
|
|
|
|
unit_name_map = {}
|
2022-05-29 18:34:09 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
local monitors_avail = ppm.get_monitor_list()
|
|
|
|
local names = {}
|
2023-03-04 17:27:38 +00:00
|
|
|
local available = {}
|
2022-05-29 18:34:09 +00:00
|
|
|
|
|
|
|
-- get all interface names
|
|
|
|
for iface, _ in pairs(monitors_avail) do
|
|
|
|
table.insert(names, iface)
|
2023-03-04 17:27:38 +00:00
|
|
|
table.insert(available, iface)
|
2022-05-29 18:34:09 +00:00
|
|
|
end
|
|
|
|
|
|
|
|
-- we need a certain number of monitors (1 per unit + 1 primary display)
|
2023-02-23 04:09:47 +00:00
|
|
|
local num_displays_needed = num_units + 1
|
|
|
|
if #names < num_displays_needed then
|
|
|
|
local message = "not enough monitors connected (need " .. num_displays_needed .. ")"
|
|
|
|
println(message)
|
|
|
|
log.warning(message)
|
2022-05-29 18:34:09 +00:00
|
|
|
return false
|
|
|
|
end
|
|
|
|
|
|
|
|
-- attempt to load settings
|
2023-01-24 01:47:45 +00:00
|
|
|
if not settings.load("/coord.settings") then
|
|
|
|
log.warning("configure_monitors(): failed to load coordinator settings file (may not exist yet)")
|
2023-03-04 17:27:38 +00:00
|
|
|
else
|
|
|
|
local _primary = settings.get("PRIMARY_DISPLAY")
|
|
|
|
local _unitd = settings.get("UNIT_DISPLAYS")
|
|
|
|
|
|
|
|
-- filter out already assigned monitors
|
|
|
|
util.filter_table(available, function (x) return x ~= _primary end)
|
|
|
|
if type(_unitd) == "table" then
|
|
|
|
util.filter_table(available, function (x) return not util.table_contains(_unitd, x) end)
|
|
|
|
end
|
2023-01-24 01:47:45 +00:00
|
|
|
end
|
2022-05-29 18:34:09 +00:00
|
|
|
|
|
|
|
---------------------
|
|
|
|
-- PRIMARY DISPLAY --
|
|
|
|
---------------------
|
|
|
|
|
2022-09-21 19:53:51 +00:00
|
|
|
local iface_primary_display = settings.get("PRIMARY_DISPLAY") ---@type boolean|string|nil
|
2022-05-29 18:34:09 +00:00
|
|
|
|
|
|
|
if not util.table_contains(names, iface_primary_display) then
|
|
|
|
println("primary display is not connected")
|
|
|
|
local response = dialog.ask_y_n("would you like to change it", true)
|
|
|
|
if response == false then return false end
|
|
|
|
iface_primary_display = nil
|
|
|
|
end
|
|
|
|
|
2023-03-04 17:27:38 +00:00
|
|
|
while iface_primary_display == nil and #available > 0 do
|
2022-05-29 18:34:09 +00:00
|
|
|
-- lets get a monitor
|
2023-03-04 17:27:38 +00:00
|
|
|
iface_primary_display = ask_monitor(available)
|
2022-05-29 18:34:09 +00:00
|
|
|
end
|
|
|
|
|
2022-09-21 19:53:51 +00:00
|
|
|
if type(iface_primary_display) ~= "string" then return false end
|
2022-05-29 18:34:09 +00:00
|
|
|
|
|
|
|
settings.set("PRIMARY_DISPLAY", iface_primary_display)
|
2023-03-04 17:27:38 +00:00
|
|
|
util.filter_table(available, function (x) return x ~= iface_primary_display end)
|
2022-05-29 18:34:09 +00:00
|
|
|
|
|
|
|
monitors.primary = ppm.get_periph(iface_primary_display)
|
2022-07-20 17:28:58 +00:00
|
|
|
monitors.primary_name = iface_primary_display
|
2022-05-29 18:34:09 +00:00
|
|
|
|
|
|
|
-------------------
|
|
|
|
-- UNIT DISPLAYS --
|
|
|
|
-------------------
|
|
|
|
|
|
|
|
local unit_displays = settings.get("UNIT_DISPLAYS")
|
|
|
|
|
|
|
|
if unit_displays == nil then
|
|
|
|
unit_displays = {}
|
|
|
|
for i = 1, num_units do
|
|
|
|
local display = nil
|
|
|
|
|
2023-03-04 17:27:38 +00:00
|
|
|
while display == nil and #available > 0 do
|
2022-05-29 18:34:09 +00:00
|
|
|
-- lets get a monitor
|
2023-03-03 03:29:50 +00:00
|
|
|
println("please select monitor for unit #" .. i)
|
2023-03-04 17:27:38 +00:00
|
|
|
display = ask_monitor(available)
|
2022-05-29 18:34:09 +00:00
|
|
|
end
|
|
|
|
|
|
|
|
if display == false then return false end
|
|
|
|
|
|
|
|
unit_displays[i] = display
|
|
|
|
end
|
|
|
|
else
