cc-mek-scada/supervisor/startup.lua

244 lines
8.1 KiB
Lua
Raw Normal View History

2022-01-13 15:23:38 +00:00
--
2022-03-25 16:18:33 +00:00
-- Nuclear Generation Facility SCADA Supervisor
--
require("/initenv").init_env()
2022-11-13 20:56:27 +00:00
local crash = require("scada-common.crash")
2023-05-05 17:04:13 +00:00
local comms = require("scada-common.comms")
local log = require("scada-common.log")
local network = require("scada-common.network")
local ppm = require("scada-common.ppm")
local tcd = require("scada-common.tcd")
local util = require("scada-common.util")
2022-03-25 16:18:33 +00:00
2023-05-05 17:04:13 +00:00
local core = require("graphics.core")
2022-05-31 19:36:17 +00:00
local config = require("supervisor.config")
2023-05-05 17:04:13 +00:00
local databus = require("supervisor.databus")
local renderer = require("supervisor.renderer")
2022-05-11 15:31:02 +00:00
local supervisor = require("supervisor.supervisor")
2022-04-22 15:07:59 +00:00
2023-04-17 23:48:03 +00:00
local svsessions = require("supervisor.session.svsessions")
local SUPERVISOR_VERSION = "v1.0.0"
2022-03-25 16:18:33 +00:00
2022-04-18 15:07:16 +00:00
local println = util.println
local println_ts = util.println_ts
2022-03-25 16:18:33 +00:00
2022-06-05 19:09:02 +00:00
----------------------------------------
-- config validation
----------------------------------------
local cfv = util.new_validator()
2023-06-05 05:13:22 +00:00
cfv.assert_channel(config.SVR_CHANNEL)
cfv.assert_channel(config.PLC_CHANNEL)
cfv.assert_channel(config.RTU_CHANNEL)
cfv.assert_channel(config.CRD_CHANNEL)
cfv.assert_channel(config.PKT_CHANNEL)
cfv.assert_type_int(config.TRUSTED_RANGE)
cfv.assert_type_num(config.PLC_TIMEOUT)
2023-02-13 17:29:59 +00:00
cfv.assert_min(config.PLC_TIMEOUT, 2)
cfv.assert_type_num(config.RTU_TIMEOUT)
2023-02-13 17:29:59 +00:00
cfv.assert_min(config.RTU_TIMEOUT, 2)
cfv.assert_type_num(config.CRD_TIMEOUT)
2023-02-13 17:29:59 +00:00
cfv.assert_min(config.CRD_TIMEOUT, 2)
cfv.assert_type_num(config.PKT_TIMEOUT)
cfv.assert_min(config.PKT_TIMEOUT, 2)
2022-06-05 19:09:02 +00:00
cfv.assert_type_int(config.NUM_REACTORS)
cfv.assert_type_table(config.REACTOR_COOLING)
cfv.assert_type_int(config.FAC_TANK_MODE)
cfv.assert_type_table(config.FAC_TANK_DEFS)
2022-06-05 19:09:02 +00:00
cfv.assert_type_str(config.LOG_PATH)
cfv.assert_type_int(config.LOG_MODE)
assert(cfv.valid(), "bad config file: missing/invalid fields")
assert((config.FAC_TANK_MODE == 0) or (config.NUM_REACTORS == #config.FAC_TANK_DEFS),
"bad config file: FAC_TANK_DEFS length not equal to NUM_REACTORS")
cfv.assert_eq(#config.REACTOR_COOLING, config.NUM_REACTORS)
assert(cfv.valid(), "config: number of cooling configs different than number of units")
2022-06-05 19:09:02 +00:00
for i = 1, config.NUM_REACTORS do
cfv.assert_type_table(config.REACTOR_COOLING[i])
assert(cfv.valid(), "config: missing cooling entry for reactor " .. i)
2022-06-05 19:09:02 +00:00
cfv.assert_type_int(config.REACTOR_COOLING[i].BOILERS)
cfv.assert_type_int(config.REACTOR_COOLING[i].TURBINES)
cfv.assert_type_bool(config.REACTOR_COOLING[i].TANK)
assert(cfv.valid(), "config: missing boilers/turbines for reactor " .. i)
2022-06-05 19:09:02 +00:00
cfv.assert_min(config.REACTOR_COOLING[i].BOILERS, 0)
cfv.assert_min(config.REACTOR_COOLING[i].TURBINES, 1)
assert(cfv.valid(), "config: bad number of boilers/turbines for reactor " .. i)
2022-06-05 19:09:02 +00:00
end
----------------------------------------
-- log init
----------------------------------------
log.init(config.LOG_PATH, config.LOG_MODE, config.LOG_DEBUG == true)
log.info("========================================")
log.info("BOOTING supervisor.startup " .. SUPERVISOR_VERSION)
log.info("========================================")
2022-04-18 15:07:16 +00:00
println(">> SCADA Supervisor " .. SUPERVISOR_VERSION .. " <<")
2022-03-25 16:18:33 +00:00
2022-11-13 20:56:27 +00:00
crash.set_env("supervisor", SUPERVISOR_VERSION)
2022-06-05 19:09:02 +00:00
----------------------------------------
2022-11-13 20:56:27 +00:00
-- main application
2022-06-05 19:09:02 +00:00
----------------------------------------
2022-11-13 20:56:27 +00:00
local function main()
----------------------------------------
-- startup
----------------------------------------
2022-03-25 16:18:33 +00:00
2023-05-05 17:04:13 +00:00
-- record firmware versions and ID
databus.tx_versions(SUPERVISOR_VERSION, comms.version)