|
|
|
|
-- make sure all displays are connected
|
|
|
|
for i = 1, num_units do
|
|
|
|
local display = unit_displays[i]
|
|
|
|
|
|
|
|
if not util.table_contains(names, display) then
|
2023-03-03 03:29:50 +00:00
|
|
|
println("unit #" .. i .. " display is not connected")
|
|
|
|
local response = dialog.ask_y_n("would you like to change it", true)
|
2022-05-29 18:34:09 +00:00
|
|
|
if response == false then return false end
|
|
|
|
display = nil
|
|
|
|
end
|
|
|
|
|
2023-03-04 17:27:38 +00:00
|
|
|
while display == nil and #available > 0 do
|
2022-05-29 18:34:09 +00:00
|
|
|
-- lets get a monitor
|
2023-03-04 17:27:38 +00:00
|
|
|
display = ask_monitor(available)
|
2022-05-29 18:34:09 +00:00
|
|
|
end
|
|
|
|
|
|
|
|
if display == false then return false end
|
|
|
|
|
|
|
|
unit_displays[i] = display
|
|
|
|
end
|
|
|
|
end
|
|
|
|
|
|
|
|
settings.set("UNIT_DISPLAYS", unit_displays)
|
2023-01-24 01:47:45 +00:00
|
|
|
if not settings.save("/coord.settings") then
|
|
|
|
log.warning("configure_monitors(): failed to save coordinator settings file")
|
|
|
|
end
|
2022-05-29 18:34:09 +00:00
|
|
|
|
|
|
|
for i = 1, #unit_displays do
|
|
|
|
monitors.unit_displays[i] = ppm.get_periph(unit_displays[i])
|
2022-07-20 17:28:58 +00:00
|
|
|
monitors.unit_name_map[i] = unit_displays[i]
|
2022-05-29 18:34:09 +00:00
|
|
|
end
|
|
|
|
|
|
|
|
return true, monitors
|
|
|
|
end
|
|
|
|
|
2022-07-05 15:18:26 +00:00
|
|
|
-- dmesg print wrapper
|
|
|
|
---@param message string message
|
|
|
|
---@param dmesg_tag string tag
|
2022-07-06 03:48:01 +00:00
|
|
|
---@param working? boolean to use dmesg_working
|
|
|
|
---@return function? update, function? done
|
|
|
|
local function log_dmesg(message, dmesg_tag, working)
|
2022-07-05 15:18:26 +00:00
|
|
|
local colors = {
|
|
|
|
GRAPHICS = colors.green,
|
|
|
|
SYSTEM = colors.cyan,
|
|
|
|
BOOT = colors.blue,
|
|
|
|
COMMS = colors.purple
|
|
|
|
}
|
|
|
|
|
2022-07-06 03:48:01 +00:00
|
|
|
if working then
|
|
|
|
return log.dmesg_working(message, dmesg_tag, colors[dmesg_tag])
|
|
|
|
else
|
|
|
|
log.dmesg(message, dmesg_tag, colors[dmesg_tag])
|
|
|
|
end
|
2022-07-05 15:18:26 +00:00
|
|
|
end
|
|
|
|
|
|
|
|
function coordinator.log_graphics(message) log_dmesg(message, "GRAPHICS") end
|
|
|
|
function coordinator.log_sys(message) log_dmesg(message, "SYSTEM") end
|
|
|
|
function coordinator.log_boot(message) log_dmesg(message, "BOOT") end
|
|
|
|
function coordinator.log_comms(message) log_dmesg(message, "COMMS") end
|
|
|
|
|
2023-02-23 04:09:47 +00:00
|
|
|
-- log a message for communications connecting, providing access to progress indication control functions
|
|
|
|
---@nodiscard
|
2022-07-06 03:48:01 +00:00
|
|
|
---@param message string
|
|
|
|
---@return function update, function done
|
2022-09-21 19:53:51 +00:00
|
|
|
function coordinator.log_comms_connecting(message)
|
2023-02-23 04:09:47 +00:00
|
|
|
local update, done = log_dmesg(message, "COMMS", true)
|
|
|
|
---@cast update function
|
|
|
|
---@cast done function
|
|
|
|
return update, done
|
2022-09-21 19:53:51 +00:00
|
|
|
end
|
2022-07-06 03:48:01 +00:00
|
|
|
|
2022-03-25 16:17:46 +00:00
|
|
|
-- coordinator communications
|
2023-02-23 04:09:47 +00:00
|
|
|
---@nodiscard
|
2023-02-07 22:31:22 +00:00
|
|
|
---@param version string coordinator version
|
|
|
|
---@param modem table modem device
|
|
|
|
---@param sv_port integer port of configured supervisor
|
|
|
|
---@param sv_listen integer listening port for supervisor replys
|
|
|
|
---@param api_listen integer listening port for pocket API
|
|
|
|
---@param range integer trusted device connection range
|
2022-06-25 17:39:47 +00:00
|
|
|
---@param sv_watchdog watchdog
|
2023-02-07 22:31:22 +00:00
|
|
|
function coordinator.comms(version, modem, sv_port, sv_listen, api_listen, range, sv_watchdog)
|
2022-03-25 16:17:46 +00:00
|
|
|
local self = {
|
2022-07-06 03:48:01 +00:00
|
|
|
sv_linked = false,
|
2022-06-25 17:39:47 +00:00
|
|
|
sv_seq_num = 0,
|
|
|
|
sv_r_seq_num = nil,
|
2023-03-03 03:29:50 +00:00
|
|
|
sv_config_err = false,
|
2023-02-16 00:59:58 +00:00
|
|
|
connected = false,
|
|
|
|
last_est_ack = ESTABLISH_ACK.ALLOW
|
2022-03-25 16:17:46 +00:00
|
|
|
}
|
2022-06-15 19:35:34 +00:00
|
|
|
|
2023-02-07 22:31:22 +00:00
|
|
|
comms.set_trusted_range(range)
|
|
|
|
|
2022-06-15 19:35:34 +00:00
|
|
|
-- PRIVATE FUNCTIONS --
|
|
|
|
|
2022-09-23 00:42:06 +00:00
|
|
|
-- configure modem channels
|
|
|
|
local function _conf_channels()
|
2023-02-23 04:09:47 +00:00
|
|
|
modem.closeAll()
|
|
|
|
modem.open(sv_listen)
|
|
|
|
modem.open(api_listen)
|
2022-06-15 19:35:34 +00:00
|
|
|
end
|
|
|
|
|
2022-09-23 00:42:06 +00:00
|
|
|
_conf_channels()
|
2022-06-15 19:35:34 +00:00
|
|
|
|
2022-06-25 17:39:47 +00:00
|
|
|
-- send a packet to the supervisor
|
2023-02-21 16:05:57 +00:00
|
|
|
---@param msg_type SCADA_MGMT_TYPE|SCADA_CRDN_TYPE
|
2022-06-25 17:39:47 +00:00
|
|
|
---@param msg table
|
|
|
|
local function _send_sv(protocol, msg_type, msg)
|
2022-06-15 19:35:34 +00:00
|
|
|
local s_pkt = comms.scada_packet()
|
2022-07-07 04:34:42 +00:00
|
|
|
local pkt = nil ---@type mgmt_packet|crdn_packet
|
2022-06-25 17:39:47 +00:00
|
|
|
|
2023-02-21 16:05:57 +00:00
|
|
|
if protocol == PROTOCOL.SCADA_MGMT then
|
2022-06-25 17:39:47 +00:00
|
|
|
pkt = comms.mgmt_packet()
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif protocol == PROTOCOL.SCADA_CRDN then
|
2022-07-07 04:34:42 +00:00
|
|
|
pkt = comms.crdn_packet()
|
2022-06-25 17:39:47 +00:00
|
|
|
else
|
|
|
|
return
|
|
|
|
end
|
2022-06-15 19:35:34 +00:00
|
|
|
|
2022-06-25 17:39:47 +00:00
|
|
|
pkt.make(msg_type, msg)
|
|
|
|
s_pkt.make(self.sv_seq_num, protocol, pkt.raw_sendable())
|
2022-06-15 19:35:34 +00:00
|
|
|
|
2023-02-23 04:09:47 +00:00
|
|
|
modem.transmit(sv_port, sv_listen, s_pkt.raw_sendable())
|
2022-06-25 17:39:47 +00:00
|
|
|
self.sv_seq_num = self.sv_seq_num + 1
|
2022-06-15 19:35:34 +00:00
|
|
|
end
|
|
|
|
|
2022-07-07 04:34:42 +00:00
|
|
|
-- attempt connection establishment
|
|
|
|
local function _send_establish()
|
2023-02-21 16:05:57 +00:00
|
|
|
_send_sv(PROTOCOL.SCADA_MGMT, SCADA_MGMT_TYPE.ESTABLISH, { comms.version, version, DEVICE_TYPE.CRDN })
|
2022-07-07 04:34:42 +00:00
|
|
|
end
|
|
|
|
|
|
|
|
-- keep alive ack
|
|
|
|
---@param srv_time integer
|
|
|
|
local function _send_keep_alive_ack(srv_time)
|
2023-02-21 16:05:57 +00:00
|
|
|
_send_sv(PROTOCOL.SCADA_MGMT, SCADA_MGMT_TYPE.KEEP_ALIVE, { srv_time, util.time() })
|
2022-07-07 04:34:42 +00:00
|
|
|
end
|
|
|
|
|
2022-06-15 19:35:34 +00:00
|
|
|
-- PUBLIC FUNCTIONS --
|
|
|
|
|
2023-02-23 04:09:47 +00:00
|
|
|
---@class coord_comms
|
|
|
|
local public = {}
|
|
|
|
|
2022-06-15 19:35:34 +00:00
|
|
|
-- reconnect a newly connected modem
|
2023-02-23 04:09:47 +00:00
|
|
|
---@param new_modem table
|
|
|
|
function public.reconnect_modem(new_modem)
|
|
|
|
modem = new_modem
|
2022-09-23 00:42:06 +00:00
|
|
|
_conf_channels()
|
2022-06-15 19:35:34 +00:00
|
|
|
end
|
|
|
|
|
2022-07-20 17:28:58 +00:00
|
|
|
-- close the connection to the server
|
|
|
|
function public.close()
|
|
|
|
sv_watchdog.cancel()
|
2022-09-13 20:07:21 +00:00
|
|
|
self.sv_linked = false
|
2023-02-21 16:05:57 +00:00
|
|
|
_send_sv(PROTOCOL.SCADA_MGMT, SCADA_MGMT_TYPE.CLOSE, {})
|
2022-07-20 17:28:58 +00:00
|
|
|
end
|
|
|
|
|
2022-07-06 03:48:01 +00:00
|
|
|
-- attempt to connect to the subervisor
|
2023-02-23 04:09:47 +00:00
|
|
|
---@nodiscard
|
2022-07-06 03:48:01 +00:00
|
|
|
---@param timeout_s number timeout in seconds