2022-11-13 20:56:27 +00:00
-- mount connected devices
ppm.mount_all()
2023-06-25 18:00:18 +00:00
-- message authentication init
if type(config.AUTH_KEY) == "string" then
network.init_mac(config.AUTH_KEY)
end
-- get modem
2022-11-13 20:56:27 +00:00
local modem = ppm.get_wireless_modem()
if modem == nil then
2023-02-25 04:36:16 +00:00
println("startup> wireless modem not found")
2022-11-13 20:56:27 +00:00
log.fatal("no wireless modem on startup")
return
end
2022-03-25 16:18:33 +00:00
2023-05-05 17:04:13 +00:00
databus.tx_hw_modem(true)
-- start UI
local fp_ok, message = pcall(renderer.start_ui)
if not fp_ok then
renderer.close_ui()
println_ts(util.c("UI error: ", message))
2023-07-11 19:15:44 +00:00
log.error(util.c("front panel GUI render failed with error ", message))
2023-05-05 17:04:13 +00:00
else
-- redefine println_ts local to not print as we have the front panel running
println_ts = function (_) end
end
-- create network interface then setup comms
local nic = network.nic(modem)
local superv_comms = supervisor.comms(SUPERVISOR_VERSION, nic, fp_ok)
2022-11-13 20:56:27 +00:00
-- base loop clock (6.67Hz, 3 ticks)
local MAIN_CLOCK = 0.15
local loop_clock = util.new_clock(MAIN_CLOCK)
-- start clock
loop_clock.start()
-- halve the rate heartbeat LED flash
local heartbeat_toggle = true
2022-11-13 20:56:27 +00:00
-- event loop
while true do
local event, param1, param2, param3, param4, param5 = util.pull_event()
-- handle event
if event == "peripheral_detach" then
local type, device = ppm.handle_unmount(param1)
if type ~= nil and device ~= nil then
if type == "modem" then
-- we only care if this is our wireless modem
if nic.is_modem(device) then
nic.disconnect()
2022-11-13 20:56:27 +00:00
println_ts("wireless modem disconnected!")
2023-02-25 04:36:16 +00:00
log.warning("comms modem disconnected")
local other_modem = ppm.get_wireless_modem()
if other_modem then
log.info("found another wireless modem, using it for comms")
nic.connect(other_modem)
else
databus.tx_hw_modem(false)
end
2022-11-13 20:56:27 +00:00
else
log.warning("non-comms modem disconnected")
end
end
2022-04-18 15:07:16 +00:00
end
2022-11-13 20:56:27 +00:00
elseif event == "peripheral" then
local type, device = ppm.mount(param1)
if type ~= nil and device ~= nil then
if type == "modem" then
if device.isWireless() and not nic.is_connected() then
2022-11-13 20:56:27 +00:00
-- reconnected modem
nic.connect(device)
2022-11-13 20:56:27 +00:00
println_ts("wireless modem reconnected.")
2023-02-25 04:36:16 +00:00
log.info("comms modem reconnected")
databus.tx_hw_modem(true)
elseif device.isWireless() then
log.info("unused wireless modem reconnected")
2022-11-13 20:56:27 +00:00
else
2023-02-25 04:36:16 +00:00
log.info("wired modem reconnected")
2022-11-13 20:56:27 +00:00
end
end
2022-04-18 15:07:16 +00:00
end
2022-11-13 20:56:27 +00:00
elseif event == "timer" and loop_clock.is_clock(param1) then
-- main loop tick
if heartbeat_toggle then databus.heartbeat() end
heartbeat_toggle = not heartbeat_toggle
2022-11-13 20:56:27 +00:00
-- iterate sessions
svsessions.iterate_all()
-- free any closed sessions
svsessions.free_all_closed()
loop_clock.start()
elseif event == "timer" then
-- a non-clock timer event, check watchdogs
svsessions.check_all_watchdogs(param1)
-- notify timer callback dispatcher
tcd.handle(param1)
2022-11-13 20:56:27 +00:00
elseif event == "modem_message" then
-- got a packet
local packet = superv_comms.parse_packet(param1, param2, param3, param4, param5)
superv_comms.handle_packet(packet)
elseif event == "mouse_click" or event == "mouse_up" or event == "mouse_drag" or event == "mouse_scroll" then
-- handle a mouse event
renderer.handle_mouse(core.events.new_mouse_event(event, param1, param2, param3))
2022-04-18 15:07:16 +00:00
end
2022-11-13 20:56:27 +00:00
-- check for termination request
if event == "terminate" or ppm.should_terminate() then
println_ts("closing sessions...")
log.info("terminate requested, closing sessions...")
svsessions.close_all()
log.info("sessions closed")
break
end
2022-03-25 16:18:33 +00:00
end
2022-11-13 20:56:27 +00:00
renderer.close_ui()
util.println_ts("exited")
2022-11-13 20:56:27 +00:00
log.info("exited")
2022-03-25 16:18:33 +00:00
end
2022-04-18 15:07:16 +00:00
2023-05-05 17:04:13 +00:00
if not xpcall(main, crash.handler) then
pcall(renderer.close_ui)
crash.exit()
else
log.close()
end