|
|
|
|
---@param tick_dmesg_waiting function callback to tick dmesg waiting
|
|
|
|
---@param task_done function callback to show done on dmesg
|
|
|
|
---@return boolean sv_linked true if connected, false otherwise
|
|
|
|
--- EVENT_CONSUMER: this function consumes events
|
|
|
|
function public.sv_connect(timeout_s, tick_dmesg_waiting, task_done)
|
|
|
|
local clock = util.new_clock(1)
|
|
|
|
local start = util.time_s()
|
|
|
|
local terminated = false
|
|
|
|
|
2022-07-07 04:34:42 +00:00
|
|
|
_send_establish()
|
2022-07-06 03:48:01 +00:00
|
|
|
|
|
|
|
clock.start()
|
|
|
|
|
2023-03-03 03:29:50 +00:00
|
|
|
while (util.time_s() - start) < timeout_s and (not self.sv_linked) and (not self.sv_config_err) do
|
2022-07-19 19:18:11 +00:00
|
|
|
local event, p1, p2, p3, p4, p5 = util.pull_event()
|
2022-07-06 03:48:01 +00:00
|
|
|
|
|
|
|
if event == "timer" and clock.is_clock(p1) then
|
|
|
|
-- timed out attempt, try again
|
|
|
|
tick_dmesg_waiting(math.max(0, timeout_s - (util.time_s() - start)))
|
2022-07-07 04:34:42 +00:00
|
|
|
_send_establish()
|
2022-07-06 03:48:01 +00:00
|
|
|
clock.start()
|
|
|
|
elseif event == "modem_message" then
|
|
|
|
-- handle message
|
|
|
|
local packet = public.parse_packet(p1, p2, p3, p4, p5)
|
2023-02-21 16:05:57 +00:00
|
|
|
if packet ~= nil and packet.type == SCADA_MGMT_TYPE.ESTABLISH then
|
2022-07-06 03:48:01 +00:00
|
|
|
public.handle_packet(packet)
|
|
|
|
end
|
|
|
|
elseif event == "terminate" then
|
|
|
|
terminated = true
|
|
|
|
break
|
|
|
|
end
|
|
|
|
end
|
|
|
|
|
2022-07-06 03:49:48 +00:00
|
|
|
task_done(self.sv_linked)
|
|
|
|
|
|
|
|
if terminated then
|
|
|
|
coordinator.log_comms("supervisor connection attempt cancelled by user")
|
2023-03-03 03:29:50 +00:00
|
|
|
elseif self.sv_config_err then
|
|
|
|
coordinator.log_comms("supervisor cooling configuration invalid, check supervisor config file")
|
2023-02-16 00:59:58 +00:00
|
|
|
elseif not self.sv_linked then
|
|
|
|
if self.last_est_ack == ESTABLISH_ACK.DENY then
|
|
|
|
coordinator.log_comms("supervisor connection attempt denied")
|
|
|
|
elseif self.last_est_ack == ESTABLISH_ACK.COLLISION then
|
|
|
|
coordinator.log_comms("supervisor connection failed due to collision")
|
|
|
|
elseif self.last_est_ack == ESTABLISH_ACK.BAD_VERSION then
|
|
|
|
coordinator.log_comms("supervisor connection failed due to version mismatch")
|
|
|
|
else
|
|
|
|
coordinator.log_comms("supervisor connection failed with no valid response")
|
|
|
|
end
|
2022-07-06 03:48:01 +00:00
|
|
|
end
|
|
|
|
|
|
|
|
return self.sv_linked
|
|
|
|
end
|
|
|
|
|
2023-01-26 23:26:26 +00:00
|
|
|
-- send a facility command
|
2023-02-21 16:05:57 +00:00
|
|
|
---@param cmd FAC_COMMAND command
|
2023-01-26 23:26:26 +00:00
|
|
|
function public.send_fac_command(cmd)
|
2023-02-21 16:05:57 +00:00
|
|
|
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.FAC_CMD, { cmd })
|
2023-01-26 23:26:26 +00:00
|
|
|
end
|
|
|
|
|
|
|
|
-- send the auto process control configuration with a start command
|
|
|
|
---@param config coord_auto_config configuration
|
|
|
|
function public.send_auto_start(config)
|
2023-02-21 16:05:57 +00:00
|
|
|
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.FAC_CMD, {
|
|
|
|
FAC_COMMAND.START, config.mode, config.burn_target, config.charge_target, config.gen_target, config.limits
|
2023-01-26 23:26:26 +00:00
|
|
|
})
|
|
|
|
end
|
|
|
|
|
2022-09-21 19:53:51 +00:00
|
|
|
-- send a unit command
|
2023-02-21 16:05:57 +00:00
|
|
|
---@param cmd UNIT_COMMAND command
|
2022-10-20 16:22:03 +00:00
|
|
|
---@param unit integer unit ID
|
2023-01-26 23:26:26 +00:00
|
|
|
---@param option any? optional option options for the optional options (like burn rate) (does option still look like a word?)
|
|
|
|
function public.send_unit_command(cmd, unit, option)
|
2023-02-21 16:05:57 +00:00
|
|
|
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.UNIT_CMD, { cmd, unit, option })
|
2022-09-21 19:53:51 +00:00
|
|
|
end
|
|
|
|
|
2022-06-15 19:35:34 +00:00
|
|
|
-- parse a packet
|
|
|
|
---@param side string
|
|
|
|
---@param sender integer
|
|
|
|
---@param reply_to integer
|
|
|
|
---@param message any
|
|
|
|
---@param distance integer
|
2022-07-07 04:34:42 +00:00
|
|
|
---@return mgmt_frame|crdn_frame|capi_frame|nil packet
|
2022-06-15 19:35:34 +00:00
|
|
|
function public.parse_packet(side, sender, reply_to, message, distance)
|
|
|
|
local pkt = nil
|
|
|
|
local s_pkt = comms.scada_packet()
|
|
|
|
|
|
|
|
-- parse packet as generic SCADA packet
|
|
|
|
s_pkt.receive(side, sender, reply_to, message, distance)
|
|
|
|
|
|
|
|
if s_pkt.is_valid() then
|
|
|
|
-- get as SCADA management packet
|
2023-02-21 16:05:57 +00:00
|
|
|
if s_pkt.protocol() == PROTOCOL.SCADA_MGMT then
|
2022-06-15 19:35:34 +00:00
|
|
|
local mgmt_pkt = comms.mgmt_packet()
|
|
|
|
if mgmt_pkt.decode(s_pkt) then
|
|
|
|
pkt = mgmt_pkt.get()
|
|
|
|
end
|
|
|
|
-- get as coordinator packet
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif s_pkt.protocol() == PROTOCOL.SCADA_CRDN then
|
2022-07-07 04:34:42 +00:00
|
|
|
local crdn_pkt = comms.crdn_packet()
|
|
|
|
if crdn_pkt.decode(s_pkt) then
|
|
|
|
pkt = crdn_pkt.get()
|
2022-06-15 19:35:34 +00:00
|
|
|
end
|
|
|
|
-- get as coordinator API packet
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif s_pkt.protocol() == PROTOCOL.COORD_API then
|
2022-06-15 19:35:34 +00:00
|
|
|
local capi_pkt = comms.capi_packet()
|
|
|
|
if capi_pkt.decode(s_pkt) then
|
|
|
|
pkt = capi_pkt.get()
|
|
|
|
end
|
|
|
|
else
|
|
|
|
log.debug("attempted parse of illegal packet type " .. s_pkt.protocol(), true)
|
|
|
|
end
|
|
|
|
end
|
|
|
|
|
|
|
|
return pkt
|
|
|
|
end
|
|
|
|
|
|
|
|
-- handle a packet
|
2022-09-21 19:53:51 +00:00
|
|
|
---@param packet mgmt_frame|crdn_frame|capi_frame|nil
|
2022-06-15 19:35:34 +00:00
|
|
|
function public.handle_packet(packet)
|
|
|
|
if packet ~= nil then
|
|
|
|
local protocol = packet.scada_frame.protocol()
|
2022-09-23 00:42:06 +00:00
|
|
|
local l_port = packet.scada_frame.local_port()
|
2022-06-15 19:35:34 +00:00
|
|
|
|
2022-09-23 00:42:06 +00:00
|
|
|
if l_port == api_listen then
|
2023-02-21 16:05:57 +00:00
|
|
|
if protocol == PROTOCOL.COORD_API then
|
2023-02-23 04:09:47 +00:00
|
|
|
---@cast packet capi_frame
|
2022-09-23 00:42:06 +00:00
|
|
|
apisessions.handle_packet(packet)
|
|
|
|
else
|
|
|
|
log.debug("illegal packet type " .. protocol .. " on api listening channel", true)
|
|
|
|
end
|
|
|
|
elseif l_port == sv_listen then
|
2022-06-25 17:39:47 +00:00
|
|
|
-- check sequence number
|
|
|
|
if self.sv_r_seq_num == nil then
|
|
|
|
self.sv_r_seq_num = packet.scada_frame.seq_num()
|
|
|
|
elseif self.connected and self.sv_r_seq_num >= packet.scada_frame.seq_num() then
|
|
|
|
log.warning("sequence out-of-order: last = " .. self.sv_r_seq_num .. ", new = " .. packet.scada_frame.seq_num())
|
|
|
|
return
|
2022-06-15 19:35:34 +00:00
|
|
|
else
|
2022-06-25 17:39:47 +00:00
|
|
|
self.sv_r_seq_num = packet.scada_frame.seq_num()
|
2022-06-15 19:35:34 +00:00
|
|
|
end
|
2022-06-25 17:39:47 +00:00
|
|
|
|
|
|
|
-- feed watchdog on valid sequence number
|
|
|
|
sv_watchdog.feed()
|
|
|
|
|
|
|
|
-- handle packet
|
2023-02-21 16:05:57 +00:00
|
|
|
if protocol == PROTOCOL.SCADA_CRDN then
|
2023-02-23 04:09:47 +00:00
|
|
|
---@cast packet crdn_frame
|
2022-11-13 19:13:30 +00:00
|
|
|
if self.sv_linked then
|
2023-02-21 16:05:57 +00:00
|
|
|
if packet.type == SCADA_CRDN_TYPE.INITIAL_BUILDS then
|
2023-02-20 19:50:20 +00:00
|
|
|
if packet.length == 2 then
|
|
|
|
-- record builds
|
|
|
|
local fac_builds = iocontrol.record_facility_builds(packet.data[1])
|
|
|
|
local unit_builds = iocontrol.record_unit_builds(packet.data[2])
|
|
|
|
|
|
|
|
if fac_builds and unit_builds then
|
|
|
|
-- acknowledge receipt of builds
|
2023-02-21 16:05:57 +00:00
|
|
|
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.INITIAL_BUILDS, {})
|
2023-02-20 19:50:20 +00:00
|
|
|
else
|
2023-02-23 04:09:47 +00:00
|
|
|
log.debug("received invalid INITIAL_BUILDS packet")
|
2023-02-20 19:50:20 +00:00
|
|
|
end
|
|
|
|
else
|
|
|
|
log.debug("INITIAL_BUILDS packet length mismatch")
|
|
|
|
end
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif packet.type == SCADA_CRDN_TYPE.FAC_BUILDS then
|
2022-12-10 20:44:11 +00:00
|
|
|
if packet.length == 1 then
|
|
|
|
-- record facility builds
|
|
|
|
if iocontrol.record_facility_builds(packet.data[1]) then
|
|
|
|
-- acknowledge receipt of builds
|
2023-02-21 16:05:57 +00:00
|
|
|
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.FAC_BUILDS, {})
|
2022-12-10 20:44:11 +00:00
|
|
|
else
|
2023-02-23 04:09:47 +00:00
|
|
|
log.debug("received invalid FAC_BUILDS packet")
|
2022-12-10 20:44:11 +00:00
|
|
|
end
|
2022-12-10 18:58:17 +00:00
|
|
|
else
|
2022-12-10 20:44:11 +00:00
|
|
|
log.debug("FAC_BUILDS packet length mismatch")
|
2022-12-10 18:58:17 +00:00
|
|
|
end
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif packet.type == SCADA_CRDN_TYPE.FAC_STATUS then
|
2022-12-10 18:58:17 +00:00
|
|
|
-- update facility status
|
|
|
|
if not iocontrol.update_facility_status(packet.data) then
|
2023-02-23 04:09:47 +00:00
|
|
|
log.debug("received invalid FAC_STATUS packet")
|
2022-12-10 18:58:17 +00:00
|
|
|
end
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif packet.type == SCADA_CRDN_TYPE.FAC_CMD then
|
2022-12-10 18:58:17 +00:00
|
|
|
-- facility command acknowledgement
|
2023-01-26 23:26:26 +00:00
|
|
|
if packet.length >= 2 then
|
|
|
|
local cmd = packet.data[1]
|
|
|
|
local ack = packet.data[2] == true
|
|
|
|
|
2023-02-21 16:05:57 +00:00
|
|
|
if cmd == FAC_COMMAND.SCRAM_ALL then
|
2023-01-26 23:26:26 +00:00
|
|
|
iocontrol.get_db().facility.scram_ack(ack)
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif cmd == FAC_COMMAND.STOP then
|
2023-01-26 23:26:26 +00:00
|
|
|
iocontrol.get_db().facility.stop_ack(ack)
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif cmd == FAC_COMMAND.START then
|
2023-01-26 23:26:26 +00:00
|
|
|
if packet.length == 7 then
|
|
|
|
process.start_ack_handle({ table.unpack(packet.data, 2) })
|
|
|
|
else
|
|
|
|
log.debug("SCADA_CRDN process start (with configuration) ack echo packet length mismatch")
|
|
|
|
end
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif cmd == FAC_COMMAND.ACK_ALL_ALARMS then
|
2023-02-07 23:44:34 +00:00
|
|
|
iocontrol.get_db().facility.ack_alarms_ack(ack)
|
2023-01-26 23:26:26 +00:00
|
|
|
else
|
|
|
|
log.debug(util.c("received facility command ack with unknown command ", cmd))
|
|
|
|
end
|
|
|
|
else
|
|
|
|
log.debug("SCADA_CRDN facility command ack packet length mismatch")
|
|
|
|
end
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif packet.type == SCADA_CRDN_TYPE.UNIT_BUILDS then
|
2022-11-13 19:13:30 +00:00
|
|
|
-- record builds
|
2023-02-20 05:49:37 +00:00
|
|
|
if packet.length == 1 then
|
|
|
|
if iocontrol.record_unit_builds(packet.data[1]) then
|
|
|
|
-- acknowledge receipt of builds
|
2023-02-21 16:05:57 +00:00
|
|
|
_send_sv(PROTOCOL.SCADA_CRDN, SCADA_CRDN_TYPE.UNIT_BUILDS, {})
|
2023-02-20 05:49:37 +00:00
|
|
|
else
|
2023-02-23 04:09:47 +00:00
|
|
|
log.debug("received invalid UNIT_BUILDS packet")
|
2023-02-20 05:49:37 +00:00
|
|
|
end
|
2022-07-06 03:48:01 +00:00
|
|
|
else
|
2023-02-20 05:49:37 +00:00
|
|
|
log.debug("UNIT_BUILDS packet length mismatch")
|
2022-07-06 03:48:01 +00:00
|
|
|
end
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif packet.type == SCADA_CRDN_TYPE.UNIT_STATUSES then
|
2022-11-13 19:13:30 +00:00
|
|
|
-- update statuses
|
2022-12-10 18:58:17 +00:00
|
|
|
if not iocontrol.update_unit_statuses(packet.data) then
|
|
|
|
log.error("received invalid UNIT_STATUSES packet")
|
2022-11-13 19:13:30 +00:00
|
|
|
end
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif packet.type == SCADA_CRDN_TYPE.UNIT_CMD then
|
2022-11-13 19:13:30 +00:00
|
|
|
-- unit command acknowledgement
|
|
|
|
if packet.length == 3 then
|
|
|
|
local cmd = packet.data[1]
|
|
|
|
local unit_id = packet.data[2]
|
2023-01-23 20:10:41 +00:00
|
|
|
local ack = packet.data[3] == true
|
2022-11-13 19:13:30 +00:00
|
|
|
|
2023-01-23 20:10:41 +00:00
|
|
|
local unit = iocontrol.get_db().units[unit_id] ---@type ioctl_unit
|
2022-11-13 19:13:30 +00:00
|
|
|
|
|
|
|
if unit ~= nil then
|
2023-02-21 16:05:57 +00:00
|
|
|
if cmd == UNIT_COMMAND.SCRAM then
|
2022-11-13 19:13:30 +00:00
|
|
|
unit.scram_ack(ack)
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif cmd == UNIT_COMMAND.START then
|
2022-11-13 19:13:30 +00:00
|
|
|
unit.start_ack(ack)
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif cmd == UNIT_COMMAND.RESET_RPS then
|
2022-11-13 19:13:30 +00:00
|
|
|
unit.reset_rps_ack(ack)
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif cmd == UNIT_COMMAND.SET_BURN then
|
2022-11-13 19:13:30 +00:00
|
|
|
unit.set_burn_ack(ack)
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif cmd == UNIT_COMMAND.SET_WASTE then
|
2022-11-13 19:13:30 +00:00
|
|
|
unit.set_waste_ack(ack)
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif cmd == UNIT_COMMAND.ACK_ALL_ALARMS then
|
2022-11-26 21:18:31 +00:00
|
|
|
unit.ack_alarms_ack(ack)
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif cmd == UNIT_COMMAND.SET_GROUP then
|
2023-02-23 04:09:47 +00:00
|
|
|
-- UI will be updated to display current group if changed successfully
|
2022-11-13 19:13:30 +00:00
|
|
|
else
|
2023-01-23 20:10:41 +00:00
|
|
|
log.debug(util.c("received unit command ack with unknown command ", cmd))
|
2022-11-13 19:13:30 +00:00
|
|
|
end
|
2022-11-06 23:41:52 +00:00
|
|
|
else
|
2023-01-23 20:10:41 +00:00
|
|
|
log.debug(util.c("received unit command ack with unknown unit ", unit_id))
|
2022-11-06 23:41:52 +00:00
|
|
|
end
|
2022-10-20 16:22:03 +00:00
|
|
|
else
|
2022-11-13 19:13:30 +00:00
|
|
|
log.debug("SCADA_CRDN unit command ack packet length mismatch")
|
2022-10-20 16:22:03 +00:00
|
|
|
end
|
|
|
|
else
|
2022-11-13 19:13:30 +00:00
|
|
|
log.warning("received unknown SCADA_CRDN packet type " .. packet.type)
|
2022-10-20 16:22:03 +00:00
|
|
|
end
|
2022-06-25 17:39:47 +00:00
|
|
|
else
|
2022-11-13 19:13:30 +00:00
|
|
|
log.debug("discarding SCADA_CRDN packet before linked")
|
2022-06-25 17:39:47 +00:00
|
|
|
end
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif protocol == PROTOCOL.SCADA_MGMT then
|
2023-02-23 04:09:47 +00:00
|
|
|
---@cast packet mgmt_frame
|
2023-02-21 16:05:57 +00:00
|
|
|
if packet.type == SCADA_MGMT_TYPE.ESTABLISH then
|
2022-11-13 19:13:30 +00:00
|
|
|
-- connection with supervisor established
|
|
|
|
if packet.length == 2 then
|
|
|
|
local est_ack = packet.data[1]
|
|
|
|
local config = packet.data[2]
|
|
|
|
|
|
|
|
if est_ack == ESTABLISH_ACK.ALLOW then
|
|
|
|
if type(config) == "table" and #config > 1 then
|
|
|
|
-- get configuration
|
|
|
|
|
|
|
|
---@class facility_conf
|
|
|
|
local conf = {
|
2023-02-07 22:31:22 +00:00
|
|
|
num_units = config[1], ---@type integer
|
|
|
|
defs = {} -- boilers and turbines
|
2022-11-13 19:13:30 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
if (#config - 1) == (conf.num_units * 2) then
|
|
|
|
-- record sequence of pairs of [#boilers, #turbines] per unit
|
|
|
|
for i = 2, #config do
|
|
|
|
table.insert(conf.defs, config[i])
|
|
|
|
end
|
|
|
|
|
|
|
|
-- init io controller
|
|
|
|
iocontrol.init(conf, public)
|
|
|
|
|
|
|
|
self.sv_linked = true
|
2023-03-03 03:29:50 +00:00
|
|
|
self.sv_config_err = false
|
2022-11-13 19:13:30 +00:00
|
|
|
else
|
2023-03-03 03:29:50 +00:00
|
|
|
self.sv_config_err = true
|
|
|
|
log.warning("invalid supervisor configuration definitions received, establish failed")
|
2022-11-13 19:13:30 +00:00
|
|
|
end
|
|
|
|
else
|
2023-02-23 04:09:47 +00:00
|
|
|
log.debug("invalid supervisor configuration table received, establish failed")
|
2022-11-13 19:13:30 +00:00
|
|
|
end
|
|
|
|
else
|
2023-02-16 00:59:58 +00:00
|
|
|
log.debug("SCADA_MGMT establish packet reply (len = 2) unsupported")
|
2022-07-07 04:34:42 +00:00
|
|
|
end
|
2023-02-16 00:59:58 +00:00
|
|
|
|
|
|
|
self.last_est_ack = est_ack
|
|
|
|
elseif packet.length == 1 then
|
|
|
|
local est_ack = packet.data[1]
|
|
|
|
|
|
|
|
if est_ack == ESTABLISH_ACK.DENY then
|
|
|
|
if self.last_est_ack ~= est_ack then
|
2023-02-23 04:09:47 +00:00
|
|
|
log.info("supervisor connection denied")
|
2023-02-16 00:59:58 +00:00
|
|
|
end
|
|
|
|
elseif est_ack == ESTABLISH_ACK.COLLISION then
|
|
|
|
if self.last_est_ack ~= est_ack then
|
2023-02-23 04:09:47 +00:00
|
|
|
log.info("supervisor connection denied due to collision")
|
2023-02-16 00:59:58 +00:00
|
|
|
end
|
|
|
|
elseif est_ack == ESTABLISH_ACK.BAD_VERSION then
|
|
|
|
if self.last_est_ack ~= est_ack then
|
|
|
|
log.info("supervisor comms version mismatch")
|
|
|
|
end
|
|
|
|
else
|
|
|
|
log.debug("SCADA_MGMT establish packet reply (len = 1) unsupported")
|
|
|
|
end
|
|
|
|
|
|
|
|
self.last_est_ack = est_ack
|
2022-11-13 19:13:30 +00:00
|
|
|
else
|
|
|
|
log.debug("SCADA_MGMT establish packet length mismatch")
|
|
|
|
end
|
|
|
|
elseif self.sv_linked then
|
2023-02-21 16:05:57 +00:00
|
|
|
if packet.type == SCADA_MGMT_TYPE.KEEP_ALIVE then
|
2022-11-13 19:13:30 +00:00
|
|
|
-- keep alive request received, echo back
|
|
|
|
if packet.length == 1 then
|
|
|
|
local timestamp = packet.data[1]
|
|
|
|
local trip_time = util.time() - timestamp
|
|
|
|
|
2023-02-26 19:49:16 +00:00
|
|
|
if trip_time > 750 then
|
|
|
|
log.warning("coord KEEP_ALIVE trip time > 750ms (" .. trip_time .. "ms)")
|
2022-11-13 19:13:30 +00:00
|
|
|
end
|
2022-07-07 04:34:42 +00:00
|
|
|
|
2022-11-13 19:13:30 +00:00
|
|
|
-- log.debug("coord RTT = " .. trip_time .. "ms")
|
2022-07-07 04:34:42 +00:00
|
|
|
|
2022-12-06 16:40:13 +00:00
|
|
|
iocontrol.get_db().facility.ps.publish("sv_ping", trip_time)
|
|
|
|
|
2022-11-13 19:13:30 +00:00
|
|
|
_send_keep_alive_ack(timestamp)
|
|
|
|
else
|
|
|
|
log.debug("SCADA keep alive packet length mismatch")
|
|
|
|
end
|
2023-02-21 16:05:57 +00:00
|
|
|
elseif packet.type == SCADA_MGMT_TYPE.CLOSE then
|
2022-11-13 19:13:30 +00:00
|
|
|
-- handle session close
|
|
|
|
sv_watchdog.cancel()
|
|
|
|
self.sv_linked = false
|
|
|
|
println_ts("server connection closed by remote host")
|
2023-02-23 04:09:47 +00:00
|
|
|
log.info("server connection closed by remote host")
|
2022-07-07 04:34:42 +00:00
|
|
|
else
|
2023-02-23 04:09:47 +00:00
|
|
|
log.debug("received unknown SCADA_MGMT packet type " .. packet.type)
|
2022-07-07 04:34:42 +00:00
|
|
|
end
|
2022-06-25 17:39:47 +00:00
|
|
|
else
|
2022-11-13 19:13:30 +00:00
|
|
|
log.debug("discarding non-link SCADA_MGMT packet before linked")
|
2022-06-25 17:39:47 +00:00
|
|
|
end
|
2022-06-15 19:35:34 +00:00
|
|
|
else
|
2022-09-23 00:42:06 +00:00
|
|
|
log.debug("illegal packet type " .. protocol .. " on supervisor listening channel", true)
|
2022-06-15 19:35:34 +00:00
|
|
|
end
|
2022-09-23 00:42:06 +00:00
|
|
|
else
|
|
|
|
log.debug("received packet on unconfigured channel " .. l_port, true)
|
2022-06-15 19:35:34 +00:00
|
|
|
end
|
|
|
|
end
|
|
|
|
end
|
|
|
|
|
2022-09-03 15:51:27 +00:00
|
|
|
-- check if the coordinator is still linked to the supervisor
|
2023-02-23 04:09:47 +00:00
|
|
|
---@nodiscard
|
2022-09-03 15:51:27 +00:00
|
|
|
function public.is_linked() return self.sv_linked end
|
|
|
|
|
2022-06-15 19:35:34 +00:00
|
|
|
return public
|
2022-03-25 16:17:46 +00:00
|
|
|
end
|
2022-05-10 21:09:02 +00:00
|
|
|
|
|
|
|
return coordinator
|